KITOZER
KITOZER

KITOZER 4G/5G Integrated Base Station Cabinet Solution

Table of Contents

1. System Overview

The KITOZER integrated base station cabinet is a highly integrated, modular and intelligent comprehensive equipment cabinet independently developed for outdoor deployment scenarios of 4G/5G mobile communication base stations. Integrating structural engineering, precision temperature control, intelligent power distribution, environmental sensing and remote operation & maintenance technologies, it integrates equipment carrying, power supply guarantee, precise temperature control, environmental monitoring and safety protection as a whole. It can completely replace traditional civil machine rooms to realize rapid “zero machine room” deployment of base stations, serving as the core infrastructure for cost reduction, efficiency improvement and energy saving in 5G infrastructure construction.

The system adopts an independent physical isolation design with dual cabins (equipment cabin + battery cabin), which thoroughly isolates heat sources and power supply interference. It adapts to extreme outdoor environments ranging from -40°C to +60°C, with an Ingress Protection rating of IP55 (IP56 for high-end equipment cabins). It features dustproof, waterproof, salt-fog resistant, anti-aging, earthquake and wind resistant capabilities (withstanding wind speeds up to 50m/s), and has passed a 1000-hour salt spray test, ensuring a service life of more than 10 years in coastal high-salt-fog environments. Equipped with KITOZER self-developed intelligent environment monitoring system, it can real-time monitor more than 400 operating parameters including temperature & humidity, access control, smoke detection, water immersion, voltage & current and vibration. It supports 4G/5G dual-link remote alarm and intelligent management with fault response time ≤10 seconds and MTBF ≥50000 hours, realizing unattended operation and maintenance.

Integrated Base Station Cabinet in Mountain Area

Compared with traditional machine rooms, the KITOZER integrated cabinet reduces floor space by 70%, shortens deployment cycle by 80%, cuts energy consumption by 50%-85% with PUE ≤1.2, and saves more than 10,000 RMB in electricity bills per station annually. It supports flexible assembly of single, dual and multiple cabinets, adapting to various complex scenarios such as urban rooftops, roadside areas, mountainous regions, scenic spots, expressway/railway lines, rural and suburban areas. It fully meets deployment demands of 4G/5G macro stations, micro stations, edge computing nodes and co-location construction, facilitating the development of green and low-carbon communication networks.

2. System Composition

The KITOZER integrated base station cabinet system consists of six core modules: cabinet structure module, power supply system module, temperature control system module, environmental monitoring system module, safety protection system module, and wiring & accessory system module. All modules adopt standardized interfaces, prefabricated and debugged in factories for rapid on-site assembly and plug-and-play deployment.

2.1 Cabinet Structure Module

Cabinet Dimension Drawing

  • Material Specifications: 1.5-2.0mm hot-dip galvanized steel plate with double-layer heat insulation design filled with 50mm thick high-density PUEPS thermal insulation layer, thermal conductivity ≤0.472W/(m²·K). The surface undergoes three anti-corrosion treatments: degreasing, phosphating and electrostatic plastic spraying, delivering anti-ultraviolet and anti-corrosion performance.
  • Cabin Design: Standard dual independent sealed cabins (equipment cabin + battery cabin) for physical isolation of heat sources and power supplies. The equipment cabin is equipped with a standard 19-inch rack supporting installation of 19U-42U equipment. Single-cabinet models fit micro stations while multi-cabinet models support expansion.
  • Protection Performance: Overall IP55 protection grade (IP56 for high-end equipment cabins). Silicone sealing strips and glue dispensing process achieve waterproof and dustproof effects. Anti-theft three-point lock plus internal hidden screws comply with GA/T73-1994 Grade B anti-damage standards.
  • Dimensions & Load-bearing: Standard models: 650×650×1200mm (entry-level), 800×800×1800mm (mid/high-end); customized sizes available. Base load capacity ≥1000kg (entry-level)/≥2000kg (mid-end)/≥3000kg (high-end), seismic resistance conforming to YD5083/YD5096 Grade 9 seismic standards.

2.2 Power Supply System Module

  • AC Power Distribution: Optional AC220V/380V input, with automatic dual-city power switching (high-end version). B+C grade lightning protection (20kA+10kA), multi-protection against overvoltage, overcurrent, electric leakage, phase loss and surge. Equipped with intelligent electricity meter for real-time municipal power parameter monitoring.
  • DC Power Supply: 48V high-frequency switching power supply with optional capacity from 50A to 200A, embedded 19-inch rack design, efficiency ≥92%-96%. It supports intelligent charge-discharge management of storage batteries and automatic conversion between equal and floating charging to extend battery service life.
  • Backup Batteries: Valve-regulated lead-acid batteries (entry/mid-end) / lithium iron phosphate batteries (high-end), supporting 1-4 hours backup duration. Single-layer load capacity ≥300kg, with reinforced battery cabin to prevent vibration displacement.
  • UPS (High-end Version): Online UPS with double conversion design, efficiency ≥95%, SNMP interface and large LCD screen display to guarantee uninterrupted power supply for loads with 1-hour backup time.

2.3 Temperature Control System Module

Cabinet Production Workshop

  • Natural Heat Dissipation (Entry-level): Top exhaust fans plus side air intake shutters for natural convection heat dissipation, equipped with detachable dust filter screens for easy cleaning and maintenance. Applicable ambient temperature range: -10℃ ~ +40℃ with zero extra power consumption.
  • Intelligent Heat Exchanger (Mid-end): High-efficiency heat exchanger with heat exchange capacity of 80W/K-190W/K, DC48V power supply, isolated cold and hot air flow and non-condensation design for energy-saving and high efficiency. Applicable temperature range: -30℃ ~ +50℃, meeting most outdoor scenarios.
  • Variable Frequency Precision Air Conditioner (High-end): Variable frequency industrial air conditioner with cooling capacity of 300W-2000W, dual power supply of DC48V/AC220V, redundant dual cold source design and no condensation. Precise temperature control at 25℃±2℃ with humidity controlled below 95%, adapting to extreme environments from -40℃ to +60℃.
  • Independent Temperature Control: Separate temperature control for equipment cabin and battery cabin. The battery cabin is standard-equipped with TEC semiconductor refrigeration module to accurately maintain the optimal operating temperature of 25℃±5℃ and extend battery service life.

2.4 Environmental Monitoring System Module

  • Core Monitoring Unit: KITOZER environment monitoring host, 19-inch 1U rack-mounted, industrial CPU, 512M memory and 8G storage. Supports TCP/IP and SNMP protocols with 4G/5G dual-link remote transmission (high-end version).
  • Monitoring Sensors: Temperature & humidity sensors (accuracy ±0.3℃~±0.5℃, ±2%RH~±3%RH), access control sensors (standard door contact/biometric identification), smoke sensors, water immersion sensors (electrode/cable type), voltage/current sensors and vibration sensors.
  • Control Functions: Intelligent start-stop of air conditioners/fans, linkage based on temperature & humidity thresholds, remote access control, alarm linkage (acoustic & local light alarm + APP/SMS/phone alarm). Supports storage, query, export and analysis of historical data (storage ≥1 year).

