Manufacturer: Guangdong Lain Intelligent Machine Room Equipment Co., Ltd. (KITOZER Brand)
Document Version: V2.0
Release Date: July 2026
Applicable Standards: GA 1051-2013 “Special Security Cabinets for Firearms and Ammunition”, GB/T 28181-2022 “Information Transmission, Exchange, and Control Technical Requirements for Public Security Video Surveillance Networking Systems”, GA 1016-2012 “Risk Level Classification and Security Prevention Requirements for Firearm (Ammunition) Storage Rooms”
Table of Contents
TogglePreface

This manual provides a comprehensive explanation of the technical principles, structural composition, installation specifications, wiring standards, commissioning procedures, maintenance requirements, troubleshooting, and acceptance criteria for the intelligent firearm (ammunition) management cabinet series manufactured by Guangdong Lain Intelligent Machine Room Equipment Co., Ltd. It is designed to provide equipment user units, installation and construction personnel, and operation and maintenance management personnel with complete, standardized, and actionable operational guidance.
The intelligent firearm (ammunition) management cabinet is a confidential storage device integrating high-strength physical protection, multimodal biometric identification, IoT real-time monitoring, and digital ledger management. It strictly complies with public security industry standards and military security specifications, and is suitable for the standardized management of firearms by public security agencies, military forces, armed police, escort units, shooting venues, and other firearm-related units. Through a “physical defense + technical defense + personnel defense” trinity security architecture, this device achieves closed-loop process control throughout the entire cycle of firearm issue, return, inventory, and traceability, eliminating security risks such as firearm loss, theft, and unauthorized use from a technical perspective.
This manual is compiled based on the latest technical solution of the product. If technical parameters or functional configurations change due to product upgrades, the manufacturer will update the manual content accordingly without prior notice. Installation, wiring, commissioning, and maintenance of the equipment must be performed by professionally trained technical personnel. Improper operation may result in equipment damage, functional failure, or even safety incidents.
Table of Contents

Product Introduction
Product Composition
Product List
Product Working Principles
Product Technical Parameters
Product Functions and Features
Product Application Scenarios
Product Installation Specifications and Procedures
Product Wiring Standards and Operations
Product Commissioning Procedures and Verification Methods
Product Usage Precautions
Product Repair and Maintenance Specifications
Product Common Problems and Solutions
Product QA FAQ Manual
Product Acceptance Standards and Procedures
SEO Keyword Optimization System
Contact Information and Copyright Notice
1 Product Introduction

1.1 Product Definition
The intelligent firearm (ammunition) management cabinet is a specialized security equipment designed for the safe storage and intelligent control of firearms, ammunition, and associated accessories. It falls within the category of state-regulated confidential storage equipment. Unlike traditional safes, this product not only possesses high-strength physical anti-destruction capability but also integrates intelligent functions such as identity authentication, status monitoring, automatic alarm, data traceability, and networked management, making it the core hardware carrier of modern firearm security management systems.
The intelligent firearm (ammunition) management cabinet manufactured by Guangdong Lain Intelligent Machine Room Equipment Co., Ltd. adopts a modular design concept, allowing flexible configuration of long-barrel firearm positions, short-barrel firearm positions, ammunition drawers, and accessory shelves according to user storage requirements. It supports both single-cabinet independent operation and multi-cabinet cascade networking modes, accommodating management needs ranging from grassroots police stations to municipal-level armories. The entire product series has passed inspection by the Quality Supervision and Inspection Center for Special Police Equipment of the Ministry of Public Security, fully complies with GA 1051-2013 industry standard requirements, and possesses complete compliance certification documentation.
1.2 Research and Development Background
For a long time, firearm management in China’s firearm-related units has primarily relied on the traditional model of “manual registration + mechanical locks”, which suffers from pain points such as low management efficiency, difficult responsibility traceability, difficulty preventing unauthorized operations, and large inventory discrepancies. In recent years, as social security control requirements have continued to escalate, the standardization, intelligentization, and digitization of firearm management have become an inevitable trend. The state has successively issued multiple standards and specifications, explicitly requiring firearm storage equipment to possess functions such as electronic control, identity verification, abnormal alarm, and record retention.
Against this background, Guangdong Lain Intelligent Machine Room Equipment Co., Ltd., leveraging its technical accumulation in the fields of security storage, intelligent control, and system integration, combined with the actual management processes of public security, military, and other units, has developed a new generation of intelligent firearm (ammunition) management cabinets. The product deeply aligns with domestic firearm management regulatory requirements, deeply integrating physical security protection with information-based management technology, effectively resolving security vulnerabilities and efficiency bottlenecks under traditional management models, and assisting firearm-related units in achieving standardized, visualized, and traceable firearm management.
1.3 Design Philosophy
This product adheres to the core design philosophy of “Safety First, Compliance Foremost, Intelligent Control, Easy and Reliable Use”, comprehensively covering all scenario requirements of firearm storage and management:
- Safety First: Based on physical protection, centered on electronic control, and safeguarded by multi-factor verification, constructing a defense-in-depth system to ensure the absolute safety of firearms;
- Compliance Foremost: Strictly aligning with current national and industry standards, all functional designs and performance indicators meet regulatory requirements, ensuring users pass acceptance and routine inspections smoothly;
- Intelligent Control: Leveraging IoT, biometric identification, RFID radio frequency identification, and other technologies to achieve automatic perception of firearm status, intelligent validation of operational processes, and automatic generation of management data, reducing human intervention;
- Easy and Reliable: Optimizing human-machine interaction experience, simplifying operational procedures, lowering the usage threshold; simultaneously adopting industrial-grade hardware configuration to ensure 7×24-hour stable operation of the equipment and adaptability to complex environments.
1.4 Applicable Standards
The design, production, testing, installation, and acceptance of this product strictly comply with the following national and industry standards:
- GA 1051-2013 “Special Security Cabinets for Firearms and Ammunition”
- GA 1016-2012 “Risk Level Classification and Security Prevention Requirements for Firearm (Ammunition) Storage Rooms”
- GB/T 28181-2022 “Information Transmission, Exchange, and Control Technical Requirements for Public Security Video Surveillance Networking Systems”
- GB 35114-2017 “Information Security Technical Requirements for Public Security Video Surveillance Networking Systems”
- GB 17565-2022 “General Technical Conditions for Anti-theft Security Doors”
- GB/T 7633-2008 “Fire Resistance Test Methods for Doors and Shutters”
- GJB 2805B-2021 “Technical Requirements for Ordnance Warehouse Security Systems” (military customized version)
- GB 50057-2010 “Code for Design of Protection of Structures Against Lightning”
- GB 50198-2011 “Code for Engineering of Civil Closed-Circuit Surveillance Television Systems”
1.5 Product Positioning
This product is positioned as a mid-to-high-end professional-grade intelligent firearm control device, primarily targeting government, enterprise, and military organizations with high-level firearm security requirements. It can serve as an independent firearm storage unit or be integrated into an overall control platform as a subsystem of the armory security system. The product covers the full capacity range from small cabinets with fewer than 10 positions to large combined cabinets with over 100 positions, meeting the usage requirements of units at different levels, including grassroots stations, sub-bureaus, municipal bureaus, military barracks, and escort bases.
1.6 Core Values
1.6.1 Safety Value
Through high-strength cabinet structure, multi-factor identity authentication, real-time status monitoring, and multi-level alarm mechanisms, a comprehensive security protection system is constructed, eliminating the risks of firearm theft, loss, and unauthorized use from both physical and technical levels, thereby safeguarding public security.
1.6.2 Management Value
Achieves full-process digital management of firearm issue, return, inventory, maintenance, and scrapping, automatically generating electronic ledgers and operational logs, reducing manual registration workload, avoiding human errors, and improving management efficiency and standardization levels.
1.6.3 Traceability Value
All operations are fully recorded, capturing multi-dimensional information including operator identity, operation time, operation content, firearm serial numbers, and scene imaging, forming an immutable traceability chain that satisfies audit and accountability determination requirements.
1.6.4 Compliance Value
The product fully complies with national and industry standards, possesses authoritative test reports, and helps users pass public security department firearm safety inspections and acceptance smoothly, mitigating compliance risks.
2 Product Composition
The intelligent firearm (ammunition) management cabinet consists of eight core component systems: cabinet mechanical structure system, intelligent electronic control system, identity authentication system, firearm status monitoring system, alarm linkage system, power supply guarantee system, network communication system, and internal storage components. All systems work in coordination to collectively achieve the secure storage and intelligent control of firearms.
2.1 Cabinet Mechanical Structure System
The cabinet mechanical structure is the physical protection foundation of the product. It adopts an all-steel welded integrated structure with multiple protection capabilities including anti-pry, anti-drill, anti-cutting, anti-impact, and fire-resistant properties.
2.1.1 Cabinet Body
- Material: High-quality carbon structural steel (Q345B). Cabinet side panels, back panel, top panel, and bottom panel have a steel plate thickness of ≥6mm. The cabinet door adopts a double-layer steel plate structure with an outer layer thickness of ≥10mm and an inner layer thickness of ≥3mm, filled with fire-resistant flame-retardant material and anti-drill reinforced steel plates in between;
- Process: CNC laser cutting for blanking, CNC bending for forming, and argon arc welding for seamless welding. The overall weld strength is high, and the structural rigidity is strong. Cabinet diagonal error ≤4mm, external dimension deviation ≤±2mm;
- Surface Treatment: Multiple processes of acid washing, phosphating, and electrostatic powder coating. The coating thickness is ≥60μm, providing excellent corrosion resistance, rust prevention, and wear resistance. The appearance is smooth and flat, free from burrs, scratches, bubbles, and other defects;
- Reinforcement Structure: Horizontal and vertical reinforcing ribs are set inside the cabinet to enhance impact resistance and deformation resistance. Fixing mounting holes are reserved at the bottom, allowing secure connection to the floor via expansion bolts to prevent the cabinet from being moved as a whole.
