Table of Contents
Toggle1. System Overview
The KITOZER 4G/5G base station rectifier module system is a high-frequency switching AC/DC power conversion device specially designed for communication base stations. Its core function is to efficiently convert 220V/380V alternating current into -48V direct current, delivering stable, clean and uninterrupted power supply for base station BBU, RRU, transmission equipment and monitoring systems.

4G/5G Base Station Rectifier Module
2. System Composition
The KITOZER base station rectifier module system consists of five major parts: core functional unit, auxiliary unit, monitoring unit, power distribution unit and protection unit. All units work collaboratively to form a complete power supply solution for base stations:
- Rectifier Module (Core Unit): The heart of the system, realizing AC/DC conversion via high-frequency switching technology with efficiency ≥96%. It supports hot swapping and parallel redundancy.
- Monitoring Module (Control Unit): The “brain” of the system, responsible for parameter collection, current sharing control, battery management, alarm handling and remote communication. It supports RS485/Ethernet/SNMP protocols.
- AC Power Distribution Unit: Equipped with input circuit breakers, lightning arresters and filters, it implements mains power access, surge protection and EMI suppression, and supports automatic switching between dual mains power sources.
- DC Power Distribution Unit: Built with output circuit breakers, fuses and lightning arresters, it distributes -48V DC output, connects batteries and controls secondary power disconnection.
- Storage Battery Pack (Backup Unit): Valve-regulated lead-acid batteries or lithium batteries that seamlessly switch to power loads once mains power fails to ensure uninterrupted communication.
- Cabinet & Heat Dissipation Unit: Standard 19-inch cabinets with front air intake and rear air outlet heat dissipation design. Redundant fans run at intelligent variable speeds, adapting to a wide temperature range of -40℃ ~ +65℃.

Internal Circuit Board of Rectifier Module
3. System Classification
KITOZER base station rectifier module systems are categorized by four dimensions: power rating, technical route, application scenario and heat dissipation mode, covering full series of low, medium and high-power products.
3.1 Classification by Power Rating
- Low-power Type (≤1.5kW): Output current 10A~30A, suitable for 5G micro base stations, indoor distribution, small base stations and edge computing nodes.
- Medium-power Type (1.5kW/3kW): Output current 50A/75A, applicable to 4G/5G macro base stations, suburban base stations and transmission aggregation nodes.
- High-power Type (≥3kW): Output current 100A~200A, designed for dense 5G networking, core equipment rooms and base station PV-storage hybrid systems.
3.2 Classification by Technical Route
- Basic Type (Hard Switching): Traditional PWM control with high cost performance and efficiency of 92%~94%, ideal for low-cost scenarios.
- High-efficiency Type (LLC Resonance): Soft-switching technology with efficiency of 96%~98%, low ripple and low noise, matching high-density base stations.
- Ultra-high-efficiency Type (GaN Gallium Nitride): Third-generation semiconductor technology with peak efficiency ≥98% and 50% higher power density, optimized for eco-friendly low-carbon base stations.
3.3 Classification by Application Scenario
- Indoor Type: Standard 19-inch cabinets for constant-temperature environments, prioritizing high efficiency and intelligent management.
- Outdoor Type: IP55 protection grade, wide temperature resistance (-40℃~+65℃), lightning and corrosion resistance, deployed on mountain tops, coastal areas and other outdoor base stations.
- Embedded Type: 1U/3U plug-in frame design with compact size, integrated inside base station equipment for space-limited deployment.
3.4 Classification by Heat Dissipation Mode
- Natural Heat Dissipation Type: Heat dissipated through metal housing without fans, zero noise for low-power and noise-sensitive scenarios.
- Forced Air Cooling Type: Redundant fans with intelligent temperature control for strong heat dissipation and full-load operation, used for medium and high-power applications.