2.5 Safety Protection System Module

On-site Cabinet Installation & Commissioning

  • Lightning Protection & Grounding: Grade B lightning protection (AC side) + dedicated battery lightning protection (DC side), grounding copper bar resistance ≤0.1Ω to prevent equipment damage from lightning strikes, complying with YD/T1235.1-2002 lightning protection standards.
  • Fire Fighting & Fire Suppression: Suspended aerosol fire extinguishing device (mid-end) / heptafluoropropane device (high-end), automatically activated linked with smoke detection, leaving no residue, pollution or corrosion to rapidly contain fires.
  • Anti-theft & Anti-damage: Vibration sensor plus door contact alarm; high-end version supports biometric access control (fingerprint + password + IC card), real-time remote monitoring and access record query to prevent equipment theft or sabotage.
  • Flame Retardant & Insulation: Internal cables adopt flame retardant materials with cabinet insulation resistance ≥2MΩ to avoid short-circuit fires. All electrical clearances and creepage distances conform to GB4943.1-2011 standards.

2.6 Wiring & Accessory System Module

  • Cable Management Unit: Special cable routing columns on both rear sides of the cabinet, 19-inch cable management frame, independent cable inlet holes for power lines, signal lines and optical cables to separate wiring and avoid interference. Cables with clear labels for convenient maintenance.
  • Power Distribution Accessories: 16A 8-position national standard PDU (standard/intelligent version), horizontally installed with redundant power output. Intelligent PDU supports remote power management, independent switch control and current monitoring.
  • Lighting Unit: DC-48V LED lighting (standard/high-brightness), door-contact linked switch, low power consumption and long service life (≥50000h), with emergency lighting function (high-end version).
  • Installation Accessories: 19-inch equipment trays, equipment fixing brackets, battery anti-theft brackets, seismic connecting pieces, grounding bolts and special fasteners, complying with YD5083 seismic standards.

3. System Classification

Cabinet Exploded Structural Drawing

The KITOZER integrated base station cabinet is classified into five dimensions by cabin structure, heat dissipation mode, configuration grade, deployment scale and application scenario, fully covering different scenarios, budgets and functional requirements for targeted adaptation.

3.1 Classification by Cabin Structure

  • Single-cabinet Integrated Cabinet: Single-cabinet integrated layout with equipment and batteries co-located, compact structure, size 650×650×1200mm, floor area ≤0.5㎡ for convenient deployment. Suitable for micro stations, marginal networks, small base stations and rural coverage sites.
  • Dual-cabinet Separated Cabinet: Standard independent separated equipment cabin and battery cabin with physical isolation of heat sources and power supplies, independent sealing and separate temperature control, size 800×800×1800mm with ample space and efficient heat dissipation. Suitable for macro stations, medium & large base stations and urban core area sites.
  • Multi-cabinet Combined Cabinet: Modular assembly of 3 or more cabins (equipment cabin + battery cabin + transmission/power/backup cabin) with expanded space and clear functional zoning. Supports multi-equipment co-location, edge computing nodes, super macro stations and flexible capacity expansion for co-site construction scenarios.

3.2 Classification by Heat Dissipation Mode

  • Natural Heat Dissipation Cabinet: Top exhaust fans plus side air intake shutters without refrigeration equipment for zero energy consumption and optimal cost performance. Applicable to mild climate regions (-10℃ ~ +40℃), low-power micro stations and rural/suburban sites.
  • Heat Exchange Cabinet: Integrated high-efficiency heat exchanger with isolated cold and hot air flow and non-condensation design for energy saving and high efficiency. Applicable to most outdoor scenarios (-30℃ ~ +50℃), medium-power base stations, roadside/rooftop/scenic spot sites, balancing performance and energy consumption.
  • Air Conditioner Refrigeration Cabinet: Integrated variable frequency precision air conditioner with redundant dual cold sources and precise temperature control. Applicable to extreme high/low temperature environments (-40℃ ~ +60℃), high-power macro stations and coastal/plateau/desert/cold region sites for stable operation under harsh conditions.

3.3 Classification by Configuration Grade

Single Micro Station Cabinet

  • Entry-level Basic Type: Basic cabinet + natural heat dissipation + simple power distribution + basic monitoring, meeting fundamental equipment bearing and environmental monitoring needs with low budget. Suitable for rural, suburban and remote mountain micro stations and marginal network coverage sites.
  • Mid-end Standard Type: Dual-cabinet cabinet + heat exchange heat dissipation + intelligent power distribution + full-parameter monitoring + basic fire fighting, balancing performance and cost. Suitable for urban roadside, rooftop, residential community, scenic spot and expressway line conventional base stations.
  • High-end Enhanced Type: Thickened cabinet + air conditioner refrigeration + UPS power supply + redundant monitoring + intelligent fire fighting + remote management, fully configured with high reliability. Suitable for core urban areas, expressway/railway lines, coastal/plateau extreme environments, edge computing nodes and critical macro stations.

3.4 Classification by Deployment Scale

  • Single Cabinet Deployment: One independent cabinet integrating all equipment, floor area ≤0.5㎡ with deployment time ≤1 day. Suitable for small base stations, marginal networks, micro stations and rural coverage sites.
  • Dual Cabinet Deployment: Two spliced cabinets (equipment cabinet + battery cabinet) with larger space, better heat dissipation and stronger load capacity. Suitable for medium macro stations, high-power base stations and urban dense area sites.
  • Multi-cabinet Deployment: Modular assembly of 3 or more cabinets supporting multi-equipment co-location, load dispersion and function expansion. Suitable for large macro stations, co-location sites, edge computing nodes, super base stations and front-end data center nodes.

3.5 Classification by Application Scenario

Remote Monitoring Platform Control Room

  • Urban Macro Station Dedicated Cabinet: High-end enhanced type with thickened dual-cabinet cabinet, air conditioner refrigeration, redundant power supply and full-parameter monitoring. Adapted to urban core areas, dense buildings and high-power macro stations with high reliability requirements.
  • Rural/Mountain Micro Station Dedicated Cabinet: Entry-level basic type with compact single-cabinet cabinet and natural heat dissipation. Adapted to remote rural areas, mountainous regions and scenic spots for low-cost rapid coverage and convenient deployment.
  • Expressway/Railway Line Dedicated Cabinet: Mid-end standard type with dual-cabinet cabinet and heat exchange heat dissipation plus enhanced protection. Adapted to environments with large temperature differences, heavy sand wind and strong vibration, featuring salt-fog resistance and vibration stability.
  • Coastal/Extreme Environment Dedicated Cabinet: High-end enhanced type with thickened anti-corrosion cabinet and air conditioner refrigeration plus enhanced protection. Adapted to coastal high-salt-fog, plateau cold, desert high-temperature environments with over 10 years anti-corrosion performance and stable operation under extreme conditions.
  • Edge Computing Dedicated Cabinet: High-end multi-cabinet type with expandable multi-cabinet layout, redundant power supply, precision air conditioner and intelligent monitoring. Adapted to edge computing nodes, industrial outdoor equipment rooms and front-end data center nodes for high integration, high power consumption and high reliability demands.

