Table of Contents
Toggle1. System Introduction
The KITOZER Indoor Integrated Cabinet Anti-Theft Access Control System is a high-security, highly reliable intelligent physical protection and authority management system specially developed for various indoor intelligent cabinets, server cabinets, network cabinets, industrial control cabinets, integrated cabinets and other equipment. It is designed and developed in strict compliance with national and industrial standards including GB 50396-2007 Code for Design of Access Control System Engineering, GB/T 37078-2018 Technical Requirements for Access Control Systems, GA 374-2019 Electronic Locks for Anti-Theft Purposes and T/ZZB 0819—2025 Electric Control Locks for Cabinets.
Adopting the core design philosophy of “precise authority control, full traceability of behaviors, active risk early warning and full-scenario intelligent linkage”, the system addresses the industry pain points of traditional mechanical cabinet locks such as easily duplicated keys, difficult authority management, no early warning against intrusion and untraceable incidents. It builds a full closed-loop safety protection system covering identity authentication, authority verification, lock execution, status monitoring, abnormal alarms, data storage and platform management. The system realizes intelligent, refined and visualized full-lifecycle control over cabinet doors, serving as a core physical safety barrier for core equipment and data assets in data centers, computer rooms, industrial control sites, communication base stations, financial outlets, government and enterprise offices and other scenarios.
The system can seamlessly connect to the full range of KITOZER indoor integrated cabinets, environmental monitoring systems and computer room security systems. It supports both local deployment and cloud management modes with strong compatibility and scalability, enabling customized development per user requirements. OEM/ODM processing services are also available to meet cabinet protection demands of different industries, scales and security levels.
2. System Composition
The KITOZER cabinet anti-theft access control system adopts a layered, modular architecture, divided into five core layers: Perception Layer, Control Layer, Execution Layer, Management Layer and Linkage Layer. Modules of each layer cooperate with each other while supporting independent expansion to ensure stable, reliable operation and flexible deployment.
2.1 Perception Layer (Identity Authentication & Status Sensing Unit)
As the “nerve endings” of the system, the Perception Layer completes user identity information collection, real-time cabinet status sensing and abnormal behavior identification, forming the first line of defense for system security protection. Its core equipment includes:
- Identity authentication devices: IC card readers, CPU national secret card readers, fingerprint identifiers, finger vein recognition terminals, face recognition all-in-one machines, password keypads, Bluetooth/NFC identification modules, electronic key readers, etc.
- Status sensing devices: door magnetic switches, lock bolt status sensors, vibration sensors, tilt sensors, anti-disassembly sensors, false lock detection sensors, door open timeout monitoring modules, etc.
- Auxiliary environmental sensing devices (optional for linkage protection): cabinet temperature & humidity sensors, smoke detectors, water immersion sensors, etc.
2.2 Control Layer (Core Decision & Data Processing Unit)
Acting as the “brain” of the system, the Control Layer receives information uploaded by the Perception Layer and completes core logical operations including identity verification, authority judgment, instruction distribution, data storage, alarm handling and communication interaction, serving as the core hub for stable system operation. Its core equipment includes:
- Cabinet access controllers: single-door/dual-door/four-door access controllers, micro controllers dedicated to integrated cabinets, national secret security controllers, DIN rail-mounted access control modules.
- Data storage units: local storage modules, industrial-grade SD cards, solid-state drives, supporting offline local storage of event records.
- Communication units: TCP/IP Ethernet modules, RS485 bus modules, 4G/5G wireless modules, WiFi modules, Bluetooth communication modules, LORA IoT modules.
- Power management units: dedicated regulated power supplies for access control, UPS backup power modules, lithium battery backup units, lightning and surge protection modules, over-current & over-voltage protection modules.
2.3 Execution Layer (Physical Locking & Action Execution Unit)
The Execution Layer is the “hands” of the system. It receives instructions issued by the Control Layer to complete physical actions including lock opening/closing and alarm signal output, forming the core execution mechanism for physical cabinet protection. Its core equipment includes:
- Core lock devices: dedicated cabinet electromagnetic locks, electric bolt locks, intelligent electric locks, passive electronic locks, integrated handle electric control locks, mechatronic locks, anti-pry & explosion-proof cabinet locks.
- Alarm execution devices: audible & visual alarms, stroboscopic warning lights, voice deterrent broadcasters, alarm output relay modules.
- Auxiliary execution devices: cabinet interior lighting linkage modules, emergency unlocking devices, fire linkage relays, exit buttons, emergency break-glass buttons.
2.4 Management Layer (Platform Management & Operation & Maintenance Control Unit)
Serving as the “central command center” of the system, the Management Layer handles full-system equipment management, authority management, log management, alarm management, report management and remote operation & maintenance, providing users with a visualized one-stop management interface. Its core components include:
- Local management terminals: cabinet access control management software, industrial control machine management terminals, touch screen local management hosts.
- Cloud management platforms: B/S architecture Web management platform, mobile APP/mini-program management terminals.
- Supporting management tools: card issuers, authority configuration tools, equipment debugging tools, data backup & recovery modules.
2.5 Linkage Layer (System Integration & Collaborative Protection Unit)
The Linkage Layer acts as the “expansion interface” of the system, realizing interconnection and collaborative linkage between the access control system and third-party systems to build an all-round cabinet safety protection system. Connectable systems include:
- KITOZER environmental monitoring system and computer room environmental monitoring system;
- Video surveillance system, intrusion alarm system, fire emergency system;
- Computer room DCIM management platform, enterprise human resource management system, operation & maintenance management platform;
- National secret security authentication system, equal compliance audit system.
3. System Classification
The KITOZER cabinet anti-theft access control system classifies full-series products based on five dimensions: application scenario, security protection level, authentication mode, communication mode and deployment form, covering all-scenario application requirements. Detailed classification is as follows:
3.1 Classification by Security Protection Level
3.1.1 Basic Protection System (Class C)
Applicable to general office scenarios, non-core business cabinets and low-security-demand scenarios. It adopts single-factor identity authentication, mainly realizing authority control over cabinet doors, storage of open/close records and basic abnormal alarm functions. It features high cost performance, simple deployment and convenient maintenance.
3.1.2 Intermediate Protection System (Class B)
Applicable to small and medium enterprise computer rooms, industrial control site cabinets, branch computer rooms and other medium-security-demand scenarios. It adopts two-factor identity authentication, integrating anti-pry detection, door open timeout alarm, false lock alarm, offline operation and remote management functions. It supports basic linkage with environmental monitoring systems, balancing security and usability.
3.1.3 High-Grade Protection System (Class A)
Applicable to core data center computer rooms, financial industry cabinets, government confidential computer rooms, operator core computer rooms and other high-security-demand scenarios. Designed in strict compliance with Class 2.0 Equal Protection and confidential information system protection standards, it adopts three or more multi-factor authentication modes, with functions including national secret encrypted transmission, duress alarm, anti-passback, anti-tailgating, full-link audit and fire linkage, as well as deep integration with multiple systems. It supports dual-machine hot standby, redundant power supply and offline emergency unlocking, meeting high compliance, high reliability and high security protection requirements.
3.2 Classification by Identity Authentication Mode
- Card-swiping access control system: Supports ID cards, IC cards, CPU national secret cards and NFC card authentication, complying with the international ISO 14443 standard. It is divided into single card-swiping and card-swiping + password modes, the most widely used basic system.
- Biometric access control system: Integrates fingerprint, finger vein, face, palm vein and other biometric technologies with living body detection to eliminate risks of card duplication and password leakage. The false acceptance rate ≤0.001% and false rejection rate ≤0.1%, making it the preferred solution for high-security scenarios.
- Passive access control system: Adopts passive electronic locks + electronic key authentication. The lock body requires no external power supply; the electronic key supplies power and completes identity verification. Suitable for scattered deployment scenarios without wiring conditions, it supports offline authorization and full traceability of operation records.
- Wireless Bluetooth access control system: Adopts Bluetooth/NFC communication technology, supporting mobile APP/mini-program scan-to-unlock, remote authorized unlocking and temporary password unlocking. No wiring required, ideal for old cabinet renovation with flexible and convenient deployment.
