KITOZER
KITOZER

KITOZER KTR-OS21 Precision Oil Separator (Dual-Inlet Cyclonic)

KITOZER KTR-OS21 Precision Oil Separator (Dual-Inlet Cyclonic)

Brand: KITOZER Series: KTR-OS21 Category: Data Center Engineering 2 / Air-Source Treatment

oil separatorcyclonicdual inletcompressed airair purification

1. Overview

KITOZER KTR-OS21 is a precision oil separator designed for data center compressed-air mains and nitrogen-generator gas trains. Data halls host many air-driven devices: pneumatic butterfly valves, gas-tight test couplings, cylinder purging, gas-suppression actuation sources and precision lab instruments. These demand extremely low oil content — oil mist reaching a valve or instrument causes seal swelling, valve stiction and measurement drift. Even after downstream filtration, screw-compressor air still carries trace oil mist and vapor; KTR-OS21 adds a final cyclonic-and-impingement separation stage at the main header, trapping free oil and water droplets before end-use points.

KTR-OS21 uses a dual tangential inlet: oily compressed air enters symmetrically at 15~25 m/s, forming a high-speed vortex inside the vessel. Centrifugal force flings heavier oil and water droplets to the wall, where they slide down into a bottom sump, while clean gas rises through the central outlet pipe. This cyclonic design reaches ≥99% removal for droplets above 3 µm, far better than ordinary filter-type oil removers — and it does not clog or need frequent element changes. The bottom sump has an auto drain/oil-bleed valve that discharges at a set level, plus a manual bypass.

Distinction from dryers: refrigerated dryers handle “temperature/dew point”, desiccant dryers handle “deep moisture drying”, and oil separators handle “mechanical removal of oil mist and liquid droplets”. They are used in series: compressor → air receiver → refrigerated dryer → KTR-OS21 → main-line filter → end point. KTR-OS21 emphasizes dual-inlet symmetry: a single inlet causes flow bias at high flow and drops efficiency; symmetric dual inlets keep the vortex stable across flow variations.

2. Key Features

Dual-inlet cyclone

  • Symmetric tangential inlets, stable vortex, low bias.
  • ≥99% removal for ≥3 µm droplets, pressure drop only 0.01~0.02 MPa.
  • No filter element, no consumables, no clogging-induced pressure rise.

Vessel & materials

  • Carbon-steel powder-coated or 304 stainless, internally corrosion-protected.
  • Flanged or threaded ports DN15~DN50.
  • Top sight glass for visual vortex inspection.

Auto oil/water drain

  • Bottom float-type or electronic level auto drain.
  • Manual drain bypass for maintenance.
  • Drain port connects to a waste-oil bottle to avoid floor contamination.

Monitoring

  • Inlet/outlet pressure gauges (differential gauge optional).
  • Differential pressure switch with relay output to DCIM.
  • Optional online oil-mist concentration probe.

3. Specifications

Item KTR-OS21-10 KTR-OS21-25 KTR-OS21-60
Flow capacity 1.0 m³/min 2.5 m³/min 6.0 m³/min
Port size DN15 / G1/2″ DN25 / G1″ DN40 / G1½”
Working pressure 0.7~1.0 MPa 0.7~1.0 MPa 0.7~1.3 MPa
Inlet temp ≤60℃ ≤60℃ ≤65℃
Efficiency (≥3µm) ≥99% ≥99% ≥99%
Pressure drop ≤0.015 MPa ≤0.02 MPa ≤0.025 MPa
Drain type Manual Auto float Electronic level + auto
Vessel material Carbon steel coated Carbon steel coated 304 stainless
Monitoring Pressure gauge DP gauge DP switch + DCIM

4. Reference Prices

KTR-OS21-10 small dual-inlet cyclone (manual drain, pressure gauge, coated carbon steel): Reference USD 167~361 / unit (ref. CNY 1,200~2,600 at ~7.2)

KTR-OS21-25/60 standard/high-flow (auto float/electronic drain, DP gauge or switch, 304 stainless optional): Reference USD 417~1,181 / unit (ref. CNY 3,000~8,500 at ~7.2)

Reference only; final quote depends on flow, port size, vessel material, drain type and monitoring. Compressor, dryer and piping installation excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center compressed-air mains final oil-mist separation.
  • Nitrogen generator / PSA front-end gas train oil removal.
  • Gas-suppression actuation cylinder air lines oil removal.
  • Lab precision instruments and pneumatic control valves.
  • Industrial painting and purge process air.