4. System Schematic Diagrams

4.1 Overall Architecture Schematic

Municipal power input → AC power distribution unit (lightning protection/protection/switching) → High-frequency switching power supply (rectification/voltage stabilization/battery management) → DC power distribution unit (distribution/protection) → Loads (BBU/RRU/transmission equipment/edge computing equipment)

Storage battery bank connected in parallel with DC bus for seamless power switching upon municipal power outage to guarantee uninterrupted load power supply

Temperature control system (air conditioner/heat exchanger/fan/TEC module) independently powered, with temperature & humidity sensors triggering intelligent start-stop of equipment, separate temperature control for dual cabins

Environment monitoring host real-time collects parameters of all modules (temperature & humidity/access control/smoke/water immersion/voltage & current/vibration), uploads data to monitoring platform via 4G/5G, supporting remote control, alarm push and intelligent linkage

4.2 Power Supply System Schematic

AC220V/380V Municipal Power → Dual-circuit switching switch (high-end) → B+C grade lightning arrester → AC power distribution cabinet (air switch/electricity meter/protection device) →

High-frequency switching power supply (N rectifier modules + 1/2 monitoring modules) → DC bus (48V) →

├─ Storage battery bank (parallel connection, charge-discharge management/BMS protection)

└─ DC power distribution cabinet (air switch/fuse/electricity meter/protection device) → PDU (standard/intelligent) → Load Equipment

4.3 Temperature Control System Schematic

Temperature & Humidity Sensors (Equipment Cabin/Battery Cabin) → Environment Monitoring Host → Temperature Control Controller →

├─ Equipment Cabin: Variable Frequency Air Conditioner/Heat Exchanger/Fan (intelligent start-stop based on temperature thresholds)

└─ Battery Cabin: TEC Semiconductor Refrigeration Module/Independent Fan (maintaining optimal temperature of 25℃±5℃)

4.4 Monitoring System Schematic

Sensor Group (Temperature & Humidity/Access Control/Smoke/Water Immersion/Voltage & Current/Vibration) → Environment Monitoring Host (Data Collection/Processing/Storage) →

├─ Local Display (LCD Touch Screen/Indicator Lights)

├─ Acoustic & Local Light Alarm (On-site Fault Reminder)

└─ 4G/5G Remote Transmission → Monitoring Platform/APP/SMS/Phone (Remote Management/Alarm Push/Data Query)

4.5 Fire Fighting Linkage Schematic

Smoke Sensor (Top of Equipment Cabin) → Environment Monitoring Host → Fire Extinguishing Controller →

├─ Acoustic & Local Light Alarm (Fire Reminder)

└─ Suspended Fire Extinguishing Device (Aerosol/Heptafluoropropane) → Automatic Fire Suppression (Residue-free & Pollution-free)

5. Complete System Configuration List (Entry/Mid/High-end Classification)

5.1 Entry-level Basic Type Configuration List

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Integrated Base Station Cabinet (Single Cabin)KITOZER-C6512650×650×1200mm, 1.5mm hot-dip galvanized steel plate, IP55, single cabin, 19-inch 19U rack, base load ≥1000kg, 50mm insulation layer, natural heat dissipation1SetKITOZERBasic model for micro stations
2AC Power Distribution UnitKITOZER-AC63AC220V±15%, 63A air switch, Grade B lightning protection (20kA), overcurrent/leakage protection, IP401SetKITOZERIncludes lightning arrester, air switch, terminal blocks
3High-frequency Switching Power SupplyKITOZER-PS485048V/50A, embedded 19-inch 1U, efficiency ≥92%, automatic equal/float charge conversion, RS485 interface, MTBF≥50000h1SetKITOZER1 rectifier module + 1 monitoring module
4Valve-regulated Lead-acid BatteryKITOZER-B12-10012V100Ah, maintenance-free, sealed leak-proof, operating temp 0-40℃, internal resistance ≤5mΩ, flame retardant shell4PcsKITOZERSeries-connected for 48V, 1-hour backup
5DC Power Distribution UnitKITOZER-DC482048V input, 4×20A output circuits, overcurrent protection, reverse connection prevention, IP401SetKITOZERIncludes air switches, fuses, terminal blocks
6Cabinet PDU (Standard)KITOZER-PDU160816A, 8 national standard sockets, 19-inch 1U, flame retardant shell, IP401PcsKITOZERRack-mounted installation
7Natural Heat Dissipation Fan GroupKITOZER-FAN120120×120×38mm, DC48V, 0.3A, 2800rpm, 120CFM, ≤50dB, top-mounted with dust filter4PcsKITOZERNatural convection heat dissipation
8Environment Monitoring Host (Basic Version)KITOZER-MON-B19-inch 1U, industrial CPU, supports temperature/humidity/access control/voltage monitoring, RS485 interface, local LCD display, DC48V power supply1SetKITOZERBasic parameter monitoring, no remote transmission
9Temperature & Humidity Sensor (Standard)KITOZER-TH-STemp -40℃~+80℃ (±0.5℃), Humidity 0-100%RH (±3%RH), DC48V, RS485 output1PcsKITOZERInstalled in equipment cabin
10Access Control Sensor (Standard)KITOZER-DO-SDoor contact switch, DC48V, NO/NC optional, switching value output1PcsKITOZERInstalled on cabinet door
11LED Lighting (Standard)KITOZER-LED-48DC48V, 10W, door-contact linked switch, service life ≥50000h1SetKITOZERInternal cabinet installation
12Grounding Copper Bar (Standard)KITOZER-EB-5050×5mm, tin-plated copper, grounding resistance ≤0.1Ω, anti-corrosion treatment1StripKITOZERInstalled at cabinet bottom