- Multi-factor integrated access control system: Freely combines card swiping, password, biometrics, Bluetooth, electronic keys and other authentication methods. Authentication combination strategies can be configured according to cabinet security levels to realize graded protection.
3.3 Classification by Communication Transmission Mode
- Wired TCP/IP access control system: Adopts Ethernet wired communication with fast transmission speed, high stability and encrypted data transmission. It supports cross-network segment and cross-region networking, serving as the mainstream commercial solution for centrally deployed cabinet clusters in computer rooms.
- RS485 bus access control system: Adopts industrial-grade RS485 bus communication with strong anti-interference capability, simple wiring and long transmission distance, suitable for small and medium computer rooms and multi-cabinet series deployment scenarios.
- Wireless IoT access control system: Supports 4G/5G, WiFi, LORA, NB-IoT and other wireless communication modes without complex wiring. Suitable for scattered deployment, remote sites and old computer room renovation scenarios, it supports remote cloud management.
- Offline access control system: Supports local authority storage and offline authentication & unlocking. It can operate normally without network coverage and automatically synchronizes data after network recovery, applicable to no-network coverage and high-confidentiality scenarios.
3.4 Classification by Lock Execution Mechanism
- Electromagnetic lock access control system: Uses dedicated cabinet magnetic locks with optional power-off lock/power-off unlock modes, strong suction force, no mechanical wear and long service life, easy to install for most indoor cabinet scenarios.
- Electric bolt lock access control system: Adopts miniature electric bolt locks with small size, strong concealment and high locking precision, suitable for special installation scenarios such as glass door cabinets, thin cabinets and embedded cabinet doors.
- Mechatronic integrated handle lock system: Integrates dual electric control and mechanical unlocking modes with an integrated handle design, matching standard cabinet mounting holes without cabinet modification. Built-in status detection and anti-pry alarm functions, it is the standard configuration for indoor integrated cabinets.
- Intelligent lock access control system: Driven by motors with lock bolt status feedback, anti-pry and false lock detection functions. It features strong locking force and high resistance to forced opening, suitable for high-security and high-protection cabinet scenarios.
- Passive electronic lock system: Passive lock body design requiring no external power supply or wiring, with emergency mechanical unlocking. Suitable for scattered deployment scenarios without power supply conditions.
3.5 Classification by Deployment Form
- Single cabinet independent access control system: One set of system corresponds to one single cabinet with independent power supply, control and management, no networking required. Suitable for scattered single cabinet deployment scenarios with simple installation and maintenance.
- Centralized cabinet cluster access control system: Adopts a “main controller + sub-controller” architecture; one main controller can manage multiple cabinets with centralized power supply and unified management of authorities, applicable to cabinet clusters and cold aisle cabinet groups in computer rooms, reducing deployment costs and improving management efficiency.
- Distributed cloud access control system: Adopts cloud platform architecture, supporting unified management of multi-cabinet across regions, multiple computer rooms and multiple sites, remote authority configuration, real-time alarm push and centralized data storage, suitable for chain institutions, multi-branch organizations and nationwide operation & maintenance management scenarios.
- Integrated embedded access control system: Highly integrates access controllers, card readers, lock bodies and power modules, directly embedded inside cabinet doors with neat appearance, strong concealment and anti-disassembly & anti-damage performance. Matches the full range of KITOZER indoor integrated cabinets, the preferred solution for factory pre-installation.
4. System Schematic Principles
4.1 Overall Working Principle Block Diagram of the System
The KITOZER cabinet anti-theft access control system adopts a “five-layer architecture closed-loop operation” overall working mode, with core workflow as follows:
- Identity Collection: Users submit identity credentials (card number, fingerprint, face, password, etc.) through Perception Layer devices such as card readers and biometric recognition terminals. After information collection and preprocessing, the equipment uploads data to the access controller via an encrypted communication link.
- Authority Verification: After receiving identity information, the access controller compares it with the locally stored authority database for verification, while checking parameters such as current time, accessible time period and authorized cabinet scope to judge whether the user has the unlocking authority for the target cabinet.
- Instruction Execution: If authority verification passes, the controller sends an unlocking instruction to the corresponding cabinet electric lock. The lock body executes the unlocking action and links to turn on the cabinet interior lighting, recording full information of this unlocking event including personnel, time, cabinet number and unlocking mode. If verification fails, the controller rejects the unlocking instruction, records the unauthorized attempt event, triggers local audible & visual alarms and uploads alarm information to the management platform.
- Status Monitoring: The system monitors cabinet door and lock status in real time through door magnetic sensors, lock bolt sensors, vibration sensors and other equipment. Once abnormal conditions such as forced prying, unauthorized door opening, door open timeout and incomplete locking are detected, audible & visual alarms are triggered immediately, alarm information is pushed to managers synchronously and the video surveillance system is linked to capture images and record videos.
- Data Management: All unlocking records, alarm events and equipment status information are synchronously stored in both the local controller and management platform database, supporting log query, report export and audit traceability. It can also connect to third-party operation & maintenance and audit systems to realize data interconnection.
- Emergency & Linkage Functions: Supports fire linkage: automatic unlocking of cabinet locks in corresponding areas upon receiving fire alarm signals to guarantee emergency disposal. It also supports emergency break-glass buttons and mechanical emergency key unlocking to cope with extreme conditions such as power outages and equipment failures. Linkage with environmental monitoring, video surveillance and intrusion alarm systems builds an all-round protection system.
4.2 System Electrical Wiring Schematic Diagram
4.2.1 Core Wiring Principle of Single-Door Cabinet Access Control System
- Power Circuit: The dedicated access control power supply inputs AC220V mains power and outputs stable DC12V direct current to supply power for access controllers, card readers, electric locks and audible & visual alarms. Backup power modules are connected in parallel to the power output terminal to automatically switch power supply in case of mains power failure, ensuring continuous system operation.
- Control Circuit: The Wiegand/RS485 communication interface of the access controller is connected to the corresponding communication ports of card readers and identification terminals for identity data transmission. The relay output port of the controller is connected to the control input terminal of the electric lock to control lock opening/closing via relay on-off. The switch input port of the controller is connected to the output terminals of door magnetic sensors, anti-disassembly sensors, exit buttons and emergency break-glass buttons to collect status signals in real time.
- Alarm Circuit: The alarm output port of the controller is connected to the control terminals of audible & visual alarms and voice broadcasters. Alarm signals are output to trigger audible & visual warnings upon abnormal events.
- Linkage Circuit: The linkage input/output port of the controller connects to the corresponding interfaces of fire, environmental monitoring and video surveillance systems to realize signal interaction and linkage actions.
4.2.2 Wiring Principle of Centralized Multi-Cabinet Access Control System
RS485 bus/TCP/IP network is adopted to network multiple cabinet sub-controllers with the main controller. The main controller uniformly connects to the management platform and linkage systems. Each sub-controller manages one or two sets of cabinet access control equipment independently to complete identity verification, lock control and status collection. The main controller is responsible for unified authority management, centralized data upload and linkage instruction distribution to realize centralized control of multiple cabinets. Meanwhile, failure of a single sub-controller will not affect normal operation of other cabinets, ensuring system redundancy.
4.3 System Data Transmission & Encryption Schematic Diagram
The system adopts full-link encrypted data transmission. Identity credential information, control instructions and alarm data are all encrypted with the national secret SM4 algorithm; cloud communication adopts HTTPS/TLS1.3 security protocols to prevent data theft, tampering and forgery. Encrypted Wiegand/OSDP protocol communication is used between card readers and controllers to block interception attacks in the middle. Two-way identity authentication is adopted between controllers and the management platform to ensure legal identities of both communication parties. Meanwhile, authority data supports local encrypted storage without loss upon power failure, and automatic breakpoint resume transmission after network recovery to guarantee data integrity and security.
5. System Configuration List (KITOZER Brand, Three Grades: Basic, Intermediate, High-Grade, No Price Included)
5.1 General Instructions for Configuration List
- All products in the list adopt the unified KITOZER brand, covering three protection grades: Basic, Intermediate and High-Grade to meet demands of different scenarios.
