Table of Contents
Toggle1. System Overview
The KITOZER base station pole system is a dedicated antenna feed support system for the construction of 4G/5G mobile communication networks. Primarily deployed on rooftops, walls, and ground sites, it delivers stable load-bearing, precise positioning and safety protection for base station antennas, RRUs, feeders and auxiliary equipment. It serves as core infrastructure for space-constrained scenarios in large-scale 5G deployment.
Compliant with standards including GB 50009-2012 Load Code for the Design of Building Structures, YD/T 5160-2021 Classification Standard for Seismic Fortification of Communication Building Engineering, and YD/T 2187-2010 Code for Design of Lightning Protection and Earthing Engineering of Communication Stations, the system adopts high-strength steel and multi-layer anti-corrosion treatments. It withstands up to Level 12 winds and Magnitude 8 earthquakes, meeting the lightweight and highly integrated installation requirements of 5G Massive MIMO antennas while remaining compatible with traditional 4G equipment. Featuring non-penetrating installation, rapid deployment, landscape compatibility and an extended maintenance-free service life, it is widely applied in urban signal gap filling, township coverage, scenic area beautification, industrial private networks and other scenarios.

Base Station Pole
2. System Composition
Adopting a modular design, the KITOZER base station pole system consists of six core units: main load-bearing unit, support & fixing unit, equipment mounting unit, lightning protection & earthing unit, protective accessory unit, and intelligent monitoring unit (optional for high-end configurations). All units work in synergy to guarantee structural stability and operational safety.
- Main Load-bearing Unit: Core load-bearing components including pole body (Q235B/Q355B hot-dip galvanized steel pipe), connecting flanges and reinforcing ribs. It bears vertical equipment loads and horizontal wind loads, with pipe diameters ranging Φ76–Φ159mm and wall thicknesses 4–6mm.
- Support & Fixing Unit: Comprises diagonal braces, cross arms, counterweight bases/concrete foundations, wall-mounted hoops and high-strength bolts. It reliably secures the pole to buildings or ground, disperses horizontal forces and prevents overturning or sliding. Counterweight bases use high-density concrete for non-penetrating installation to protect waterproof layers.
- Equipment Mounting Unit: Includes adjustable antenna brackets, RRU hangers, feeder clamps and adjusting bolts. It supports antenna pitch angle adjustment from 0° to 90° and full 360° azimuth rotation, fitting 4G/5G antennas and RRUs of varying sizes and weights.
- Lightning Protection & Earthing Unit: Consists of stainless steel lightning rods, galvanized flat steel/down conductors, earthing terminals and ground electrodes. The lightning rod is mounted at the pole top and connects the pole to the building earthing system, achieving an earthing resistance ≤4Ω (high-end configuration) for effective lightning strike protection.
- Protective Accessory Unit: Features hot-dip galvanizing plus anti-corrosion paint coating, waterproof sealing rings, anti-theft bolts and fiberglass camouflage covers. These components deliver long-term corrosion resistance and can disguise the pole as air conditioning units or square columns to harmonize with urban landscapes.
- Intelligent Monitoring Unit (Optional for High-end Configurations): Equipped with tilt sensors, stress sensors and wireless transmission modules to real-time monitor pole inclination and stress conditions, triggering automatic alerts for abnormal statuses to ensure operational safety.
3. System Classification

CAD Drawing of Base Station Pole
The KITOZER base station pole system is categorized across five dimensions: installation scenario, fixing method, structural form, height specification and load capacity, fully covering all base station construction scenarios.
3.1 Classification by Installation Scenario
- Rooftop Pole: Installed on parapets or roof slabs with heights 1–6m. Simple in shape and easy to relocate, suitable for signal coverage in dense urban buildings.
- Wall-mounted Pole: Fixed to building walls via hoops with heights 1–4m. Saves rooftop space for sites with limited roof area.
- Ground Pole: Deployed on suburban/mountain ground with heights 6–12m, paired with independent concrete foundations for remote area signal filling and factory coverage.
- Bionic Pole: Tree-shaped pole body with bark coating and lightweight canopy, designed for scenic spots and residential communities with strict landscape requirements.
3.2 Classification by Fixing Method
- Counterweight Pole: Equipped with high-density concrete counterweight blocks at the base for non-penetrating installation, leaving building structures and waterproof layers intact. Ideal for rooftops with strict waterproof requirements.
- Anchored Pole: Rigidly connected to building main structures via expansion bolts or embedded parts for superior stability, applicable to load-bearing rooftops and ground surfaces.
- Guyed Pole: Fitted with high-tensile steel wire guys fixed to ground or walls for poles ≥8m tall, enhancing wind resistance stability.

Pole Production Workshop
3.3 Classification by Structural Form
- Single-tube Pole: Supported by a single steel pipe, simple structure and low cost. For loads ≤50kg and heights ≤4m.
- Diagonal Braced Pole: Triangular stable structure formed by main tube plus 2–3 diagonal braces with strong load capacity. Suitable for loads 50–150kg and heights 4–8m.
- Truss Pole: Spatial truss structure composed of main tube, cross arms and diagonal braces, delivering outstanding wind and seismic resistance. Designed for loads ≥150kg and heights ≥8m for 5G macro base stations.
3.4 Classification by Height Specification
- Short Pole (1–3m): For low-rise building rooftops and walls, carrying small 4G antennas.
- Medium Pole (3–6m): Universal specification for most urban rooftop 4G/5G base stations, supporting single or dual 5G antennas.
- Tall Pole (6–12m): For suburban ground and high-rise rooftops, capable of mounting multiple 5G Massive MIMO antennas.
3.5 Classification by Load Capacity
- Light-duty Pole: Rated load ≤50kg, for 4G micro base stations / 5G pico base stations.
- Medium-duty Pole: Rated load 50–150kg, for standard 5G base stations.
- Heavy-duty Pole: Rated load ≥150kg, for 5G macro base stations and high-capacity base stations.