2.1.2 Cabinet Door Assembly
- Structural Type: Double-door design (large-capacity models) or single-door design (small-capacity models), equipped with concealed heavy-duty hinges. The hinge material is stainless steel, with ≥3 sets of hinges per door leaf, ensuring the door does not sag with long-term use;
- Opening Angle: Maximum door opening angle ≥90°, smooth opening without jamming, tight closure when closed, door gap ≤0.2mm;
- Bolt Mechanism: Equipped with multi-point linked door bolts, with a total of ≥5 movable bolts on each door leaf at the top, bottom, and sides. Bolt diameter ≥25mm, effective extension length ≥25mm. The bolt material is high-strength alloy steel, resistant to sawing and prying;
- Sealing Structure: Fire-resistant sealing strips are installed around the cabinet door, providing fireproof, dustproof, and moisture-proof sealing effects. Under high-temperature conditions, the sealing strips expand to fill gaps, blocking smoke and heat from entering the cabinet;
- Door Handle: Chrome-plated high-strength alloy handle with anti-forced-torsion structure, torque resistance ≥500N·m, smooth handle rotation and comfortable tactile feel.
2.1.3 Bottom Support and Moving Mechanism
- Load-Bearing Feet: Equipped with 4 adjustable heavy-duty feet made of rubber + carbon steel, with a single foot load capacity of ≥200kg. Cabinet leveling can be adjusted by rotating, with an adjustment range of ±15mm;
- Moving Casters: Some models are equipped with concealed heavy-duty universal casters with brake devices, facilitating equipment installation positioning and position adjustment. During normal use, the casters are retracted, and the equipment is supported by the feet;
- Bottom Protection: The bottom steel plate is thickened, with grounding terminals and cable through-holes reserved. The cable through-holes are equipped with rubber protective grommets to prevent cable abrasion.
2.2 Intelligent Electronic Control System
The intelligent electronic control system is the “brain” of the product, responsible for the logical control, data processing, command execution, and human-machine interaction of the entire device. It consists of three parts: the main control unit, the human-machine interaction terminal, and the storage unit.
2.2.1 Main Control Unit
- Core Processor: Industrial-grade embedded ARM quad-core processor, main frequency ≥1.5GHz, with powerful data processing capability and multi-task concurrent processing capability;
- Mainboard Configuration: Industrial-grade control mainboard with embedded Linux operating system. The system is stable and reliable, with strong anti-virus and anti-attack capabilities, supporting 7×24-hour uninterrupted operation;
- Interface Resources: Integrated multiple RS485 interfaces, GPIO interfaces, relay output interfaces, network interfaces, and USB interfaces, capable of connecting various sensors, locks, and peripheral devices;
- Storage Module: Equipped with ≥8GB solid-state storage chip for storing system programs, operation logs, user information, captured images, and other data, supporting automatic data backup and export;
- Real-Time Clock: Built-in high-precision RTC clock chip with coin cell battery power supply. The clock continues to operate normally after power failure, ensuring accurate operation log timestamps.
2.2.2 Human-Machine Interaction Terminal
- Display Screen: ≥10.1-inch industrial-grade capacitive touch screen, resolution ≥1280×800, supporting multi-touch, clear display, responsive touch sensitivity, adaptable to -10°C to 60°C operating temperature;
- Operation Interface: Graphical Chinese operation interface with clear functional zoning and concise operation logic, featuring core function entries for issue, return, query, settings, and alarm, usable without extensive training;
- Voice Prompt: Built-in high-fidelity voice module with full-process Chinese voice guidance during operations and voice alarms for abnormal states, enhancing operational convenience and warning effectiveness;
- Status Indicator Lights: Equipped with four-color status indicator lights for power, operation, network, and alarm, visually displaying the current operating status of the equipment.
2.2.3 Storage Unit
- Industrial-grade eMMC storage media with fast read/write speed, shock and vibration resistance, and long service life;
- Supports storage of ≥100,000 operation log entries, ≥5,000 captured images, and ≥10,000 user information records;
- Supports data circular overwrite — when storage space is insufficient, the earliest non-critical data is automatically overwritten to ensure continuous system operation;
- Supports USB interface data export — logs, images, and other data can be exported to a USB flash drive for backup and archiving.
2.3 Identity Authentication System
The identity authentication system is the access control gateway for firearm retrieval, adopting a “multi-factor verification + dual-person dual-lock” control mechanism to ensure that only authorized personnel, following prescribed procedures, can open the cabinet door and retrieve firearms.
2.3.1 Fingerprint Recognition Module
- Sensor Type: Semiconductor capacitive fingerprint sensor, sensing area ≥10mm×10mm, with liveness detection capability to effectively identify fake fingerprints and silicone fingerprints;
- Performance Parameters: Fingerprint storage capacity ≥10,000 prints, False Acceptance Rate (FAR) ≤0.001%, False Rejection Rate (FRR) ≤1%, recognition response time ≤1s;
- Recognition Method: Supports 360° arbitrary angle recognition, with good adaptability to dry/wet fingers, slight wear, peeling skin, and other conditions;
- Security Level: Complies with GA/T 1011-2012 “General Technical Requirements for Citizen ID Card Fingerprint Collectors”.
2.3.2 Facial Recognition Module
- Camera Configuration: Dual-lens infrared + visible light dual camera, pixel ≥2 million, with liveness detection capability to resist photo, video, mask, and other spoofing attacks;
- Performance Parameters: Facial storage capacity ≥5,000 faces, recognition accuracy ≥99.5%, recognition distance 40cm~120cm, adaptable to heights of 1.2m~2.0m, recognition response time ≤1.2s;
- Environmental Adaptability: Supports normal recognition under backlight, low-light, and dark-light conditions. Built-in infrared fill light enables accurate recognition even in no-light nighttime environments;
- Function Expansion: Supports facial capture — automatic capture of on-site facial images during door opening operations and alarm events, stored in the log system.
2.3.3 Password Authentication Module
- Supports 6~16 digit numeric password authentication, with multi-level password management permissions divided into administrator password, operator password, and emergency password;
- Has anti-brute-force cracking mechanism — 5 consecutive incorrect password entries automatically lock the account for 15 minutes and trigger an alarm;
- Supports periodic password change reminders. Password changes require verification of original identity to ensure password security.
2.3.4 IC Card Authentication Module
- Supports IC card reading compliant with ISO/IEC 14443 standard, card reading distance 0~5cm, card reading response time ≤0.3s;
- Supports reuse of existing cards such as police officer cards and work badges — no additional card production required;
- Card information is bound to personnel permissions. Lost cards can be immediately deregistered to prevent security risks from lost cards.
2.3.5 Alcohol Detection Module (Optional Configuration)
- Uses electrochemical alcohol sensor, detection range 0~5mg/L, detection accuracy ±0.01mg/L;
- Supports breath-type alcohol detection. Alcohol testing must be passed before firearm retrieval; exceeding the limit prohibits retrieval;
- Has anti-cheating design, capable of identifying genuine vs. fake breath to prevent proxy blowing, airbag cheating, and other fraudulent behaviors;
- Test results are automatically stored in operation logs for traceability inquiry.
2.3.6 Dual-Person Dual-Lock Control Mechanism
- The system supports “dual-person dual-lock” authentication mode. Opening the cabinet door requires two authorized personnel to complete identity verification in sequence — neither is dispensable;
- Verification time interval can be set. The interval between the two personnel’s verifications is ≤30s; exceeding the time requires re-verification;
- Supports multi-level approval processes. In emergency situations, an administrator can remotely authorize door opening, with all actions fully recorded.
2.4 Firearm Status Monitoring System
The firearm status monitoring system uses various sensors to perceive in real time the presence status, quantity information, and environmental parameters of firearms inside the cabinet, achieving visualized and dynamic control of firearm status.
2.4.1 Firearm Presence Detection Module
- Detection Method: RFID radio frequency identification technology. Each firearm is affixed with a dedicated anti-metal electronic tag, and each firearm position is equipped with an independent RFID reading antenna;
- Detection Accuracy: Can precisely identify the present/absent status of each firearm, recognition accuracy 100%, with no false alarms or missed reports;
- Detection Frequency: Real-time scanning detection, data refresh frequency ≤1s. The moment a firearm is removed, it is instantly sensed and recorded;
- Tag Performance: Electronic tags feature anti-metal design. Adhesion to the firearm surface does not affect usage. Read distance 0~10cm, service life ≥10 years.
2.4.2 Ammunition Counting Detection Module
- Ammunition Drawer Detection: Each ammunition drawer is equipped with an independent electronic lock and weight sensor, capable of precisely detecting ammunition weight and converting it to ammunition count, detection accuracy ±1 round;
- Counting Method: Supports both weight counting and photoelectric counting modes; the appropriate solution can be selected based on ammunition type;
- Abnormal Warning: Automatic alert when ammunition quantity falls below threshold; alarm triggers when quantity changes abnormally.
2.4.3 Environmental Monitoring Module
- Temperature and Humidity Sensor: High-precision temperature and humidity sensor inside the cabinet. Temperature measurement range -20°C~80°C, accuracy ±0.5°C; humidity measurement range 0~100%RH, accuracy ±3%RH;
- Monitoring Function: Real-time display of temperature and humidity values inside the cabinet. Temperature and humidity upper/lower threshold limits can be set. Automatic alarm triggers when exceeding thresholds, with linkage to dehumidification/heating devices;
- Data Recording: Automatically records historical temperature and humidity data, generates temperature/humidity variation curves, and supports query and export.
2.4.4 Door Magnetic Detection Module
- The cabinet door is equipped with a high-precision door magnetic sensor for real-time detection of door open/closed status;
- Abnormal door opening, incomplete closure, and prolonged opening all trigger corresponding prompts or alarms;
- The door magnetic sensor is installed in a concealed manner, making it difficult to detect and tamper with.