- Specifications, technical parameters and quantity configurations in the list are calculated based on 10 standard cabinets in a single computer room; quantities can be scaled proportionally according to actual cabinet numbers.
- Each entry includes eight core columns: Serial Number, Product Name, Model Specification, Technical Parameters, Quantity, Unit, Brand and Remarks with complete and detailed information.
- All products support customized development and OEM/ODM processing; specifications and parameters can be adjusted according to user cabinet sizes, installation environments and security requirements.
5.2 Basic Protection System Configuration List (Class C, Single-Factor Authentication, Basic Protection)
| Serial No. | Product Name | Model Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Single-Door Cabinet Access Main Controller | KTZ-MJ-C-01 | Industrial-grade 32-bit main control chip, DC12V power supply, supports TCP/IP communication, single-door control, Wiegand 26/34 protocol, storage for 10,000 user cards and 100,000 event records, operating temperature -10℃~60℃, humidity 0~95% non-condensing, over-current, over-voltage and reverse connection protection | 10 | Set | KITOZER | 1 set per cabinet for local control, supports centralized networking |
| 2 | IC Card Reader | KTZ-DK-C-01 | Supports 13.56MHz IC cards complying with ISO 14443 standard, card reading distance 3~8cm, Wiegand 26/34 output, DC12V power supply, operating temperature -10℃~60℃, IP30 protection grade, ABS flame-retardant housing | 10 | Set | KITOZER | 1 set per cabinet door, embedded/wall-mounted optional |
| 3 | Dedicated Cabinet Electromagnetic Lock | KTZ-SU-C-01 | DC12V power supply, static pull force ≥180kg, power-off lock type with lock status feedback signal, residual suction ≥10%, no mechanical wear, service life ≥1 million times, operating temperature -20℃~60℃, 304 stainless steel bolt, IP30 protection grade | 10 | Set | KITOZER | 1 set per cabinet door, matches standard cabinet mounting holes |
| 4 | Door Magnetic Switch | KTZ-MC-C-01 | Normally closed type, compatible with DC12V, real-time detection of door open/close status, operating distance ≥15mm, ABS flame-retardant housing, service life ≥1 million times, operating temperature -20℃~70℃ | 10 | Set | KITOZER | 1 set per cabinet to monitor real-time door switch status |
| 5 | Exit Button | KTZ-AN-C-01 | Normally open self-reset type, ABS flame-retardant material, standard 86-type size, press service life ≥500,000 times, compatible with DC12V control circuit | 10 | Pc | KITOZER | 1 pc installed inside each cabinet for authorized personnel internal exit unlocking |
| 6 | Dedicated Access Control Power Supply | KTZ-DY-C-01 | AC220V input, DC12V/3A output, over-current, over-voltage and short-circuit protection, compatible with backup battery access, operating temperature -10℃~60℃, efficiency ≥85% | 10 | Set | KITOZER | 1 set per cabinet for independent power supply guarantee |
| 7 | Audible & Visual Alarm | KTZ-BJ-C-01 | DC12V power supply, alarm volume ≥100dB, red LED stroboscopic warning, open/closed trigger optional, operating temperature -20℃~60℃, ABS flame-retardant housing | 1 | Set | KITOZER | 1 set centrally deployed in the computer room to trigger alarms upon abnormal events |
| 8 | Access Control Management Software | KTZ-RJ-C-01 | C/S architecture, compatible with Windows system, supports user management, authority configuration, record query and basic alarm functions, connects up to 100 access control devices, logs exportable in Excel format | 1 | Set | KITOZER | 1 set deployed on computer room management terminal, permanent authorization with free upgrades |
| 9 | IC Card Issuer | KTZ-FK-C-01 | USB plug-and-play, supports read-write of 13.56MHz IC cards, compatible with access control management software, DC5V power supply, card reading distance 3~5cm, operating temperature 0℃~50℃ | 1 | Set | KITOZER | 1 set deployed at management center for card issuing, cancellation and authority configuration |
| 10 | Standard Blank IC Card | KTZ-KA-C-01 | 13.56MHz M1 chip, complies with ISO 14443 standard, rewritable ≥100,000 times, data storage ≥10 years, blank printable with customized printing available | 50 | Pc | KITOZER | Configured per user quantity including spare cards |
| 11 | Cabinet Installation Auxiliary Material Package | KTZ-FC-C-01 | Includes RVV2×1.0 power cable, RVVP4×0.75 signal cable, wiring terminals, expansion bolts, cable ties, insulating tape, wire conduits and full set of installation auxiliary materials suitable for wiring of 10 cabinets | 1 | Set | KITOZER | Specifications and quantities of auxiliary materials adjustable per actual installation scenario |
5.3 Intermediate Protection System Configuration List (Class B, Two-Factor Authentication, Intermediate Protection)
| Serial No. | Product Name | Model Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Four-Door Cabinet Access Main Controller | KTZ-MJ-B-01 | Industrial-grade ARM Cortex-M4 main control chip, DC12V wide voltage power supply, dual TCP/IP+RS485 communication, max 4-door control, Wiegand/OSDP protocol, storage for 50,000 user cards/fingerprint templates and 500,000 event records, operating temperature -20℃~70℃, humidity 0~95% non-condensing, lightning surge, over-current, over-voltage and anti-disassembly protection, supports offline operation | 3 | Set | KITOZER | 1 main controller manages 4 cabinets; 3 sets configured for 10 cabinets with redundant backup |
| 2 | Fingerprint + IC Card Two-Factor Card Reader | KTZ-DK-B-01 | Semiconductor fingerprint sensor + 13.56MHz IC card dual-in-one, supports fingerprint + card swiping dual authentication, fingerprint recognition time ≤0.5s, false rejection rate ≤0.1%, false acceptance rate ≤0.001%, card reading distance 3~10cm, Wiegand/RS485 output, DC12V power supply, operating temperature -20℃~60℃, IP40 protection grade, metal flame-retardant housing with anti-disassembly alarm | 10 | Set | KITOZER | 1 set embedded on each cabinet door with anti-pry design |
| 3 | Dedicated Cabinet Mechatronic Integrated Handle Lock | KTZ-SU-B-01 | DC12V power supply, motor-driven, dual electric control + mechanical emergency unlocking mode, built-in lock bolt status, door status and anti-pry detection feedback, bolt stroke ≥15mm, pull resistance ≥300kgf, anti-technical opening time ≥5min, service life ≥500,000 times, operating temperature -20℃~70℃, 304 stainless steel lock body, IP40 protection grade, matches standard cabinet mounting holes without cabinet modification | 10 | Set | KITOZER | 1 set per cabinet door with integrated handle design, no cabinet renovation required |
| 4 | High-Sensitivity Door Magnet + Anti-Pry Sensor | KTZ-MC-B-01 | Normally closed type integrating door status detection + vibration anti-pry detection, compatible with DC12V, operating distance ≥20mm, adjustable vibration sensitivity, trigger response time ≤100ms, ABS flame-retardant housing, service life ≥1 million times, operating temperature -30℃~80℃ | 10 | Set | KITOZER | 1 set per cabinet to monitor real-time door status and forced prying behaviors |
| 5 | Cabinet Internal Exit Button + Emergency Break-Glass Button | KTZ-AN-B-01 | Includes self-reset exit button + glass break emergency button, dual normally open/closed modes, ABS flame-retardant material, standard 86-type size, press service life ≥500,000 times, break-glass button self-locks after triggering requiring key reset, compatible with DC12V control circuit | 10 | Set | KITOZER | 1 set installed inside each cabinet for daily unlocking and emergency unlocking |
| 6 | Dedicated Regulated Access Control Power Supply with Backup Battery | KTZ-DY-B-01 | AC220V input, DC12V/5A output, over-current, over-voltage, short-circuit and lightning protection, built-in 12V/7AH lead-acid battery, automatic backup power switch upon mains failure with endurance ≥4 hours, operating temperature -10℃~60℃, efficiency ≥90% with power status monitoring | 3 | Set | KITOZER | 1 set matched with each main controller for centralized power supply and redundancy guarantee |
| 7 | High-Volume Audible & Visual Voice Alarm | KTZ-BJ-B-01 | DC12V power supply, alarm volume ≥120dB, dual red-blue stroboscopic warning lights, built-in pre-recorded deterrent voice supporting custom voice input, open/closed/RS485 trigger modes optional, operating temperature -20℃~70℃, metal housing, IP40 protection grade | 2 | Set | KITOZER | 2 sets deployed diagonally in the computer room for dead-angle-free alarm coverage |