Automatic Production Workshop
4. System Schematic Diagram
5. Full System Configuration List (Low / Medium / High Tiers)
5.1 Low-tier Configuration List (Micro Base Station / Indoor Distribution, ≤1.5kW)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | High-frequency Rectifier Module | KITOZER-R4830-L | Input: 220VAC±20%, 45~65Hz; Output: -48V/30A; Efficiency ≥94%; Ripple ≤50mV; Cooling: natural cooling; Protection: IP20 | 2 | Pcs | KITOZER | 1+1 redundancy, hot-swappable |
| 2 | Monitoring Module | KITOZER-MON-L | Digital control; Communication: RS485; Functions: current sharing, battery management, alarm; Display: LED digital tube | 1 | Pcs | KITOZER | Matches low-tier rectifier modules |
| 3 | AC Power Distribution Unit | KITOZER-AC-100-L | Input: 220VAC/100A; Circuit breaker: 1P/63A; Lightning protection: differential mode 6kV / common mode 10kV; EMI filter | 1 | Set | KITOZER | Includes input cables and terminals |
| 4 | DC Power Distribution Unit | KITOZER-DC-100-L | Output: -48V/100A; Circuit breaker: 2P/63A; Fuse: 50A; Lightning protection: differential mode 5kV; Supports secondary power disconnection | 1 | Set | KITOZER | Equipped with battery terminals |
| 5 | VRLA Battery | KITOZER-BAT-12V-50AH | Voltage: 12V; Capacity: 50AH; Float charge voltage: 13.5V; Cycle life ≥500 times; Operating temp: -10℃~+40℃ | 4 | Pcs | KITOZER | Series connected to form -48V, 1-hour backup power |
| 6 | 19-inch Standard Cabinet | KITOZER-CAB-12U-L | Size: 600×600×600mm; Material: cold-rolled steel; Protection: IP20; Natural ventilation; Color: grey | 1 | Pcs | KITOZER | Wall-mounted, complete with mounting accessories |
5.2 Medium-tier Configuration List (4G/5G Macro Base Station, 1.5kW~3kW)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | High-frequency Rectifier Module | KITOZER-R4875-M | Input: 220VAC±30%, 45~65Hz; Output: -48V/75A; Efficiency ≥96%; Ripple ≤30mV; Cooling: forced air cooling; Protection: IP30 | 2 | Pcs | KITOZER | 1+1 redundancy, hot-swappable, LLC resonance |
| 2 | Monitoring Module | KITOZER-MON-M | Digital control; Communication: RS485/Ethernet; Functions: current sharing, refined battery management, remote monitoring; Display: LCD touch screen | 1 | Pcs | KITOZER | Supports SNMP protocol, connects to environment monitoring system |
| 3 | AC Power Distribution Unit | KITOZER-AC-200-M | Input: 220VAC/200A; Circuit breaker: 2P/100A; Lightning protection: differential mode 10kV / common mode 15kV; EMI+EMC filter; Dual power automatic switching | 1 | Set | KITOZER | Includes lightning arrester, filter and terminals |
| 4 | DC Power Distribution Unit | KITOZER-DC-200-M | Output: -48V/200A; Circuit breaker: 2P/125A; Fuse: 80A; Lightning protection: differential mode 8kV; Programmable secondary power disconnection; Insulation monitoring supported | 1 | Set | KITOZER | Equipped with battery fuse and alarm output |
| 5 | VRLA Battery | KITOZER-BAT-12V-100AH | Voltage: 12V; Capacity: 100AH; Float charge voltage:13.5V; Equalization charge voltage:14.4V; Cycle life ≥800 times; Operating temp: -20℃~+45℃ | 4 | Pcs | KITOZER | Series connected to form -48V, 2-hour backup power |
| 6 | 19-inch Standard Cabinet | KITOZER-CAB-21U-M | Size:600×600×1000mm; Material: cold-rolled steel with electrostatic coating; Protection: IP30; Front-in rear-out air cooling; 2 intelligent variable-speed fans | 1 | Pcs | KITOZER | Floor-standing, with cabinet lock and cable manager |
