Table of Contents
Toggle1. System Overview
The KITOZER DC Distribution Unit (DCDU) serves as the core power distribution equipment for the -48VDC power supply system of 4G/5G base stations. Designed exclusively for communication power supplies, it undertakes centralized power distribution, overload/short-circuit protection, intelligent monitoring and secondary load shedding management for electric energy output from rectifier modules and battery packs. It delivers stable, safe and controllable DC power to BBUs, RRUs, AAUs, transmission equipment and monitoring terminals. Suitable for full-scenario deployment including macro base stations, micro base stations, edge computing nodes and outdoor cabinets, it features high reliability, high power density, easy maintenance and strong compatibility, acting as critical infrastructure to guarantee the continuous and stable operation of 5G networks.
KITOZER DCDU Physical Photo
2. System Composition
- Input Unit: Equipped with -48VDC main input terminals, battery parallel terminals, Class B+C lightning protection modules and EMI filter circuits, supporting redundant dual-input from rectifiers and storage batteries.
- Power Distribution Busbar Unit: High-conductivity tin-plated oxygen-free copper busbars with anti-oxidation treatment, insulating supports, main circuit circuit breakers/fuses to realize centralized energy convergence and primary protection.
- Output Distribution Unit: Multiple independent output branches, each fitted with DC circuit breakers/fuses, quick-connect terminals and branch status indicator lights, supporting hot-swap and fault isolation.
- Monitoring & Management Unit: Voltage/current sampling modules, microcontrollers, RS485 communication interfaces, LED/LCD display modules and dry contact alarm outputs. It monitors real-time system operating parameters and supports remote management.
- Protection Function Unit: Comprehensive protection including overvoltage/undervoltage, overcurrent/short-circuit, reverse polarity, secondary load shedding, insulation monitoring (high-end models) and lightning protection to fully safeguard the system and loads.
- Structural Unit: 19-inch standard rack-mount design (1U/2U height), cold-rolled steel cabinet with electrostatic spraying, front-and-rear ventilation cooling, front operation panel and protective grounding terminals.
3. System Classification
3.1 Classification by Power Rating
DCDU 3D Structural Drawing
- Low-Power Model (50A–100A): Model KITOZER-DCDU-50/100. Applicable to 5G micro base stations, indoor distribution systems and edge computing nodes, with 8–12 output channels and 5–10A per channel.
- Medium-Power Model (150A–200A): Model KITOZER-DCDU-150/200. Designed for 4G/5G macro base stations (1 BBU + 6 RRU configuration) and outdoor integrated cabinets, offering 10–16 output channels with 10–20A per channel.
- High-Power Model (250A–300A): Model KITOZER-DCDU-250/300. Used for 5G ultra-dense networking base stations, centralized power distribution in base station computer rooms and high-power multi-carrier AAU scenarios, with 16–24 output channels and 15–30A per channel.
3.2 Classification by Functional Features
- Basic Model: Pure power distribution and protection without monitoring functions, equipped with simple circuit breakers/fuses. Cost-effective for low-cost micro-station scenarios.
- Intelligent Model: Integrated voltage/current monitoring, RS485 communication, remote alarms and secondary load shedding control, compatible with Modbus-RTU protocol to meet intelligent operation and maintenance demands of base stations.
- Enhanced Model: Built on the intelligent model with additional insulation monitoring, branch electric energy metering, temperature monitoring and local LCD display, supporting cloud platform access for high-reliability core base stations.
3.3 Classification by Installation Method
DCDU Production Workshop
- Rack-Mount: Fits 19-inch standard cabinets with 1U/2U height, front operation and bidirectional maintenance, suitable for indoor computer rooms and integrated cabinets.
- Wall-Mount: Metal cabinet for wall installation with IP54 protection grade, ideal for outdoor base stations, tower-mounted stations and side mounting of outdoor cabinets.
- Embedded: Integrated inside integrated base station power cabinets to save space, matching customized power system designs.