| 8 | Cabinet Internal Linked Lighting Module | KTZ-ZM-B-01 | DC12V power supply, LED cold light source, automatic lighting upon door opening with 30s delay off after door closure, brightness ≥300lm, service life ≥50,000 hours, flame-retardant housing suitable for internal cabinet installation | 10 | Set | KITOZER | 1 set installed inside each cabinet to link lighting upon unlocking and improve operation & maintenance convenience |
| 9 | Intermediate Grade Access Control Management Platform | KTZ-RJ-B-01 | Dual B/S+C/S architecture, compatible with Windows/Linux systems, supports user hierarchical management, refined authority configuration, full event log storage, intelligent alarm push, automatic report generation, video linkage and environmental monitoring system docking, connects up to 500 access control devices with multi-terminal access support | 1 | Set | KITOZER | 1 set deployed on computer room management server, permanent authorization with free upgrades including mobile APP |
| 10 | National Secret CPU Card Issuer | KTZ-FK-B-01 | Dual USB/RS232 interface plug-and-play, supports read-write of 13.56MHz national secret CPU cards complying with GM/T national secret standard, compatible with access control management platform, DC5V power supply, card reading distance 3~5cm, operating temperature 0℃~50℃ | 1 | Set | KITOZER | 1 set deployed at management center for card issuing, key management and authority configuration |
| 11 | National Secret Blank CPU Card | KTZ-KA-B-01 | 13.56MHz national secret security chip, complies with ISO 14443 and GM/T national secret standards, supports two-way anti-duplication authentication, rewritable ≥100,000 times, data storage ≥10 years | 100 | Pc | KITOZER | Configured per user quantity including administrator cards, operation & maintenance cards and spare cards |
| 12 | Industrial-Grade Network Switch | KTZ-JH-B-01 | 8-port full Gigabit industrial switch, dual DC12V/AC220V power supply, IP40 protection grade, operating temperature -20℃~70℃, lightning surge protection, DIN rail mounting for access control system networking | 1 | Set | KITOZER | 1 set deployed in computer room for access controller networking communication |
| 13 | Cabinet Installation Auxiliary Material Package | KTZ-FC-B-01 | Includes RVV2×1.5 power cable, RVVP6×0.75 shielded signal cable, Cat5e network cable, wiring terminals, expansion bolts, cable ties, insulating tape, galvanized wire conduits, wire troughs and full set of flame-retardant installation auxiliary materials suitable for wiring of 10 cabinets | 1 | Set | KITOZER | Specifications and quantities of auxiliary materials adjustable per actual installation scenario |
5.4 High-Grade Protection System Configuration List (Class A, Multi-Factor Authentication, High-Security Protection, Equal Compliance)
| Serial No. | Product Name | Model Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | National Secret Grade Cabinet Access Main Controller (Dual-Machine Hot Standby) | KTZ-MJ-A-01 | Industrial-grade ARM Cortex-A7 dual-core main control chip with built-in national secret SM4 encryption chip, DC12V/24V dual redundant power supply, triple TCP/IP+RS485+4G communication, max 8-door control, encrypted Wiegand/OSDP protocol, storage for 200,000 user cards/biometric templates and 1 million encrypted event records, operating temperature -40℃~85℃, humidity 0~95% non-condensing, lightning surge, over-current, over-voltage, anti-disassembly and anti-tampering protection, supports dual-machine hot standby, offline operation, duress alarm, anti-passback and anti-tailgating, complies with GB/T 39786-2021 Class 3 national secret standard | 2 | Set | KITOZER | Primary-backup dual machine redundant configuration; one unit manages max 8 cabinets, 2 sets configured for 10 cabinets with automatic failure switching for zero interruption |
| 2 | Face + Fingerprint + IC Card Three-Factor National Secret Recognition Terminal | KTZ-DK-A-01 | 2MP binocular camera + semiconductor fingerprint sensor + national secret CPU card triple-in-one, supports combined multi-factor authentication of face + fingerprint + card swiping, infrared living body detection to counterfeit photos/videos/3D masks, face recognition accuracy ≥99.99%, recognition time ≤0.3s, fingerprint false rejection rate ≤0.1%, false acceptance rate ≤0.001%, supports national secret SM4 encrypted transmission, Wiegand/RS485/TCP/IP output, DC12V wide voltage power supply, operating temperature -30℃~60℃, IP54 protection grade, full metal explosion-proof housing with anti-disassembly alarm and anti-violent damage design | 10 | Set | KITOZER | 1 set embedded anti-pry installation on each cabinet door for high-security scenarios |
| 3 | Dedicated Cabinet Anti-Pry Explosion-Proof Intelligent Lock | KTZ-SU-A-01 | DC12V/24V wide voltage power supply, motor-driven, triple electric control + mechanical emergency + passive emergency unlocking modes, built-in multi-sensor detection for lock bolt status, door status, anti-pry, false lock and tilt with real-time status feedback, bolt stroke ≥20mm, static pull resistance ≥500kgf, anti-technical opening time ≥10min, anti-violent opening time ≥30min, service life ≥1 million times, operating temperature -40℃~85℃, 304 stainless steel lock body + zinc alloy die-cast housing, IP55 protection grade, complies with GA 374-2019 Grade B anti-theft lock standard | 10 | Set | KITOZER | 1 set per cabinet door with heavy anti-pry explosion-proof design for core computer room high-security demands |
| 4 | Multi-Sensor Fusion Status Monitoring Module | KTZ-CJ-A-01 | Integrates door magnetic switch, lock bolt status sensor, high-sensitivity vibration sensor, tilt sensor, anti-disassembly sensor and false lock detection sensor, DC12V power supply, RS485 communication, vibration sensitivity ≤0.5g, tilt detection accuracy ±0.1°, trigger response time ≤50ms with customizable threshold settings, operating temperature -40℃~85℃, PCB triple anti-corrosion treatment, IP50 protection grade | 10 | Set | KITOZER | 1 set per cabinet for full-dimensional monitoring of cabinet door and lock status to identify unauthorized intrusion behaviors |
| 5 | Exit Button + Emergency Break-Glass + Duress Alarm Button Suite | KTZ-AN-A-01 | Includes self-reset exit button, glass break emergency button and concealed duress alarm button, dual normally open/closed modes, metal flame-retardant material, standard 86-type size, press service life ≥500,000 times, self-locking break-glass button requiring key reset, silent alarm support for duress button, compatible with DC12V control circuit with anti-disassembly design | 10 | Set | KITOZER | 1 set installed inside each cabinet covering full scenarios of daily unlocking, emergency unlocking and duress alarm |
| 6 | Redundant Dedicated Access Control Power Supply System (UPS Backup) | KTZ-DY-A-01 | Dual AC220V mains input, DC12V/10A regulated output, over-current, over-voltage, short-circuit, over-temperature, lightning surge and reverse connection protection, built-in two groups of 12V/12AH colloid batteries with automatic backup power switch upon mains failure and endurance ≥8 hours, supports remote power status monitoring and low battery alarm, operating temperature -20℃~70℃, efficiency ≥95%, industrial-grade design with DIN rail mounting | 2 | Set | KITOZER | Primary-backup dual power redundant configuration for centralized power supply to guarantee continuous system operation upon power failure |
| 7 | Industrial-Grade Audible & Visual Voice Alarm System | KTZ-BJ-A-01 | DC12V/24V wide voltage power supply, alarm volume ≥130dB, dual red-blue high-brightness stroboscopic warning lights with night visible distance ≥500 meters, built-in TTS speech synthesis module supporting custom alarm voice, multi-alarm modes optional via RS485/TCP/IP remote control, operating temperature -40℃~85℃, full metal explosion-proof housing, IP55 protection grade | 2 | Set | KITOZER | 2 sets deployed diagonally in the computer room with high-volume alarms for dual functions of deterrence and notification |