2.4.5 Vibration/Impact Detection Module
- The cabinet embeds a high-sensitivity vibration sensor capable of perceiving destructive behaviors such as forced prying, cutting, and impact;
- Sensitivity is adjustable in multiple levels; thresholds can be adjusted based on installation environment to avoid false alarms;
- Upon detection of abnormal vibration, an on-site audible and visual alarm is immediately triggered, and alarm information is uploaded to the management platform.
2.5 Alarm Linkage System
The alarm linkage system is the last line of defense in security protection, possessing multi-dimensional abnormal detection capability and multi-level linkage response mechanisms to ensure security incidents are detected and handled promptly.
2.5.1 Local Audible and Visual Alarm
- Configured with high-decibel audible and visual alarm device, alarm volume ≥110dB, alarm light is red strobe, with significant warning effect;
- Different types of alarms can be set with different alarm tones and light patterns to facilitate distinguishing alarm types;
- Alarm duration is settable, defaulting to 5 minutes of continuous sounding, or can be set to manual release.
2.5.2 Alarm Types
The system supports the following alarm types, covering the vast majority of security risk scenarios:
| Alarm Type | Description |
|---|---|
| Illegal Door Opening Alarm | Forcible door opening without passing normal identity verification |
| Violent Destruction Alarm | Detection of abnormal vibration, impact, cutting, and other destructive behaviors |
| Overdue Non-Return Alarm | Firearm issued exceeding the specified return time without being returned |
| Temperature/Humidity Exceeding Alarm | In-cabinet temperature/humidity exceeding set thresholds |
| Power Failure Alarm | Main power outage, backup battery low level |
| Network Disconnection Alarm | Disconnection of equipment from management platform network |
| Tamper Alarm | Illegal disassembly of equipment housing |
| Password Error Alarm | Consecutive multiple identity verification failures |
| Firearm Abnormal Alarm | Abnormal firearm quantity, unauthorized removal from position |
2.5.3 Alarm Linkage Functions
- Upon alarm trigger, automatically captures on-site images and records alarm time, alarm type, and on-site status;
- Automatically uploads alarm information to the backend management platform, while simultaneously pushing SMS/APP messages to administrators;
- Can link surrounding security equipment — for example, linking with video surveillance systems to retrieve on-site footage, or linking with alarm hosts to upload alerts to the 110 dispatch platform;
- Supports graded alarm handling — general alarms are locally indicated, severe alarms trigger multi-level linkage.
2.6 Power Supply Guarantee System
The power supply guarantee system provides stable and reliable power to the equipment, ensuring normal operation even during power outages to maintain uninterrupted control.
2.6.1 Main Power Module
- Input Specification: AC 220V±10%, 50Hz, standard utility power supply;
- Power Module: Industrial-grade switching power supply, output DC 12V/5A, with overvoltage, overcurrent, short-circuit, and overheat protection functions;
- Conversion Efficiency: Power conversion efficiency ≥85%, low energy consumption, minimal heat generation;
- Electromagnetic Compatibility: Complies with GB/T 17626 electromagnetic compatibility standards, strong anti-interference capability, adapting to complex power grid environments.
2.6.2 Backup Power Module
- Battery Type: Valve-regulated lead-acid battery or lithium iron phosphate battery, environmentally friendly and maintenance-free;
- Endurance Capability: Automatically switches to backup battery power upon main power failure. A fully charged backup battery supports ≥12 hours of continuous normal operation, including ≥100 normal door opening operations during this period;
- Charging Management: Built-in intelligent charging management circuit with overcharge, over-discharge, and overcurrent protection, extending battery service life;
- Power Monitoring: Real-time monitoring of battery level, early warning at low battery to remind users to check the power supply;
- Service Life: Under normal usage conditions, battery service life ≥3 years.
2.6.3 Power Switching Mechanism
- Seamless switching between main power and backup power, switching time ≤10ms. During the switching process, the system does not restart, data is not lost, and alarms are not interrupted;
- Power switching events are automatically logged for traceability;
- After main power restoration, the backup battery automatically enters charging mode, automatically transitioning to float charging after full charge.
2.7 Network Communication System
The network communication system enables interconnection between the equipment, the management platform, and mobile terminals, supporting functions such as remote control, data upload, and message push.
2.7.1 Wired Network
- Standard 10/100/1000M adaptive Ethernet interface, supporting TCP/IP protocol;
- Supports both static IP and dynamic IP (DHCP) network configuration modes;
- Supports cross-subnet and cross-VLAN communication, connectable to the unit’s internal LAN.
2.7.2 Wireless Network (Optional)
- Supports Wi-Fi communication, compatible with 802.11b/g/n standards, suitable for scenarios with difficult cabling;
- Supports 4G/5G full-network communication with built-in IoT card slot. Inserting a SIM card enables wireless networking without dependency on the unit’s LAN;
- Supports automatic network reconnection upon disconnection to ensure communication stability.
2.7.3 Communication Protocols
- Supports GB/T 28181 standard protocol, enabling integration with public security video surveillance platforms;
- Supports ONVIF protocol, enabling integration with mainstream security surveillance systems;
- Provides open API interfaces, supporting secondary development integration with users’ existing firearm management systems, OA systems, and police service platforms.
2.7.4 Data Security
- Network transmission data is encrypted using AES-256 encryption algorithm to prevent data theft and tampering;
- Supports bidirectional identity authentication between equipment and platform to ensure connection security;
- Has network firewall functionality to resist network attacks and ensure system security.
2.8 Internal Storage Components
Internal storage components are used for categorized storage of firearms, ammunition, accessories, and other items, with reasonable layout, convenient access, and protection of firearms from impact and damage.
2.8.1 Firearm Storage Components
- Long-Barrel Firearm Rack: Made of cold-rolled steel plate bent into shape with electrostatic powder coating surface treatment. Configured with buttstock fixing seats and muzzle positioning sleeves. Each firearm position is independent, with firearms placed stably and not prone to tipping. The rack is lined with EVA cushioning foam to prevent scratching and wear of firearms;
- Short-Barrel Firearm Seat: Uses a dedicated pistol seat compatible with common police pistols such as Type 92, Type 64, and Type 77. The seat has a locking mechanism. Firearms are automatically locked upon insertion and cannot be unlocked for removal without system authorization;
- Firearm Lock Device: Each firearm is configured with an independent electronic firearm lock. The locking method is the trigger guard locking type, made of zinc alloy, anti-pry and anti-saw. The lock mechanism has an opening/closing service life of ≥100,000 cycles.
2.8.2 Ammunition Storage Components
- Ammunition Drawer: Made of cold-rolled steel plate. Drawer rails are heavy-duty silent sliding rails for smooth push-pull operation, load capacity ≥8kg;
- Ammunition Compartments: The drawer interior is divided into independent ammunition compartments, allowing categorized storage of ammunition by caliber and type. Partition plates are adjustable to accommodate different specifications of ammunition boxes;
- Drawer Lock: Each ammunition drawer is configured with an independent electronic lock, which can be individually authorized to open, achieving separate control of firearms and ammunition.
2.8.3 Auxiliary Storage Components
- Accessory Shelves: Adjustable shelves for storing holsters, magazines, scopes, maintenance tools, and other associated accessories. Shelf load capacity ≥50kg;
- Parts Box: Small accessory drawer for storing gun oil, cleaning cloths, batteries, and other small parts;
- Document Pouch: A document pouch on the inside of the cabinet door for storing firearm management ledgers, user manuals, regulations, and other paper materials.
3 Product List
Upon equipment delivery, please check and verify the following list item by item. If there are quantity shortages, damaged accessories, model mismatches, or other issues, please contact the manufacturer immediately.
3.1 Standard Configuration List
| No. | Part Name | Specification/Model | Unit | Qty | Remarks |
|---|---|---|---|---|---|
| 1 | Intelligent Firearm Cabinet Body | LA-QDG-XX Model | Unit | 1 | Includes cabinet body, door, internal storage structure |
| 2 | Intelligent Control Terminal | LA-ZK-02 | Set | 1 | Includes touch screen, main control board, storage module |
| 3 | Fingerprint Recognition Module | LA-ZW-01 | Unit | 1 | Semiconductor capacitive type |
| 4 | Facial Recognition Module | LA-RL-03 | Unit | 1 | Dual-lens liveness detection |
| 5 | Electronic Firearm Lock | LA-QS-01 | Unit | Per configuration | 1 per firearm position |
| 6 | Ammunition Drawer Electronic Lock | LA-DS-01 | Unit | Per configuration | 1 per drawer |
| 7 | Cabinet Door Electric Control Lock | LA-MS-02 | Set | 1 | Motor-driven type |
| 8 | RFID Presence Detection Module | LA-RFID-01 | Set | 1 | Includes antenna, reader |
| 9 | Temperature and Humidity Sensor | LA-WS-01 | Unit | 1 | High-precision industrial grade |
| 10 | Vibration Sensor | LA-ZD-01 | Unit | 1 | High sensitivity |
| 11 | Door Magnetic Sensor | LA-MC-01 | Unit | 1 | Concealed type |
| 12 | Audible and Visual Alarm Device | LA-SG-01 | Unit | 1 | 110dB |
| 13 | Switching Power Supply | LA-DY-12V5A | Unit | 1 | Industrial grade |
| 14 | Backup Storage Battery | LA-DC-12V7AH | Unit | 1 | Maintenance-free lead-acid |
| 15 | Power Connection Cable | 3×1.0mm², 1.5m | Piece | 1 | With national standard three-pin plug |
| 16 | Network Cable | Cat5e, 2m | Piece | 1 | Finished patch cable |
| 17 | Expansion Bolts | M16×120mm | Set | 4 | For cabinet fixation |
| 18 | Mechanical Emergency Key | Custom toothed | Piece | 2 | For emergency door opening |
| 19 | Product User Manual | Paper version | Copy | 1 | Includes this manual |
| 20 | Product Certificate of Conformity | Factory original | Sheet | 1 | With inspection stamp |
| 21 | Test Report Copy | Ministry of Public Security test | Copy | 1 | With manufacturer’s official seal |
3.2 Optional Accessories List
| No. | Accessory Name | Specification/Model | Unit | Applicable Scenario |
|---|---|---|---|---|
| 1 | Alcohol Detection Module | LA-JJ-01 | Set | Units requiring alcohol testing |
| 2 | 4G Communication Module | LA-4G-01 | Set | Scenarios without wired network |
| 3 | Dehumidification/Heating Module | LA-CS-01 | Set | Humid, high-cold regions |
| 4 | HD Capture Camera | LA-CAM-200W | Unit | Scenarios requiring enhanced image recording |
| 5 | Auxiliary Cabinet Expansion Unit | LA-FG-XX | Unit | Scenarios requiring expanded storage capacity |
| 6 | Management Platform Software | LA-PT-V2.0 | Set | Multi-cabinet centralized management scenarios |
| 7 | UPS Uninterruptible Power Supply | LA-UPS-1KVA | Unit | Scenarios requiring extended power outage endurance |
| 8 | Lightning Protection Module | LA-FL-01 | Set | Installation scenarios in lightning-prone areas |
3.3 Receiving and Acceptance Precautions
- When opening the box, please check whether the outer packaging is intact. If the outer packaging has severe damage or impact marks, take photos for documentation before opening;
- Check each component model and quantity against the list, and inspect the appearance for bumps, scratches, deformation, water ingress, and other issues;
- Check whether electronic accessory packaging is intact and whether there are signs of moisture, electrostatic damage;
- After verification, fill in the arrival acceptance form, signed by both parties;
- Report missing or damaged parts to the manufacturer within 3 working days; the manufacturer will provide free replacement shipment.