5.3 High-tier Configuration List (Dense 5G Network / Core Equipment Room, ≥3kW)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Ultra-high-efficiency GaN Rectifier Module | KITOZER-R48150-H | Input:380VAC±30%,45~65Hz; Output:-48V/150A; Efficiency≥98%; Ripple≤20mV; Cooling: forced air cooling; Protection:IP40; GaN gallium nitride technology | 3 | Pcs | KITOZER | 2+1 redundancy, hot-swappable, peak efficiency 98.5% |
| 2 | Intelligent Monitoring Module | KITOZER-MON-H | Digital control + AI edge computing; Communication:Ethernet/4G/5G, Modbus TCP/SNMP/IEC 61850 compatible; Functions: power health analysis, fault early warning, battery temperature compensation, remote O&M; Display:7-inch LCD touch screen | 1 | Pcs | KITOZER | Seamlessly connects to base station FSU, supports cloud management |
| 3 | AC Power Distribution Unit | KITOZER-AC-400-H | Input:380VAC/400A; Circuit breaker:3P/250A; Lightning protection: differential mode15kV/common mode20kV; EMI+EMC filter; Dual power auto-switch; 0.5S high-precision smart electricity meter | 1 | Set | KITOZER | Equipped with lightning arrester, filter and auto-switch |
| 4 | DC Power Distribution Unit | KITOZER-DC-400-H | Output:-48V/400A; Circuit breaker:2P/250A; Fuse:150A; Lightning protection: differential mode10kV; Programmable secondary power disconnection; High-precision insulation monitoring; Dual battery group access | 1 | Set | KITOZER | Includes battery fuse, insulation monitor and alarm output |
| 5 | Lithium Iron Phosphate Battery Pack | KITOZER-BAT-48V-200AH | Voltage:48V; Capacity:200AH; Charge-discharge efficiency≥95%; Cycle life≥2000 times; Operating temp:-30℃~+55℃; Built-in BMS for overvoltage/undervoltage/overcurrent/overheat protection | 1 | Set | KITOZER | 3-hour backup power, supports fast charging |
| 6 | 19-inch Standard Cabinet | KITOZER-CAB-42U-H | Size:600×800×2000mm; Material: anti-corrosion coated cold-rolled steel; Protection:IP55; Front-in rear-out cooling; 4 redundant intelligent fans; Built-in cabinet temperature/humidity, door contact and smoke alarms | 1 | Pcs | KITOZER | Floor-standing, with cabinet air conditioner, cable manager and ground bar |
6. Full Product Technical Specifications
6.1 Rectifier Module Technical Specifications
è¡¨æ ¼
| Parameter | Low-tier (R4830-L) | Medium-tier (R4875-M) | High-tier (R48150-H) |
|---|---|---|---|
| Input Voltage | 220VAC±20% | 220VAC±30% | 380VAC±30% |
| Input Frequency | 45~65Hz | 45~65Hz | 45~65Hz |
| Power Factor | ≥0.95 | ≥0.97 | ≥0.99 |
| Output Voltage | -48V (adjustable 42~58V) | -48V (adjustable 42~58V) | -48V (adjustable 42~58V) |
| Output Current | 30A | 75A | 150A |
| Conversion Efficiency | ≥94% | ≥96% | ≥98% |
| Ripple Noise | ≤50mV | ≤30mV | ≤20mV |
| Heat Dissipation | Natural cooling | Forced air cooling | Forced air cooling |
| Operating Temp | -10℃~+45℃ | -20℃~+55℃ | -30℃~+65℃ |
| Protection Grade | IP20 | IP30 | IP40 |
| Parallel Redundancy | 1+1 supported | 1+1/N+X supported | 2+1/N+X supported |
| Hot Swapping | Supported | Supported | Supported |
6.2 Monitoring Module Technical Specifications
è¡¨æ ¼
| Parameter | Low-tier (MON-L) | Medium-tier (MON-M) | High-tier (MON-H) |
|---|---|---|---|
| Control Mode | Digital PWM | Digital LLC | Digital + AI Edge Computing |
| Communication Interface | RS485 | RS485/Ethernet | Ethernet/4G/5G |
| Communication Protocol | Modbus RTU | Modbus RTU/TCP, SNMP | Modbus TCP, SNMP, IEC 61850, MQTT |
| Display | LED Digital Tube | LCD Touch Screen | 7-inch LCD Touch Screen |
| Current Sharing Accuracy | ≤±1% | ≤±0.5% | ≤±0.3% |