| 8 | Intelligent Cabinet Lighting + Video Capture Linkage Suite | KTZ-LP-A-01 | Includes 2MP infrared night vision serial capture camera + LED intelligent lighting, DC12V power supply, automatic capture of 3 1080P high-definition images and lighting activation upon unlocking/alarm triggering, images overlaid with timestamp, cabinet ID and event type information, supports infrared night vision for clear imaging without ambient light, lighting brightness ≥500lm, service life ≥50,000 hours, IP40 protection grade | 10 | Set | KITOZER | 1 set installed inside each cabinet to link lighting upon unlocking and capture evidence upon alarms for full event forensics |
| 9 | High-Fidelity Audio Pickup | KTZ-SY-A-01 | DC12V power supply, omnidirectional sound pickup distance ≥5 meters, frequency response 20Hz~20kHz, signal-to-noise ratio ≥60dB with built-in noise reduction algorithm, supports linkage recording upon alarms, PCB triple anti-corrosion treatment, IP40 protection grade | 10 | Pc | KITOZER | 1 pc installed per cabinet to realize synchronous audio-video evidence collection with cameras |
| 10 | High-Grade National Secret Access Control Management Platform (Equal Compliance) | KTZ-RJ-A-01 | Domestic B/S architecture compatible with domestic operating systems and databases, complies with Class 2.0 Equal Protection and Class 3 National Secret standards, supports user hierarchical decentralized management, refined authority configuration, full-link encryption, full-event audit logs, intelligent graded alarms, automatic report generation, multi-system linkage integration, data backup & recovery and disaster recovery backup functions, connects unlimited access control devices with centralized multi-computer room cross-region management, supports Web, mobile APP and mini-program multi-terminal access, provides API interface to dock third-party systems | 1 | Set | KITOZER | 1 set deployed on computer room management server, permanent authorization with free upgrades including confidentiality evaluation adaptation service |
| 11 | Dedicated National Secret CPU Card Issuer | KTZ-FK-A-01 | Triple USB/RS232/Ethernet interface, supports national secret SM1/SM2/SM3/SM4 algorithms complying with GM/T national secret standards, full-function read-write of 13.56MHz national secret CPU cards with decentralized key management and one card one secret, compatible with national secret access control management platform, DC5V power supply, card reading distance 3~5cm, operating temperature 0℃~50℃, certified by national secret authority | 1 | Set | KITOZER | 1 set deployed at management center for card issuing, key management and authority configuration |
| 12 | National Secret CPU User Card | KTZ-KA-A-01 | 13.56MHz national secret security chip, complies with ISO 14443 and GM/T national secret standards, supports two-way identity authentication, one card one secret, anti-duplication and anti-tampering, rewritable ≥100,000 times, data storage ≥10 years, certified by national secret authority | 200 | Pc | KITOZER | Configured per user quantity including administrator cards, operation & maintenance cards, temporary cards and spare cards |
| 13 | Industrial-Grade Gigabit Ring Network Switch | KTZ-JH-A-01 | 16-port full Gigabit industrial ring network switch, dual AC220V/DC12~48V wide voltage power supply, supports ring network redundancy and link aggregation, IP40 protection grade, operating temperature -40℃~85℃, lightning surge protection, DIN rail mounting for high-reliability networking demands | 1 | Set | KITOZER | 1 set deployed in computer room for access control system ring network networking to guarantee stable communication |
| 14 | Fire Linkage Control Module | KTZ-LD-A-01 | DC12V power supply, 8-channel fire signal input and 8-channel relay output, supports dry contact signal access to automatically unlock cabinet locks in corresponding areas upon receiving fire alarm signals, RS485 communication with status feedback, operating temperature -20℃~70℃, PCB triple anti-corrosion treatment | 1 | Set | KITOZER | 1 set deployed in computer room to realize emergency linkage between access control system and fire system complying with fire protection codes |
| 15 | Environmental Monitoring System Docking Gateway | KTZ-WG-A-01 | Industrial-grade gateway supporting TCP/IP, RS485 and Modbus protocols to realize seamless docking and two-way data interaction between access control system and KITOZER environmental monitoring system & DCIM platform for linkage control, DC12V power supply, operating temperature -40℃~85℃ with customizable protocol development support | 1 | Set | KITOZER | 1 set deployed in computer room for multi-system integrated linkage to build an integrated computer room protection system |
| 16 | High-Grade Cabinet Installation Auxiliary Material Package | KTZ-FC-A-01 | Includes flame-retardant RVV2×1.5 power cable, double-shielded RVVP8×0.75 signal cable, Cat6 shielded network cable, waterproof wiring terminals, stainless steel expansion bolts, flame-retardant cable ties, insulating tape, thickened galvanized wire conduits, fireproof wire troughs, lightning grounding terminals and full set of installation auxiliary materials complying with computer room fire protection standards, suitable for wiring of 10 cabinets with customization available | 1 | Set | KITOZER | Specifications and quantities of auxiliary materials adjustable per actual installation scenario to meet construction standards of high-grade computer rooms |
6. Full Product Technical Parameters
6.1 Technical Parameters of Access Controller Series
| Model | Parameter Category | Detailed Technical Parameters |
|---|---|---|
| KTZ-MJ-C-01 | Hardware Parameters | Industrial-grade 32-bit main control chip, RAM ≥64KB, Flash ≥2MB, DC12V±10% power supply, operating current ≤100mA (standby)/≤500mA (working), 8-channel switch input, 4-channel relay output, 1 Wiegand interface, 1 RS485 interface, 1 TCP/IP Ethernet interface |
| KTZ-MJ-C-01 | Functional Parameters | Single-door control, storage for 10,000 user cards and 100,000 event records, supports card swiping and password authentication modes, alarms for door open timeout, unauthorized intrusion and anti-disassembly, supports offline operation with automatic data synchronization after network recovery, remote door opening and time period authority management |
| KTZ-MJ-C-01 | Environmental Parameters | Operating temperature -10℃~60℃, storage temperature -20℃~70℃, operating humidity 0~95% (non-condensing), IP30 protection grade, electrostatic interference resistance ±15kV, group pulse interference resistance ±2kV |
| KTZ-MJ-B-01 | Hardware Parameters | Industrial-grade ARM Cortex-M4 main control chip, RAM ≥256KB, Flash ≥8MB, DC12V±15% wide voltage power supply, operating current ≤150mA (standby)/≤800mA (working), 16-channel switch input, 8-channel relay output, 4 Wiegand interfaces, 2 RS485 interfaces, 1 TCP/IP Ethernet interface, 1 USB interface |
| KTZ-MJ-B-01 | Functional Parameters | Max 4-door control, storage for 50,000 user cards/fingerprint templates and 500,000 event records, supports multi-factor authentication including card swiping, fingerprint and password, anti-passback, anti-tailgating, alarms for door open timeout, false lock and anti-pry, duress alarm and fire linkage, offline operation and multi-terminal management support |
| KTZ-MJ-B-01 | Environmental Parameters | Operating temperature -20℃~70℃, storage temperature -40℃~85℃, operating humidity 0~95% (non-condensing), IP40 protection grade, electrostatic interference resistance ±15kV, group pulse interference resistance ±2kV, lightning surge resistance ±4kV |
| KTZ-MJ-A-01 | Hardware Parameters | Industrial-grade ARM Cortex-A7 dual-core main control chip with built-in national secret SM4 encryption chip, RAM ≥512MB, Flash ≥8GB, DC12V/24V±20% dual redundant power supply, operating current ≤200mA (standby)/≤1000mA (working), 32-channel switch input, 16-channel relay output, 8 Wiegand interfaces, 4 RS485 interfaces, 2 TCP/IP Ethernet interfaces, 1 4G wireless interface, 1 USB interface |
| KTZ-MJ-A-01 | Functional Parameters | Max 8-door control, encrypted storage for 200,000 user cards/biometric templates and 1 million event records, supports combined multi-factor authentication of face, fingerprint, card swiping, password and Bluetooth, dual-machine hot standby, anti-passback, anti-tailgating, multi-door interlock, duress alarm, fire linkage and anti-disassembly & anti-tampering functions, full-link national secret encryption complying with Class 3 GB/T 39786-2021 standard, customized API interface development support |