4 Product Working Principles
4.1 Overall System Architecture Principle
The intelligent firearm (ammunition) management cabinet adopts a three-layer IoT architecture of “Perception Layer – Control Layer – Application Layer”, collecting status data through various sensors, processing logic and issuing commands through the main control unit, and ultimately realizing application management through human-machine interaction and networked platforms.
- Perception Layer: Composed of identity recognition sensors (fingerprint, facial, IC card), RFID firearm presence sensors, environmental and security sensors (temperature/humidity, vibration, door magnetic). Responsible for collecting various physical signals and converting them into electrical signals for transmission to the control layer;
- Control Layer: Centered on the embedded main control board, running the intelligent control system, analyzing, comparing, and judging data uploaded from the perception layer, generating control commands based on preset rules, driving actuator components such as locks, alarms, and display screens, while also being responsible for data storage and network communication;
- Application Layer: Includes both the local touch terminal operation interface and the remote management platform, providing users with a visualized operation interface for business functions such as firearm issue/return, inventory query, log audit, system settings, and alarm handling.
4.2 Identity Authentication and Door Opening Working Principle
1. The user selects the “open door for issue” function on the touch terminal, and the system prompts for identity verification;
2. The user sequentially performs fingerprint/facial/password/IC card identity verification. Sensors collect biometric features or card number information, transmitting to the main control unit for comparison with authorized information stored in the database;
3. In single-person verification mode, upon successful comparison, the main control unit issues an unlock command to the cabinet door electric control lock. The motor lock actuates, the cabinet door unlocks, and the user can open the door;
4. In dual-person dual-lock mode, after the first user passes verification, the system prompts the second user to verify. The door unlocks only after both users pass verification;
5. If identity verification fails, the system prompts re-verification. After the set number of consecutive failures, the account is locked and an alarm is triggered;
6. During the door opening process, the system automatically records opening time, operator, verification method, and other information, while triggering the camera to capture on-site images stored in the operation log.
4.3 Firearm Presence Detection Working Principle
1. Each firearm is affixed with a unique-ID anti-metal RFID electronic tag. The tag stores firearm serial number, model, owning unit, and other information;
2. An RFID reading antenna is installed beneath each firearm position. The antenna is connected to the RFID reader via a feeder cable;
3. The RFID reader continuously emits radio frequency signals. When a firearm is placed on the position, the tag receives RF energy and feeds back its own ID information;
4. The reader transmits the read tag ID to the main control unit. The main control unit compares against the database to determine the presence of the corresponding firearm;
5. When a firearm is removed, the corresponding antenna cannot read the tag information. The main control unit determines that the firearm is absent, automatically records the absence time, and determines whether it is a normal issue based on the business scenario;
6. Upon firearm return, when placed in the corresponding position, the system automatically recognizes the tag, determines return, updates presence status, and records the return time.
4.4 Alarm System Working Principle
1. Various sensors monitor corresponding status parameters in real time and upload data to the main control unit;
2. The main control unit compares real-time data against preset alarm thresholds. When data exceeds threshold ranges or abnormal conditions occur, it determines an alarm event;
3. The system executes corresponding linkage actions based on the alarm event’s level:
- Level 1 Alarms (illegal door opening, violent destruction): Immediately trigger on-site audible/visual alarm, capture on-site images, upload alarm information to the platform, push messages to administrators, and link surrounding security equipment;
- Level 2 Alarms (overdue non-return, temperature/humidity exceeding): Local voice prompt, push message to administrator, record alarm log;
- Level 3 Alarms (network disconnection, low battery): Interface pop-up prompt, record log, no audible/visual alarm triggered;
4. After the alarm event is handled, the administrator can clear the alarm state through identity verification. The system records the handler, handling time, and handling result.
4.5 Power Switching Working Principle
1. Under normal conditions, the equipment is powered by AC 220V utility power. The switching power supply converts utility power to DC 12V to power each system module, while the charging circuit charges the backup battery;
2. When utility power fails, the power management chip detects the main power voltage drop, immediately issues a switching command, and switches to backup battery power via relay. The switching process is seamless and the system operates without interruption;
3. During backup power supply operation, the system monitors battery voltage in real time. When the voltage drops to the low battery threshold, a low battery alarm is issued to remind users to restore power;
4. When utility power is restored, the power management chip detects the restoration and automatically switches back to utility power, while activating the charging circuit to replenish the battery, automatically transitioning to float charging after full charge.
4.6 Network Communication Working Principle
1. The equipment connects to the unit’s LAN or the internet via wired or wireless network, establishing communication with the remote management platform;
2. The equipment periodically uploads heartbeat packets to the platform to report online status, while uploading real-time operational data including door status, firearm presence status, temperature/humidity data, and alarm information;
3. The platform can issue control commands to the equipment, such as remote door opening, remote cabinet lockdown, parameter settings, and firmware upgrades. The equipment executes commands upon receipt and feeds back results;
4. All communication data is encrypted, employing a full-chain encryption mechanism of “device-end encryption – transmission channel encryption – platform-end decryption” to ensure data transmission security.
5 Product Technical Parameters
5.1 Cabinet Physical Parameters
| Parameter Item | Technical Indicator | Applicable Standard |
|---|---|---|
| External Dimensions (H×W×D) | 1800mm×1000mm×600mm (standard model, customizable) | GA 1051-2013 |
| Cabinet Steel Plate Thickness | ≥6mm (Q345B high-quality carbon steel) | GA 1051-2013 |
| Cabinet Door Steel Plate Thickness | ≥10mm (outer layer) + 3mm (inner layer), anti-drill steel plate sandwiched in between | GA 1051-2013 |
| Bolt Specification | Diameter ≥25mm, extension length ≥25mm, ≥5 per door leaf | GA 1051-2013 |
| Cabinet Door Opening Angle | ≥90° | GA 1051-2013 |
| Door Gap | ≤0.2mm | GA 1051-2013 |
| Cabinet Diagonal Error | ≤4mm | GA 1051-2013 |
| Total Cabinet Weight | ≥350kg (standard model) | GA 1051-2013 |
| Shelf Load Capacity | ≥50kg, deformation ≤2mm | GA 1051-2013 |
| Drawer Load Capacity | ≥8kg, opening/closing service life ≥20,000 cycles | GA 1051-2013 |
| Anti-Destruction Time | Anti-technical-opening ≥10min, anti-forced-destruction ≥30min | GA 1051-2013 |
| Fire Resistance Rating | ≥60min (Class B) | GB/T 7633-2008 |
| Surface Treatment | Electrostatic powder coating, thickness ≥60μm, anti-corrosion and anti-rust | / |
5.2 Electrical System Parameters
| Parameter Item | Technical Indicator | Remarks |
|---|---|---|
| Rated Input Voltage | AC 220V±10%, 50Hz | Utility power supply |
| System Operating Voltage | DC 12V | Unified internal power supply |
| Rated Power | ≤60W (standby), ≤120W (peak) | Including all modules |
| Backup Power Type | 12V 7Ah valve-regulated lead-acid battery | Maintenance-free |
| Backup Endurance Time | ≥12 hours (normal standby), ≥100 door opening operations | Fully charged state |
| Power Switching Time | ≤10ms | Seamless switching |
| Insulation Resistance | ≥100MΩ | At normal temperature and humidity |
| Withstand Voltage | AC 1500V, 1min without breakdown or arcing | Electrical safety |
| Grounding Resistance | ≤4Ω | Safety grounding |
| Operating Temperature | -10°C ~ +60°C | Industrial grade |
| Storage Temperature | -20°C ~ +70°C | / |
| Relative Humidity | 20% ~ 90%RH, no condensation | / |
5.3 Intelligent Control System Parameters
| Parameter Item | Technical Indicator |
|---|---|
| Main Control Processor | ARM quad-core, main frequency ≥1.5GHz |
| Operating System | Embedded Linux |
| Display Screen | 10.1-inch capacitive touch screen, resolution 1280×800 |
| Storage Capacity | 8GB eMMC, expandable |
| Log Storage Capacity | ≥100,000 entries |
| Captured Image Storage | ≥5,000 images |
| User Information Capacity | ≥10,000 persons |
| Fingerprint Storage Capacity | ≥10,000 prints |
| Facial Storage Capacity | ≥5,000 faces |
| Response Time | Identity verification ≤1s, door opening response ≤0.5s |
| Data Refresh Frequency | Presence status ≤1s, temperature/humidity ≤5s |
5.4 Identity Recognition Module Parameters
5.4.1 Fingerprint Recognition Module
| Parameter Item | Technical Indicator |
|---|---|
| Sensor Type | Semiconductor capacitive |
| Sensing Area | 10mm×10mm |
| Resolution | 508DPI |
| False Acceptance Rate (FAR) | ≤0.001% |
| False Rejection Rate (FRR) | ≤1% |
| Recognition Time | ≤1s |
| Fingerprint Angle | 360° full-angle recognition |
| Liveness Detection | Supported |
5.4.2 Facial Recognition Module
| Parameter Item | Technical Indicator |
|---|---|
| Camera | Dual-lens infrared + visible light, 2 million pixels |
| Recognition Method | Deep learning algorithm, liveness detection |