4. System Schematic Diagrams

On-site Pole Installation Construction
4.1 Schematic of Rooftop Counterweight Pole (Low/Medium Configuration)
- Top section: Lightning rod (φ16–φ18mm × 500–600mm) → Adjustable antenna bracket → 4G/5G Antenna
- Middle section: Pole body (φ76–φ89mm hot-dip galvanized steel pipe) → RRU hanger → Feeder clamps → Diagonal braces (φ48mm steel pipe)
- Bottom section: Counterweight base (C30/C35 concrete, 500×500×200mm / 600×600×250mm) → Anti-slip rubber mat → Roof slab
- Lightning protection path: Lightning rod → Pole body → Galvanized flat steel (-40×4mm/-50×5mm) → Building earthing grid
4.2 Schematic of Ground Truss Pole (High-end Configuration)
- Top section: Lightning rod (φ20mm × 800mm) → Multi-layer adjustable antenna brackets → Multiple 5G Massive MIMO antennas
- Middle section: Main tube (φ159mm hot-dip galvanized steel pipe) → Cross arms (φ89mm steel pipe) → Diagonal braces (φ60mm steel pipe) → Equipment platform → RRUs / Power supply equipment
- Bottom section: Independent concrete foundation (C35 concrete, 1200×1200×600mm) → Embedded anchor bolts → Ground foundation
- Lightning protection path: Lightning rod → Main tube → Dual lightning down conductors (φ12mm round steel) → Ground electrodes (∠50×50×5mm angle steel) → Earth ground

Multi-view CAD Drawings of Pole Components
5. Full System Configuration Lists (Low / Medium / High Tier)
5.1 Low-tier Configuration List (Light-duty, 4G Base Station / 5G Micro Station, Load ≤50kg, Height ≤3m)
è¡¨æ ¼
| No. | Product Name | Model & Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Pole Body | KZ-BG-D1-3 | Q235B hot-dip galvanized steel pipe, φ76mm, wall thickness 4mm, height 3m, single-section flange connection, galvanized coating ≥80μm, wind resistance Level 8, seismic resistance Grade 7 | 1 | Set | KITOZER | Single-tube design without reinforcing ribs |
| 2 | Antenna Bracket | KZ-ZB-D1 | Q235B hot-dip galvanized steel pipe, φ48mm, length 1.2m, pitch angle 0°–90° adjustable, rated load 30kg | 1 | Set | KITOZER | Includes adjusting bolts and hoops |
| 3 | RRU Hanger | KZ-GJ-D1 | 5mm cold-rolled steel plate, hot-dip galvanized, fits 300×200mm RRUs, rated load 20kg | 1 | Set | KITOZER | With fixing bolts |
| 4 | Counterweight Base | KZ-PZ-D1 | C30 high-density concrete, 500×500×200mm, weight 120kg, equipped with anti-slip rubber mat | 1 | Block | KITOZER | Non-penetrating rooftop installation |
| 5 | Lightning Rod | KZ-LZ-D1 | 304 stainless steel, φ16mm, length 500mm, earthing resistance ≤10Ω | 1 | Piece | KITOZER | Top-mounted |
| 6 | Earthing Flat Steel | KZ-JD-D1 | Hot-dip galvanized flat steel -40×4mm, length 3m, with earthing terminals | 1 | Strip | KITOZER | Connects pole to building earthing grid |
| 7 | Feeder Clamp | KZ-KJ-D1 | Nylon material, compatible with 1/2″ feeders, V0 flame retardant grade, anti-aging | 4 | Piece | KITOZER | Feeder fixing |
| 8 | Anti-theft Bolt | KZ-LS-D1 | 304 stainless steel M12×50mm, tamper-proof design | 8 | Set | KITOZER | Component fastening |
5.2 Medium-tier Configuration List (Medium-duty, Standard 5G Base Station, Load 50–150kg, Height 3–6m)
è¡¨æ ¼
| No. | Product Name | Model & Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Pole Body | KZ-BG-M3-6 | Q355B hot-dip galvanized steel pipe, φ89mm, wall thickness 5mm, height 6m (2 flanged sections), galvanized coating ≥100μm with reinforcing ribs, wind resistance Level 10, seismic resistance Grade 8 | 1 | Set | KITOZER | Diagonally braced structure |
| 2 | Diagonal Brace | KZ-XC-M1 | Q355B hot-dip galvanized steel pipe, φ48mm, wall thickness 4mm, length 2.5m, flanged connections at both ends | 3 | Piece | KITOZER | Forms triangular stable structure |
| 3 | Antenna Bracket | KZ-ZB-M2 | Q355B hot-dip galvanized steel pipe, φ60mm, length 1.5m, 0°–90° pitch & full 360° azimuth adjustment, rated load 80kg | 2 | Set | KITOZER | Supports dual 5G antennas |
| 4 | RRU Hanger | KZ-GJ-M2 | 6mm cold-rolled steel plate, hot-dip galvanized, fits 400×250mm RRUs, rated load 50kg | 2 | Set | KITOZER | Equipped with shock-absorbing gaskets |
| 5 | Counterweight Base | KZ-PZ-M2 | C35 high-density concrete, 600×600×250mm, weight 180kg, anti-slip rubber mat + fixing hoops | 1 | Block | KITOZER | Matches 6m poles |
| 6 | Lightning Rod | KZ-LZ-M2 | 304 stainless steel, φ18mm, length 600mm, earthing resistance ≤8Ω with lightning ball cap | 1 | Piece | KITOZER | Enhanced lightning protection |
| 7 | Earthing Flat Steel | KZ-JD-M2 | Hot-dip galvanized flat steel -50×5mm, length 5m, earthing terminals + anti-corrosion coating | 1 | Strip | KITOZER | Improved lightning performance |
| 8 | Feeder Clamp | KZ-KJ-M2 | Flame-retardant ABS, compatible with 7/8″ feeders, UV & aging resistant | 8 | Piece | KITOZER | Evenly spaced installation |
| 9 | Camouflage Cover | KZ-MH-M1 | Fiberglass, air conditioner unit imitation shape, 800×600×300mm, waterproof & sun-proof | 1 | Set | KITOZER | Optional accessory |
| 10 | Anti-theft Bolt | KZ-LS-M2 | 304 stainless steel M14×60mm, tamper-proof & rust-resistant | 12 | Set | KITOZER | Fastens key structural components |
5.3 High-end Configuration List (Heavy-duty, 5G Macro Base Station, Load ≥150kg, Height 6–12m)
è¡¨æ ¼
| No. | Product Name | Model & Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Pole Body | KZ-BG-H6-12 | Q355B hot-dip galvanized steel pipe, φ159mm, wall thickness 6mm, height 12m (3 flanged sections), galvanized coating ≥120μm with dense reinforcing ribs, wind resistance Level 12, seismic resistance Grade 8 | 1 | Set | KITOZER | Truss-type structure |