| Battery Management | Basic charge & discharge | 4-stage charging (constant current-constant voltage-float-equalization) | 4-stage charging + temperature compensation (-5mV/℃ per cell) |
| Alarm Functions | Overvoltage, undervoltage, overcurrent, overheat | Overvoltage, undervoltage, overcurrent, overheat, lightning protection failure, fan fault | Overvoltage, undervoltage, overcurrent, overheat, lightning protection failure, fan fault, insulation fault, battery failure early warning |
| Remote Functions | None | Remote voltage regulation, current limiting, power on/off, fault query | Remote voltage regulation, current limiting, power on/off, fault diagnosis, health analysis, OTA upgrade |
6.3 Storage Battery Technical Specifications
è¡¨æ ¼
| Parameter | Low-tier (12V-50AH) | Medium-tier (12V-100AH) | High-tier (48V-200AH) |
|---|---|---|---|
| Battery Type | VRLA Lead-acid Battery | VRLA Lead-acid Battery | Lithium Iron Phosphate Battery |
| Rated Voltage | 12V | 12V | 48V |
| Rated Capacity | 50AH | 100AH | 200AH |
| Float Charge Voltage | 13.5V | 13.5V | 53.5V |
| Equalization Charge Voltage | 14.4V | 14.4V | 56.4V |
| Charge-discharge Efficiency | ≥85% | ≥90% | ≥95% |
| Cycle Life | ≥500 times | ≥800 times | ≥2000 times |
| Operating Temperature | -10℃~+40℃ | -20℃~+45℃ | -30℃~+55℃ |
| Protection Functions | Overvoltage, undervoltage, overcurrent | Overvoltage, undervoltage, overcurrent, overheat | Overvoltage, undervoltage, overcurrent, overheat, short circuit, full BMS protection |
7. Full Product Application Scope

On-site Installation & Commissioning
7.1 Rectifier Module Application Scope
- Low-tier R4830-L: 5G micro base stations, indoor distribution systems, small base stations, edge computing nodes, optical nodes, monitoring base stations.
- Medium-tier R4875-M: 4G/5G macro base stations, suburban base stations, transmission aggregation nodes, subway tunnel base stations, indoor coverage systems.
- High-tier R48150-H: Dense 5G networking base stations, core equipment rooms, base station PV-storage hybrid systems, data centers, high-speed rail/highway roadside base stations.
7.2 Monitoring Module Application Scope
- Low-tier MON-L: Low-cost small base stations, micro base stations, scenarios without remote monitoring demands.
- Medium-tier MON-M: Standard 4G/5G macro base stations, scenarios requiring connection to environment monitoring systems, medium-scale base station clusters.
- High-tier MON-H: Large base stations, core equipment rooms, smart grid, scenarios requiring cloud management and fault early warning, PV-storage hybrid systems.
7.3 Storage Battery Application Scope

Exploded Drawing of Rectifier Module
- Low-tier 12V-50AH: Micro base stations, small base stations, scenarios with short backup time (≤1 hour).
- Medium-tier 12V-100AH: Macro base stations, scenarios with medium backup time (1~2 hours), suburban base stations.
- High-tier 48V-200AH: Core equipment rooms, dense base stations, scenarios with long backup time (≥3 hours), PV-storage hybrid systems.
8. Core Advantages of All Products
8.1 Advantages of Rectifier Modules
- High Reliability: N+X redundant architecture; faulty modules automatically disconnect without disrupting system operation; MTBF ≥200,000 hours, supporting 24/7 full-load operation.
- Energy-saving & High Efficiency: LLC resonance/GaN technology delivers maximum 98% efficiency, cutting annual electricity costs by over ten thousand RMB compared with traditional modules; ultra-low ripple (≤20mV) protects precision communication equipment.