4. System Schematic Diagram
plaintext
┌─────────────────┐ ┌─────────────────┐
│ Rectifier Output│ │ Battery Pack │
│ -48VDC │ │ -48VDC │
└────────┬────────┘ └────────┬────────┘
│ │
└────────────┬───────────┘
│
┌────────────▼────────────┐
│ Class B+C Lightning SPD │
└────────────┬────────────┘
│
┌────────────▼────────────┐
│ EMI Filter Circuit │
└────────────┬────────────┘
│
┌────────────▼────────────┐
│ Main Circuit Breaker QF0│
└────────────┬────────────┘
│
┌────────────▼────────────┐
│ DC Convergence Busbar │
└────────────┬────────────┘
│
┌─────────────────────┼─────────────────────┐
│ │ │ │ │
│ QF1(5A) │ QF2(10A) │ QF3(20A) │ QF4(30A)│ Output Branches (Expandable to 24 Channels)
│ │ │ │ │
└─────────┼────────────┼────────────┼─────────┘
│ │ │
┌─────────▼────────────▼────────────▼─────────┐
│ Load Equipment (BBU/RRU/AAU, etc.) │
└─────────────────────────────────────────────┘
│
┌────────────▼────────────┐
│ Voltage/Current Sampling│
└────────────┬────────────┘
│
┌────────────▼────────────┐
│ MCU Microcontroller │
└────────────┬────────────┘
│
┌─────────────────────┼─────────────────────┐
│ │ │ │ │
│ RS485 │ LCD Display│ Dry Contact│ Secondary│ Monitoring & Control Unit
│ Comm. │ Module │ Alarm Output│Load Shedding│
└─────────┴────────────┴────────────┴─────────┘
5. System Configuration List (Low/Medium/High Tiers)
On-site DCDU Installation & Commissioning
5.1 Low-Tier Configuration (Micro Base Station / Indoor Distribution)
表格
| No. | Product Name | Model Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DC Distribution Unit Mainframe | KITOZER-DCDU-50-B | -48VDC input, 50A total current; 8 output channels (4×5A + 4×10A); basic model without monitoring; 1U rack-mount; Class B input lightning protection; fuse protection per channel; terminal wire range 2.5–6mm²; dimensions 442×42×65mm; weight ≤1.5kg | 1 | Set | KITOZER | Basic power distribution, no communication |
| 2 | Input Cable | KITOZER-CAB-16-1M | 16mm² copper DC cable for -48VDC, 1m length, Class C flame retardant | 2 | Piece | KITOZER | Rectifier / battery input |
| 3 | Output Cable | KITOZER-CAB-6-2M | 6mm² copper DC cable for -48VDC, 2m length, Class C flame retardant | 8 | Piece | KITOZER | Load equipment connection |
| 4 | Mounting Bracket | KITOZER-BR-19-1U | 19-inch rack fixing bracket, cold-rolled steel, black electrostatic spraying | 1 | Set | KITOZER | Cabinet installation fixture |
5.2 Medium-Tier Configuration (Standard Macro Base Station)
表格
| No. | Product Name | Model Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DC Distribution Unit Mainframe | KITOZER-DCDU-200-S | -48VDC input, 200A total current; 12 output channels (6×10A + 6×20A); intelligent model with monitoring; 1U rack-mount; Class B+C input lightning protection; hot-swappable DC circuit breakers per channel; voltage/current monitoring; RS485 communication (Modbus-RTU); secondary load shedding control; terminal wire range 2.5–10mm²; dimensions 442×42×65mm; weight ≤1.8kg | 1 | Set | KITOZER | Intelligent power distribution, remote monitoring |
| 2 | Input Cable | KITOZER-CAB-50-1.5M | 50mm² copper DC cable for -48VDC, 1.5m length, Class C flame retardant, oil resistant | 2 | Piece | KITOZER | Rectifier / battery input |
| 3 | Output Cable | KITOZER-CAB-10-2.5M | 10mm² copper DC cable for -48VDC, 2.5m length, Class C flame retardant, oil resistant | 12 | Piece | KITOZER | Load equipment connection |
| 4 | Communication Cable | KITOZER-CAB-RS485-3M | Shielded twisted pair for RS485, 3m length, 120Ω impedance | 1 | Piece | KITOZER | Monitoring communication wiring |
| 5 | Mounting Bracket | KITOZER-BR-19-1U | 19-inch rack fixing bracket, cold-rolled steel, black electrostatic spraying | 1 | Set | KITOZER | Cabinet installation fixture |
| 6 | Surge Protector | KITOZER-SPD-DC-48 | -48VDC DC SPD, Class B+C, discharge current 40kA (8/20μs), response time ≤1ns | 1 | Set | KITOZER | Redundant input-side lightning protection |
5.3 High-Tier Configuration (High-Reliability Core Base Station)
表格
| No. | Product Name | Model Specs | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DC Distribution Unit Mainframe | KITOZER-DCDU-300-E | -48VDC input, 300A total current; 24 output channels (8×10A + 8×20A + 8×30A); enhanced full-function model; 2U rack-mount; Class B+C input lightning protection; hot-swappable DC circuit breakers per channel; voltage/current/temperature monitoring; branch energy metering; insulation monitoring; RS485 + Ethernet communication; local LCD display; secondary load shedding + battery protection; terminal wire range 2.5–16mm²; dimensions 442×88×65mm; weight ≤3.5kg | 1 | Set | KITOZER | Full-function intelligent power distribution, cloud access |
| 2 | Input Cable | KITOZER-CAB-70-2M | 70mm² copper DC cable for -48VDC, 2m length, Class A flame retardant, oil & high temperature resistant | 2 | Piece | KITOZER | Rectifier / battery input |
| 3 | Output Cable | KITOZER-CAB-16-3M | 16mm² copper DC cable for -48VDC, 3m length, Class A flame retardant, oil & high temperature resistant | 24 | Piece | KITOZER | Load equipment connection |
| 4 | Communication Cable | KITOZER-CAB-RS485-5M | Shielded twisted pair for RS485, 5m length, 120Ω impedance, Class A flame retardant | 1 | Piece | KITOZER | Monitoring communication wiring |
| 5 | Ethernet Cable | KITOZER-CAB-LAN-5M | Cat6 unshielded twisted pair, 5m length, supports 100Mbps transmission | 1 | Piece | KITOZER | Cloud platform access |
| 6 | Reinforced Mounting Bracket | KITOZER-BR-19-2U | 19-inch rack fixing bracket, cold-rolled steel, black electrostatic spraying, load-reinforced design | 1 | Set | KITOZER | Cabinet installation fixture |
| 7 | Premium Surge Protector | KITOZER-SPD-DC-48-PRO | -48VDC DC SPD, Class B+C, discharge current 60kA (8/20μs), response time ≤0.8ns, degradation alarm function | 1 | Set | KITOZER | Redundant high-performance input lightning protection |
| 8 | Insulation Monitoring Module | KITOZER-IM-48 | DC system insulation monitor, measures positive/negative pole-to-ground insulation resistance, alarm threshold 50kΩ, RS485 communication supported | 1 | Set | KITOZER | System insulation safety monitoring |
6. Full Product Technical Specifications
DCDU Internal Circuit Board
6.1 KITOZER-DCDU-50-B (Basic Low-Tier Model)
- Input Parameters: Rated voltage -48VDC (range -40VDC ~ -60VDC), rated total current 50A, 2 input paths (rectifier + battery).
