Brand: KITOZER Series: KTR-WL4 Category: Environmental Monitoring / Leak Detection
Positioning leak rope20m1m accuracyRS485DCIM integrationvs non-locating
1. Overview
Water leaks are the third-largest data center risk after power loss and fire. Precision AC condensate, chilled-pipe condensation, and plumbing leaks — once water reaches a server rack, it means batch short-circuiting and scrapped gear. Leak detection systems lay sensing rope under floors, around AC units, and along pipes; on water they alarm immediately and tell ops “where it leaks.” Ropes come in two types: non-locating (only “water on the rope,” not where) and locating (“leak at X meters from controller”). Locating rope costs more but pinpoints the leak so ops needn’t lift floor tiles inch by inch — essential in large halls.
KITOZER KTR-WL4 is a positioning leak detection rope, standard 20 m per roll (daisy-chain extendable to 100 m). Inside are four conductive sensing wires; the controller measures line-to-line resistance change to locate the leak. Locating accuracy ±1 m; the leak distance in meters is uploaded to DCIM via RS485 (Modbus RTU). Rope diameter about 6 mm, acid/alkali resistant, bendable, laid under floor or around AC. A matching locating controller (KTR-WL4C) powers and samples the rope, with relay output (to trigger a sounder or close the AC water valve). The rope is dry-insulating; on water (or conductive liquid) lines conduct and alarm — clean water and condensate both detected.
Selection points: detection type (locating vs non-locating; large halls choose locating), rope length (by laid perimeter — around AC + along pipes, with 10% spare), controller channels (one controller per rope; multi-channel for multiple runs), communication (RS485/Modbus to DCIM), valve linkage (auto-close AC inlet valve on leak), and liquid type (water rope vs oil rope). Note: don’t lay rope where water already stands (false alarm); lay it on “likely leak” paths — under AC condensate trays, below chilled-pipe joints, around floor drains.
2. Key Features
Positioning detection
- Accuracy ±1 m.
- Reports leak distance in meters.
- Modbus upload.
- Fast pinpoint.
20 m rope
- Standard 20 m/roll.
- Extendable to 100 m.
- 6 mm diameter.
- Acid/alkali resistant, bendable.
Multi-liquid
- Clean water / condensate.
- Oil rope option.
- Dry-insulating, conducts on water.
- No false alarm when dry.
Linkage control
- Controller with relays.
- Sounder linkage.
- Can close AC water valve.
- RS485 to DCIM.
3. Specifications
| Item | KTR-WL4 |
|---|---|
| Model | KTR-WL4 |
| Detection | Positioning (4-wire sensing) |
| Rope length | 20 m (extendable 100 m) |
| Locating accuracy | ±1 m |
| Rope diameter | Approx 6 mm |
| Detected liquid | Clean water / condensate (conductive) |
| Communication | RS485 Modbus RTU |
| Relay output | 2× on controller |
| Operating temp. | -10~+60℃ |
| Controller power | DC12V/24V |
| Mounting | Under floor / surface |
| Material | Acid/alkali-resistant polymer |
4. Reference Prices
KTR-WL4 positioning leak rope 20 m (rope only, no controller): Reference USD 39~63 / roll (ref. CNY 280~450 at ~7.2)
KTR-WL4C locating controller (20 m rope + controller + RS485): Reference USD 111~208 / set (ref. CNY 800~1500 at ~7.2)
Reference only; tiered per meter. AC water-valve linkage not included. Volume discount above 3 sets. Oil-detection rope version on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Precision AC condensate tray leak monitoring.
- Chilled water / plumbing pipe routes.
- Raised-floor cable zone.
- Floor drains, door water-barriers.
- Battery room electrolyte leak monitoring.
6. Installation & Maintenance
Installation
- Lay rope under AC condensate trays, pipe joints, drains.
- Clip every 0.5 m; rope flush to floor.
- Connect rope to locating controller input.
- Wire RS485 to DCIM; set address.
- Simulate leak with a cup of water; verify locating distance.
Maintenance
- Quarterly clean rope (dust no effect; oil insulates and false-alarms).
- Annual water-spray test to verify locating.
- Check rope for rodent or crush damage.
- Verify controller relay action.
- Dry-environment rope life about 5~8 years.
7. FAQ
- Q: How much better is locating vs non-locating?
A: Non-locating only says water is on the rope; a 20 m rope in a big hall means lifting tiles section by section. Locating reports distance directly — find the leak in 5 minutes. Worth it in large halls. - Q: Can it detect oil leaks?
A: No, water rope doesn’t sense oil (oil is non-conductive). Use a dedicated oil rope — don’t mix. - Q: Can the rope be cut and extended?
A: Yes, with matching connectors; total length ≤100 m; seal splices. - Q: How to handle false alarms?
A: Usually oil on the rope or standing water. Clean the rope, drain water; reset when dry.
8. Trend & Selection
Leak detection evolves from “non-locating rope + alarm” toward “locating + auto-valve-shutoff + platform visualization.” Trends: accuracy improving from 2 m to 0.5 m, ropes with combined temperature/humidity, AC linkage (leak auto-closes inlet valve, starts backup AC), and platform GIS showing leak position. Selection: large halls must use locating type; lay along AC and pipes; RS485 to DCIM; link the water valve; annual water test; keep rope away from oil. Leak detection is the hall’s waterproof sentry — silent normally, but alarms before water reaches a rack; placed right, one saved incident pays for the system.
9. Delivery & Service
KITOZER provides leak detection selection: by hall area, AC count, and pipe routing, we configure rope length, controller channels, and linkage. Bundled with DCIM, sounder, and AC water valve. Delivery includes leak rope, locating controller, mounting clips, and manual. Warranty covers locating calibration and platform integration.
10. Additional Notes
The most common fault: “rope laid in the floor center.” Leak rope must run along “likely leak paths” — directly under AC condensate trays, below chilled-pipe joints, around drains. Laid in the floor center (no pipes), it never detects a leak; water reaches a rack before anyone notices — too late.
Another pitfall: “no water-spray test.” Installed and forgotten, then a real leak reveals a broken rope or wrong controller address. Run an annual spray test: pour water on the rope, verify platform alarm and reported distance.
Selection summary: locating 20 m; lay along AC and pipes; RS485 to DCIM; link the water valve; annual spray test; keep away from oil. Leak rope is a “small cost against big disaster” — a few-hundred-yuan rope prevents a flood that would cost hundreds of thousands in flooded racks.