- Wide Environmental Adaptability: Ultra-wide input voltage tolerance (220VAC±30%/380VAC±30%) withstands severe grid fluctuations; wide temperature range (-30℃~+65℃) adapts to harsh field environments.
- Intelligent & Easy O&M: Hot-swappable design allows module replacement without power cut; full remote monitoring and operation reduce on-site maintenance costs.
- Customization Support: Customizable output voltage, current and communication protocols; OEM/ODM service available with strict confidential protection for client technical data.
- Spot Inventory: Full product series in stock for fast delivery and rapid response to client orders.
8.2 Advantages of Monitoring Modules

Rectifier Modules Installed in Cabinet
- Intelligent Management: AI edge computing locally analyzes power system health and sends fault early warnings to avoid sudden outages; 4-stage battery charging plus temperature compensation extends battery service life by over 50%.
- Multi-protocol Compatibility: Supports mainstream protocols including Modbus, SNMP and IEC 61850 for seamless interconnection with base station environment monitoring systems and cloud platforms.
- High-precision Control: Current sharing accuracy ≤±0.3% and voltage regulation accuracy ≤0.5% guarantee stable power output; load step response recovery time ≤200μS.
- Comprehensive Alarm Mechanism: Multi-layer real-time status monitoring with instant abnormal reporting to speed up fault troubleshooting.
8.3 Advantages of Storage Batteries
- Long Service Life: Lithium iron phosphate batteries with ≥2000 charge-discharge cycles; VRLA lead-acid batteries with ≥800 cycles to lower replacement frequency and lifecycle cost.
- High Safety: Full BMS protection against overvoltage, undervoltage, overcurrent, overheat and short circuit; lithium iron phosphate chemistry eliminates explosion risks for enhanced operational safety.
- Wide Temperature Performance: Stable operation from -30℃ to +55℃ with excellent low-temperature discharge performance even under extreme cold.
9. Tender Control Parameters of All Products (*Marked Items)
9.1 Rectifier Module Tender Control Parameters

4G/5G Base Station Central Monitoring Platform
-
- Input voltage range: 220VAC±30% (medium-tier) / 380VAC±30% (high-tier), 45~65Hz
-
- Output voltage: -48V, adjustable range 42~58V
-
- Conversion efficiency: ≥96% for medium-tier, ≥98% for high-tier
-
- Ripple noise: ≤30mV (medium-tier) / ≤20mV (high-tier)
-
- Heat dissipation: forced air cooling with redundant intelligent variable-speed fans
-
- Operating temperature: -20℃~+55℃ (medium-tier) / -30℃~+65℃ (high-tier)
-
- Parallel redundancy: N+X redundancy supported, hot-swappable design
-
- MTBF: ≥200,000 hours
9.2 Monitoring Module Tender Control Parameters
-
- Communication interfaces: RS485/Ethernet (medium-tier) / Ethernet/4G/5G (high-tier)
-
- Communication protocols: Modbus RTU/TCP, SNMP (medium-tier) / IEC 61850, MQTT (high-tier)
-
- Current sharing accuracy: ≤±0.5% (medium-tier) / ≤±0.3% (high-tier)
-
- Battery management: 4-stage charging + temperature compensation (high-tier)
-
- Remote functions: Remote voltage regulation, current limiting, power on/off, fault diagnosis (high-tier)
9.3 Storage Battery Tender Control Parameters
-
- Battery type: Lithium iron phosphate battery (high-tier)
-
- Rated voltage: 48V (high-tier)
-
- Cycle life: ≥2000 times (high-tier)
-
- Operating temperature: -30℃~+55℃ (high-tier)
-
- Protection functions: BMS full protection for overvoltage, undervoltage, overcurrent, overheat and short circuit
10. Full Product Solutions

Outdoor Tower-mounted Base Station Power Equipment
10.1 Micro Base Station / Indoor Distribution Solution (Low-tier)
Designed for low-power scenarios such as 5G micro base stations and indoor distribution systems. The solution combines KITOZER-R4830-L rectifier module, MON-L monitoring module and 12V-50AH storage battery, adopting 1+1 redundant design and natural heat dissipation. It features compact size, low cost and easy wall-mounted cabinet installation, meeting 24/7 power supply demands with basic monitoring and alarm functions.