- Output Parameters: 8 output channels (4×5A + 4×10A), max single-channel current 10A, total output current 50A, output voltage consistent with input (-48VDC).
- Protection Parameters: Class B input lightning protection (20kA), fuse protection per channel (breaking capacity 10kA), reverse polarity protection, overcurrent protection (1.2× rated current).
- Mechanical Parameters: 1U rack-mount, dimensions 442(W)×42(H)×65(D)mm, weight ≤1.5kg, cold-rolled steel cabinet with black electrostatic spraying, IP30 protection grade.
- Environmental Parameters: Operating temperature -20℃ ~ +55℃, storage temperature -40℃ ~ +70℃, relative humidity 10%–90% (non-condensing), altitude ≤2000m.
6.2 KITOZER-DCDU-200-S (Intelligent Medium-Tier Model)
- Input Parameters: Rated voltage -48VDC (range -40VDC ~ -60VDC), rated total current 200A, 2 input paths (rectifier + battery), Class B+C lightning protection (40kA).
- Output Parameters: 12 output channels (6×10A + 6×20A), max single-channel current 20A, total output current 200A, hot-swappable DC breakers per channel.
- Monitoring Parameters: Voltage monitoring (accuracy ±0.5%), total & branch current monitoring (accuracy ±1%), RS485 Modbus-RTU communication (9600bps baud rate), adjustable secondary load shedding voltage threshold, dry contact alarm outputs (normally open/normally closed).
- Protection Parameters: Class B+C input lightning protection, breaker protection per channel (breaking capacity 20kA), reverse polarity protection, overvoltage/undervoltage protection (-58VDC/-42VDC), overcurrent/short-circuit protection, battery over-discharge protection.
- Mechanical Parameters: 1U rack-mount, dimensions 442(W)×42(H)×65(D)mm, weight ≤1.8kg, cold-rolled steel cabinet with black electrostatic spraying, IP30 protection grade, front operation panel.
- Environmental Parameters: Operating temperature -20℃ ~ +55℃, storage temperature -40℃ ~ +70℃, relative humidity 10%–90% (non-condensing), altitude ≤2000m (1% power derating per 100m above 2000m).
6.3 KITOZER-DCDU-300-E (Enhanced High-Tier Model)
Outdoor Cabinet DCDU Construction Site
- Input Parameters: Rated voltage -48VDC (range -40VDC ~ -60VDC), rated total current 300A, 2 input paths (rectifier + battery), Class B+C lightning protection (60kA) + EMI filter circuit.
- Output Parameters: 24 output channels (8×10A + 8×20A + 8×30A), max single-channel current 30A, total output current 300A, hot-swappable DC breakers per channel, branch energy metering (accuracy ±0.5%).
- Monitoring Parameters: Voltage/current/temperature monitoring (accuracy ±0.5%/±1%/±1℃), insulation monitoring (0~1MΩ measuring range, 50kΩ alarm threshold), dual RS485 + Ethernet communication (Modbus-RTU/TCP), local LCD display for parameters/status/alerts, secondary load shedding + full battery protection, dry contact alarms, cloud platform access support.
- Protection Parameters: Class B+C lightning + EMI filtering on input side, breaker protection per channel (breaking capacity 30kA), reverse polarity, overvoltage/undervoltage (-58.5VDC/-41.5VDC), overcurrent/short-circuit, battery over-discharge/over-charge, insulation fault and overtemperature protection (85℃ power derating, 95℃ automatic shutdown).
- Mechanical Parameters: 2U rack-mount, dimensions 442(W)×88(H)×65(D)mm, weight ≤3.5kg, cold-rolled steel cabinet with black electrostatic spraying, IP30 protection grade, front-rear ventilation cooling, front operation panel, dedicated protective grounding terminal.
- Environmental Parameters: Operating temperature -25℃ ~ +60℃, storage temperature -40℃ ~ +75℃, relative humidity 5%–95% (non-condensing), altitude ≤3000m (1% power derating per 100m above 3000m), seismic performance compliant with GB/T 2423.56 standard.