| False Acceptance Rate (FAR) | ≤0.001% |
| False Rejection Rate (FRR) | ≤0.1% |
| Recognition Accuracy | ≥99.5% |
| Recognition Distance | 40cm ~ 120cm |
| Recognition Time | ≤1.2s |
| Adaptable Illumination | 0 ~ 10000Lux, supports backlight, low light |
5.5 Lock System Parameters
5.5.1 Cabinet Door Electronic Lock
| Parameter | Specification |
|---|---|
| Lock Type | Motor-driven anti-theft lock |
| Lock Bolt Material | Alloy steel |
| Drive Voltage | DC 12V |
| Operating Current | ≤500mA (continuous), ≤5A (instantaneous surge) |
| Opening/Closing Life | ≥100,000 cycles |
| Anti-Pry Rating | Level C |
| Power Failure State | Remains locked |
| Emergency Release | Mechanical key supported |
5.5.2 Electronic Gun Lock
| Parameter | Specification |
|---|---|
| Lock Type | Trigger-locking electronic gun lock |
| Material | Zinc alloy |
| Drive Voltage | DC 12V |
| Operating Current | ≤300mA |
| Opening/Closing Life | ≥100,000 cycles |
| Locking Method | Automatic locking, motorized unlocking |
| Anti-Jamming Function | Built-in automatic rebound function |
| Compliance Standard | GA 1051-2013 |
5.6 Environmental and Safety Detection Parameters
- Temperature/Humidity Measurement: Temperature -20℃~80℃, accuracy ±0.5℃; Humidity 0~100% RH, accuracy ±3% RH
- Vibration Detection: Multi-level adjustable sensitivity, detection acceleration 0.1g~10g
- Door Magnetic Detection: Response time ≤0.1s, detection distance ≤30mm
- RFID Detection: Operating frequency 13.56MHz, reading distance 0~10cm, recognition accuracy 100%
- Alarm Volume: ≥110dB
5.7 Network Communication Parameters
- Wired Network: 10/100/1000M auto-negotiation Ethernet, RJ45 interface
- Wireless Network: Wi-Fi 802.11b/g/n (optional)
- 4G Communication: Full-network 7-mode (optional)
- Communication Protocols: TCP/IP, HTTP, MQTT, GB/T 28181, ONVIF
- Encryption Methods: AES-256, SSL/TLS
- Network Latency: ≤100ms (within LAN)
6.1 Core Control Functions
6.1.1 Firearm and Ammunition Issuance/Return Management
- Supports single-person, dual-person, and multi-person issuance modes, flexibly configurable according to unit management policies;
- Issuance process: Identity verification → Select firearm/ammunition → Confirm purpose → Open door and retrieve → Automatic system recording;
- Return process: Identity verification → Place firearm/ammunition → Automatic system verification → Close door and lock → Generate return record;
- Automatically verifies firearm model and quantity upon return. System immediately alerts and alarms in cases of incorrect or missing returns, preventing misplacement and omission;
- Supports purpose registration for issuance, including options such as duty, training, escort, and emergency, facilitating statistical analysis.
6.1.2 Real-Time Inventory Management
- Displays real-time presence status and quantity information of all firearms and ammunition in the cabinet, providing clear inventory visibility;
- Supports classified query by firearm model, caliber, assigned personnel, and other dimensions;
- Automatic inventory counting function, one-click generation of inventory count reports, automatic comparison between ledger and actual inventory, with differences automatically flagged;
- Supports inventory warning — automatically notifies administrator to replenish when ammunition quantity falls below safety stock level.
6.1.3 Personnel Access Rights Management
- Supports multi-level role management. System defaults include Super Administrator, Gun Custodian, Gun Requester, and Approver roles, with custom role permissions also supported;
- Fine-grained permission allocation — operation permissions can be assigned to specific gun positions, specific drawers, and specific function modules;
- Supports time-based permission control — personnel can be granted access rights only during designated time periods; issuance is prohibited outside working hours;
- Supports batch import/export of personnel information; permissions can be revoked with one click upon employee departure or transfer, ensuring permission security.
6.1.4 Operation Logs and Traceability
- Full operation traceability — all door openings, issuances, returns, settings, alarms, and faults are automatically recorded in logs;
- Log contents include: operation time, operator, operation type, operation object, operation result, on-site captured images, etc.;
- Supports multi-condition combined queries — logs can be filtered by time, personnel, event type, etc.;
- Logs cannot be tampered with or deleted, meeting audit traceability requirements;
- Supports log export in Excel and PDF formats for archival reference.
6.2 Security Protection Functions
6.2.1 Multi-Factor Identity Verification
- Supports multiple authentication methods: fingerprint, face, password, IC card, and alcohol detection, with freely combinable authentication modes;
- Supports single-factor, dual-factor, and multi-factor authentication, with security levels configurable as required;
- Strictly implements the dual-person dual-lock management system — door can only be opened when two authorized personnel are simultaneously present and verified;
- Equipped with liveness detection, effectively defending against fake fingerprints, photos, videos, and other deception methods.
6.2.2 Multi-Level Alarm Linkage
- Full coverage of 9 major alarm event categories, leaving no safety risks unaddressed;
- Multi-level notification via local audible/visual alarm, platform pop-up alarm, SMS/APP push notification, and email alarm;
- Alarm classification and graded response mechanism — different alarm events correspond to different response levels;
- Full tracking of alarm events, from trigger, notification, and handling through to archival — complete end-to-end records;
- Supports one-key cabinet lockdown function — administrator can remotely or locally lock all cabinet doors in emergencies, prohibiting any access or storage operations.
6.2.3 Physical Anti-Vandalism Protection
- High-strength all-steel cabinet body, resistant to prying, drilling, cutting, and impact;
- Multi-point linked door bolts for protection against forced entry;
- Concealed hinges, anti-removal design;
- Built-in anti-drill steel plate to resist electric drill attacks;
- Cabinet secured to floor with expansion bolts to prevent entire-unit removal.
6.2.4 Data Security Protection
- Local data encrypted storage, preventing data leakage;
- Full-link encryption for network transmission, preventing data theft and tampering;
- Bidirectional authentication between device and platform, preventing unauthorized access;
- Immutable operation logs, ensuring data authenticity;
- Automatic data backup, preventing data loss.
6.3 Smart Convenience Features
6.3.1 Intelligent Interaction
- 10.1-inch high-definition touchscreen with graphical Chinese interface, intuitive operation;
- Full voice guidance throughout the process, providing clear step-by-step prompts;
- Visualized status — device operating status, firearm status, power status, and network status at a glance;
- Smart reminders, including maintenance reminders, battery replacement reminders, password expiration reminders, and overdue return reminders.
6.3.2 Environmental Adaptability
- Built-in temperature and humidity monitoring, automatically regulating the cabinet internal environment;
- Optional dehumidification and heating module, automatically adjusting temperature and humidity in humid or cold regions to prevent firearm rust and corrosion;
- Wide temperature range design, adapting to different climates across northern and southern regions;
- Wide voltage range design, adapting to grid fluctuations, ensuring stable operation even in areas with unstable voltage.
6.3.3 Flexible Expansion
- Modular design, function modules can be optionally configured as needed;
- Supports main cabinet and slave cabinet cascade connection, with up to 8 slave cabinets cascadable for large-capacity storage needs;
- Provides open API interfaces, supporting integration with third-party systems;
- Supports remote firmware upgrades, with continuous feature iteration and optimization.
6.4 Core Product Features
- High Compliance: Fully compliant with GA 1051-2013 and multiple national and industry standards, certified by the Ministry of Public Security, ensuring smooth acceptance;
- High Security: Integrated physical, technical, and human defense, multi-level protection and verification, ensuring comprehensive firearm safety;
- High Intelligence: RFID automatic recognition, biometric identification, automatic counting, and automatic recording, greatly reducing manual workload;
- Stable and Reliable: Industrial-grade hardware configuration, wide temperature and voltage design, 24/7 stable operation, low failure rate;
- Excellent Usability: Simple interface, easy operation, usable without professional training;
- Strong Expandability: Supports function expansion, capacity expansion, and system integration, adapting to personalized needs of different units;
- Comprehensive Service: Manufacturer provides full technical support, from solution design, installation, and commissioning through training and maintenance — full lifecycle services.
The Intelligent Firearm (Ammunition) Management Cabinet is widely used in various units and locations requiring standardized storage and management of firearms and ammunition. Depending on the scale of the usage scenario and management requirements, suitable models and configuration solutions can be flexibly selected.
7.1 Public Security System Scenarios
7.1.1 Grassroots Police Stations
- Scenario characteristics: Relatively small quantity of firearms (typically 10~20 sidearms, small amount of ammunition), 24-hour duty, frequent issuance and return, strict management procedures;
- Recommended solution: Single-cabinet intelligent firearm/ammunition integrated cabinet, configured with sidearm positions and ammunition drawer, supporting dual-person dual-lock, fingerprint + face authentication, integrated into police station security platform;
- Value delivered: Replaces traditional mechanical safes, digitalizes firearm management, implements the dual-person dual-lock system, automatically generates ledgers, reduces police workload, and meets inspection requirements from higher authorities.