| 2 | Cross Arm | KZ-HB-H1 | Q355B hot-dip galvanized steel pipe, φ89mm, wall thickness 5mm, length 2m, flanged ends, rated load 100kg | 2 | Piece | KITOZER | Multi-layer equipment mounting |
| 3 | Diagonal Brace | KZ-XC-H2 | Q355B hot-dip galvanized steel pipe, φ60mm, wall thickness 5mm, length 3.5m, high-strength flange connections | 4 | Piece | KITOZER | Spatial truss stability system |
| 4 | Antenna Bracket | KZ-ZB-H3 | Q355B hot-dip galvanized steel pipe, φ76mm, length 1.8m, precise pitch & azimuth adjustment, rated load 120kg | 4 | Set | KITOZER | Mounts multiple 5G Massive MIMO antennas |
| 5 | RRU Hanger | KZ-GJ-H3 | High-strength 8mm steel plate, hot-dip galvanized + dual anti-corrosion paint, fits 500×300mm RRUs, rated load 80kg | 4 | Set | KITOZER | Shock absorption & heat dissipation design |
| 6 | Equipment Platform | KZ-PT-H1 | 6mm patterned steel plate, hot-dip galvanized, 1000×800mm, rated load 200kg with protective railings | 1 | Set | KITOZER | Holds power supplies, optical transceivers & auxiliary equipment |
| 7 | Concrete Foundation | KZ-JC-H1 | C35 reinforced concrete, 1200×1200×600mm with internal steel mesh and embedded M24 anchor bolts | 1 | Set | KITOZER | Exclusive for ground installation |
| 8 | Lightning Rod | KZ-LZ-H3 | 316 stainless steel, φ20mm, length 800mm with lightning cap, earthing resistance ≤4Ω | 1 | Piece | KITOZER | Premium lightning protection grade |
| 9 | Lightning Down Conductor | KZ-YX-H1 | Hot-dip galvanized round steel φ12mm, length 12m, connects lightning rod to ground electrodes | 2 | Strip | KITOZER | Dual conductors for redundant lightning safety |
| 10 | Ground Electrode | KZ-JD-H3 | Galvanized angle steel ∠50×50×5mm, length 2.5m with earthing terminals | 4 | Piece | KITOZER | Driven underground to boost earthing performance |
| 11 | Feeder Clamp | KZ-KJ-H3 | High-tensile nylon, compatible with 1-5/8″ feeders, V0 flame retardant, wide temperature & aging resistance | 16 | Piece | KITOZER | Dense feeder fixing layout |
| 12 | Camouflage Cover | KZ-MH-H2 | High-strength fiberglass square column imitation, 1200×800×400mm, wind & UV resistant with long service life | 1 | Set | KITOZER | Matches macro base station dimensions |
| 13 | Anti-theft Bolt | KZ-LS-H3 | 316 stainless steel M16×70mm, high-strength tamper-proof & anti-rust | 16 | Set | KITOZER | Anti-theft fastening for core load-bearing parts |
| 14 | Intelligent Monitoring Module | KZ-JC-H1 | Tilt measurement ±15°, stress range 0–50kN, 4G wireless transmission, IP65 ingress protection | 1 | Set | KITOZER | Optional high-end add-on for real-time status alerting |
6. Full Product Technical Specifications
6.1 Pole Body Technical Parameters
è¡¨æ ¼
| Parameter | Low-tier (KZ-BG-D1-3) | Medium-tier (KZ-BG-M3-6) | High-end (KZ-BG-H6-12) |
|---|---|---|---|
| Material | Q235B Carbon Steel | Q355B Low-alloy High-strength Steel | Q355B Low-alloy High-strength Steel |
| Pipe Diameter | φ76mm | φ89mm | φ159mm |
| Wall Thickness | 4mm | 5mm | 6mm |
| Height | Customizable 1–3m | Customizable 3–6m | Customizable 6–12m |
| Connection Type | Single-section Flange Joint | 3m-per-section Flange Joint | 4m-per-section Flange Joint |
| Galvanized Coating Thickness | ≥80μm | ≥100μm | ≥120μm |
| Wind Resistance Grade | Level 8 (20.7m/s) | Level 10 (28.5m/s) | Level 12 (36.9m/s) |
| Seismic Resistance Grade | Grade 7 | Grade 8 | Grade 8 |
| Pole Deflection Limit | ≤L/200 | ≤L/250 | ≤L/300 (L = total pole height) |
| Service Life | ≥15 years | ≥20 years | ≥25 years |
| Surface Treatment | Hot-dip Galvanizing + Anti-corrosion Paint | Hot-dip Galvanizing + Anti-corrosion Paint | Hot-dip Galvanizing + Anti-corrosion Paint + Passivation Treatment |
6.2 Antenna Bracket Technical Parameters
è¡¨æ ¼
| Parameter | KZ-ZB-D1 | KZ-ZB-M2 | KZ-ZB-H3 |
|---|---|---|---|
| Material | Q235B Hot-dip Galvanized Steel Pipe | Q355B Hot-dip Galvanized Steel Pipe | Q355B Hot-dip Galvanized Steel Pipe |
| Pipe Diameter | φ48mm | φ60mm | φ76mm |
| Length | 1.2m | 1.5m | 1.8m |
| Pitch Adjustment Range | 0°–90° (Manual) | 0°–90° (Precision Manual) | 0°–90° (Calibrated Precision Adjustment) |
| Azimuth Adjustment | Fixed | Full 360° Manual Rotation | Full 360° Rotation with Locking Scale |
| Rated Load Capacity | 30kg | 80kg | 120kg |
| Anti-corrosion Process | Hot-dip Galvanizing | Hot-dip Galvanizing | Hot-dip Galvanizing + Anti-corrosion Paint |
| Adjustment Precision | ±2° | ±1° | ±0.5° |
6.3 RRU Hanger Technical Parameters
è¡¨æ ¼
| Parameter | KZ-GJ-D1 | KZ-GJ-M2 | KZ-GJ-H3 |
|---|---|---|---|
| Material | Cold-rolled Steel Plate | Cold-rolled Steel Plate | High-strength Steel Plate |
| Plate Thickness | 5mm | 6mm | 8mm |
| Compatible RRU Dimensions | 300×200mm | 400×250mm | 500×300mm |
| Rated Load Capacity | 20kg | 50kg | 80kg |
| Surface Treatment | Hot-dip Galvanizing | Hot-dip Galvanizing | Hot-dip Galvanizing + Anti-corrosion Paint |
| Extra Functions | None | Shock-absorbing Gaskets | Shock Absorption, Heat Dissipation Holes, Anti-rust Coating |
| Mounting Method | Bolt Fastening | Bolt Fastening | Bolt Fastening + Anti-loosening Design |
6.4 Counterweight Base / Concrete Foundation Technical Parameters
è¡¨æ ¼
| Parameter | KZ-PZ-D1/KZ-PZ-M2 | KZ-JC-H1 |
|---|---|---|
| Material | High-density C30/C35 Concrete | C35 Reinforced Concrete (Internal φ10mm Steel Mesh) |
| Dimensions (L×W×H) | Low-tier:500×500×200mm; Medium-tier:600×600×250mm | 1200×1200×600mm |