5.2 Mid-end Standard Type Configuration List

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Integrated Base Station Cabinet (Dual Cabin)KITOZER-C8018800×800×1800mm, 1.8mm hot-dip galvanized steel plate, IP55, dual cabin (equipment+battery), 19-inch 30U rack, base load ≥2000kg, 50mm high-density insulation layer, heat exchange cooling1SetKITOZERStandard model for macro stations
2AC Power Distribution UnitKITOZER-AC100Optional AC220V/380V, 100A air switch, B+C grade lightning protection (20kA+10kA), overvoltage/overcurrent/leakage/phase loss protection, intelligent electricity meter, IP401SetKITOZERIncludes lightning arrester, air switch, electricity meter, indicator lights
3High-frequency Switching Power SupplyKITOZER-PS4810048V/100A, embedded 19-inch 3U, efficiency ≥95%, automatic equal/float charge conversion, battery charge management, SNMP interface, MTBF≥50000h1SetKITOZER2 rectifier modules + 1 monitoring module
4Valve-regulated Lead-acid BatteryKITOZER-B12-15012V150Ah, maintenance-free, sealed leak-proof, operating temp -10℃~45℃, internal resistance ≤4.5mΩ, flame retardant shell, cycle life ≥500 times4PcsKITOZERSeries-connected for 48V, 2-hour backup
5DC Power Distribution UnitKITOZER-DC484048V input, 6×40A output circuits, overcurrent/short-circuit/reverse connection protection, intelligent power monitoring, IP401SetKITOZERIncludes air switches, fuses, terminal blocks, electricity meter
6Cabinet PDU (Standard)KITOZER-PDU160816A, 8 national standard sockets, 19-inch 1U, flame retardant shell, redundant design, IP402PcsKITOZERRack-mounted, 1 front + 1 rear
7Heat ExchangerKITOZER-HE150Heat exchange capacity 150W/K, DC48V, power 80W, non-condensation design, applicable -30℃~+50℃, energy-saving & high efficiency1SetKITOZERInstalled in equipment cabin, independent temperature control
8TEC Semiconductor Refrigeration ModuleKITOZER-TEC200Cooling capacity 200W, DC48V, power 100W, precise temp control 25℃±5℃, low power consumption, dedicated for battery cabin1SetKITOZERInstalled in battery cabin to stabilize battery temperature
9Environment Monitoring Host (Standard Version)KITOZER-MON-S19-inch 1U, industrial CPU, 512M memory, 8G storage, supports temp/humidity/access control/smoke/water immersion/voltage & current monitoring, 4G remote transmission, APP/SMS alarm, SNMP protocol, DC48V power supply1SetKITOZERFull parameter monitoring & remote management
10Temperature & Humidity Sensor (Standard)KITOZER-TH-STemp -40℃~+80℃ (±0.5℃), Humidity 0-100%RH (±3%RH), DC48V, RS485 output2PcsKITOZER1 for equipment cabin, 1 for battery cabin
11Access Control Sensor (Standard)KITOZER-DO-SDoor contact switch, DC48V, NO/NC optional, switching value output2PcsKITOZER1 for front door, 1 for rear door
12Smoke SensorKITOZER-SM-SPhotoelectric type, DC48V, sensitivity compliant with GB4715, switching value alarm output1PcsKITOZERMounted on top of equipment cabin
13Water Immersion Sensor (Electrode Type)KITOZER-WL-SElectrode type, DC48V, 5m detection distance, switching value alarm output1SetKITOZERInstalled at cabinet bottom
14LED Lighting (Standard)KITOZER-LED-48DC48V, 10W, door-contact linked switch, service life ≥50000h2SetKITOZER1 for equipment cabin, 1 for battery cabin
15Grounding Copper Bar (Standard)KITOZER-EB-5050×5mm, tin-plated copper, grounding resistance ≤0.1Ω, anti-corrosion treatment1StripKITOZERInstalled at cabinet bottom
16Aerosol Fire Extinguishing DeviceKITOZER-FG66KG suspended type, automatically triggered linked with smoke detection, residue-free & pollution-free, protected volume ≤10m³, operating temp -20℃~+60℃1SetKITOZERMounted on top of equipment cabin

5.3 High-end Enhanced Type Configuration List

表格

Finished Cabinet Studio Shot

  • Model: KITOZER-C6512 (Entry) / C8018 (Mid) / C8018H (High)
  • Dimensions (W×D×H): 650×650×1200mm (Entry) / 800×800×1800mm (Mid/High)
  • Material: 1.5mm hot-dip galvanized steel (Entry) /1.8mm (Mid) /2.0mm thickened (High), double-layer 50mm PUEPS thermal insulation
  • Ingress Protection: IP55 overall, IP56 equipment cabin (High-end), salt spray test ≥1000 hours
  • Cabin Structure: Single cabin (Entry) / Dual independent sealed cabins (Mid/High: Equipment + Battery)
  • Mounting Rack: Standard 19-inch rack, 19U (Entry) /30U (Mid) /42U (High)
  • Load Capacity: Base ≥1000kg (Entry) /≥2000kg (Mid) /≥3000kg (High)
  • Environmental Adaptability: Operating temp -40℃~+60℃, humidity ≤95%RH (@+40℃), altitude ≤4000m
  • Seismic Grade: Compliant with YD5083/YD5096, Grade 9 seismic resistance (High-end)
  • Wind Resistance: Withstands wind speed up to 50m/s, anti-aging service life ≥10 years

6.2 AC Power Distribution Unit

  • Model: KITOZER-AC63 (Entry) / AC100 (Mid) / AC160 (High)
  • Input Voltage: AC220V±15% (Entry) / Optional AC220V/380V (Mid/High), wide voltage AC90-290V
  • Rated Current: 63A (Entry) /100A (Mid) /160A (High)
  • Lightning Protection Grade: Grade B (Entry) / B+C (Mid/High, 20kA+10kA), response time <25ns
  • Protection Functions: Overcurrent, leakage (Entry); Overvoltage/overcurrent/leakage/phase loss (Mid); Overvoltage/overcurrent/leakage/phase loss/surge + automatic dual-power switching (High)
  • Operating Temperature: -20℃~+60℃
  • Protection Grade: IP40

6.3 High-frequency Switching Power Supply

  • Model: KITOZER-PS4850 (Entry) / PS48100 (Mid) / PS48200 (High)
  • Input Voltage: AC220V±15%, 50Hz, wide voltage AC90-290V
  • Output Voltage: DC48V (adjustable 42V-60V)
  • Rated Current: 50A (Entry) /100A (Mid) /200A (High)
  • Conversion Efficiency: ≥92% (Entry) /≥95% (Mid) /≥96% (High)
  • Battery Management: Automatic equal/float charge conversion (Entry); Intelligent charge management (Mid); Intelligent management + module redundancy (High)
  • Monitoring Interface: RS485 (Entry) / SNMP (Mid/High)
  • Operating Temperature: -30℃~+50℃
  • MTBF: ≥50000h

6.4 Storage Batteries

6.4.1 Valve-regulated Lead-acid Battery

  • Model: KITOZER-B12-100 (Entry) / B12-150 (Mid)
  • Rated Voltage: 12V
  • Rated Capacity: 100Ah (Entry) /150Ah (Mid)
  • Operating Temperature: 0-40℃ (Entry) /-10℃~45℃ (Mid)
  • Cycle Life: ≥500 cycles (100% discharge)
  • Internal Resistance: ≤5mΩ (Entry) /≤4.5mΩ (Mid)
  • Shell: Flame retardant ABS, sealed leak-proof, anti-corrosion

6.4.2 Lithium Iron Phosphate Battery

  • Model: KITOZER-LFP48200 (High-end)
  • Rated Voltage: 48V
  • Rated Capacity: 200Ah
  • Operating Temperature: -20℃~60℃
  • Cycle Life: ≥2000 cycles (80% discharge)
  • Protection Functions: BMS full protection against overvoltage/overcurrent/short-circuit/temperature anomaly
  • Internal Resistance: ≤2mΩ
  • Shell: Metal housing, waterproof dustproof, seismic reinforcement

6.5 Temperature Control Equipment

6.5.1 Natural Heat Dissipation Fan Group

  • Model: KITOZER-FAN120
  • Operating Voltage: DC48V
  • Power: 14.4W (0.3A)
  • Rotation Speed: 2800±100rpm
  • Air Volume: 120CFM
  • Noise: ≤50dB
  • Operating Temperature: -10℃~+40℃

6.5.2 Heat Exchanger

  • Model: KITOZER-HE150
  • Heat Exchange Capacity: 150W/K
  • Operating Voltage: DC48V
  • Power Consumption: 80W
  • Applicable Temp Range: -30℃~+50℃
  • Non-condensation Design: Supported
  • Operating Temperature: -30℃~+50℃

6.5.3 Variable Frequency Precision Air Conditioner

  • Model: KITOZER-AC1500
  • Cooling Capacity: 1500W
  • Power Supply: Dual DC48V/AC220V
  • Rated Cooling Power: 500W
  • Temperature Control Accuracy: 25℃±2℃
  • Humidity Control Limit: ≤95%RH
  • Redundant Cold Source: Dual cold source with standby backup
  • Operating Temperature: -40℃~+60℃