7.1.2 District/Municipal Bureau Armory
- Scenario characteristics: Large quantity of firearms (tens to hundreds of long guns and sidearms, large amount of ammunition), strict management standards, requiring centralized control, graded approval, and full traceability;
- Recommended solution: Main and slave cabinet combined intelligent armory system, configured with long gun cabinets, sidearm cabinets, and ammunition cabinets, unified management platform, supporting multi-level approval, remote monitoring, and data statistical analysis;
- Value delivered: Achieves centralized and unified management of firearms across the bureau, real-time inventory visibility, standardized issuance processes, full traceability, elevates firearm safety management level, and meets public security armory construction standards.
7.1.3 SWAT/Patrol Units
- Scenario characteristics: Numerous emergency tasks, irregular issuance and return times, requiring rapid retrieval while maintaining strict control;
- Recommended solution: Emergency-response intelligent firearm cabinet, supporting emergency issuance mode, optimized verification process, fast door opening, while retaining complete records and alarm functions;
- Value delivered: Balances emergency response speed with safety control, enables rapid firearm retrieval in emergencies, with complete post-event traceability of the issuance process.
7.2 Military and Armed Police Scenarios
7.2.1 Company-Level Arms Room
- Scenario characteristics: Firearms and ammunition allocated according to organizational structure, centralized daily storage, issued for training and duty, strict management, compliant with military standards;
- Recommended solution: Military-standard intelligent firearm cabinet, compliant with relevant GJB standards, featuring moisture-proof, dust-proof, and salt-spray-resistant performance, supporting integration with military identity authentication systems;
- Value delivered: Implements military firearm management policies, elevates arms room intelligence management level, reduces manual guard duty pressure, and safeguards weapon equipment security.
7.2.2 Brigade/Regiment-Level Ordnance Depot
- Scenario characteristics: Large-capacity storage, multiple categories of firearms and ammunition, graded management, strict approval, and regular counting;
- Recommended solution: Large-scale intelligent armory system, three-dimensional storage layout, automated counting, integrated management platform, interfacing with military ordnance management systems;
- Value delivered: Achieves digitalization and intelligent management of ordnance depots, improves inventory accuracy, reduces management costs, and ensures ledger-inventory consistency for weapon equipment.
7.3 Other Firearm-Related Unit Scenarios
7.3.1 Armed Escort Companies
- Scenario characteristics: Firearms issued and returned with each mission, rotating shifts, high personnel turnover, requiring strict control over personnel permissions and issuance time limits;
- Recommended solution: Networked intelligent firearm cabinet, supporting remote approval, time-limit control, GPS positioning linkage, and full mission traceability;
- Value delivered: Standardizes escort firearm management, prevents unauthorized retention of firearms, implements firearm handover procedures, and ensures firearm safety during escort operations.
7.3.2 Civilian Shooting Ranges
- Scenario characteristics: Large quantity of firearms, diverse users, requiring strict identity verification, full-process usage control, and overstay warnings;
- Recommended solution: Range-specific intelligent firearm cabinet, supporting member management, session management, overtime reminders, and integration with range billing systems;
- Value delivered: Standardizes shooting range firearm management, prevents firearm loss, implements real-name registration policies, and meets public security regulatory requirements for shooting ranges.
7.3.3 Security Service Companies
- Scenario characteristics: Numerous armed security personnel, widely distributed, centralized storage, shift-based issuance, requiring strict attendance and permission correspondence;
- Recommended solution: Multi-cabinet centralized management solution, interfacing with security attendance systems, with shift information automatically syncing permissions — personnel not on duty have no access rights;
- Value delivered: Achieves integrated management of firearms and personnel scheduling, eliminates unauthorized issuance, and raises the standardization level of security company firearm management.
7.4 Special Environment Scenarios
7.4.1 High-Altitude Cold and High-Humidity Regions
- Environmental characteristics: Cold winters, humid summers, firearms prone to rust, standard equipment prone to malfunction;
- Recommended solution: Enhanced environmental control firearm cabinet, equipped with dehumidification and heating modules, anti-corrosion treated cabinet body, adapted to harsh environments;
- Value delivered: Ensures firearm storage environment meets standards, prevents rust and failure, and ensures stable equipment operation in harsh conditions.
7.4.2 Coastal Salt-Spray Regions
- Environmental characteristics: High salt content in air, metal components prone to corrosion;
- Recommended solution: Salt-spray-resistant firearm cabinet, 304 stainless steel cabinet body, special anti-corrosion surface treatment, electronic components with conformal coating (three-proof treatment);
- Value delivered: Extends equipment service life, prevents structural damage and functional failure caused by corrosion.
7.4.3 Remote Areas Without Network Access
- Environmental characteristics: No wired network, poor communication conditions;
- Recommended solution: 4G-connected or standalone firearm cabinet, with built-in 4G module or offline operation support, local data storage, and periodic export backup;
- Value delivered: Resolves network challenges in remote areas, enables intelligent management, and ensures data traceability.
8.1 Pre-Installation Preparation
8.1.1 Installation Environment Requirements
- Site Space: Sufficient space must be reserved at the installation location. Front clearance ≥1000mm for operation, side clearance ≥300mm for maintenance, top clearance ≥200mm for heat dissipation;
- Floor Requirements: Installation floor must be level and solid, load-bearing capacity ≥500kg/m², floor slope ≤2°. If wooden or raised access flooring, reinforcement must be carried out to ensure adequate load capacity;
- Environmental Conditions: Installation location should be away from water sources, heat sources, and open flames, avoiding direct sunlight. Ambient temperature -5℃~45℃, relative humidity ≤85% RH, no corrosive gases, no strong electromagnetic interference;
- Power Supply: Reliable AC 220V wall outlet must be available near the installation location, with proper grounding, circuit capacity ≥200W, and a dedicated circuit breaker recommended;
- Network Conditions: If networking is required, a network cable interface or Wi-Fi/4G signal coverage must be available at the installation location;
- Safety Requirements: Installation location shall comply with GA 1016-2012 standard requirements, located in an independent enclosed room with corresponding human, physical, and technical security measures in place.
8.1.2 Installation Tool Preparation
The following tools must be prepared before installation:
- Measuring tools: Tape measure, spirit level, plumb bob, marker pen;
- Drilling tools: Rotary hammer drill, demolition hammer drill, φ18mm drill bit;
- Fastening tools: Socket wrench set, adjustable wrench, hex key set, screwdriver set (Phillips and flat-head);
- Electrical tools: Multimeter, wire stripper, crimping tool, insulating tape, cable ties;
- Auxiliary tools: Pry bar, rubber mallet, gloves, cleaning cloth, vacuum cleaner;
- Safety protection: Safety helmet, safety goggles, safety work shoes.
8.1.3 Receiving Inspection and Handling
- Upon equipment arrival, open the box at the installation site to verify the equipment appearance is intact, all accessories are complete, and there is no transit damage;
- Equipment handling requires 4 or more personnel working cooperatively, using a manual hydraulic pallet truck or forklift. Pushing/pulling by a single person or tilting the cabinet over is strictly prohibited;
- Keep the cabinet upright during handling; tilt angle must not exceed 15°, avoid severe vibration and impact;
- After moving to the installation location, remove the outer packaging, clean up debris at the site, and prepare for installation positioning.
8.2 Cabinet Positioning and Fixing
8.2.1 Positioning and Layout Marking
- Determine the cabinet installation position according to the design plan, measure with tape measure to verify cabinet distance from walls and surrounding equipment meets requirements;
- Use a spirit level to assist; mark the cabinet bottom outline and expansion bolt drilling positions;
- Standard cabinet bottom has 4 fixing holes located at four corners; mark drilling points accordingly;
- Verify hole spacing matches the cabinet bottom mounting holes.
8.2.2 Drilling Operation
- Use a demolition hammer drill with φ18mm drill bit; drilling depth ≥120mm;
- Keep the drill perpendicular to the floor during drilling to avoid tilted drilling that may prevent proper expansion bolt installation;
- After drilling, use a vacuum cleaner to remove dust and debris from the holes, ensuring holes are clean;
- Check drilling depth and diameter to confirm expansion bolts can be fully inserted.
8.2.3 Cabinet Positioning and Leveling
- Multiple personnel cooperatively lift the cabinet, slowly move it to the marked position, and gently lower it into place aligning with the drilled points;
- Insert expansion bolts through the cabinet bottom mounting holes into the drilled holes;
- Use a spirit level to measure the levelness of the cabinet front and side surfaces; adjust the bottom leveling feet to level the cabinet, ensuring verticality with a tilt ≤1°;
- After leveling, sequentially tighten the nuts of all 4 expansion bolts evenly to ensure the cabinet is firmly secured without wobble;
- Re-check levelness after final tightening; re-adjust if any deviation is found.
8.2.4 Fixing Acceptance
- Push the cabinet by hand to check stability — no wobble or displacement;
- Verify expansion bolts are fully tightened and washers are present;
- Verify cabinet verticality and levelness meet requirements;
- Clean dust and debris from cabinet surface and floor.
8.3 Internal Component Installation
8.3.1 Gun Rack and Gun Cradle Installation
- Open cabinet door, inspect pre-installed gun rack fixing hole positions inside;
- Install long gun racks or sidearm cradles according to the configured gun position quantity, align with holes, and secure with screws;
- Adjust rack spacing to ensure guns do not interfere with each other when placed and are easy to retrieve;
- Install gun lock devices and connect gun lock control cables to corresponding terminals on the main control board;
- Test each gun lock for normal open/close operation and any jamming.
8.3.2 Ammunition Drawer Installation
- Remove the inner rail of the drawer slide, secure with screws to corresponding positions on both sides of the cabinet body;
- Align drawer with slide rails and push in, ensuring slide rails engage properly;
- Test drawer push/pull smoothness — no sticking, jamming, or abnormal noise;
- Connect drawer electronic lock control cables and test lock open/close functionality.