| Weight | Low-tier:120kg; Medium-tier:180kg | Approx. 2000kg |
| Accessories | 5mm-thick Anti-slip Rubber Mat | Built-in Steel Mesh + 4 Sets M24 Embedded Anchor Bolts |
| Installation Mode | Non-penetrating (Direct Roof Placement) | Ground Embedded (Cast-in-place Foundation) |
| Anti-overturning Coefficient | ≥1.5 | ≥2.0 |
6.5 Lightning Protection System Technical Parameters
è¡¨æ ¼
| Parameter | KZ-LZ-D1/M2/H3 | KZ-JD-D1/M2/H3 |
|---|---|---|
| Lightning Rod Material | 304 Stainless Steel (Low/Medium-tier); 316 Stainless Steel (High-end) | Hot-dip Galvanized Flat Steel / Round Steel / Angle Steel |
| Lightning Rod Specs | Low-tier: φ16×500mm; Medium-tier: φ18×600mm; High-end: φ20×800mm | Flat steel: -40×4mm/-50×5mm; Round steel: φ12mm; Angle steel: ∠50×50×5mm |
| Maximum Allowable Earthing Resistance | Low-tier ≤10Ω; Medium-tier ≤8Ω; High-end ≤4Ω | Low/Medium-tier ≤10Ω; High-end ≤4Ω |
| Anti-corrosion Grade | IP65 | IP65 |
| Compliance Standards | GB/T 21431-2015, YD/T 2187-2010 | GB/T 21431-2015, YD/T 2187-2010 |
6.6 Intelligent Monitoring Module Technical Parameters (Optional High-end Accessory)
è¡¨æ ¼
| Parameter | Technical Index |
|---|---|
| Tilt Measurement Range | ±15° |
| Tilt Measurement Precision | ±0.1° |
| Stress Measurement Range | 0–50kN |
| Stress Measurement Precision | ±1% Full Scale |
| Wireless Transmission | 4G Full-network Access |
| Power Supply | Solar Panel + Lithium Battery (Minimum 30-day Standby) |
| Ingress Protection Grade | IP65 |
| Customizable Alarm Thresholds | Tilt ≥5° / Stress ≥40kN |
7. Full Product Application Scope
7.1 Core Communication Base Station Scenarios

Intelligent Monitoring Command Center Platform
- 4G/5G Macro Base Stations: Deployed in suburban areas, counties and townships, mounting multiple 5G Massive MIMO antennas to deliver wide-area continuous coverage for three major telecom operators’ network construction.
- 4G/5G Micro Base Stations: Installed on high-rise rooftops, building walls and urban villages with compact small 5G antennas, eliminating signal blind zones, weak coverage and interference areas in dense cities to boost network capacity.
- Indoor Distribution Base Stations: Mounted on interior rooftops/walls of shopping malls, office towers, stadiums, airports and high-speed rail stations with indoor distributed antennas, improving indoor signal quality to support high-bandwidth services including 4K video, live streaming and mobile payments.
- Industry Private Network Base Stations: Customized communication poles for power, mining, rail transit, water conservancy, oil and other industrial private networks, compatible with dedicated industrial antennas to stabilize IoT, remote monitoring and emergency communication.
7.2 Urban Construction & Landscape Scenarios
- Residential Rooftops: Counterweight poles paired with camouflage covers disguised as air conditioning units or exhaust pipes, preserving community aesthetics while resolving residential signal coverage issues and reducing resident complaints.
- Scenic Spots, Parks & Cultural Tourism Zones: Bionic tree-shaped poles with bark coatings and lightweight fiberglass canopies that blend seamlessly with natural surroundings, enabling full-area signal coverage for tourist communications, live streaming and smart scenic management.
- Commercial Complexes & Office Towers: Rooftop/wall-mounted poles fitted with high-gain antennas to deliver ultra-high-speed 5G coverage supporting HD video conferencing, VR experiences and smart retail services.
- Municipal Roads & Transport Hubs: Co-mounted poles shared with streetlights and surveillance cameras to realize “multi-purpose single pole”, saving urban space and shortening construction cycles.
7.3 Special Environment Scenarios

Rooftop Pole with Dual 5G Antennas
- Mountainous & Remote Rural Areas: Tall ground poles with superior wind and seismic resistance to fill rural signal gaps, advancing communication infrastructure for rural revitalization and raising village 5G penetration rates.
- Factory Parks & Chemical Zones: Rooftop/ground poles with enhanced corrosion, dust and interference resistance to sustain stable industrial IoT, remote monitoring and production dispatching communications.
- Coastal & Salt-fog Regions: 316 stainless steel hardware plus thickened anti-corrosion coatings resist salt spray erosion, delivering a minimum 20-year service life for coastal and island base stations.
- High-altitude & Frigid Zones: Low-temperature resistant steel paired with freeze-proof anti-corrosion coatings operate reliably between -40°C and +60°C for highland and cold-climate base station deployments.
8. Full Product Competitive Advantages
8.1 Core Functional Features
- High-strength Load-bearing & Structural Stability: Medium/high-end models adopt Q355B low-alloy high-strength steel with sufficient wall thickness, reinforced ribs and truss designs. Resists Level 12 winds and Magnitude 8 earthquakes with maximum pole deflection ≤L/300, eliminating overturning and fracture risks under strong winds, snow loads and seismic activity.
- Multi-layer Anti-corrosion & Extended Service Life: Hot-dip galvanizing + anti-corrosion paint dual treatment (passivation added for high-end poles) with galvanized coating ≥80μm to withstand acid, alkali and UV degradation. Service life reaches ≥15 years (low-tier) and ≥25 years (high-end), minimizing long-term maintenance costs with extended maintenance-free cycles.