6.5.4 TEC Semiconductor Refrigeration Module

  • Model: KITOZER-TEC200
  • Cooling Capacity: 200W
  • Operating Voltage: DC48V
  • Power Consumption: 100W
  • Temperature Control Accuracy: 25℃±5℃
  • Operating Temperature: -20℃~+40℃

6.6 Environment Monitoring Host

  • Model: KITOZER-MON-B (Entry) / MON-S (Mid) / MON-H (High)
  • Hardware Specs: 19-inch 1U, industrial CPU, 512M memory, 8G storage
  • Monitored Parameters: Temp/humidity/access control/voltage (Entry); Temp/humidity/access control/smoke/water immersion/voltage & current (Mid); Temp/humidity/access control/smoke/water immersion/voltage & current/vibration/air conditioner status (High)
  • Transmission Mode: RS485 (Entry) /4G (Mid) /4G+5G dual transmission (High)
  • Alarm Method: Local LCD prompt (Entry) / APP + SMS (Mid) / APP + SMS + phone call (High)
  • Supported Protocols: Custom private protocol (Entry) / SNMP (Mid) / SNMP + TCP/IP (High)
  • Linkage Control: None (Entry) / Air conditioner/fan automatic linkage (Mid) / Full equipment intelligent linkage (High)
  • Historical Data Storage: No storage (Entry) / ≥6 months (Mid) / ≥1 year (High)
  • Operating Temperature: -30℃~+60℃
  • Power Supply: DC48V

6.7 Sensors

6.7.1 Temperature & Humidity Sensor

  • Model: KITOZER-TH-S (Standard) / TH-H (High Precision)
  • Temperature Range: -40℃~+80℃ (Standard) / -40℃~+85℃ (High Precision)
  • Temperature Accuracy: ±0.5℃ (Standard) / ±0.3℃ (High Precision)
  • Humidity Range: 0-100%RH
  • Humidity Accuracy: ±3%RH (Standard) / ±2%RH (High Precision)
  • Power Supply: DC48V
  • Output Signal: RS485/Analog
  • Protection Grade: IP65

6.7.2 Access Control Sensor

  • Model: KITOZER-DO-S (Standard) / DO-H (Biometric)
  • Type: Door contact switch (Standard) / Fingerprint + Password + IC Card (High-end)
  • Power Supply: DC48V
  • Output Signal: Switching value (Standard) / Network digital signal (High-end)
  • Access Record Storage: None (Standard) / 1000 records (High-end)
  • Protection Grade: IP54

6.7.3 Smoke Sensor

  • Model: KITOZER-SM-S
  • Type: Photoelectric smoke detection
  • Power Supply: DC48V
  • Sensitivity: Compliant with GB4715 national standard
  • Output: Switching value alarm signal
  • Operating Temperature: -10℃~+50℃
  • Protection Grade: IP54

6.7.4 Water Immersion Sensor

  • Model: KITOZER-WL-S (Electrode) / WL-H (Cable)
  • Type: Electrode contact type (Standard) / Positioning cable type (High-end)
  • Power Supply: DC48V
  • Detection Distance: 5m (Electrode) /20m (Cable)
  • Output: Switching value alarm signal
  • Protection Grade: IP67

6.7.5 Vibration Sensor

  • Model: KITOZER-VB-S
  • Type: Piezoelectric vibration detection
  • Power Supply: DC48V
  • Sensitivity: Adjustable
  • Output: Switching value alarm signal
  • Operating Temperature: -20℃~+60℃
  • Protection Grade: IP54

6.8 Fire Extinguishing Equipment

6.8.1 Aerosol Fire Extinguishing Device

  • Model: KITOZER-FG6
  • Spec: 6KG suspended type
  • Activation Mode: Automatic linkage trigger with smoke sensor
  • Extinguishing Medium: Aerosol, residue-free, non-polluting & non-corrosive
  • Protected Volume: ≤10m³
  • Operating Temperature: -20℃~+60℃
  • Activation Response Time: ≤3 seconds

6.8.2 Heptafluoropropane Fire Extinguishing Device

  • Model: KITOZER-FM12
  • Spec: 12KG suspended type
  • Activation Mode: Automatic linkage trigger with smoke sensor
  • Extinguishing Medium: Eco-friendly heptafluoropropane, residue-free
  • Protected Volume: ≥20m³
  • Operating Temperature: -20℃~+60℃
  • Activation Response Time: ≤3 seconds

6.9 Other Accessories

6.9.1 Cabinet PDU

  • Model: KITOZER-PDU1608 (Standard) / PDU1608S (Intelligent)
  • Rated Voltage: AC220V
  • Rated Current: 16A
  • Output Interfaces: 8 national standard AC sockets
  • Intelligent Functions: None (Standard) / Remote power management, independent circuit switch, real-time current monitoring (Intelligent)
  • Protection Grade: IP40
  • Operating Temperature: -10℃~+50℃

6.9.2 LED Lighting

  • Model: KITOZER-LED-48 (Standard) / LED-48H (High Brightness)
  • Operating Voltage: DC48V
  • Power: 10W (Standard) /18W (High Brightness)
  • Control Mode: Linked door contact switch
  • Service Life: ≥50000h
  • Protection Grade: IP54

6.9.3 Grounding Copper Bar

  • Model: KITOZER-EB-50 (Standard) / EB-60 (Thickened)
  • Spec: 50×5mm (Standard) /60×6mm (Thickened)
  • Material: Tin-plated pure copper
  • Grounding Resistance: ≤0.1Ω
  • Anti-corrosion Treatment: Tin plating for anti-rust & anti-oxidation

7. Full Product Application Scope

7.1 Integrated Base Station Cabinet

  • Communication Base Station Scenarios: 4G/5G macro stations, micro stations, marginal network stations, super macro stations, co-location construction, edge computing nodes
  • Deployment Coverage: Urban rooftops, roadside greenbelts, mountainous areas, scenic spots, expressway/railway lines, rural suburbs, coastal islands, plateaus, deserts and frigid regions
  • Extended Scenarios: Outdoor mini data centers, photovoltaic power stations, wind farms, power distribution cabinets, ETC gantries, smart communities, industrial outdoor equipment rooms, emergency communication stations, disaster relief temporary machine rooms

7.2 AC Power Distribution Unit

  • Compatible Cabinets: Integrated base station cabinets, outdoor intelligent cabinets, communication power cabinets, industrial outdoor control cabinets
  • Power Supply Scenarios: AC220V/380V outdoor power access, municipal power input for base stations, photovoltaic/wind power grid-connected power distribution, emergency power supply distribution, industrial outdoor equipment power supply

7.3 High-frequency Switching Power Supply

  • Communication Base Station Scenarios: 4G/5G macro/micro/marginal stations, edge computing nodes, outdoor communication mini machine rooms
  • Compatible Cabinets: Integrated outdoor cabinets, power cabinets, transmission cabinets, industrial control cabinets
  • Powered Loads: Storage battery charging, DC power supply for BBU/RRU/transmission/edge computing equipment, industrial DC power systems, emergency DC backup power