8.3.3 Sensor and Accessory Installation
- Install temperature/humidity sensor, fixed to the middle side wall of the cabinet interior, away from direct airflow outlets and heat sources;
- Install vibration sensor, fixed to the center of the cabinet back panel, ensuring rigid connection to the cabinet body;
- Install door magnetic sensors, fixed to corresponding positions on the cabinet door and cabinet body, aligning and fitting together when the door is closed;
- Install audible/visual alarm device, fixed to the top exterior of the cabinet, facing the direction of personnel activity;
- Organize all connecting cables, route along the cabinet side walls, and secure neatly with cable ties.
8.4 Installation Safety Precautions
- Installation work must be performed by 2 or more professional technicians; single-person operation is strictly prohibited;
- Wear safety goggles during drilling operations to prevent injury from flying debris;
- During cabinet handling, take protection against falling objects; multiple personnel must work in coordinated unison;
- During installation, never insert hands, head, or other body parts between the cabinet door and cabinet body to prevent pinch injuries;
- Ensure power is disconnected before any electrical wiring work; live working is strictly prohibited;
- No open flames at the installation site; fire extinguishing equipment must be available;
- After installation, clean the site and inventory tools to prevent tools from being left inside the cabinet.
9.1 Overall Wiring Specifications
9.1.1 Cable Selection Standards
All wiring must use certified cables meeting national standards. Specific selections are as follows:
| Cable Type | Specification | Application |
|---|---|---|
| Main power cable | RVV 3×1.0mm² copper-core PVC insulated flexible cable | Mains power input |
| DC power cable | RVV 2×0.75mm² copper-core flexible cable | 12V DC power transmission |
| Control signal cable | RVSP 2×0.5mm² twisted shielded pair | Sensor and lock control signal transmission |
| Network cable | Category 5e UTP (Unshielded Twisted Pair) | Wired network communication |
| Ground cable | BVR 2.5mm² yellow/green two-color stranded copper wire | Equipment grounding |
All cables must have 3C certification, with flame retardant rating not lower than Class B.
9.1.2 Wiring Workmanship Requirements
- Before wiring, verify cable specifications, colors, and interface definitions; proceed only after confirmation;
- Use dedicated wire strippers for stripping, with strip length of 5~8mm; do not damage copper conductors and ensure no broken strands;
- Wire terminals must use cold-pressed terminal lugs, crimped securely with no looseness or false contact; stranded wires must be twisted together before crimping, with no exposed copper strands;
- After inserting wire terminals into corresponding connectors, tighten fixing screws and verify terminals do not detach under pull test;
- After wiring, label wire numbers for later maintenance and troubleshooting;
- All wiring must be neatly routed, straight and level, secured with cable ties, avoiding crossing and tangling;
- Strong-current and weak-current wiring must be routed separately with a spacing of ≥30cm to avoid electromagnetic interference;
- Shielded cable should be grounded at single point (main control board end); shield layer must not short-circuit to the chassis.
9.1.3 Safe Operation Requirements
- All wiring work must be performed in a de-energized state; live wiring is strictly prohibited;
- Before wiring, use a multimeter to confirm the circuit is de-energized before proceeding;
- Wiring personnel must wear insulating gloves and insulating shoes;
- After completing wiring, carefully inspect to confirm no shorts, no reverse connections, and no false contacts before energizing for testing;
- When energizing for testing, first perform a momentary power-on test, then continuous power-on only after confirming no abnormalities.
9.2 Power System Wiring
9.2.1 Mains Input Wiring
- Connect one end of the national standard three-pin power plug to the wall outlet, and the other end to the power input terminals on the rear of the cabinet;
- Terminal definitions: L terminal connects to phase wire (live/hot wire, typically brown/red), N terminal connects to neutral wire (typically blue/black), PE terminal connects to ground wire (yellow/green two-color);
- When wiring, first connect the PE ground wire, then the N neutral wire, and finally the L phase wire;
- After wiring, use a multimeter to measure resistance between input terminals to confirm no short circuit.
9.2.2 Switching Power Supply Wiring
- Connect the mains input terminal output to the AC input terminals (L, N) of the switching power supply;
- Connect the DC output terminals (V+, V-) of the switching power supply to the power input terminals of the main control board; V+ to positive, V- to negative — reverse connection is strictly prohibited;
- Connect the switching power supply ground terminal (GND) to the cabinet ground bus bar;
- Connect the backup battery positive/negative terminals to the battery terminals of the power management module — red to positive, black to negative; reverse connection is strictly prohibited;
- Verify all power wiring polarities are correct and connections are secure.
9.2.3 Grounding Wiring
- A dedicated ground terminal is provided at the cabinet bottom; connect with BVR 2.5mm² yellow/green two-color ground cable to the building grounding grid or ground electrode;
- Ground resistance must be ≤4Ω; verify with a ground resistance tester;
- The switching power supply, main control board, and equipment chassis must all be reliably connected to the ground terminal for equipotential grounding;
- Ground cables must not be connected in series, must not pass through switches or fuses, and must be directly and reliably connected.
9.3 Main Control Unit Wiring
The main control board is the connection hub for all devices. When wiring, refer to the wiring diagram and connect each interface accordingly.
9.3.1 Power Interface
- Label: DC12V_IN (+, -)
- Connect to switching power supply DC output terminals; positive to +, negative to –
- Note: Polarity must never be reversed, otherwise the main control board will be damaged.
9.3.2 Lock Control Interfaces
| Interface | Designation | Description |
|---|---|---|
| Cabinet door electronic lock | LOCK_DOOR (NO, COM, NC) | Lock control output |
| Gun lock bus | GUN_LOCK_485 (A, B, GND) | RS485 gun lock bus |
| Drawer lock bus | DRAWER_LOCK_485 (A, B, GND) | RS485 drawer lock bus |
For motor-driven lock devices, distinguish between power supply wires and signal wires, and connect strictly according to definitions.
9.3.3 Sensor Interfaces
| Sensor | Interface | Description |
|---|---|---|
| Door magnetic | DOOR_SENSOR (IN1, GND) | Door status input |
| Vibration | VIBRATION (IN2, GND) | Vibration detection input |
| Temperature/Humidity | TEMP_HUM (SDA, SCL, GND, VCC) | I2C bus interface |
Sensor signal cables use shielded cable with shield layer connected to GND.
9.3.4 Identity Recognition Module Interfaces
| Module | Interface | Description |
|---|---|---|
| Fingerprint module | FINGER (TX, RX, VCC, GND) | Serial interface |
| Face recognition module | FACE (USB or Ethernet port) | USB or network connection |
| IC card reader | CARD (TX, RX, VCC, GND) | Serial interface |
Note: TX and RX must be cross-connected — module TX to main control RX, module RX to main control TX.
9.3.5 Alarm Output Interfaces
| Interface | Designation | Description |
|---|---|---|
| Audible/visual alarm | ALARM_OUT (+, -) | Direct alarm output |
| Alarm linkage output | ALARM_LINK (NO, COM) | For external alarm host connection |
Alarm output is relay contact output. Note the load capacity; do not connect high-power devices directly.
9.3.6 Network Communication Interfaces
| Interface | Designation | Description |
|---|---|---|
| Wired Ethernet | LAN (RJ45) | Connect to LAN switch or router |
| 4G module interface | 4G_MODULE (Mini PCIe or USB) | Insert SIM card, then connect antenna |
9.4 Detailed Wiring Steps for Each Module
9.4.1 Cabinet Door Electronic Lock Wiring
1. Use RVV 2×0.75mm² cable, length determined by actual routing distance;
2. Connect one end to the COM and NO terminals of ALARM_OUT/LOCK_DOOR on the main control board;
3. Connect the other end to the electronic lock power input terminals; positive to the line connected through NO, negative to power supply negative;
4. Operating principle: In normal state, the relay is open and the lock is not energized, remaining locked; after identity verification, the relay closes, energizing the lock for unlocking;
5. After wiring, test normal lock open/close operation, checking for abnormal noise or heating.
9.4.2 RFID Presence Detection Module Wiring
1. Install the RFID reader at the cabinet bottom or side wall, secured with screws;
2. Connect the RFID antenna for each gun position to the reader antenna ports via feeder cables; feeder length should be moderate, avoiding excessive bending;
3. Connect the reader to the corresponding main control board interface via RS485 bus (A, B, GND);
4. Reader power is provided by the main control board 12V output; note positive/negative polarity;
5. After wiring, test tag reading for each gun position.
9.4.3 Face Recognition Module Wiring
1. Install the face recognition terminal at the reserved position on the exterior of the cabinet door, secured firmly;
2. Connect via USB cable or network cable to the corresponding main control board interface;
3. Connect 12V DC power cable, matching positive/negative terminals;
4. Route cables through the cable pass-through hole at the door hinge into the cabinet, avoiding cable strain when opening/closing the door;
5. Test face recognition function to confirm normal recognition and clear image quality.
9.4.4 Audible/Visual Alarm Wiring
1. Install the audible/visual alarm at the cabinet top, facing the direction of personnel activity;
2. Use RVV 2×0.5mm² cable, connecting to the alarm output terminals on the main control board;
3. Connect positive to ALARM_OUT+, negative to ALARM_OUT-;
4. After wiring, trigger a test alarm to verify that alarm volume and indicator lights function properly.
9.5 Wiring Inspection and Testing
9.5.1 Wiring Visual Inspection
- Check all connections for security and terminal screws for tightness;
- Check cable identification markings for clarity, cable routing for neatness, and absence of crossing and tangling;
- Check shield layer grounding correctness and absence of short circuits;
- Check that strong-current and weak-current wiring are separated and that spacing meets requirements;
- Check that all grounding points are reliably connected.
9.5.2 Electrical Performance Testing
- Before energizing, use a multimeter to measure resistance between power supply positive and negative terminals to confirm no short circuit;
- Measure resistance between signal wires, and between signal wires and ground, to confirm no short or false contact;
- Measure input power supply voltage, confirming it is within 220V ±10% range;
- Momentarily energize and observe the equipment for smoke, abnormal sound, or odor; power off immediately if any abnormality is found;
- After normal energization, measure supply voltage of each module to confirm it is within rated range.