- Precision Adjustable & Universal Compatibility: Antenna brackets deliver 0°–90° pitch and full 360° azimuth adjustment with ±0.5° precision, compatible with all sizes and weights of 4G/5G antennas and RRUs. Supports single or multi-antenna layouts to meet varying network capacity requirements.
- Modular Design for Rapid Installation: Standardized modular components connected via flanges without on-site welding. Two workers can complete full assembly within 2 hours for short construction periods. Counterweight poles enable non-penetrating rooftop installation to avoid damaging waterproof layers and building structures, lowering construction risks and property coordination barriers.
- Reliable Lightning Protection & Safety Compliance: Standard stainless steel lightning rods, galvanized flat steel and down conductors; high-end models feature dual down conductors and ground electrodes with earthing resistance ≤4Ω, fully compliant with GB/T 21431-2015 standards to shield base station equipment from lightning strikes.
- Landscape Compatibility & Concealed Camouflage: Optional fiberglass camouflage enclosures (air conditioner / square column imitation) and tree bionic poles harmonize with urban and natural environments, reducing visual impact and resident opposition to base station construction.
- Intelligent Monitoring with Proactive Risk Alerts (High-end Only): Integrated tilt and stress sensors continuously monitor pole structural status and trigger automatic alerts for abnormal thresholds (tilt >5° / stress >40kN), enabling early hazard elimination and uninterrupted safe operation.
8.2 Customization & OEM/ODM Advantages

Urban Rooftop Installed 5G Pole
- Full-range Non-standard Customization: Customizable pole height (1–12m), pipe diameter (Φ76–Φ159mm), material grade (Q235B/Q355B/316 stainless steel), load capacity, color and appearance (bionic or camouflage enclosure). Custom design drawings delivered within 3 days based on site dimensions, equipment load, environmental conditions and landscape requirements for all special scenarios.
- OEM/ODM Contract Manufacturing Services: End-to-end OEM support including customer brand labeling, custom drawing development and process optimization. 10 years of communication steel structure processing experience with an annual output of 100,000 pole sets, guaranteeing short lead times and consistent quality.
- Confidentiality Agreements for Intellectual Property Protection: Formal non-disclosure agreements safeguard client design drawings, technical parameters and project data to prevent technology leakage and protect core client interests.
- Fast Delivery & In-stock Inventory: Standard specifications (3m / 6m single tube / diagonal braced poles) maintained in inventory with shipment within 3 days for urgent projects; custom orders delivered within 7–15 days, leading industry delivery efficiency.
8.3 Technical Parameter Superiorities Across Product Lines
- Material Upgrade: Medium/high-end Q355B steel delivers 30% higher tensile strength than Q235B, boosting load capacity and anti-deformation performance.
- Enhanced Corrosion Resistance: Passivation treatment on high-end poles improves anti-corrosion performance by 50%, ideal for coastal, salt-fog and chemical industrial zones.
- Superior Adjustment Precision: High-end antenna brackets achieve ±0.5° angular precision, 4x higher than conventional poles for ultra-accurate antenna pointing and optimized signal coverage quality.
- Dual Redundant Safety Design: High-end models use dual lightning down conductors plus four ground electrodes to lower earthing resistance to ≤4Ω, doubling lightning protection safety margin. Truss structures withstand Level 12 winds with sufficient safety redundancy for typhoon-prone coastal regions.
9. Bid-winning Control Parameters for Tender Documents (Key Specs Marked as Mandatory)
9.1 Mandatory Pole Body Bid Parameters
- Material: Low-tier Q235B carbon steel; Medium/High-end Q355B low-alloy high-strength steel, inferior steel prohibited
- Pipe Diameter: Low-tier ≥Φ76mm; Medium-tier ≥Φ89mm; High-end ≥Φ159mm
- Wall Thickness: Low-tier ≥4mm; Medium-tier ≥5mm; High-end ≥6mm
- Galvanized Coating Thickness: Low-tier ≥80μm; Medium-tier ≥100μm; High-end ≥120μm
- Wind Resistance Grade: Low-tier ≥Level 8; Medium-tier ≥Level 10; High-end ≥Level 12
- Seismic Resistance Grade: Medium/High-end ≥Grade 8; Low-tier ≥Grade 7
- Pole Deflection Limit: Medium-tier ≤L/250; High-end ≤L/300
- Minimum Service Life: Low-tier ≥15 years; Medium/High-end ≥20 years
9.2 Mandatory Antenna Bracket Bid Parameters
- Material: Medium/High-end ≥Q355B hot-dip galvanized steel pipe; Low-tier ≥Q235B hot-dip galvanized steel pipe
- Rated Load Capacity: Low-tier ≥30kg; Medium-tier ≥80kg; High-end ≥120kg
- Adjustment Range: 0°–90° pitch angle; full 360° azimuth rotation (Medium/High-end)
- Adjustment Precision: Medium-tier ≤±1°; High-end ≤±0.5°
9.3 Mandatory RRU Hanger Bid Parameters
- Material Plate Thickness: Low-tier ≥5mm; Medium-tier ≥6mm; High-end ≥8mm
- Rated Load Capacity: Low-tier ≥20kg; Medium-tier ≥50kg; High-end ≥80kg
- Surface Treatment: Hot-dip galvanizing + anti-corrosion paint (Medium/High-end)
9.4 Mandatory Lightning Protection System Bid Parameters
- Lightning Rod Material: Medium/High-end ≥304 stainless steel; High-end ≥316 stainless steel
- Maximum Allowable Earthing Resistance: Low-tier ≤10Ω; Medium-tier ≤8Ω; High-end ≤4Ω
- Compliance Standards: Fully compliant with GB/T 21431-2015 and YD/T 2187-2010
9.5 Mandatory Intelligent Monitoring Module Bid Parameters (Optional High-end Accessory)
- Tilt Measurement Precision: ≤±0.1°
- Stress Measurement Precision: ≤±1% Full Scale
- Customizable Alarm Thresholds: Tilt ≥5° / Stress ≥40kN
9.6 Mandatory Full System Bid Parameters
- Installation Method: Counterweight non-penetrating mounting that preserves building waterproof layers
- Modular Construction: No on-site welding required, fully bolt-assembled and installable by 1–2 workers
- Anti-corrosion Process: Hot-dip galvanizing + anti-corrosion paint dual treatment, passivation for high-end poles
- Ingress Protection Grade: All outdoor components meet minimum IP65 rating
10. Full Product Targeted Solutions
10.1 Rooftop Counterweight Pole Solution (Low/Medium-tier, Urban Signal Gap Filling)
- Applicable Scenarios: Dense residential compounds and office tower rooftops with limited space, strict waterproof requirements, requiring rapid deployment of 4G/5G micro or standard base stations with total equipment load ≤150kg.