7.4 Storage Batteries

  • Base Station Backup Power: 4G/5G integrated cabinet emergency power supply, uninterrupted operation during municipal power outages
  • Standby Power Scenarios: UPS backup power, industrial equipment standby power, emergency lighting power, communication equipment reserve power
  • Energy Storage Extension: Photovoltaic off-grid energy storage, wind power energy storage, outdoor micro-grid storage, emergency energy storage power stations

7.5 Temperature Control Equipment

  • Cabinet Thermal Management: Integrated communication cabinets, outdoor intelligent cabinets, power cabinets, industrial control cabinets, outdoor mini data center cooling
  • Equipment Heat Dissipation: BBU/RRU heat dissipation, battery constant temperature control, precision outdoor electronic equipment cooling
  • Ambient Temperature Regulation: Outdoor equipment room constant temperature, extreme high/low temperature environment thermal management for coastal/plateau/desert sites

7.6 Environment Monitoring Host

  • Base Station Monitoring: 4G/5G integrated cabinet power & environment monitoring, unattended base station management
  • Outdoor Machine Room Monitoring: Container machine rooms, edge data centers, emergency communication equipment rooms
  • Remote O&M: Multi-site centralized monitoring, remote equipment fault diagnosis, predictive maintenance, fault early warning

7.7 Sensors

  • Environmental Monitoring: Cabinet/machine room temperature, humidity, water immersion and smoke anomaly early warning
  • Security Monitoring: Cabinet door access control, anti-prying vibration alarm, illegal intrusion detection
  • Equipment Operation Monitoring: Power voltage/current, air conditioner operating status, real-time equipment health tracking & fault pre-alert

7.8 Fire Extinguishing Equipment

  • Cabinet Fire Protection: Integrated communication cabinets, industrial outdoor control cabinet fire suppression
  • Outdoor Machine Room Fire Fighting: Container machine rooms, equipment rooms, emergency communication sites
  • Electronic Equipment Protection: Fire suppression for BBU/RRU, batteries, transmission servers and edge computing hardware with residue-free extinguishing medium

8. Core Product Advantages

8.1 Integrated Base Station Cabinet Core Strengths

  1. Superior Extreme Environment Adaptability: Operates stably from -40℃ to +60℃, IP55 (IP56 high-end) protection grade, salt-fog & UV resistance, anti-aging, anti-seismic & anti-wind (50m/s wind resistance). Passed 1000-hour salt spray test with over 10-year service life in coastal high-salt-fog areas, covering all harsh outdoor environments including plateaus, deserts and cold zones.
  2. High Integration for Cost & Efficiency Optimization: Integrates power supply, temperature control, monitoring and fire fighting to replace traditional civil machine rooms. Cuts floor space by 70%, shortens deployment cycle by 80%, reduces energy consumption by 50%-85% with PUE ≤1.2, saving over 10,000 RMB electricity cost per station annually and drastically lowering infrastructure & operation expenses.
  3. Modular Flexible Capacity Expansion: Single/dual/multi-cabinet modular assembly with standard 19-inch rack, compatible with mainstream communication hardware from Huawei, ZTE and Ericsson. Supports rapid expansion and flexible combination, covering full scenarios from micro stations to super macro stations without secondary reconstruction during upgrades.
  4. Intelligent Unattended Remote O&M: 4G/5G dual-link environment monitoring tracks over 400 operating parameters with 10-second fault alarm response. Remote management via APP/SMS/phone with historical data traceability improves predictive maintenance accuracy and cuts O&M labor cost by 60% through “data transmission replacing on-site inspections”.
  5. Military-grade High Reliability: Military-standard manufacturing with MTBF ≥50000 hours, thickened steel double reinforcement, Grade 9 seismic resistance and 50m/s wind resistance. Fully sealed dust/water/corrosion protection ensures 10-year stable operation without critical failures.
  6. Full Customization Service Support: Customizable cabinet dimensions, internal layout, functional modules and exterior colors; OEM/ODM confidential processing with non-disclosure agreements. Standard models stocked for fast delivery to shorten project lead time.
  7. One-stop Full-series Supply: Complete product portfolio including cabinets, power supplies, thermal control, monitoring, fire fighting and accessories for unified procurement, reducing communication and purchasing costs with integrated after-sales service guarantee.

8.2 Power Supply System Advantages

  1. Stable Uninterrupted Power Supply: High-frequency power supply efficiency ≥95% with automatic equal/float charge conversion. High-end lithium batteries equipped with BMS protection realize seamless municipal/battery power switching to eliminate base station downtime risks.
  2. Wide Voltage Adaptation for Unstable Grid: AC input range AC90-290V tolerates severe outdoor grid voltage fluctuations, preventing hardware damage caused by abnormal power voltage.
  3. Intelligent Battery Management Extends Service Life: Temperature-compensated intelligent charging automatically switches equal and float charge modes; high-end lithium iron phosphate batteries deliver ≥2000 charge-discharge cycles, 3-4 times longer than conventional lead-acid batteries and slashing battery replacement costs.
  4. Redundant Fault-tolerant Design: High-end power systems adopt redundant rectifier modules plus UPS backup with automatic fault switching to eliminate single-point failures. Multi-stage lightning protection and full overvoltage/overcurrent/short-circuit/reverse connection protection ensure power safety.
  5. Energy-saving Low Loss Design: ≥95% power conversion efficiency outperforms traditional power supplies by over 20% energy saving; adaptive load sleep mode minimizes no-load power loss to cut long-term electricity expenditure.

8.3 Temperature Control System Advantages

  1. Dual-cabinet Independent Precision Thermoregulation: Separate temperature control for equipment cabin (25℃±2℃) and battery cabin (25℃±5℃) matches optimal operating temperatures for communication hardware and batteries respectively to extend overall equipment lifespan.
  2. Three-tier Energy-saving Cooling Solution: Entry-level zero-power natural ventilation, mid-end energy-efficient heat exchangers, high-end extreme-environment air conditioners enable customers to balance cooling performance and operational costs based on site conditions.
  3. Redundant Cooling Without Single Point Failure: High-end air conditioners feature dual cold source redundancy with standby TEC refrigeration modules; backup fans automatically activate upon air conditioner failure to prevent overheating equipment shutdown.
  4. Non-condensation Design for Hardware Safety: Heat exchangers and precision air conditioners eliminate internal cabinet condensation, avoiding short circuits and metal corrosion caused by accumulated water vapor inside the cabinet.
  5. Ultra-wide Temperature Adaptation: Operates reliably across -40℃ to +60℃ to stabilize cabinet temperature in high-temperature, low-temperature, high-humidity and large temperature difference harsh outdoor environments.

8.4 Environment Monitoring System Advantages

  1. Blind-spot-free Full-parameter Monitoring: Real-time tracking of temperature/humidity, access control, smoke, water immersion, voltage/current, vibration and air conditioner operating status covering all cabinet critical operating indicators.
  2. Efficient Remote Unattended O&M: 4G/5G dual-link data transmission with triple alarm channels (APP/SMS/phone) and 10-second fault response. Remote control of air conditioners, fans and cabinet locks cuts on-site O&M workload by 80%.
  3. Traceable Historical Data Analysis: Minimum 1-year storage of operational data supporting query, export and statistical analysis for fault troubleshooting, O&M optimization and equipment performance evaluation.
  4. Automatic Intelligent Linkage Disposal: Temperature thresholds trigger fan/air conditioner auto start-stop; smoke sensors activate fire suppression devices automatically to contain faults with minimal manual intervention and reduce failure impact scope.
  5. Industrial-grade Anti-interference Hardware: Industrial components operate stably from -30℃ to +60℃ with strong anti-electromagnetic interference, lightning resistance and vibration resistance, MTBF ≥50000 hours for long-term outdoor deployment.