| KTZ-MJ-A-01 | Environmental Parameters | Operating temperature -40℃~85℃, storage temperature -40℃~85℃, operating humidity 0~95% (non-condensing), IP50 protection grade, electrostatic interference resistance ±15kV, group pulse interference resistance ±2kV, lightning surge resistance ±6kV, vibration resistance complies with GB/T 2423 standard |
6.2 Technical Parameters of Identity Recognition Terminal Series
| Model | Parameter Category | Detailed Technical Parameters |
|---|---|---|
| KTZ-DK-C-01 | Hardware Parameters | ABS flame-retardant housing, DC12V±10% power supply, operating current ≤50mA (standby)/≤100mA (working), 1 Wiegand 26/34 output interface, 1 LED indicator light, 1 buzzer |
| KTZ-DK-C-01 | Performance Parameters | Supports 13.56MHz IC cards complying with ISO 14443A standard, card reading distance 3~8cm, response time ≤100ms, compatible with M1 cards, UID cards and CPU cards (compatibility mode) |
| KTZ-DK-C-01 | Environmental Parameters | Operating temperature -10℃~60℃, storage temperature -20℃~70℃, operating humidity 0~95% (non-condensing), IP30 protection grade |
| KTZ-DK-B-01 | Hardware Parameters | Metal + ABS flame-retardant housing, DC12V±15% power supply, operating current ≤80mA (standby)/≤150mA (working), 1 Wiegand/RS485 output interface, 2 LED indicator lights, 1 buzzer, anti-disassembly switch |
| KTZ-DK-B-01 | Performance Parameters | Semiconductor capacitive fingerprint sensor with 508DPI resolution, fingerprint recognition time ≤0.5s, false rejection rate ≤0.1%, false acceptance rate ≤0.001%, supports 13.56MHz IC/CPU cards complying with ISO 14443 standard, card reading distance 3~10cm, response time ≤80ms, supports fingerprint + card swiping dual-factor authentication |
| KTZ-DK-B-01 | Environmental Parameters | Operating temperature -20℃~60℃, storage temperature -40℃~85℃, operating humidity 0~95% (non-condensing), IP40 protection grade, electrostatic interference resistance ±15kV |
| KTZ-DK-A-01 | Hardware Parameters | Full metal explosion-proof housing, DC12V±20% wide voltage power supply, operating current ≤100mA (standby)/≤200mA (working), Wiegand/RS485/TCP/IP communication interface, 3 LED indicator lights, 1 voice speaker, anti-disassembly switch, 2MP binocular camera with infrared fill light, semiconductor fingerprint sensor |
| KTZ-DK-A-01 | Performance Parameters | Binocular face recognition with infrared living body detection to counterfeit photos/videos/3D masks, face recognition accuracy ≥99.99%, recognition time ≤0.3s, storage for ≥10,000 face templates; semiconductor fingerprint sensor with 508DPI resolution, fingerprint recognition time ≤0.5s, false rejection rate ≤0.1%, false acceptance rate ≤0.001%; supports national secret CPU cards complying with ISO 14443 and GM/T national secret standards, card reading distance 3~10cm, national secret SM4 encrypted transmission support, combined multi-factor authentication of face + fingerprint + card swiping |
| KTZ-DK-A-01 | Environmental Parameters | Operating temperature -30℃~60℃, storage temperature -40℃~85℃, operating humidity 0~95% (non-condensing), IP54 protection grade, electrostatic interference resistance ±15kV, vibration resistance complies with GB/T 2423 standard |
6.3 Technical Parameters of Cabinet Lock Series
| Model | Parameter Category | Detailed Technical Parameters |
|---|---|---|
| KTZ-SU-C-01 | Hardware Parameters | 304 stainless steel bolt + zinc alloy lock body, DC12V±10% power supply, operating current ≤200mA (standby)/≤800mA (action), lock body size matches standard cabinet mounting holes with lock status feedback signal output |
| KTZ-SU-C-01 | Performance Parameters | Static pull force ≥180kg, residual suction ≥10%, power-off lock type with no mechanical wear, service life ≥1 million times, bolt action response time ≤1s, anti-technical opening time ≥1min |
| KTZ-SU-C-01 | Environmental Parameters | Operating temperature -20℃~60℃, storage temperature -30℃~70℃, operating humidity 0~95% (non-condensing), IP30 protection grade |
| KTZ-SU-B-01 | Hardware Parameters | 304 stainless steel lock body + zinc alloy die-cast handle, DC12V±15% power supply, operating current ≤100mA (standby)/≤500mA (action), built-in sensors for lock bolt status, door status and anti-pry detection with signal output interface, mechanical emergency key hole, matches standard cabinet mounting holes without cabinet modification |
| KTZ-SU-B-01 | Performance Parameters | Motor-driven dual electric control + mechanical emergency unlocking mode, bolt stroke ≥15mm, static pull resistance ≥300kgf, anti-technical opening time ≥5min, service life ≥500,000 times, bolt action response time ≤0.5s, supports false lock detection and anti-pry alarm with 100% accurate status feedback |
| KTZ-SU-B-01 | Environmental Parameters | Operating temperature -20℃~70℃, storage temperature -40℃~85℃, operating humidity 0~95% (non-condensing), IP40 protection grade, salt spray test ≥48h |
| KTZ-SU-A-01 | Hardware Parameters | 304 stainless steel lock body + zinc alloy explosion-proof housing, DC12V/24V±20% wide voltage power supply, operating current ≤150mA (standby)/≤600mA (action), built-in multi-sensor detection for lock bolt status, door status, anti-pry, false lock and tilt with RS485 status feedback interface, dual mechanical + passive emergency unlocking modes, matches standard cabinet mounting holes |
| KTZ-SU-A-01 | Performance Parameters | Motor-driven triple electric control + mechanical emergency + passive emergency unlocking modes, bolt stroke ≥20mm, static pull resistance ≥500kgf, anti-technical opening time ≥10min, anti-violent opening time ≥30min, service life ≥1 million times, bolt action response time ≤0.3s, full real-time status feedback support, complies with GA 374-2019 Grade B anti-theft lock standard |
| KTZ-SU-A-01 | Environmental Parameters | Operating temperature -40℃~85℃, storage temperature -40℃~85℃, operating humidity 0~95% (non-condensing), IP55 protection grade, salt spray test ≥96h, vibration resistance complies with GB/T 2423 standard |
6.4 Technical Parameters of Power Supply & Supporting Equipment Series
| Model | Parameter Category | Detailed Technical Parameters |
|---|---|---|
| KTZ-DY-C-01 | Electrical Parameters | AC180V~240V input, DC12V/3A stable output, voltage regulation rate ≤1%, load regulation rate ≤2%, efficiency ≥85%, over-current, over-voltage, short-circuit and reverse connection protection |
| KTZ-DY-C-01 | Functional Parameters | Supports backup battery access with automatic power switch upon mains failure, power status indicator light, operating temperature -10℃~60℃, storage temperature -20℃~70℃, flame-retardant housing with wall-mounted installation |
| KTZ-DY-B-01 | Electrical Parameters | AC170V~260V input, DC12V/5A stable output, voltage regulation rate ≤0.5%, load regulation rate ≤1%, efficiency ≥90%, over-current, over-voltage, short-circuit, over-temperature and lightning surge protection |
| KTZ-DY-B-01 | Functional Parameters | Built-in 12V/7AH lead-acid battery with automatic backup power switch upon mains failure and endurance ≥4 hours, battery overcharge & overdischarge protection, remote power status monitoring and low battery alarm support, operating temperature -10℃~60℃, metal flame-retardant housing with wall-mounted/DIN rail mounting |
| KTZ-DY-A-01 | Electrical Parameters | Dual AC160V~280V mains input, DC12V/10A stable output, voltage regulation rate ≤0.2%, load regulation rate ≤0.5%, efficiency ≥95%, over-current, over-voltage, short-circuit, over-temperature, lightning surge and reverse connection protection |
| KTZ-DY-A-01 | Functional Parameters | Built-in two groups of 12V/12AH colloid batteries with dual redundant power design and automatic backup power switch upon mains failure and endurance ≥8 hours, intelligent battery charge-discharge management, overcharge & overdischarge protection, battery health status monitoring, remote real-time power status monitoring and low battery alarm support, operating temperature -20℃~70℃, industrial-grade metal housing with DIN rail mounting |
| KTZ-BJ-C-01 | Electrical Parameters | DC12V±10% power supply, operating current ≤150mA (standby)/≤300mA (alarm), open/closed trigger mode optional |
| KTZ-BJ-C-01 | Performance Parameters | Alarm volume ≥100dB, red LED stroboscopic warning light, operating temperature -20℃~60℃, ABS flame-retardant housing with wall-mounted installation |
| KTZ-BJ-B-01 | Electrical Parameters | DC12V±15% power supply, operating current ≤200mA (standby)/≤500mA (alarm), open/closed/RS485 trigger mode optional |