- Core Solution: Single-tube or diagonally braced pole paired with counterweight base for non-penetrating rooftop installation to protect waterproof membranes. 360° adjustable antenna brackets deliver precise directional coverage; optional fiberglass air conditioner camouflage covers meet landscape aesthetic demands. Complete lightning protection earthing system with resistance ≤8Ω ensures full operational safety.
- Implementation Steps: Site survey → Custom design scheme → Rooftop surface preparation → Counterweight base placement → Pole assembly & fastening → Antenna/RRU mounting → Angular calibration → Lightning earthing connection → Acceptance & handover.
- Solution Advantages: Non-destructive rooftop installation, fast construction, low cost, landscape-friendly and simple maintenance, ideal for large-scale urban signal gap filling projects.
10.2 Ground Truss Pole Solution (High-end, 5G Macro Base Station)
- Applicable Scenarios: Suburban, township and mountain ground sites requiring mounting of ≥150kg multi-array 5G Massive MIMO antennas with stringent wind and seismic resistance demands for wide-area continuous coverage.
- Core Solution: Truss-type pole integrated with independent reinforced C35 concrete foundation with anti-overturning coefficient ≥2.0. Φ159mm main tube with 6mm wall thickness withstands Level 12 winds and Magnitude 8 earthquakes; multi-layer cross arms and four antenna bracket sets support four 5G antennas. Built-in equipment platform accommodates power supplies and optical transceivers. Dual lightning down conductors plus four ground electrodes achieve earthing resistance ≤4Ω, with optional intelligent monitoring modules for real-time structural alerting.
- Implementation Steps: Site topographic survey → Foundation excavation → Concrete pouring & 7-day curing period → Modular pole flange assembly → Lifting & base fastening → Cross arm/diagonal brace installation → Antenna/RRU mounting → Equipment platform fitting → Lightning protection construction → Intelligent monitoring calibration → Acceptance & handover.
- Solution Advantages: Ultra-high load capacity, exceptional structural stability, redundant lightning protection, intelligent health monitoring and extended service life, purpose-built for wide-area 5G macro base station deployments.
10.3 Wall-mounted Pole Solution (Low-tier, Space-limited Rooftop Scenarios)
- Applicable Scenarios: Building side walls with insufficient rooftop space to accommodate counterweight bases, mounting small 4G/5G antennas with total load ≤50kg.
- Core Solution: Single-tube wall-mounted pole with Φ76mm steel pipe and maximum height 4m. Secured to wall surfaces via heavy-duty mounting hoops and expansion bolts without occupying rooftop floor area. 1.2m antenna bracket with adjustable pitch angle; simplified lightning protection system with earthing resistance ≤10Ω, installable by one worker within one hour.
- Implementation Steps: Wall structural survey → Drilling positioning → Expansion bolt installation → Pole fastening → Antenna mounting → Angular adjustment → Lightning earthing connection → Acceptance & handover.
- Solution Advantages: Zero rooftop space occupation, ultra-fast installation, minimal capital cost and universal compatibility for rapid deployment in space-constrained building sites.
10.4 Bionic Pole Solution (Medium-tier, Scenic & High-landscape-demand Zones)
- Applicable Scenarios: National scenic spots, urban parks, cultural tourism districts and high-end residential compounds with strict landscape preservation standards, requiring fully concealed base station deployment that harmonizes with natural surroundings.
- Core Solution: Diagonally braced bionic pole shaped to mimic pine or banyan trees with textured bark coating and lightweight fiberglass canopies. Heights range 3–6m with Level 10 wind resistance; antennas are fully concealed within the canopy for zero visual intrusion. Counterweight non-penetrating base with complete lightning earthing system (resistance ≤8Ω).
- Implementation Steps: On-site landscape survey → Tree species selection matching local environment → Custom bionic pole manufacturing → Counterweight base placement → Pole fastening → Concealed antenna installation → Canopy assembly → Lightning earthing connection → Acceptance & handover.
- Solution Advantages: Perfect environmental integration, full visual concealment, landscape beautification and minimal resident/tourist complaints, tailored for high-aesthetic-value scenic and residential zones.
11. Full Product Application Case Studies
11.1 5G Signal Gap Filling Project in Tianhe District, Guangzhou (Medium-tier Counterweight Pole)
- Project Background: Dense high-rise residential blocks in Guangzhou Tianhe District suffered widespread 5G blind zones with strict rooftop waterproof protection rules. Dual 5G antennas (total load 120kg) required rapid deployment to boost residential coverage.
- Adopted Solution: KITOZER medium-tier 6m diagonally braced counterweight pole system with fiberglass air conditioner camouflage enclosures. 360° precision antenna brackets targeted residential coverage areas, lightning earthing resistance controlled below 8Ω.
- Project Outcomes: Deployed across 30 residential building rooftops within a 15-day construction window without a single waterproof damage complaint. Residential 5G coverage rate increased from 65% to 98% with peak download speeds reaching 500Mbps, earning full recognition from local telecom operators.
11.2 5G Macro Base Station Project in Mountainous Qingyuan, Guangdong (High-end Ground Truss Pole)
- Project Background: Remote mountainous terrain in Qingyuan with persistent Level 8–10 seasonal winds required a 5G macro base station carrying four Massive MIMO antennas (total load 200kg) to deliver coverage across 10 surrounding administrative villages.
- Adopted Solution: KITOZER high-end 12m truss ground pole with independent reinforced concrete foundation. Φ159mm main tube (6mm wall thickness) achieves Level 12 wind and Magnitude 8 seismic resistance, paired with dual lightning down conductors, four ground electrodes (earthing resistance ≤4Ω) and integrated intelligent structural monitoring modules.
- Project Outcomes: The base station has operated stably for 2 consecutive years without tilt, fracture or lightning failure incidents. Mountain village 5G coverage rate rose from 0% to 95%, meeting national administrative village 5G connectivity standards and receiving official commendation from local government and telecom carriers for supporting rural digital revitalization.