8.5 Safety Protection System Advantages

  1. Multi-stage Lightning Surge Protection: Combined B+C grade lightning protection plus dedicated DC-side battery lightning protection with grounding copper bar resistance ≤0.1Ω, fully complying with industry lightning protection standards to shield equipment from lightning surge damage.
  2. Rapid Intelligent Fire Suppression: Aerosol/heptafluoropropane extinguishing devices auto-trigger within 3 seconds upon smoke detection with residue-free, non-corrosive medium to rapidly contain fires and prevent fire spread.
  3. Multi-layer Anti-theft & Sabotage Prevention: High-end biometric access control paired with vibration sensors and door contact alarms enable real-time remote intrusion monitoring with complete access record storage, preventing communication equipment theft and damage.
  4. Flame Retardant Insulation Against Short-circuit Hazards: All internal wiring uses flame retardant materials with cabinet insulation resistance ≥2MΩ; electrical clearances and creepage distances fully meet national standards to eliminate short-circuit fire and electric shock risks.

8.6 Customization & Integrated Service Advantages

  1. In-depth Customization Capability: Custom cabinet dimensions, plate thickness, functional modules, internal layout and exterior color; special customization for explosion-proof, heavy anti-corrosion and enhanced seismic requirements to satisfy differentiated project demands.
  2. Confidential OEM/ODM Manufacturing: Full OEM/ODM production with signed non-disclosure agreements protecting customer design drawings, technical parameters and proprietary information, supporting private brand labeling.
  3. Stock Fast Delivery: Mass inventory of standard entry/mid/high-end models for quick order shipment; priority production scheduling for urgent construction projects to shorten delivery lead time.
  4. One-stop Integrated Procurement: Complete product portfolio covering cabinets, power, cooling, monitoring and fire fighting to eliminate multi-supplier communication and comparison workloads, lowering overall procurement costs.
  5. Full Lifecycle Professional Technical Support: Pre-sales site survey and customized solution design, in-sales installation guidance and commissioning training, 7×24-hour after-sales remote technical support and on-site service.
  6. Long-term Warranty & Lifelong Maintenance: 3-year free product warranty with free repair and component replacement for non-human damage within warranty period; lifelong technical consultation, spare parts supply and system upgrade services for long-term customer support.

9. Tender Control Technical Parameters (Marked with *)

9.1 Integrated Base Station Cabinet

*1. Cabinet Material: ≥1.8mm hot-dip galvanized steel plate, double-layer thermal insulation with ≥50mm thick insulation layer, thermal conductivity ≤0.472W/(m²·K), surface treated by degreasing, phosphating and electrostatic plastic spraying triple anti-corrosion process.

*2. Protection Grade: Overall IP55 protection, IP56 equipment cabin (high-end), salt spray test duration ≥1000 hours with full dustproof, waterproof and anti-corrosion performance.

*3. Cabin Structure: Independent dual cabin layout (equipment cabin + battery cabin) with physical heat/power isolation, separate sealed compartments and independent temperature control for each cabin.

*4. Load Capacity: Base static load ≥2000kg (mid-end) / ≥3000kg (high-end), seismic performance compliant with YD5083/YD5096 Grade 9 seismic standards.

*5. Environmental Adaptability: Operating temperature range -40℃~+60℃, maximum relative humidity ≤95%RH (@40℃), maximum altitude 4000m, wind resistance up to 50m/s.

*6. Dimension Specs: Standard overall dimension 800×800×1800mm, customizable sizes, standard 19-inch rack with ≥30U installation space.

9.2 AC Power Distribution Unit

*1. Input Voltage: Optional AC220V/380V wide input range AC90-290V to adapt to unstable outdoor municipal power grids.

*2. Lightning Protection Grade: B+C composite lightning protection with nominal discharge current ≥20kA+10kA, response time <25ns, complying with YD/T1235.1-2002 industry standard.

*3. Full Protection Functions: Equipped with overvoltage, overcurrent, leakage, phase loss and surge protection; high-end version supports automatic dual-circuit municipal power switching with complete protection logic.

*4. Rated Current: ≥100A (mid-end) / ≥160A (high-end), sufficient capacity to support high-power 5G communication equipment power demand.

9.3 High-frequency Switching Power Supply

*1. Input Voltage: AC220V±15%, 50Hz mains frequency, wide voltage operating range AC90-290V for unstable outdoor power grids.

*2. Output Specs: Adjustable DC48V output (42V-60V), rated output current ≥100A (mid-end) / ≥200A (high-end) to meet high current demand of 5G hardware.

*3. Conversion Efficiency: ≥95% (mid-end) / ≥96% (high-end) for energy-saving low-loss operation to reduce long-term site power consumption.

*4. Monitoring Interface: Native SNMP protocol support with 4G remote monitoring, enabling remote parameter configuration and real-time operating status query.

*5. Reliability Index: MTBF ≥50000 hours with industrial-grade stability for long-term unattended outdoor operation.

9.4 Storage Batteries

*1. Valve-regulated Lead-acid Battery (Mid-end): 12V150Ah maintenance-free design, operating temperature range -10℃~45℃, minimum 500 charge-discharge cycles, flame retardant ABS shell.

*2. Lithium Iron Phosphate Battery (High-end): 48V200Ah integrated battery pack, ≥2000 charge-discharge cycles under 80% discharge depth, operating temperature -20℃~60℃, full BMS overvoltage/overcurrent/short-circuit/temperature protection.

*3. Backup Duration: Minimum 2-hour emergency power backup (mid-end) / minimum 4-hour backup (high-end) to sustain full site operation during extended municipal power outages.

9.5 Temperature Control Equipment

*1. Heat Exchanger: Minimum heat exchange capacity 150W/K, DC48V power supply, non-condensation structural design, stable operation from -30℃ to +50℃ with low energy consumption.

*2. Variable Frequency Precision Air Conditioner: Minimum cooling capacity 1500W, dual DC48V/AC220V power supply, redundant dual cold source system, temperature control accuracy ±2℃, stable operation from -40℃ to +60℃.

*3. TEC Semiconductor Refrigeration Module: Minimum cooling capacity 200W, DC48V power supply, temperature control accuracy ±5℃, dedicated for battery cabin constant temperature maintenance to optimize battery service life.

9.6 Environment Monitoring Host

*1. Full-parameter Monitoring: Supports comprehensive collection of temperature/humidity, access control, smoke, water immersion, voltage/current, vibration and air conditioner operating status with no monitoring blind spots.

*2. Remote Data Transmission: 4G/5G dual redundant transmission (high-end), native SNMP and TCP/IP protocol support for stable remote data upload.

*3. Multi-channel Alarm & Data Storage: Triple alarm modes of APP, SMS and phone call, minimum 1-year historical operating data storage with full data query, export and statistical analysis functions.