10.2 4G/5G Macro Base Station Solution (Medium-tier)
Tailored for medium-power 4G/5G macro base stations and suburban sites. The package includes KITOZER-R4875-M LLC resonant rectifier module, MON-M monitoring module and 12V-100AH lead-acid batteries with 1+1 redundancy, forced air cooling and ≥96% conversion efficiency. It supports RS485/Ethernet communication and SNMP protocol for seamless connection to environment monitoring systems, realizing remote monitoring and refined battery management with 2-hour backup power for stable macro station operation.
10.3 Dense 5G Network / Core Equipment Room Solution (High-tier)
Built for high-power dense 5G networking and core equipment rooms. The system integrates GaN-based KITOZER-R48150-H ultra-high-efficiency rectifier module, AI-enabled MON-H monitoring module and 48V-200AH lithium iron phosphate battery pack with 2+1 redundancy. Achieving ≥98% efficiency via gallium nitride technology, it supports multi-protocol communication, AI-driven power health analysis and fault early warning, delivers 3-hour backup power and connects seamlessly to PV-storage hybrid systems to meet low-carbon and intelligent O&M targets.
11. Product Application Cases
11.1 China Mobile Guangdong 5G Micro Base Station Project

Internal Wiring of Outdoor Power Cabinet
- Location: Guangzhou, Shenzhen, Dongguan, Guangdong Province
- Scale: 1,000 sets of 5G micro base stations
- Configuration: 2×KITOZER-R4830-L + 1×MON-L + 4×12V-50AH + 12U wall-mounted cabinet
- Project Outcomes: Zero unplanned downtime during stable long-term operation; silent natural cooling fits residential and indoor environments; low overall cost and short installation cycle, full deployment completed within 30 days.
11.2 China Unicom 4G/5G Macro Base Station Capacity Expansion Project
- Location: Nanjing, Suzhou, Wuxi, Jiangsu Province
- Scale: 500 sets of 4G/5G macro base stations
- Configuration: 2×KITOZER-R4875-M + 1×MON-M + 4×12V-100AH + 21U floor-standing cabinet
- Project Outcomes: System efficiency raised to 96.5% with annual electricity savings of around 800,000 RMB; remote O&M boosts maintenance efficiency by 60%; battery service life extended by 50% to cut replacement costs.
11.3 China Telecom Dense 5G Networking Project
- Location: Hangzhou, Ningbo, Zhejiang Province
- Scale: 200 sets of dense 5G base stations
- Configuration: 3×KITOZER-R48150-H + 1×MON-H + 1×48V-200AH lithium iron phosphate pack + 42U floor-standing cabinet
- Project Outcomes: Peak system efficiency hits 98.2%, saving roughly 2 million RMB on annual electricity bills; AI early warning prevented 15 potential critical faults; compatible with PV-storage hybrid systems to lift new energy utilization rate by 30% and satisfy green low-carbon standards.
12. Common Product Faults & Maintenance Specifications
12.1 Common Faults & Troubleshooting
è¡¨æ ¼
| Fault Phenomenon | Possible Causes | Solutions |
|---|---|---|
| No output from rectifier module | Abnormal mains input; defective module; tripped circuit breaker | Inspect mains power supply; replace faulty module; reset circuit breaker |
| Unstable output voltage | Severe grid fluctuation; abnormal module current sharing; faulty monitoring module | Verify input voltage range; recalibrate current sharing; replace monitoring module |
| Excessive output ripple | Aging module; failed filter capacitor; poor grounding | Replace rectifier module; replace filter capacitor; rework grounding connection |
| No communication from monitoring module | Loose communication cable; mismatched protocol; defective module | Reconnect communication wiring; confirm communication protocol matching; replace monitoring module |
| Storage battery fails to charge | Abnormal charging voltage; aged battery; BMS protection triggered | Adjust rectifier module output voltage; replace defective battery; troubleshoot BMS faults |
12.2 Maintenance Specifications
- Daily Maintenance: Check cabinet indicator lights for normal module operation; review monitoring module alarm logs and resolve abnormalities promptly; monitor cabinet temperature and humidity to keep within rated range.