6.4 Supporting Cable & Accessory Specifications
Central Monitoring Control Room
- KITOZER-CAB-16-1M: 16mm² oxygen-free copper DC cable for -48VDC, 1m length, PVC Class C flame retardant insulation, 1000VDC withstand voltage, operating temperature -20℃ ~ +70℃.
- KITOZER-CAB-50-1.5M: 50mm² oxygen-free copper DC cable for -48VDC, 1.5m length, PVC Class C flame retardant insulation, 1000VDC withstand voltage, oil resistance compliant with GB/T 16990 standard, operating temperature -20℃ ~ +70℃.
- KITOZER-SPD-DC-48: -48VDC Class B+C DC surge protector, 40kA (8/20μs) discharge current, response time ≤1ns, voltage protection level ≤60VDC, leakage current ≤10μA, operating temperature -40℃ ~ +80℃.
- KITOZER-IM-48: DC insulation monitoring module for -48VDC systems, 0~1MΩ measuring range, ±5% measurement accuracy, 50kΩ alarm threshold, RS485 Modbus-RTU communication, operating temperature -20℃ ~ +55℃.
7. Full Product Application Scope
7.1 Base Station Scenarios
- 5G Macro Base Stations: Supply -48VDC power to BBUs, RRUs, high-power AAUs, transmission equipment and station monitoring terminals. Compatible with 1BBU+6RRU or multi-carrier high-power AAU deployments to meet high-load and high-reliability power demands.
- 5G Micro/Pico Base Stations: For indoor building coverage, shopping malls, airports, stations and rural wide-coverage small cells. Powers compact RRUs, distributed antennas and edge computing nodes with compact size and flexible installation.
- 4G Base Station Retrofit: Expands power supply capacity for existing 4G power systems to add new 5G equipment branches. Fully compatible with legacy -48VDC rectifiers and battery packs, eliminating large-scale system renovation and cutting upgrade costs.
- Outdoor Integrated Base Stations: Optimized for outdoor cabinets, tower-mounted and field stations. Wide-temperature design, IP30 protection and robust lightning resistance adapt to harsh environments including extreme temperatures, high humidity and frequent lightning strikes.
7.2 Data Center & Computer Room Applications
Internal View of Outdoor Power Cabinet Equipped with DCDU
- Edge Computing Data Centers: Delivers -48VDC power to edge servers, switches and storage devices. DC power architecture reduces PUE and improves energy efficiency.
- Centralized Power Distribution for Base Station Computer Rooms: Acts as a power hub for small-to-medium base station computer rooms, centrally managing output from multiple rectifier and battery packs, simplifying wiring and boosting operation & maintenance efficiency.
- Communication Computer Room Supporting Equipment: Provides DC power to transmission and core network room communication hardware, monitoring devices and emergency lighting, with secondary load shedding to prioritize power for core equipment during outages.
7.3 Other Industrial Scenarios
- Industrial Automation Control: Supplies stable anti-interference -48VDC power to on-site PLCs, sensors, actuators and industrial switches.
- Rail Transit Communication: Powers communication base stations, signal equipment and monitoring devices along metro/high-speed rail lines. Wide-temperature, seismic and high-reliability design accommodates complex rail operating environments.
- New Energy Power Station Supporting Systems: Delivers DC power to communication monitoring systems and inverter control units of photovoltaic/wind farms, supporting both off-grid and grid-tied power generation systems.
8. Full Product Advantages
8.1 Core Functional Strengths
- High-Reliability Design: Adopts tin-plated high-conductivity copper busbars to reduce contact resistance and temperature rise; core components sourced from top international brands (Schneider/ABB circuit breakers, TI microcontrollers); redundant rectifier + battery dual-input design avoids full system power loss from single-path failure; Class B+C lightning protection effectively suppresses lightning surges.DCDU Row Installation in Power Room
- Intelligent Monitoring & Management: Intelligent/enhanced models integrate high-precision voltage/current/temperature sensing for real-time operational tracking; RS485/Ethernet Modbus-RTU/TCP connectivity integrates with station environmental monitoring systems and cloud platforms for remote parameter configuration and alarm push; enhanced models feature local LCD displays for convenient on-site maintenance; secondary load shedding cuts non-critical loads at preset voltage thresholds to extend battery backup runtime for core network equipment.
- Flexible Configuration & Expansion: Configurable output channels (8–24) with selectable single-channel ratings (5A/10A/20A/30A) matching diverse load power levels; hot-swappable breakers/fuses allow single-channel maintenance without disrupting other loads; standard 19-inch rack-mount form factor fits all standard cabinets; wall-mount and embedded variants support outdoor cabinets and integrated power system customization.
- Complete Multi-Layer Protection: Integrated overvoltage/undervoltage, overcurrent/short-circuit, reverse polarity, lightning, insulation monitoring (enhanced models), overtemperature and battery overcharge/over-discharge protection. Independent per-channel protection isolates faulty branches to prevent fault propagation; maximum 30kA breaking capacity safely interrupts short-circuit currents to protect wiring and end devices.
- Wide Environmental Adaptability: Enhanced models operate from -25℃ to +60℃ to withstand extreme hot desert and frigid alpine conditions; IP30 protection prevents dust and foreign object ingress; seismic performance meets GB/T 2423.56 for tower-mounted and vehicle-deployed vibration-prone applications; UL94 V0 flame-retardant materials enhance fire safety.