11.3 Bionic Pole Project at West Lake Scenic Area, Hangzhou (Medium-tier Bionic Pole)
- Project Background: West Lake National 5A Scenic Area enforced strict landscape conservation regulations, requiring concealed 5G base station deployment to support tourist mobile communications and 4K/8K cultural live streaming without disrupting natural aesthetics.
- Adopted Solution: KITOZER medium-tier 6m pine-shaped bionic pole with textured bark coating and lightweight fiberglass canopy, fully concealing antenna hardware. Non-penetrating counterweight base and fully compliant lightning earthing system matched scenic environmental requirements.
- Project Outcomes: 20 deployment points fully integrated with West Lake’s natural landscape without visitor complaints. Complete 5G coverage across the scenic area delivers peak download speeds up to 600Mbps to support high-definition live streaming services, receiving official approval from scenic area management authorities and positive tourist feedback.
11.4 Wall-mounted 5G Micro Station Project in Urban Villages, Shenzhen (Low-tier Wall Pole)
- Project Background: Dense urban village compounds in Shenzhen featured cramped rooftops and chaotic self-built auxiliary structures, requiring wall-mounted small 5G micro stations (single antenna weight 30kg) to eliminate severe indoor signal blind zones.
- Adopted Solution: KITOZER low-tier 3m single-tube wall-mounted pole with Φ76mm pipe, secured via heavy-duty wall hoops and expansion bolts. 1.2m adjustable pitch antenna bracket paired with simplified lightning protection system (earthing resistance ≤10Ω).
- Project Outcomes: Over 500 wall-mounted deployment points completed within a 1-month construction cycle without rooftop space occupancy disputes. Urban village 5G coverage rate improved from 50% to 97%, fully resolving resident poor signal complaints and winning favorable reviews from telecom operators and local residents.
12. Product Fault Troubleshooting & Maintenance Guidelines
12.1 Common Faults & Remedial Measures
è¡¨æ ¼
| Fault Phenomenon | Root Cause | Troubleshooting Solution |
|---|---|---|
| Excessive pole tilt (Inclination >5°) | 1. Counterweight base sliding/settlement; 2. Uneven foundation subsidence; 3. Loose diagonal brace bolts | 1. Realign counterweight base and reinforce anti-slip rubber mats; 2. Reinforce concrete foundation (high-end poles only); 3. Retorque diagonal brace bolts to specified torque (M14:45N·m) |
| Antenna azimuth/pitch angular drift | 1. Loose adjusting bolts; 2. Wind vibration-induced displacement; 3. Deformed mounting hanger | 1. Retighten adjusting bolts and install anti-loosening gaskets; 2. Quarterly angular recalibration for deviations exceeding 1°; 3. Replace permanently deformed hangers |
| Rust or fracture of fastener bolts | 1. Damaged anti-corrosion coating; 2. Humid/salt-fog operating environment; 3. Substandard bolt material grade | 1. Remove surface rust and reapply specialized galvanized anti-corrosion paint; fully corroded bolts replaced with 304/316 stainless steel hardware; 2. 3-monthly inspection cycle for coastal/salt-fog sites; 3. Upgrade to certified anti-theft stainless steel bolts |
| Failed lightning earthing system | 1. Broken flat steel/down conductors; 2. Corroded ground electrodes; 3. Loose connection terminals | 1. Replace fractured flat steel and down conductors; 2. Extract and replace corroded ground electrodes, re-drive into soil; 3. Retorque all connection points, apply conductive grease and retest earthing resistance to meet specified thresholds |
| Loose or damaged feeder cables | 1. Loose feeder clamps; 2. Wind vibration abrasion; 3. Aging cable insulation rupture | 1. Retighten clamps with uniform 1m mounting spacing; 2. Install protective cable sleeves to eliminate friction wear; 3. Replace aged feeders and fully waterproof cable joints |
| Intelligent monitoring module alarm (High-end Only) | 1. Tilt/stress values exceed preset thresholds; 2. Malfunctioning sensors; 3. Insufficient power supply | 1. Immediate structural inspection to eliminate tilt/overloading hazards; 2. Calibrate or replace faulty sensors; 3. Inspect solar panel cleanliness and lithium battery charge state, recharge or replace depleted batteries |
12.2 Routine Maintenance & Inspection Specifications
12.2.1 Mandatory Inspection Cycles
- Monthly Inspection: Check bolt torque tightness, anti-corrosion coating integrity, antenna angular alignment, feeder fixation and lightning connection continuity, log all measured data.
- Quarterly Inspection: Retest full-system earthing resistance, inspect counterweight/base settlement, calibrate intelligent monitoring sensors (high-end poles), clean accumulated dirt from antenna radomes.
- Annual Full Inspection: Comprehensive structural audit including weld integrity, pole deformation, load-bearing component strength and anti-corrosion coating thickness; issue formal annual equipment performance test reports.
- Emergency Post-extreme-weather Inspection: Full structural audit within 24 hours following typhoons, heavy rainstorms or seismic events to identify tilt, loose fasteners, component fracture or lightning strike damage and resolve hazards immediately.
12.2.2 Standard Maintenance Operating Protocols
- Bolt Torque Calibration: Use calibrated torque wrenches to retighten fasteners to standard torque values (M12:35N·m, M14:45N·m, M16:60N·m). Avoid hammer impact damage to bolt heads; ensure all anti-loosening gaskets are installed intact.
- Anti-corrosion Coating Repair: Immediately repair coating damage areas ≥5cm² by mechanical polishing to bare metal followed by two coats of galvanized specialized anti-corrosion paint (minimum 80μm dry film thickness). Coastal/salt-fog sites require inspection every 3 months; inland standard environments inspected every 6 months.
- Antenna Maintenance: Maintain clean antenna radomes free of dust and bird droppings using soft bristle brushes (abrasive hard tools prohibited). Recalibrate mounting structure if antenna gain deviation exceeds 1dB.
- Lightning Protection Maintenance: Full earthing resistance testing every quarter with corrective action for non-compliant values. Apply conductive grease to all metal connection terminals to prevent oxidation; inspect lightning rods for bending, rust or surface debris accumulation.
- Intelligent Monitoring Maintenance (High-end Only): Monthly review of real-time sensor data and precision recalibration as required. Clean solar panel surfaces and verify lithium battery charge level; recharge or replace batteries with insufficient standby capacity. Confirm stable wireless transmission and functional alarm triggering systems.
