Table of Contents
ToggleKITOZER KTR-WC8 Locating Water Leak Controller (16 Zones)
Brand: KITOZER Series: KTR-WC8 Category: Environmental Monitoring / Leak Detection
leak controllerlocating leak16 zonesleak ropeenvironment monitorKTR-WC8
1. Overview
KITOZER KTR-WC8 is a locating water leak controller — the core host in data-center environmental monitoring for detecting AC condensate, pipe leaks and underfloor water. Unlike non-locating alarms that only say “leak yes/no,” KTR-WC8 reports not only which zone but also the exact distance along the sensing cable — staff walk straight to the spot instead of tracing every meter.
The host is a 1U rack unit with an LCD and keypad. It accepts up to 16 locating sensing cables (each up to 100~250 m), one per zone. Each cable braids two sense conductors with a water-permeable spacer: dry, the wires are insulated; when water bridges them, the controller measures resistance from the host to the short and converts it to distance, accurate to ±1 m.
Alarm outputs: per-zone relay dry contacts (alarm/fault), plus RS485 (Modbus RTU) and Ethernet (TCP/IP) to the DCIM platform. The LCD shows live zone status and leak distance. Power: DC12 V or 220 V options. Locating cables are reusable — once wiped dry the alarm clears; a cut cable triggers a break fault. Sensing cable, clips and end-of-line resistor are included.
2. Key Features
16-zone locating
- Up to 16 sensing cables.
- Precise leak ±1 m.
- Up to 250 m per cable.
Multi-interface output
- Per-zone relay contacts.
- RS485 Modbus RTU.
- Ethernet TCP/IP.
1U rack mount
- 19-inch 1U.
- LCD live display.
- Keypad operation.
Reusable cable
- Clears when dry.
- Break-fault detection.
- End-of-line resistor.
3. Specifications
| Item | KTR-WC8 |
|---|---|
| Zones | 16 independent inputs |
| Location accuracy | ±1 m |
| Cable length | 100~250 m per zone |
| Alarm output | 2 relay contacts per zone |
| Communication | RS485 Modbus RTU + Ethernet TCP/IP |
| Display | LCD |
| Power | DC12V / AC220V optional |
| Mount | 19-inch 1U rack |
| Sensing cable | Locating 4-wire rope |
| Fault detect | Open / short alarm |
| Operating temp | 0~50°C |
4. Reference Prices
KTR-WC8 16-zone locating controller (LCD, 1U): Reference USD 389~625 / unit (ref. CNY 2,800~4,500 at ~7.2)
KTR-WC8 locating sensing cable (per meter, with EOL): Reference USD 4.9~8.3 / m (ref. CNY 35~60 at ~7.2)
Reference only; controller per unit, cable per meter. Installation not included. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Condensate leaks under precision AC.
- Underfloor water pipe and sprinkler lines.
- Power and battery rooms.
- Archives and libraries near AC.
- Cleanrooms and labs.
6. Installation & Maintenance
Installation
- Rack-mount controller in monitoring cabinet.
- Run rope under AC and along pipes.
- Clip every 0.5 m.
- Fit end-of-line resistor at rope end.
- Start end to the matching zone port.
- Wire relays to siren/beacon.
- Connect RS485/Ethernet to DCIM.
- Wet-test to verify location accuracy.
Maintenance
- Inspect rope quarterly for damage.
- Check EOL resistor yearly.
- Self-test controller annually.
- Dry the rope after each event.
- Wipe dirty rope with a damp cloth.
7. FAQ
- Q: Locating vs non-locating?
A: Non-locating only says “zone X leaks”; you trace the whole rope. Locating says “X meters from host” — minutes instead of half an hour. - Q: Can the rope bend?
A: Yes, but keep bend radius ≥30 mm; no sharp kinks. Run it in floor tray. - Q: Does the alarm clear after drying?
A: Yes — locating ropes self-clear when dry and are reusable. - Q: Max length per zone?
A: 100~250 m depending on model. Split into more zones beyond that.
8. Trend & Selection
DCIM moves from “alarm seen by someone” to “precise location auto-dispatched.” The 16-zone locating controller upgrades leak detection from vague alarm to exact distance, paired with SMS/APP push and ticketing. Zone by AC and pipe routing; ±1 m accuracy; relay + RS485 dual output; run rope along risk points. Water is the data center’s flood — finding it one minute earlier saves six figures.
9. Delivery & Service
KITOZER supplies KTR-WC8 controller and sensing cable sized to the room and AC/pipe layout, with clips, EOL resistors and relay terminals. We provide the DCIM protocol and zone map. Warranty covers controller and cable replacement.
10. Additional Notes
A common mistake: looping the rope only around the AC unit. Leaks happen not just under the unit — condensate joints, clogged drains and pipe welds all leak. Run the rope under every joint, the AC drain pan and along underfloor piping; a single loop is not coverage.
Another pitfall: no end-of-line resistor. Locating cables need an EOL resistor (typically 100 Ω or as specified) at the far end; without it the controller can’t compute distance and locating fails. Check every rope end at install.
Selection summary: 16-zone locating; ±1 m; run along risk points; EOL resistor on every rope; relay + RS485 output. The leak controller is the room’s water sentry — accurate location means earlier containment.