ToggleKITOZER KTR-SD4 Aspirating Smoke Detector / Very Early Warning
Brand: KITOZER Series: KTR-SD4 Category: Environmental Monitoring / Aspirating smoke
Active samplingVery early warningLaser scatterTwo-stage alarmRS485
1. Overview
By the time a data-center fire produces visible smoke, damage is already done. Traditional point smoke detectors sit on the ceiling and wait for smoke to rise, which lags. Aspirating smoke detection (ASD) actively draws air from inside racks and cold aisles through sampling pipes and uses laser scatter to detect trace smoke particles in the smoldering stage, giving staff an early window to act.
The KITOZER KTR-SD4 is an aspirating very-early smoke detector with four sampling channels, up to 100 m and up to 25 holes per channel. Laser scatter measures 0.005 to 2%/m adjustable, split into pre-alarm and fire alarm levels. RS485 Modbus connects to DCIM; relay outputs link suppression/exhaust. LCD display and filter blockage monitoring. DC24V power. Suits data centers, power rooms and battery rooms.
Selection confirms: channels (single/4), protected area, pipe routing (above rack rows), sensitivity levels (pre/fire thresholds), whether to link clean-gas suppression, and RS485 integration. Critical rooms use 4 channels to cover a whole row; holes are evenly placed 0.3 to 0.5 m above racks.
2. Key Features
Active sampling
- 4-channel pipe sampling.
- Up to 100 m, 25 holes per channel.
- Captures early smoke inside racks.
- Does not rely on smoke rising.
High-sensitivity detection
- Laser scatter principle.
- 0.005 to 2%/m adjustable.
- Pre-alarm / fire alarm two stages.
- Ambient self-compensation.
Integration and linkage
- RS485 Modbus.
- Dry relay outputs.
- Links suppression/exhaust/alarm.
- Filter blockage monitoring.
3. Specifications
| Item | KTR-SD4 Aspirating Detector |
|---|---|
| 探测原理 | 主动吸气+激光散射 |
| 采样孔数量 | 4路,每路≤25个孔 |
| 采样管长度 | 每路最长100m |
| 灵敏度 | 0.005~2%/m可调 |
| 告警级数 | 预警/火警两级 |
| 通信 | RS485 Modbus + 继电器 |
| 过滤器 | 可更换防尘滤棉 |
| 供电 | DC24V |
| 显示 | LCD + 指示灯 |
| 自检 | 自动环境补偿 |
4. Reference Prices
KTR-SD4 aspirating smoke detector (4-channel): USD 625~1085 (ref. CNY 4500~7800 at ~7.2)
Sampling tube (per meter): USD 2~4 (ref. CNY 15~30 at ~7.2)
Sampling hole kit + filter: USD 28~55 (ref. CNY 200~400 at ~7.2)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Tubing and holes billed separately. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Very-early fire warning in data centers.
- Power and battery room monitoring.
- Archives and museum vaults.
- Telecom sites and outdoor cabinets.
- Semiconductor and clean rooms.
6. Installation & Maintenance
Installation
- Wall-mount the unit near the entrance.
- Route sampling pipe above rack rows.
- Drill 4 mm holes per design.
- End-cap and connect to unit ports.
- Power on self-test; set sensitivity.
- Wire RS485 and relays to DCIM.
Maintenance
- Check filter differential quarterly.
- Replace filter annually.
- Blow out sampling holes.
- Test sensitivity with reference smoke.
- Inspect pipe leakage.
7. FAQ
- Q: Difference vs point detectors?
A: Points wait for smoke to reach the ceiling; ASD samples inside racks and warns at smoldering stage, tens of minutes earlier. - Q: Many false alarms?
A: Dusty rooms can trigger false alarms; change filters and tune sensitivity. ASD uses self-compensation and pollution trend algorithms to reduce false calls. - Q: How long a sampling pipe?
A: Up to 100 m per channel within fan rating; add detectors or split beyond that. - Q: What on pre-alarm?
A: Pre-alarm means trace smoke; inspect rack hot spots. Only fire alarm triggers suppression. Graded response avoids unwanted discharge.
8. Trend & Selection
Data-center fire safety moves toward very-early warning; aspirating detection becomes standard in high-value rooms and links to clean-gas suppression. Choose 4 channels; laser scatter; two-stage alarm; RS485; filter monitoring; evenly spaced holes. It moves fire detection from “after smoke” to “during smolder”.
9. Delivery & Service
KITOZER supplies the KTR-SD4 detector including unit, sampling pipe, hole kit, filter, certificate and manual. Piping design and DCIM integration guidance are provided.
10. Notes
A common pitfall is drilling holes in the aisle rather than above racks. Holes should aim at rack intakes or hot spots, otherwise rack smoke is not sampled.
Another pitfall is never changing the filter. A clogged filter reduces airflow and sensitivity, even suppressing alarms. Replace annually.
Selection summary: 4-channel aspiration; laser scatter; 0.005 to 2%/m; two-stage alarm; RS485; DC24V. It is the nose of data-center fire safety.
Systemically, very-early warning lets staff power down and investigate during smolder, avoiding equipment burn-out and cutting loss by over 90%.
Cost-wise, an ASD costs about 6000 CNY against a fire loss of hundreds of thousands to millions, outstanding insurance.