12.2.3 Maintenance Safety Protocols
- All high-altitude work requires certified safety harnesses and hard hats; all overhead operations suspended during winds ≥Level 6, heavy rain or thunderstorm lightning conditions.
- Cut power supply to base station equipment prior to maintenance to eliminate electric shock risks; lightning protection maintenance strictly prohibited during active thunderstorms.
- All replacement hardware (bolts, hangers, sensors) must be genuine KITOZER OEM components with identical material grades and specifications; mixed inferior third-party hardware forbidden.
13. Factory Production Strength & After-sales Service System
13.1 Factory Production Capacity & Technical Strength
KITOZER is a national high-tech enterprise integrating R&D, manufacturing, sales, installation and maintenance of communication steel infrastructure. Our 20,000㎡ manufacturing plant is located in Guangzhou, equipped with modern automated production workshops, precision processing machinery, dedicated technical engineering teams and a complete quality control system.
- Production Capacity: Fully automated production lines including CNC cutting machines, bending equipment, robotic welding stations, hot-dip galvanizing and anti-corrosion coating lines. Annual output reaches 100,000 complete pole sets and 50,000 tons of communication steel components, supporting rapid delivery for large-scale national network construction projects.
- Technical R&D Team: 30 dedicated R&D engineers including 5 senior structural engineers, 8 steel structure designers and 5 communications industry specialists with over 10 years of communication tower design experience. Participated in drafting multiple national and industrial communication infrastructure standards, holding 20 independent intellectual property patents (5 invention patents, 15 utility model patents).
- Full-spectrum Quality Control: Certified ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System. Full quality audit covering raw material incoming inspection, in-process production monitoring and finished product factory testing. Every pole undergoes mechanical load testing, anti-corrosion coating inspection and lightning performance verification; non-compliant products are prohibited from factory shipment.
- Industry Engineering Experience: 10 years of dedicated communication infrastructure manufacturing serving China Mobile, China Telecom, China Unicom, China Tower and government, scenic area and industrial park clients. Successfully delivered over 10,000 complete base station pole projects across 30 provincial-level administrative regions with consistent industry-wide positive market reputation.
13.2 Full Lifecycle After-sales Service Commitment
KITOZER delivers end-to-end full-lifecycle after-sales support covering design, manufacturing, installation, commissioning and long-term maintenance to guarantee seamless project implementation and stable long-term pole operation.
- Warranty Policy: All product lines carry a standard 5-year manufacturer warranty covering free component repair and replacement for non-human-induced structural defects. Lifetime post-warranty maintenance service available with only component material cost charged (no labor or on-site service fees).
- 24/7 Professional Technical Support: Round-the-clock telephone, WeChat and remote video technical consultation to rapidly resolve client engineering challenges. Free custom design drawings, complete installation CAD schematics and professional operator training (online live courses + on-site hands-on training) covering full installation, commissioning and maintenance workflows.
- Nationwide Professional Installation Team: Certified full-time installation crews available for national on-site deployment with efficient 1–2 person construction workflows guaranteeing installation compliance and structural safety. Complex high-end macro base station projects include dedicated on-site construction supervisors to manage safety, schedule and quality control.
- Rapid Emergency Response Mechanism: 2-hour initial response window for all fault service requests, with formal technical troubleshooting solutions issued within 2 hours. On-site engineering dispatch within 48 hours for urban sites; extended to 72 hours for remote mountainous rural regions to minimize base station downtime.
- Scheduled Customer Follow-up Service: Quarterly proactive client follow-up calls to monitor equipment operating status, collect feedback and provide customized maintenance recommendations. Free annual full structural safety inspection for all high-end truss pole systems to eliminate hidden structural risks proactively.
14. Conclusion
As core supporting infrastructure for communication networks, the KITOZER 4G/5G base station pole system addresses critical pain points of conventional pole products including insufficient load capacity, rapid corrosion, building structural damage during installation, landscape visual conflict and high long-term maintenance costs. Equipped with high-strength load-bearing performance, multi-layer anti-corrosion protection, precision angular adjustment, modular rapid assembly, redundant lightning protection, landscape camouflage and optional intelligent structural monitoring, the full product portfolio fully meets all construction scenarios including urban signal gap filling, rural wide-area coverage, scenic area aesthetic deployment and industrial private network communication.
Backed by robust factory manufacturing capacity, professional engineering R&D teams, strict standardized quality control and comprehensive full-lifecycle after-sales support, KITOZER provides customized turnkey solutions, premium certified hardware and complete service packages to accelerate large-scale nationwide 4G/5G network deployment. Our products deliver solid infrastructure support for smart city construction, digital economy development and rural digital revitalization initiatives.
Moving forward, KITOZER will continue deepening investment in communication steel structure R&D to drive product technical innovation, optimize targeted industry solutions and upgrade end-to-end client service quality. We aim to establish long-term win-win partnerships with global clients to jointly advance high-quality development of 5G and next-generation communication infrastructure.
15. Search Keywords, SEO Tags & Product Classification Labels
15.1 Core & Long-tail Search Keywords
- Core Keywords: 4G base station pole, 5G base station pole, base station antenna pole, rooftop base station pole, communication pole
- Long-tail Keywords: Counterweight base station pole, diagonally braced base station pole, truss base station pole, bionic base station pole, wall-mounted base station pole, 5G macro base station pole, 5G micro base station pole, base station pole manufacturer, KITOZER base station pole
15.2 SEO Optimization Meta Tags
- Title Tag: KITOZER 4G/5G Base Station Pole | Rooftop Counterweight / Ground Truss / Bionic Communication Antenna Support System
- Meta Description Tag: KITOZER specializes in full-series 4G/5G base station pole systems including rooftop counterweight poles, ground truss poles, bionic landscape poles and wall-mounted poles. High-strength anti-corrosion construction withstands Level 12 winds and Magnitude 8 earthquakes. Customized turnkey solutions direct from factory with reliable quality and comprehensive after-sales service.
- Meta Keywords Tag: 4G base station pole, 5G base station pole, base station antenna pole, rooftop base station pole, counterweight base station pole, bionic base station pole, KITOZER
15.3 Website Product Classification & Attribute Labels
- Category Labels: Communication Infrastructure, Base Station Support System, Base Station Pole, Antenna Bracket
- Attribute Labels: 4G/5G Compatible, High Load-bearing Strength, Hot-dip Galvanized Anti-corrosion, Modular Rapid Installation, Reliable Lightning Protection, Landscape Camouflage, Customizable Specification, Intelligent Structural Monitoring