8.2 Customization & Service Advantages
- Deep Customization Capability: Customizable output channel quantity, single-channel current rating, communication interfaces, protection thresholds and cabinet dimensions. Optional integrated energy metering, insulation monitoring and temperature control modules; fully compatible with all mainstream rectifier and battery brands.
- OEM/ODM Contract Manufacturing: Supports private-label OEM production and custom appearance/function development based on client design specifications; high-volume mass production capacity guarantees short lead times for large-scale projects.
- Strict Confidentiality Protocols: Non-disclosure agreements for all custom designs, technical parameters and engineering drawings; internal classified data management prevents information leakage and protects client intellectual property rights.
- Adequate Stock Supply: Standard low/medium-tier models held in permanent inventory for immediate shipment; pre-stocked core components mitigate supply chain volatility; fast production scheduling for bulk orders to ensure on-time project delivery.
- Full-Spectrum Technical Support: Complete technical, installation and operation & maintenance manuals provided free of charge; complimentary technical consultation, solution design and on-site installation & commissioning guidance; regular professional training for client maintenance staff to build independent troubleshooting capabilities.
9. Bid Tender Technical Parameters (Marked with Asterisk *)
9.1 Universal Bid Tender Specifications
- * DC Input Voltage: -48VDC (operating range -40VDC ~ -60VDC), compliant with standard communication industry power supply voltage.
- * Total Input Current: ≥50A (low-tier), ≥200A (medium-tier), ≥300A (high-tier) to satisfy varying base station load power demands.
- * Output Channel Count: ≥8 channels (low-tier), ≥12 channels (medium-tier), ≥24 channels (high-tier) for flexible load expansion.
- * Lightning Protection Grade: Class B+C input SPD, discharge current ≥40kA (medium-tier) / ≥60kA (high-tier) to resist lightning surges.
- * Communication Interface: Intelligent/enhanced models standardize RS485 with Modbus-RTU protocol; high-tier models add Ethernet port for cloud platform integration.
- * Operating Temperature: -20℃ ~ +55℃ (low/medium-tier), -25℃ ~ +60℃ (high-tier) for harsh field deployment.
- * Protection Grade: IP30, dustproof and foreign-object intrusion resistant for stable equipment operation.
9.2 Low-Tier Model (KITOZER-DCDU-50-B) Bid Specifications
- * Output Channel Configuration: 4×5A + 4×10A, maximum single-channel current ≥10A.
- * Protection Type: Fuse per channel, breaking capacity ≥10kA.
- * Structural Dimensions: 1U rack-mount, width 442mm, height ≤42mm, depth ≤65mm.
9.3 Medium-Tier Model (KITOZER-DCDU-200-S) Bid Specifications
- * Output Channel Configuration: 6×10A + 6×20A, maximum single-channel current ≥20A.
- * Protection Type: Hot-swappable DC circuit breaker per channel, breaking capacity ≥20kA.
- * Monitoring Function: Total voltage, total current and branch current measurement; voltage accuracy ≤±0.5%, current accuracy ≤±1%.
- * Control Function: Adjustable secondary load shedding voltage threshold (-42VDC ~ -48VDC).
9.4 High-Tier Model (KITOZER-DCDU-300-E) Bid Specifications
- * Output Channel Configuration: 8×10A + 8×20A + 8×30A, maximum single-channel current ≥30A.
- * Protection Type: Hot-swappable DC circuit breaker per channel (breaking capacity ≥30kA); built-in insulation monitoring and overtemperature protection.
- * Monitoring Function: Voltage, current, temperature and branch energy metering (energy measurement accuracy ≤±0.5%); insulation monitoring range 0~1MΩ with alarm threshold ≤50kΩ.
- * Display Function: Integrated local LCD screen for real-time system parameter, operating status and fault alarm visualization.
10. Full Product System Solutions
10.1 DC Power Distribution Solution for 5G Macro Base Stations
- Solution Overview: Adopt KITOZER-DCDU-200-S (medium intelligent model) or KITOZER-DCDU-300-E (high enhanced model) for -48VDC power systems of 5G macro base stations, delivering stable, intelligent and reliable DC power to BBUs, RRUs, high-power AAUs, transmission hardware and station monitoring terminals, meeting high power consumption, high reliability and intelligent O&M requirements.
- System Architecture: -48VDC output from rectifier modules and parallel battery packs connects to the DCDU input side. After internal lightning protection, EMI filtering and busbar convergence, the DCDU distributes power through independent output branches to each load device. The DCDU links to the station environmental monitoring system via RS485 for remote measurement, alerting and control.
- Configuration Recommendations: Standard macro stations (1BBU+6RRU) select the medium-tier DCDU-200-S with 12 output channels (6×10A+6×20A), sufficient to power 1×BBU (10A), 6×RRUs (15A each), transmission equipment (10A) and monitoring terminal (5A). High-power AAU stations deploy the high-tier DCDU-300-E with 24 output channels to support multi-carrier high-consumption AAU loads.
- Solution Benefits: Intelligent remote monitoring cuts labor O&M costs; multi-layer protection minimizes equipment downtime caused by faults; secondary load shedding extends battery backup runtime to safeguard core network devices during blackouts; wide-temperature design ensures stable performance in harsh outdoor base station environments.