| KTZ-BJ-B-01 | Performance Parameters | Alarm volume ≥120dB, dual red-blue stroboscopic warning lights, built-in pre-recorded deterrent voice supporting custom voice input, operating temperature -20℃~70℃, metal housing, IP40 protection grade with wall-mounted installation |
| KTZ-BJ-A-01 | Electrical Parameters | DC12V/24V±20% wide voltage power supply, operating current ≤250mA (standby)/≤600mA (alarm), open/closed/RS485/TCP/IP trigger mode optional |
| KTZ-BJ-A-01 | Performance Parameters | Alarm volume ≥130dB, dual red-blue high-brightness stroboscopic warning lights with night visible distance ≥500 meters, built-in TTS speech synthesis module supporting custom alarm voice and multi-alarm mode selection, operating temperature -40℃~85℃, full metal explosion-proof housing, IP55 protection grade with wall-mounted installation |
7. Full Product Application Scope
The full range of KITOZER cabinet anti-theft access control products cover indoor full-scenario cabinet protection demands, with core application scopes as follows:
7.1 Data Center & Computer Room Scenarios
- Server cabinets, network cabinets, storage cabinets and security equipment cabinets in Internet Data Centers (IDC), operator data centers and enterprise self-built data centers;
- Core business cabinets, confidential cabinets and power distribution cabinets in central computer rooms, branch computer rooms and disaster recovery computer rooms of government, financial, state-owned enterprise and public institution clients;
- Cabinet clusters, column head cabinets and precision power distribution cabinets of computer room cold aisle and hot aisle sealing systems for access control protection and authority management.
7.2 Industrial & Automation Scenarios
- PLC control cabinets, frequency converter cabinets, industrial control cabinets, instrument cabinets and industrial robot control cabinets in intelligent manufacturing factories and automated production lines;
- Switch cabinets, control cabinets, protection panel cabinets and metering cabinets in power industry substations, distribution stations and switching stations;
- On-site control cabinets, DCS system cabinets, SCADA system cabinets and remote measurement & control cabinets in petrochemical, metallurgy, mining, water supply & drainage and environmental protection industries;
- Signal cabinets, monitoring cabinets, communication cabinets and toll system cabinets for rail transit, expressways, tunnels and airports.
7.3 Communication & Network Scenarios
- Cabinets, transmission equipment cabinets and power cabinets in telecommunication, mobile, Unicom and radio & television operator communication base stations, edge stations and access network computer rooms;
- Outdoor integrated cabinets, smart light pole cabinets, video surveillance cabinets and IoT gateway cabinets in smart cities, smart parks and smart transportation;
- Network computer room, weak current room cabinets, floor distribution cabinets and security monitoring cabinets of enterprises, office parks and office buildings.
7.4 Financial & Commercial Scenarios
- Computer room cabinets and self-service equipment control cabinets in bank head offices, branches, sub-branches, self-service banks and ATM protection cabins;
- Computer room cabinets, trading system cabinets and data storage cabinets of securities, insurance, trust and other financial institutions;
- Weak current room cabinets, security cabinets and building automation cabinets of chain shopping malls, hotels, office buildings and commercial complexes.
7.5 Medical & Education Scenarios
- Computer room cabinets, PACS system cabinets, HIS system cabinets and medical equipment control cabinets of Grade A tertiary hospitals, specialized hospitals and community health service centers;
- Campus network computer rooms, multimedia classroom cabinets, recording & broadcasting classroom cabinets, security monitoring cabinets and examination system cabinets of universities, primary & secondary schools and vocational colleges.
7.6 Special & Customized Scenarios
- Confidential computer room cabinets, scientific research equipment cabinets and test equipment cabinets of confidential institutions, military enterprises and research institutes with customized confidential development support;
- Cultural relic warehouse cabinets, security monitoring cabinets and constant temperature & humidity system control cabinets of archives, museums, libraries and art galleries;
- Energy storage container cabinets, photovoltaic power station control cabinets and charging pile control cabinets of new energy industry;
- Access control system adaptation and customized development for all types of non-standard cabinets, supporting OEM/ODM processing services.
8. Full Product Advantages
8.1 Core Functional Features of Full-Series Products
8.1.1 Full-Dimensional Security Protection for Zero-Risk Control
- Multi-factor identity authentication: Freely combine card swiping, password, fingerprint, finger vein, face, Bluetooth and electronic key authentication modes, configure single/two/multi-factor authentication strategies according to cabinet security levels to realize graded protection and eliminate risks of identity counterfeiting and authority theft.
- Real-time full-status monitoring: Integrate multi-sensor fusion monitoring including door magnet, lock bolt status, vibration, tilt, anti-disassembly and false lock sensors to identify forced prying, unauthorized door opening, door open timeout and incomplete locking abnormal behaviors in real time, trigger alarms within seconds for early intrusion warning and full controllability.
- National secret grade secure encryption: High-grade products are equipped with built-in national secret security chips adopting national secret SM1/SM2/SM3/SM4 encryption algorithms to realize full-link encrypted transmission and storage of identity information, control instructions and event data, one card one secret and two-way authentication to defend against data theft, tampering and replay attacks, complying with national Class 2.0 Equal Protection, confidential information system and Class 3 National Secret standards.
- Full-scenario emergency guarantee: Supports multiple emergency unlocking modes including mechanical emergency unlocking, passive emergency unlocking, break-glass emergency unlocking and fire linkage unlocking, dual redundant power supply and backup battery endurance to cope with extreme scenarios such as power failure and network interruption, guarantee emergency disposal and continuous system operation complying with fire protection codes and computer room safety requirements.
- Intelligent anti-violation control: Supports anti-passback, anti-tailgating, multi-door interlock, duress alarm, time period authority control and hierarchical decentralized management advanced functions to eliminate violations such as tailgating entry without authorization, cross-authority operation and over-time detention. Silent alarm is triggered under duress scenarios to protect personal safety of operation & maintenance staff as well as equipment safety.
8.1.2 Intelligent Operation & Maintenance Management to Reduce Costs & Improve Efficiency
- Full-lifecycle traceability: The system automatically records all door opening/closing, alarm, operation and equipment status events including full-dimensional information of personnel, time, cabinet number, event type and operation result. Data is encrypted for storage without tampering or deletion, supporting log query, report export and audit traceability to meet compliance audit requirements.
- Refined authority management: Supports user hierarchical decentralized management with refined authority configuration for different personnel, cabinets and time periods. Temporary, periodic and one-time authorization is available with remote authority issuance and cancellation, eliminating pain points of traditional mechanical locks such as difficult key management, duplication risks and high operation & maintenance costs.
- Multi-terminal intelligent management: Supports local management terminals, Web management platforms, mobile APP and mini-program multi-terminal access to check equipment status, receive alarm information, remotely authorize door opening and configure system parameters anytime and anywhere, realizing remote unattended computer room operation & maintenance and reducing operation & maintenance costs by over 30%.