*4. Intelligent Automatic Linkage: Supports automatic linkage between temperature thresholds and cooling equipment, smoke detection and fire suppression devices for autonomous fault disposal without manual intervention.

9.7 Sensors

*1. High-precision Temperature & Humidity Sensor: Temperature measurement accuracy ±0.3℃, humidity measurement accuracy ±2%RH, DC48V power supply, waterproof dustproof IP65 protection grade.

*2. High-end Water Immersion Sensor: Cable positioning type with minimum 20m detection length, capable of pinpointing water leakage positions, switching value alarm output, IP67 waterproof protection.

*3. High-end Access Control Sensor: Three-in-one biometric identification (fingerprint + password + IC card), remote access authorization, storage of minimum 1000 access records for security audit.

9.8 Fire Extinguishing Equipment

*1. Aerosol Fire Extinguishing Device: 6KG suspended type, auto-triggered linked with smoke sensors, activation response time ≤3 seconds, residue-free non-corrosive extinguishing medium.

*2. Heptafluoropropane Fire Extinguishing Device: 12KG suspended eco-friendly type, auto-triggered by smoke detection, protected space volume ≥20m³, activation response time ≤3 seconds with zero residual pollution to electronic equipment.

10. Complete Product Solution Packages

10.1 Full-scenario 4G/5G Macro Station Solution

  • Applicable Scenarios: Urban core areas, suburban counties and industrial parks with high-power macro stations requiring high reliability and unattended long-term operation, large equipment quantity and high power consumption.
  • Configuration Package: KITOZER-C8018H high-end thickened dual-cabinet cabinet + AC160 AC power distribution + PS48200 high-frequency power supply + LFP48200 lithium iron phosphate battery + AC1500 variable frequency precision air conditioner + MON-H enhanced environment monitoring host + FM12 heptafluoropropane fire suppression device + full set of high-precision sensors + intelligent PDU + seismic connecting fittings
  • Solution Highlights: Independent redundant dual-cabinet cooling maintains stable equipment temperature at 25℃±2℃; 4-hour lithium battery backup realizes seamless power switching during municipal power failure; 5G remote intelligent monitoring triggers fault alarms within 10 seconds for fully unattended O&M; Grade 9 seismic resistance plus IP56 heavy protection guarantees stable operation under extreme environments; full high-end configuration delivers ultra-high reliability for long-term high-power 5G macro station deployment.

10.2 Low-cost Rural/Mountain 5G Micro Station Coverage Solution

  • Applicable Scenarios: Remote villages, mountainous scenic spots and towns with low-power micro stations, tight budget limits, fast deployment requirements and simplified maintenance demands for signal blind spot coverage.
  • Configuration Package: KITOZER-C6512 entry-level single-cabinet cabinet + AC63 AC power distribution + PS4850 high-frequency power supply + B12-100 lead-acid battery + FAN120 natural ventilation cooling + MON-B basic environment monitoring host + standard basic sensors
  • Solution Highlights: Compact single-cabinet design occupies floor space ≤0.5㎡ with single-site deployment cycle ≤1 day for plug-and-play commissioning; zero-power natural ventilation eliminates ongoing cooling electricity cost; basic monitoring meets core environmental safety demands with optimal overall cost performance; drastically reduces site construction investment to rapidly resolve rural mountain 5G coverage blind spots with minimal capital expenditure.

10.3 High-stability Expressway/Railway Line Solution

  • Applicable Scenarios: Expressway/railway corridors, bridge and tunnel entrances with complex variable environments featuring large temperature differences, heavy sand wind, salt fog and continuous vibration requiring superior anti-corrosion and anti-vibration stability.
  • Configuration Package: KITOZER-C8018 mid-end dual-cabinet cabinet + AC100 AC power distribution + PS48100 high-frequency power supply + B12-150 lead-acid battery + HE150 high-efficiency heat exchanger + MON-S standard environment monitoring host + FG6 aerosol fire suppression device + full set of standard sensors
  • Solution Highlights: IP55 anti-corrosion salt-fog resistant cabinet withstands sand wind and coastal salt fog erosion; energy-saving heat exchanger non-condensation cooling adapts to large daily temperature fluctuations along transportation corridors; 2-hour battery backup ensures uninterrupted communication along traffic lines; 4G remote monitoring realizes unattended remote O&M; reinforced anti-vibration structural design eliminates equipment failure caused by vehicle/train vibration for consistent long-term signal coverage.

10.4 High-reliability Coastal/Plateau Extreme Environment Solution

  • Applicable Scenarios: Coastal cities, offshore islands, high-altitude plateaus, desert and frigid regions with harsh operating conditions including high salt fog, intense UV radiation, extreme high/low temperature and drastic temperature swings requiring minimum 10-year stable service life.
  • Configuration Package: KITOZER-C8018H high-end thickened anti-corrosion cabinet + AC160 AC power distribution + PS48200 high-frequency power supply + LFP48200 lithium iron phosphate battery + AC1500 variable frequency precision air conditioner + MON-H enhanced environment monitoring host + FM12 heptafluoropropane fire suppression device + full set of high-precision sensors + seismic connecting fittings
  • Solution Highlights: Thickened multi-layer anti-corrosion cabinet passed 1000-hour salt spray testing to guarantee 10-year corrosion-free operation in coastal salt fog zones; redundant dual cold source variable frequency air conditioners deliver precise constant temperature control from -40℃ to +60℃ under extreme ambient temperatures; wide-temperature lithium iron phosphate batteries maintain stable energy storage with extended cycle life under extreme hot/cold conditions; full-parameter intelligent monitoring with automatic fault linkage rapidly mitigates equipment risks under harsh environments; military-grade structural design provides superior anti-aging, UV, seismic and wind resistance for decades of stable outdoor deployment.

10.5 High-integration Edge Computing Node Solution

  • Applicable Scenarios: Urban edge zones, industrial parks, smart communities and front-end data center nodes deploying edge computing hardware featuring high power consumption, dense equipment layout, mass data processing and low-latency transmission requirements.
  • Configuration Package: KITOZER-C8018H high-end multi-expandable cabinet + AC160 AC power distribution + PS48200 high-frequency power supply + LFP48200 lithium iron phosphate battery + UPS3K online uninterrupted power supply + AC1500 variable frequency precision air conditioner + MON-H enhanced environment monitoring host + FM12 heptafluoropropane fire suppression device + full set of sensors + intelligent remote-controlled PDU
  • Solution Highlights: Multi-cabinet expandable layout supports co-deployment of multiple edge computing servers within a single cabinet; triple redundant power system (high-frequency power supply + UPS + lithium battery) eliminates computing node downtime risks; redundant precision air conditioning cooling delivers stable heat dissipation for high-power edge hardware; 5G low-latency data transmission satisfies real-time edge computing data processing demands; full intelligent remote management enables fully unattended edge node operation and simplified centralized O&M.

10.6 Photovoltaic/Wind Power Outdoor Energy Storage Base Station Solution

  • Applicable Scenarios: Solar photovoltaic power plants, wind farms, off-grid micro-grid stations and remote sites without stable municipal power requiring integrated energy storage and communication base station functions for self-power generation and residual energy storage.
  • Configuration Package: KITOZER-C8018 mid-end dual-cabinet
Shopping Cart