10.2 DC Power Distribution Solution for 5G Micro Base Stations
- Solution Overview: Deploy KITOZER-DCDU-50-B (low basic model) for -48VDC power systems of 5G micro/pico base stations, providing low-cost, high-reliability DC power to compact RRUs, distributed antennas and edge computing nodes with ultra-compact size and flexible installation.
- System Architecture: -48VDC output from integrated micro-station power supplies (rectifier + battery) feeds directly into the DCDU input. The unit distributes power via 8 independent protected output channels to all loads. No complex communication functions are included to reduce overall project costs.
- Configuration Recommendations: Single micro-stations (1 compact RRU + 1 distributed antenna + 1 edge computing node) use DCDU-50-B with 8 output channels (4×5A+4×10A). Wall-mounted installation is recommended for outdoor cabinet sides and building weak current boxes.
- Solution Benefits: Small footprint and lightweight construction enable rapid wall-mounted deployment and space savings; cost-effective basic protection meets micro-station budget requirements; integrated lightning and overcurrent protection withstands outdoor voltage fluctuations and lightning strikes; simple tool-free installation accelerates site rollout.
10.3 DC Power Distribution Solution for 4G-to-5G Base Station Retrofit
- Solution Overview: Utilize KITOZER-DCDU-200-S (medium intelligent model) to expand power capacity of legacy 4G base station -48VDC power systems, adding dedicated power branches for new 5G hardware. Fully compatible with existing rectifiers and battery packs to avoid large-scale renovation and reduce upgrade expenditure, enabling mixed 4G/5G equipment power supply.
- System Architecture: Existing 4G rectifier and battery pack -48VDC output connects to the new DCDU input side. DCDU output channels are split between legacy 4G equipment (reusing original wiring) and new 5G RRU hardware (new dedicated cabling). The DCDU connects to the original environmental monitoring system via RS485 for unified power system monitoring of both 4G and 5G loads.
- Configuration Recommendations: 4G macro station retrofits with 2–3 additional 5G RRUs deploy DCDU-200-S with 12 output channels: 4–6 channels reserved for original 4G hardware, 6–8 channels allocated to new 5G devices. The original power system capacity is fully reused without rectifier or battery replacement, requiring only new DCDU and output cable installation.
- Solution Benefits: Native compatibility with legacy 4G power infrastructure eliminates costly full-system replacement; capital expenditure reduced by reusing existing hardware with only additional distribution unit and cabling costs; unified intelligent monitoring streamlines cross-network O&M; modular expandable output channels support future incremental 5G equipment rollout.
11. Full Product Application Cases
11.1 5G Macro Base Station Construction Project for a Major Telecom Operator
- Project Profile: In 2025, a national telecom operator built 100 5G macro base stations across Guangzhou City, Guangdong Province, covering urban central districts, industrial parks and transportation hubs. Key requirements included high operational reliability, intelligent remote O&M and wide-temperature environmental tolerance, adopting standardized -48VDC DC power architecture.
- System Configuration: Each station deployed one KITOZER-DCDU-200-S medium intelligent DCDU with 12 output channels (6×10A+6×20A). Input side connected to a 48V/200A rectifier and two sets of 48V/500Ah battery packs. Output branches powered 1×BBU (10A), 6×RRUs (15A each), 1 transmission rack (10A) and 1 station monitoring terminal (5A). DCDU RS485 wired to the base station environmental monitoring system.
- Operational Outcomes: Zero unplanned power-related outages achieved, with power supply availability reaching 99.999%. Intelligent remote monitoring enabled real-time parameter tracking and automatic fault alert push, lifting O&M efficiency by 80%. Secondary load shedding extended battery backup runtime by 30% during mains failures, prioritizing core BBU and primary RRU power supply. Wide-temperature design delivered stable performance through Guangzhou’s hot summers (>40℃) and humid rainy seasons.
11.2 5G Micro Base Station Coverage Project for a Tower Operator
- Project Profile: In 2025, a national tower operator deployed 500 5G micro base stations across Shenzhen City, Guangdong Province, covering indoor commercial buildings, shopping malls and metro entrances. Core requirements: compact dimensions, flexible wall mounting, low total cost and robust reliability.
- System Configuration: Each micro-station fitted one KITOZER-DCDU-50-B basic low-tier DCDU with 8 output channels (4×5A+4×10A). Input wired to integrated 48V/50A rectifier + 48V/100Ah battery power supplies. Output branches supplied 1 compact RRU (10A), 1 distributed antenna (5A) and 1 edge computing gateway (10A). Wall-mounted installation on outdoor cabinet side panels and building weak current enclosures.
- Operational Outcomes: Miniature lightweight hardware simplified wall mounting, cutting site deployment time by 50%. Low-cost basic power protection reduced overall project capital expenditure by 30%. Integrated lightning and overcurrent protection mitigated outdoor lightning and grid voltage fluctuation risks, with equipment field failure rate below 0.5%. Hardware operated continuously without faults through Shenzhen’s year-round high temperature and humidity climate.