- Monthly Maintenance: Clean cooling fans and filter screens to avoid dust accumulation blocking heat dissipation; tighten loose wiring terminals; test battery voltage and internal resistance to evaluate battery health status.
- Annual Maintenance: Calibrate monitoring module parameters to guarantee control precision; test lightning arrester performance and replace failed units; conduct full charge-discharge cycle testing on storage batteries and replace under-capacity batteries; measure cabinet grounding resistance to ensure reliable grounding.
- Maintenance Precautions: Hot-swap rectifier modules without power cut; wear anti-static wristbands during maintenance to prevent electrostatic damage to circuit boards; strictly avoid disassembling live wiring terminals to eliminate electric shock hazards.
13. Factory Strength & After-sales Service
13.1 Factory Strength
KITOZER is a high-tech enterprise integrating R&D, production, sales and service of communication power supply and base station power equipment, with manufacturing base located in Guangzhou, Guangdong Province. The factory covers 10,000 square meters with 5 automated production lines and 2 dedicated R&D laboratories, with an annual output of 100,000 rectifier modules and 50,000 complete power supply systems.
The company’s R&D team consists of 50 specialists, all with over 10 years of experience in communication power supply industry, holding a total of 30 patents including 8 invention patents, maintaining leading technical competitiveness across the sector. It has obtained ISO9001 quality management certification, ISO14001 environmental management certification, CE certification and CTTL certification. Products fully comply with domestic and international industry standards and are exported to over 50 countries worldwide.
13.2 After-sales Service
- Warranty Commitment: 3-year free warranty for all product lines, lifetime maintenance service; free spare parts or full unit replacement for non-human-induced damage within warranty period.
- Technical Support: 7×24-hour technical hotline with response within 1 hour and complete solution delivered within 4 hours; remote online troubleshooting available to eliminate unnecessary site visits.
- On-site Service: 30 service outlets nationwide; engineers arrive on-site within 24 hours and resolve faults within 48 hours; dedicated on-site technicians assigned for large-scale projects to track full project progress.
- Training Service: Free product operation, maintenance and fault diagnosis training via online and offline sessions to ensure customer staff full operational proficiency.
- Spare Parts Support: 5 national spare parts warehouses stocked with full-series components for fast replacement and minimized base station downtime.
14. Conclusion
Featuring outstanding reliability, ultra-high energy efficiency, wide environmental adaptability and intelligent operation, the KITOZER 4G/5G base station rectifier module system covers all low, medium and high power tiers, delivering integrated power supply solutions for 4G/5G macro base stations, micro base stations, indoor distribution and edge computing scenarios.
Built with modular, redundant and intelligent design, the system supports hot swapping and full remote monitoring & maintenance, significantly cutting base station construction and lifecycle operation costs, and assisting telecom operators in achieving low-carbon green development and intelligent network management goals.
Moving forward, KITOZER will continuously increase R&D investment to innovate products and technologies, providing more efficient, reliable and intelligent power supply solutions for global 4G/5G communication network construction and supporting high-quality development of the communication industry.
15. Search Keywords & SEO Tags
15.1 Search Keywords
4G base station rectifier module, 5G base station rectifier module, base station power rectifier module, communication base station rectifier module, -48V rectifier module, high-frequency rectifier module, intelligent rectifier module, KITOZER rectifier module, base station power supply solution, 5G macro base station power supply, 5G micro base station power supply, PV-storage hybrid base station power supply
15.2 Tags
#4GBaseStationRectifierModule #5GBaseStationRectifierModule #BaseStationPowerSupply #CommunicationPowerSupply #KITOZER #RectifierModule #HighFrequencyRectifier #IntelligentRectifier #BaseStationPowerSolution #5GMacroStationPower #5GMicroStationPower