6. Installation & Maintenance

Installation

  • Mount vertically upright (cyclone needs gravity separation).
  • Install isolation valves at inlet/outlet for online maintenance.
  • Fit a Y-strainer upstream to protect the separator.
  • Connect drain to a transparent collection bottle or return line.
  • Install inlet/outlet pressure or DP gauges.
  • Wire DP switch to DCIM monitoring.

Maintenance

  • Check gauges daily for rising pressure drop.
  • Empty bottom oil bottle regularly (1~3 months by usage).
  • Verify auto drain valve action.
  • Annually inspect vessel wall through sight glass for corrosion and sludge.
  • Clean internal separation elements (no element replacement).

7. FAQ

  • Q: With a main-line fine filter, do I still need an oil separator?
    A: Yes. Filter-type oil removers saturate and clog under high oil load; the cyclone pre-removes most liquid droplets mechanically, greatly extending downstream element life.
  • Q: How clean can cyclone separation get oil?
    A: It targets ≥3 µm free liquid droplets at ≥99%; vapor oil mist and sub-3 µm aerosols still require activated carbon or catalytic oil removal.
  • Q: Why dual inlet? Isn’t one enough?
    A: A single inlet works at rated flow but biases the vortex at high flow, dropping efficiency; symmetric dual inlets keep the flow field uniform across flow swings.
  • Q: Why must the vessel be vertical?
    A: Centrifugal force throws droplets to the wall, then gravity carries them down to the sump; horizontal mounting makes sump layout hard and causes re-entrainment.

8. Trend & Selection

Data center air systems evolve from “dew-point only” to “integrated oil/water/dust purification”: as pneumatic components get more precise and gas-suppression systems demand strict air quality, oil-mist control moves from optional to mandatory. The trend is a three-stage train — cyclone + fine filter + activated carbon — linked to DCIM for DP alarms. Select flow with 20~30% margin; use dual-inlet cyclone on mains; match port size to the header (no step-down); choose coated carbon steel normally, 304 stainless for humid/food-grade environments; pick auto float or electronic drain; DP gauge/switch is mandatory for wash-cycle judgment.

9. Delivery & Service

KITOZER provides selection: based on data hall air demand, number of end points and air-quality requirements, we size the flow and configure the dual-inlet cyclone, drain valve, pressure/DP gauge and monitoring signals. We produce the gas-train drawing (compressor → receiver → dryer → oil separator → main filter → end points). Bundled with screw compressors, refrigerated/desiccant dryers and main-line filters. Delivery includes vessel, flanges, drain valve, gauges and mounting bracket. Warranty covers DP-alarm commissioning.

10. Additional Notes

The most common pitfall is “horizontal mounting”. Contractors lay the vessel horizontally on a duct bracket for convenience — the vortex becomes horizontal, droplets flung to the wall cannot slide down by gravity, and are re-entrained by the gas stream, gutting efficiency. Oil separators must be vertical, drain at the very bottom.

Another pitfall: “drain piped straight to floor drain”. The sump holds oily condensate; direct discharge clogs drains and causes environmental issues. Correct practice is to route first to a waste-oil collection bottle, emptied manually, or into a centralized oily-waste treatment.

Selection summary: size flow with margin; vertical dual-inlet cyclone; port matched to header; auto drain + waste collection; DP monitoring to DCIM; upstream Y-strainer. The oil separator is the precision gatekeeper of the data hall air source — it stops liquid oil and water at the header so downstream valves and instruments run reliably for years.

Scroll to Top