11.3 Provincial-Wide 4G-to-5G Base Station Capacity Expansion Retrofit Project
- Project Profile: In 2025, a provincial telecom operator upgraded 300 existing 4G macro base stations with additional 5G RRU hardware. Mandatory requirements: full compatibility with legacy power systems, minimal construction costs, rapid on-site retrofit and unified cross-network monitoring.
- System Configuration: Each retrofitted station installed one KITOZER-DCDU-200-S medium intelligent DCDU with 12 output channels. Input side directly interfaced with the original station’s 48V/200A rectifier and battery packs without power system replacement. 4 output channels allocated to legacy 4G BBUs, transmission racks and monitoring gear; the remaining 8 channels dedicated to newly added 5G RRUs. DCDU RS485 integrated into the existing environmental monitoring platform for unified 4G/5G power visibility.
- Operational Outcomes: Native compatibility eliminated rectifier and battery replacement, slashing retrofit construction timelines by 60% and total project costs by 40%. Centralized intelligent monitoring unified power asset management for both 4G and 5G networks, boosting O&M efficiency by 70%. Independent per-channel protection isolated faults on new 5G hardware without disrupting legacy 4G network operation, improving overall network stability. Modular expandable output branches support incremental future 5G capacity upgrades.
12. Product Common Faults, Maintenance & Servicing Guidelines
12.1 Common Faults & Troubleshooting Procedures
- Symptom: Normal input voltage, zero output voltage
- Root Causes: Tripped main circuit breaker/blown main fuse; reversed input polarity; damaged lightning surge protector; loose internal busbar connections.
- Resolution: Inspect and replace failed main breakers/fuses; correct reversed positive/negative wiring; test and replace defective SPD units; fully cut power then tighten loose internal busbar terminals.
- Symptom: Single channel no output, all other branches functional
- Root Causes: Tripped channel breaker/blown channel fuse; loose output wiring; short-circuited or overloaded end load.
- Resolution: Replace failed channel breakers/fuses; retighten output terminal wiring; disconnect the load to diagnose short-circuit/overload conditions, restore power after fault elimination.
- Symptom: Abnormally deviant voltage/current monitoring readings
- Root Causes: Damaged sampling modules; loose sampling wiring; incorrect monitoring parameter calibration settings.
- Resolution: Replace faulty sampling modules; retighten sampling wiring terminals; enter monitoring configuration interface to recalibrate voltage and current measurement offsets.
- Symptom: Communication failure, remote monitoring inaccessible
- Root Causes: Loose RS485/Ethernet wiring; mismatched communication parameters; damaged communication interface module.
- Resolution: Secure loose communication cable terminals; verify and reconfigure matching communication address, baud rate and protocol; replace defective communication modules and retest data transmission.
- Symptom: SPD fault alarm indicator illuminated
- Root Causes: SPD damaged by lightning surges; end-of-life degraded SPD components.
- Resolution: Replace failed/aged surge protectors; inspect and optimize grounding system to ensure grounding resistance ≤4Ω for enhanced lightning protection performance.
12.2 Routine Maintenance Schedule
- Daily Inspection: Check power, alarm and communication status indicators for fault alerts; review voltage/current display readings (intelligent/enhanced models) to confirm normal operating parameters; inspect cabinet exterior for overheating, abnormal odors or mechanical noise.
- Weekly Maintenance: Retighten all input/output wiring terminals to prevent thermal buildup from loose contacts; wipe cabinet exterior dust to preserve ventilation; verify SPD functional status without fault alarms; test remote communication connectivity for uninterrupted monitoring access.
- Monthly Maintenance: Inspect breaker/fuse condition and test trip functionality; recalibrate voltage/current measurement accuracy; verify reliable grounding connections; back up all monitoring configuration parameters to prevent data loss.
- Quarterly Maintenance: Fully cut power then open cabinet housing to clear accumulated internal dust; inspect busbars and terminals for oxidation/corrosion; check capacitors, relays and active components for aging degradation; test system insulation resistance for compliance with safety standards.
- Annual Overhaul: Full functional performance testing of all internal modules, replace aging degraded components; complete SPD lightning protection performance validation; inspect cooling fan operation (if equipped) and replace failed units; full load testing to verify rated power carrying capacity.
12.3 Maintenance Safety Precautions
- Safe Operating Protocols: Disconnect both rectifier and battery input power before all maintenance work, post “Do Not Close Breaker” warning signage. Wear insulated gloves and safety goggles during service to avoid electric shock hazards; strictly prohibit live disassembly of internal modules to prevent short-circuit arcing.
- Environmental Requirements: Conduct maintenance work in dry, clean surroundings to avoid dust/moisture intrusion into the unit; restrict working ambient temperature to 0℃ ~ +40℃, avoid high-temperature service environments.
- Spare Parts Management: Maintain on-site stock of consumable critical spares (circuit breakers, fuses, SPDs, communication modules) for rapid fault repair; store spare components in dry ventilated storage and conduct periodic condition audits.
- Maintenance Record Archiving: Establish dedicated equipment maintenance logs documenting all inspections, service activities and fault resolution records. Regularly analyze maintenance trend data to predict potential pre-failure risks and develop proactive preventive maintenance schedules.
