KITOZER KTR-LCOM9 LC Duplex OM3 Multimode Fiber Adapter

KITOZER KTR-LCOM9 LC Duplex OM3 Multimode Fiber Adapter

Brand: KITOZER Series: KTR-LCOM9 Category: Data Center Engineering / Low-Voltage Cabling

LC duplexOM3 multimodefiber adaptercoupler10G multimode

[Product image: KITOZER KTR-LCOM9 LC duplex OM3 fiber adapter, purple flange]

1. Overview

KITOZER KTR-LCOM9 is an LC duplex OM3 multimode fiber adapter, the basic yet critical passive connector in data center low-voltage cabling. It mounts on a fiber distribution frame (ODF) or terminal box panel: one side receives equipment-side LC-LC patch cords, the other receives pigtails spliced to backbone cable, enabling an active optical connection. Though each adapter is inexpensive, a mid-size data hall uses hundreds in parallel — insertion loss, return loss and mating-cycle life directly determine end-to-end 10G multimode link quality. KTR-LCOM9 is purpose-built for OM3 10G multimode links, with a 2.0 mm duplex LC one-piece flange and precision ceramic sleeve for stable 10 Gbps transmission.

OM3 multimode uses laser-optimized 50/125 µm core, aqua jacket, supporting 10Gbps up to 300 m — the mainstream choice for building-to-rack and rack-to-server short-reach links. KTR-LCOM9 uses a high-precision zirconia ceramic sleeve (1.25 mm bore) matched to LC ferrules with concentricity ≤0.5 µm. The one-piece duplex flange holds RX and TX LC ports side by side to prevent mis-pairing. The housing is flame-retardant PC (UL94 V-0) with snap-in mounting on standard 19-inch panel holes.

Compared with SC, LC is half the size — a 1U panel holds 24 LC duplexes (48 fibers) versus only 12 SC duplexes (24 fibers). In U-space-constrained data centers, LC is the de facto 10G standard. KTR-LCOM9’s purple housing (the OM3 color code) lets technicians instantly identify OM3 links, avoiding confusion with OM4 aqua or single-mode blue.

2. Key Features

Low-loss precision alignment

  • Zirconia ceramic sleeve, concentricity ≤0.5 µm.
  • Insertion loss ≤0.2 dB (typical 0.15 dB).
  • Return loss ≥30 dB (PC polish).

OM3 10G compatibility

  • Supports 10GBASE-SR multimode.
  • Designed for 50/125 µm OM3 fiber.
  • Purple housing codes OM3 to prevent mismatch.

High-density duplex

  • One-piece LC duplex flange, RX/TX side by side.
  • 1U panel fits 24 duplexes (48 fibers).
  • Snap-in mounting, tool-less removal.

Durability & environment

  • Mating cycles ≥500.
  • Flame-retardant PC housing, UL94 V-0.
  • Operating temp -40~75℃.

3. Specifications

Item Value
Adapter type LC duplex
Fiber type OM3 50/125 µm multimode
Sleeve material Zirconia ceramic
End-face polish PC
Insertion loss ≤0.2 dB (typ 0.15 dB)
Return loss ≥30 dB
Mating cycles ≥500
Operating temp -40~75℃
Flame rating UL94 V-0
Mounting Snap-in, standard panel cutout
Housing color Purple (OM3 code)

4. Reference Prices

KTR-LCOM9 standard LC duplex OM3 (ceramic sleeve, PC, purple, snap-in): Reference USD 0.4~1.1 / pc (ref. CNY 3~8 at ~7.2)

KTR-LCOM9 bulk (100+, pre-loaded on patch panel): Reference USD 0.35~0.85 / pc (ref. CNY 2.5~6 at ~7.2)

Reference only; pricing by quantity, panel pre-assembly, polish grade. Patch cords and pigtails excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • 19-inch ODF panel coupling in data halls.
  • Access-switch-to-server 10G short-reach links.
  • Building vertical backbone OM3 termination.
  • Low-voltage room terminal boxes and wall-mount enclosures.
  • Industrial fiber sensor networks.

6. Installation & Maintenance

Installation

  • Confirm panel cutout size; snap adapter in until locked.
  • Observe orientation tab; do not force reversed.
  • Insert spliced pigtail at rear, patch cord at front.
  • Listen for click on both sides.
  • Test link loss with power meter.
  • Label port number.

Maintenance

  • Keep dust caps on unused ports.
  • Clean end faces with fiber pen before each mating.
  • Annually test link loss with VFL/OTDR sample.
  • Replace adapter if ceramic sleeve loosens.
  • Replace after 500 mating cycles.

7. FAQ

  • Q: Can I mix OM3 and OM4 adapters?
    A: Physically compatible but color-coded differently (OM3 purple, OM4 aqua); mixing causes operational confusion. Match adapter color to link grade.
  • Q: Can LC and SC intermate?
    A: No. Use LC-SC hybrid adapter or hybrid cord. Standardize connector type at design stage.
  • Q: Does 0.2 dB matter for 10G?
    A: 10G OM3 link budget is ~2.6 dB; one adapter at 0.2 dB is within budget, but cascading through 2~3 patch panels can exceed it — calculate total budget at design.
  • Q: Ceramic vs bronze sleeve?
    A: Choose ceramic for permanent data center use (wear-stable loss); bronze only for temporary testing.

8. Trend & Selection

Data centers evolve from 10G to 25G/40G/100G, multimode from OM3 to OM4/OM5, but OM3 remains a large installed base. LC has displaced SC for density. The trend is MPO/MTP pre-terminated trunk + LC harness architecture. Select: purple LC duplex for OM3; ceramic sleeve standard; PC for 10G (APC for video/low-reflection); verify orientation when pre-assembled; sample-test insertion loss in bulk.

9. Delivery & Service

KITOZER supplies adapters in volume: based on panel count and port density, we configure LC duplex OM3 adapters, and can deliver pre-loaded on 1U/2U ODF frames (including pigtail splicing and labeling). Delivery includes adapters, dust caps and mounting clips. Warranty covers loss retesting and defective replacement.

10. Additional Notes

The cheapest component is also the most neglected. Field issue: “no dust caps” — dust entering the ceramic sleeve scratches the end face on mating, pushing loss from 0.15 dB to 0.5 dB+ and causing 10G packet loss. Dust caps on unused ports are basic discipline.

Another pitfall: “mating dirty end faces.” Technicians plug cords straight from the bag; dust crushes into scratches inside the sleeve. Clean every end face with a fiber pen or lint-free alcohol swab before mating.

Selection summary: purple LC duplex for OM3; ceramic PC; snap-in high-density; dust caps mandatory; clean end faces; sample-test in bulk. The adapter is the optical socket — without a solid socket, even strong 10G signals never reach the server.