- Intelligent alarm & linkage: Supports graded alarm strategies with multi-channel alarm push including audible & visual alerts, SMS, phone calls, APP and platform messages for accurate alarm positioning. It can link video surveillance systems for image capture & recording, link environmental monitoring systems for environmental data linkage and link fire systems for emergency unlocking to build an all-round integrated computer room safety protection system.
- High compatibility & scalability: Adopts standard interfaces and protocols supporting mainstream communication protocols including Wiegand, OSDP, RS485, TCP/IP and Modbus, seamlessly docking the full range of KITOZER integrated cabinets, environmental monitoring systems, DCIM platforms, security systems and operation & maintenance management platforms. Open API interfaces are provided for customized development and function expansion to meet personalized demands of different industries and scenarios.
8.1.3 Industrial-Grade Quality Guarantee for Stable & Reliable Performance
- Strict component selection: Full-series products adopt industrial-grade components and brand chips with core parts undergoing rigorous screening and testing. Lock bodies use 304 stainless steel and zinc alloy die-cast materials, while housings adopt flame-retardant, explosion-proof and anti-corrosion materials. Core circuit boards undergo triple anti-corrosion treatment to adapt to complex electromagnetic environments, wide temperature and high humidity harsh scenarios in computer rooms.
- High-standard production & testing: Product production strictly complies with the ISO9001 quality management system. Every product undergoes more than 20 rigorous tests before factory delivery including high-low temperature cycle test, aging test, vibration test, salt spray test and electromagnetic compatibility test to ensure stable product performance with Mean Time Between Failures (MTBF) ≥100,000 hours, far exceeding the industry average service life.
- Strong anti-interference & protection capability: Full-series products integrate multiple protections including lightning, surge, over-current, over-voltage, over-temperature and short-circuit reverse connection protection, with anti-static interference, group pulse interference and electromagnetic interference resistance complying with relevant national standards. High-grade products reach IP55 protection grade adapting to ultra-wide temperature operating environments of -40℃~85℃ for stable operation in various complex scenarios.
- Redundant design & offline operation: High-grade products support dual-machine hot standby and dual redundant power supply design where failure of a single device will not affect overall system operation. All products support local authority storage and offline authentication & unlocking to operate normally without network coverage and automatically resume broken-point data transmission after network recovery to guarantee uninterrupted system operation.
8.2 Customization & OEM/ODM Processing Service Advantages
- Full-dimensional customized development: Supports full-process customized development covering product hardware, structure, firmware, software and system solutions. Personalized customization can be conducted per user cabinet sizes, mounting holes, security levels, functional demands and docking systems to match all standard and non-standard cabinets and meet customized protection demands of different industries and scenarios.
- Professional OEM/ODM processing service: Equipped with a modern production base and professional R&D team to provide one-stop OEM/ODM processing services for full-series products including cabinet locks, access controllers, identification terminals and management platforms. Supports brand, appearance, function and firmware customization with short delivery cycles, controllable quality and high cost performance covering design, mold opening, production, testing and after-sales.
- Confidential customized service: Provides confidential customized development services for military enterprises, confidential institutions and government departments with high confidentiality demands. Confidentiality agreements are signed with domestic chips, domestic operating systems and national secret grade encryption technology adopted for fully closed production and testing throughout the process to eliminate information leakage and meet high safety and confidentiality demands of confidential scenarios.
- Rapid customized response capability: A professional customized R&D team delivers responses to customized demands within 12 hours, customized schemes within 24 hours, sample development and testing within 7~15 days and mass delivery within 30 days to rapidly respond to user customized demands and project delivery cycles.
8.3 Spot & Supply Chain Advantages
- Full-series spot inventory reserve: A complete spot reserve system is established with large spot inventory maintained for full basic and intermediate grade products. Conventional orders can be shipped within 24 hours to meet rapid delivery demands of emergency projects and renovation works.
- Flexible production capacity: Modern flexible production lines support rapid switching between small-batch customized production and mass standardized production. Mass orders of conventional products are delivered within 7 days while customized mass orders are delivered within 30 days to guarantee project delivery cycles.
- Stable supply chain system: Long-term strategic cooperative relationships are established with domestic and foreign brand chip manufacturers, component suppliers and hardware processing factories with a complete supply chain system and sufficient core component stock to avoid impact from market shortages and price hikes and guarantee stable product supply and delivery.
- National warehousing & logistics system: Warehousing centers are established in multiple core cities nationwide with strategic cooperation with leading logistics enterprises including SF Express and Debang Logistics. Delivery is completed within 3-5 days nationwide and within 7 days in remote areas to guarantee fast and safe product delivery to project sites.
9. Core Bid Control Parameters for All Products (★ Marked Core Bid Control Parameters)
9.1 Core Bid Control Parameters of Access Controllers
- ★ The controller shall adopt industrial-grade 32-bit or above main control chips with built-in national secret SM4 encryption chips complying with Class 3 GB/T 39786-2021 Information Security Technology Basic Requirements for Cryptography Application in Information Systems standard;
- ★ Supports full-protocol communication of TCP/IP, RS485, Wiegand 26/34 and OSDP, flexible single/dual/four/eight-door control with a single controller managing no less than 8 access control points at maximum;
- ★ Supports storage of no less than 200,000 user cards/biometric feature templates and encrypted storage of no less than 1 million event records without data loss upon power failure with storage duration no less than 10 years;
- ★ Equipped with dual-machine hot standby function supporting automatic primary-backup controller switching within ≤500ms without impact on normal system operation to guarantee zero interruption;
- ★ Supports combined multi-factor authentication with configurable combination strategies of card swiping, fingerprint, face and password, with anti-passback, anti-tailgating, multi-door interlock, duress alarm and time period authority control functions;
- ★ Equipped with no less than 16-channel switch input and 16-channel relay output, supporting fire, video and environmental monitoring system linkage to automatically unlock locks in corresponding areas upon receiving fire alarm signals;
- ★ Operating temperature range -40℃~85℃, operating humidity 0~95% non-condensing, with lightning surge, over-current, over-voltage, over-temperature, short-circuit and anti-disassembly protection, electrostatic interference resistance ±15kV and lightning surge resistance ≥±6kV;
- ★ Supports offline operation function to complete local identity verification, lock control and event record storage without network, automatically resume broken-point transmission of all data after network recovery without record loss;
- ★ Provides open API interfaces to seamlessly dock third-party environmental monitoring systems, DCIM platforms, security systems and operation & maintenance management platforms with customized protocol development support;
- ★ Products pass inspection by the National Public Security Alarm System Product Quality Supervision & Inspection Center complying with GB/T 37078-2018 Technical Requirements for Access Control Systems and GA 374-2019 Electronic Locks for Anti-Theft Purposes standards.
9.2 Core Bid Control Parameters of Identity Recognition Terminals
- ★ Supports multiple recognition modes including face, fingerprint, finger vein, IC card and national secret CPU card with combined multi-factor authentication and infrared living body detection to counterfeit photos, videos and 3D mask forgery attacks;
- ★ Face recognition terminals adopt binocular 2MP or above cameras with face recognition accuracy ≥99.99%, recognition time ≤0.3s and storage for ≥10,000 face templates for stable recognition under 0~5000lux illumination environments;
- ★ Fingerprint recognition modules adopt semiconductor capacitive fingerprint sensors with resolution ≥508DPI, fingerprint recognition time ≤0.5s, false rejection rate ≤0.1% and false acceptance rate ≤0.001% with storage for ≥50,000 fingerprint templates;
- ★ Supports 13.56MHz IC cards and national secret CPU cards complying with ISO 14443 and GM/T national secret standards, card reading distance 3~10cm, national secret encrypted transmission support and one-card two-way identity authentication;
- ★ Equipped with anti-disassembly alarm function to automatically trigger alarms and upload to the management platform upon unauthorized disassembly, with anti-pry and anti-violent damage structure and full metal housing protection grade no lower than IP54;
- ★ Operating temperature range -30℃~60℃, operating humidity 0~95% non-condensing, electrostatic interference resistance ±15kV for stable operation in complex computer room electromagnetic environments;
- ★ Supports Wiegand, RS485 and TCP/IP communication protocols compatible with mainstream brand access controllers with national secret encrypted communication to prevent data interception and tampering;
- ★ Products pass inspection