13. Factory Strength & After-Sales Service
13.1 Manufacturing Plant Strength
- Corporate Qualifications: KITOZER brand belongs to Guangzhou Lai’an Intelligent System Development Co., Ltd., a national high-tech enterprise and specialized sophisticated innovative SME. Certified under ISO9001 Quality Management, ISO14001 Environmental Management and ISO45001 Occupational Health & Safety Management systems. All products comply with CE, UL and RoHS international standards.
- Production Scale: Modern 10,000㎡ manufacturing facility equipped with fully automatic SMT placement machines, wave soldering equipment, full-load aging test racks and precision testing instruments. Annual DCDU production capacity reaches 100,000 units to fulfill large-scale mass project delivery requirements.
- R&D Capabilities: In-house dedicated R&D team of over 30 engineers including 10 senior specialists focused on communication power and DC power distribution hardware. Independent proprietary design and customization capabilities; annual R&D investment equals 15% of corporate revenue with over 20 granted invention and utility model patents, leading industry technical performance.
- Quality Control System: End-to-end full lifecycle quality management covering raw material procurement, production assembly, finished goods testing and factory release. Core components sourced from premium international brands (Schneider, ABB, TI, Philips) to guarantee consistent hardware quality. 100% full-load 48-hour aging testing, 100% functional verification and 100% insulation withstanding voltage testing performed on all finished units; zero non-conforming product factory release policy delivers 99.98% product pass rate.
13.2 After-Sales Service Commitments
- Warranty Policy: All KITOZER DC distribution units carry a 3-year free warranty from factory acceptance date. Free repair and component replacement for non-human-induced failures within warranty period; lifetime paid maintenance post-warranty, only charging component material costs with zero labor service fees.
- Technical Support Response Mechanism: 7×24-hour hotline technical support, 1-hour initial response to all customer inquiries; full technical resolution plan delivered within 4 hours. On-site engineer dispatch within 24 hours for critical faults in domestic first-tier cities, extended to 48 hours for remote rural regions. Remote telephone, video and desktop sharing support for real-time fault diagnosis and troubleshooting guidance.
- Installation & Commissioning Support: Complimentary provision of full installation and commissioning operation manuals; free on-site engineer dispatch to guide field wiring, assembly and functional testing for project deployment. Complimentary hands-on technical training for client O&M personnel covering equipment operation, routine maintenance and fault troubleshooting to build independent in-house service capacity.
- Customization Support: Free dedicated power distribution solution design based on client project load specifications, environmental operating conditions and functional requirements; full hardware customization development for unique channel counts, interfaces, protection logic and cabinet dimensions. Complete OEM/ODM private-label manufacturing services available.
- Spare Parts Supply Guarantee: National distributed spare parts inventory network stocking core consumables (breakers, fuses, SPDs, communication modules) in major cities for expedited emergency delivery. Standby unit provision for large bulk projects to maintain uninterrupted site operation during hardware repairs. Standard spare parts ship within 3 working days; custom manufactured spares delivered within 7 working days.
14. Conclusion
As the core power distribution hardware for 4G/5G base station -48VDC power supply systems, KITOZER DC Distribution Units deliver stable, secure and controllable DC power to BBUs, RRUs, AAUs, transmission equipment and monitoring terminals through high-reliability engineering, intelligent monitoring, flexible expandable configuration, comprehensive multi-layer protection and wide environmental adaptability.
The full product lineup spans low, medium and high power tiers with basic, intelligent and enhanced functional variants, fully compatible with 5G macro stations, micro stations, 4G retrofit stations and outdoor integrated cabinet deployments. Additional cross-industry applicability extends to edge computing data centers, industrial automation, rail transit communication and new energy power station auxiliary systems, creating an extensive multi-sector application ecosystem.
Supported by robust independent R&D, advanced automated production equipment, stringent full-process quality control and comprehensive end-to-end after-sales service, KITOZER delivers one-stop full-lifecycle solutions including custom power distribution design, product OEM manufacturing, on-site installation commissioning and long-term maintenance. The product portfolio enables telecom operators and industry clients to accelerate 5G network rollout, reduce total construction and O&M expenditure, and enhance end-to-end network operational stability.
Moving forward, KITOZER will continue to focus on communication power and DC power distribution product innovation, increasing R&D investment to optimize hardware performance, elevate intelligent monitoring functionality and expand cross-industry application scenarios. The brand aims to supply higher-performance, more reliable and smarter DC power distribution solutions to advance nationwide 5G infrastructure construction and digital economy development, establishing long-term win-win partnerships with all industry clients to jointly build the new 5G digital era.
15. Search Keywords, SEO & Tags
15.1 Search Keywords
- Core Keywords: 4G/5G Base Station DC Distribution Unit, KITOZER DC Power Distribution Unit, -48VDC DC Distribution Unit, Base Station DCDU, 5G Base Station DC Power Distribution Solution
- Long-Tail Keywords: 5G Macro Base Station DC Distribution Unit, 5G Micro Base Station DC Power Distribution Unit, 4G Base Station Retrofit 5G DC Power Distribution, Outdoor Base Station DC Distribution Unit, Intelligent DC Distribution Unit, DC Distribution Unit Manufacturer, KITOZER DCDU-200-S, KITOZER DCDU-300-E