9.5.3 Basic Functional Testing
- Test the cabinet door electronic lock open/close operation;
- Test that each sensor signal uploads correctly;
- Test that identity recognition modules operate normally;
- Test that alarm functions trigger correctly;
- Test network connectivity.
After equipment installation and wiring are completed, comprehensive and systematic commissioning must be performed to ensure all functions operate normally, performance meets standards, and operation is stable before handover. The commissioning process is divided into four stages: standalone commissioning, system functional commissioning, networked integration testing, and trial operation.
10.1 Pre-Commissioning Preparation
10.1.1 Commissioning Tools and Documentation
- Commissioning tools: Multimeter, laptop computer, USB flash drive, voltage tester, stopwatch, sound level meter, temperature/humidity meter;
- Documentation: Product wiring diagram, system commissioning manual, parameter configuration table, user permission list;
- Test items: Test firearm replicas, test ammunition, authorized fingerprints/faces/cards, test computer.
10.1.2 Commissioning Environment Confirmation
- Confirm installation is secure, levelness and verticality meet requirements;
- Confirm all wiring is complete and verified correct;
- Confirm mains power supply is normal and voltage is stable;
- Confirm network environment is ready, with IP address and other parameters clearly defined;
- Clean the commissioning site, evacuate unrelated personnel, and ensure commissioning safety.
10.2 Standalone Power-On Commissioning
10.2.1 Power-On Initialization
1. Close the power switch and observe the equipment startup process;
2. System startup time should be ≤30s; during startup, the display screen sequentially shows the boot screen and system loading interface;
3. After startup, the standby interface appears; check that power and operating indicator lights are normal;
4. Observe the equipment for abnormal sound, smoke, or odor; touch the enclosure to check for abnormal heating.
10.2.2 Basic Parameter Configuration
1. Enter the system settings interface and set system time and date, ensuring accuracy;
2. Set network parameters — in static IP mode, enter IP address, subnet mask, gateway, and DNS;
3. Set device number, organization name, installation location, and other basic information;
4. Set human-machine interaction parameters such as language, volume, and brightness;
5. Set environmental parameters such as temperature/humidity alarm thresholds and vibration sensitivity.
10.2.3 Individual Module Commissioning
(1) Display and Touch Commissioning
- Test all areas of the touchscreen for touch sensitivity, checking for touch offset or non-responsive regions;
- Test screen display quality — check color and brightness for correctness, and inspect for dead pixels and bright lines;
- Test voice broadcast functions — verify each operation prompt voice is clear and accurate.
(2) Lock System Commissioning
- Test the cabinet door electronic lock: control lock opening/closing via system test commands, repeat 10 times, check smooth operation, absence of jamming, and abnormal noise;
- Test electronic gun locks: test unlock and lock for each gun position one by one, check correct actuation and accurate feedback;
- Test ammunition drawer locks: test open/close of each drawer lock one by one, check smooth lock bolt extension and retraction.
(3) Sensor System Commissioning
- Door magnetic test: open and close the cabinet door, check that the door magnetic status on the system interface changes in sync, with response time ≤0.5s;
- Vibration test: lightly tap the cabinet body to trigger vibration alarm, check sensitivity and alarm response;
- Temperature/humidity test: compare measured values from a reference temperature/humidity meter with system displayed values; errors must be within allowable range;
- RFID test: place test firearms with tags one by one, check the system accurately identifies presence; verify the system indicates “removed” after retrieval.
(4) Identity Recognition Commissioning
- Fingerprint commissioning: enroll test fingerprints, perform multiple recognition tests, check recognition speed and accuracy; test recognition under different angles and wet/dry finger conditions;
- Face commissioning: enroll test face data, perform multiple recognition tests, check recognition under different distances, lighting conditions, and angles; test liveness detection function;
- Password commissioning: set test password, verify password unlock function, test lockout function after consecutive incorrect entries;
- IC card commissioning: test card swiping recognition function, check reading distance and response speed.
(5) Alarm System Commissioning
- Simulate unauthorized door opening: forcefully pry the cabinet door, check triggering of on-site audible/visual alarm and system alarm log recording;
- Simulate vibration alarm: strike the cabinet body, check alarm trigger functionality;
- Test alarm reset: verify administrator identity to reset alarm, check alarm stops and records are complete;
- Test audible/visual alarm volume: measure with sound level meter, volume at 1m distance must be ≥110dB.
(6) Power System Commissioning
- Test main power supply operation status, measuring output voltage stability;
- Test backup power switching: disconnect mains power, check automatic switchover to backup battery, and verify normal system operation during switchover;
- Test backup power endurance: record equipment runtime after power loss to verify rated endurance;
- Test mains restoration: restore mains power, check automatic switchback to main power and battery charging initiation.
10.3 System Functional Commissioning
10.3.1 Issuance and Return Function Commissioning
1. Enroll test user information and assign corresponding permissions;
2. Simulate normal issuance process: identity verification → select firearm → confirm issuance → open door and retrieve gun → close door; check process smoothness and record completeness;
3. Simulate normal return process: identity verification → open door and place gun → system recognition → close door; check return verification accuracy and record completeness;
4. Simulate incorrect and missing return scenarios, checking the system correctly identifies and raises alarm prompts;
5. Test dual-person dual-lock mode, verifying the two-person verification process — door cannot be opened when either person is absent.
10.3.2 Inventory Management Function Commissioning
1. Verify real-time inventory display matches actual inventory;
2. Execute automatic inventory count, generate count report, and verify ledger-inventory consistency;
3. Set inventory threshold and test low-stock warning function;
4. Test inventory query, filtering, and statistics functions.
10.3.3 Permission Management Function Commissioning
1. Test logins with different role accounts, verifying permission scope correctness;
2. Test unauthorized operations, verifying the system intercepts and prompts;
3. Test time-based permissions — attempt operations outside authorized time periods, verifying access is denied;
4. Test personnel add, modify, delete, and permission revocation functions.
10.3.4 Log Management Function Commissioning
1. Perform various operations and check operation logs are completely recorded;
2. Test multi-condition log query and filtering functions;
3. Test log export function, exporting Excel files and checking contents;
4. Verify log deletion and modification resistance properties.
10.4 Networked Integration Testing
10.4.1 Platform Integration Commissioning
1. Configure device networking parameters, ensuring network connectivity between the device and management platform;
2. Add the device on the platform side, verifying device registration and online status;
3. Test data upload: verify real-time upload of device status changes, operation records, and alarm information to the platform;
4. Test command dispatch: dispatch remote door opening, parameter settings, and other commands from the platform side, verifying correct reception and execution by the device;
5. Test video linkage: verify the platform automatically displays on-site camera feed when an alarm is triggered.
10.4.2 Third-Party System Integration Commissioning (Optional)
1. Configure interface parameters according to the integration protocol;
2. Test data exchange accuracy and real-time performance;
3. Test business process linkage, such as integration with OA system approval workflows and police platform data synchronization;
4. Verify integration stability through continuous operation without data loss or connection interruptions.
10.4.3 Network Stability Testing
1. Continuous ping test for 1 hour with packet loss rate ≤1%, latency ≤100ms;
2. Simulate network interruption, testing automatic reconnection; verify local data caching during outage and automatic data resumption after restoration;
3. Test functionality under weak network conditions, confirming no data loss.
10.5 Trial Operation Testing
10.5.1 Continuous Operation Testing
1. Run equipment continuously energized for 72 hours, simulating normal usage scenarios with periodic operational testing;
2. During operation, check system stability — no crashes, reboots, or functional abnormalities;
3. Record equipment operating temperature and power supply heat levels, ensuring they remain within normal range;
4. After 72 hours, calculate operational failure rate; zero failures required.
10.5.2 Stress Testing
1. Perform 100 consecutive door open/close operations, testing lock and system response stability;
2. Batch enroll user data, testing system storage and query performance;
3. Frequently trigger alarms, testing alarm response and recording performance;
4. Verify system stability under high-concurrency operations.
10.5.3 Abnormal Scenario Testing
1. Simulate voltage fluctuations and momentary power interruptions, testing equipment normal operation and data integrity;
2. Simulate high/low temperature environments (when conditions permit), testing equipment environmental adaptability;
3. Simulate electromagnetic interference, testing equipment anti-interference capability;
4. Simulate operator errors, testing system fault tolerance.
10.6 Commissioning Records and Handover
- During the commissioning process, fill in the Equipment Commissioning Record Sheet in detail, recording all test results, parameter configurations, issues, and resolution actions;
- Issues found during commissioning must be promptly rectified, with re-testing after rectification until all items pass;
- After commissioning passes, organize commissioning documentation and conduct operator training for the user;
- Both parties sign the Commissioning Acceptance Confirmation Form, marking the end of commissioning and entering the trial operation period.
11.1 Personnel Operation Precautions
- Equipment operators must receive professional training from the manufacturer, be familiar with equipment operation procedures and safety requirements, and pass assessment before being authorized to operate;
- Operators must strictly follow the unit’s firearm management policies and equipment operation procedures when performing issuance and return operations; unauthorized operation is strictly prohibited;
- Standardize operation during identity verification: for fingerprint verification, place finger flat with moderate pressure; for face recognition, face the camera directly with the full face within the framing guide;
- Open and close the cabinet door gently; slamming, pulling forcefully, or violently impacting the door is strictly prohibited to prevent damage to door bolts, hinges, and sensors;
- Handle firearms and ammunition with care when retrieving and replacing them, placing accurately into corresponding gun positions and compartments; random stacking and impacts are strictly prohibited;
- Storing flammable, explosive, corrosive, or strongly magnetic items inside the cabinet is strictly prohibited; personal items unrelated to firearms and ammunition must not be stored inside;
- If equipment abnormality, malfunction, or alarm occurs during operation, immediately stop operation and promptly report to the administrator and manufacturer technical personnel; self-disassembly and repair are strictly prohibited;
- Use of sharp objects to scratch the touchscreen is strictly prohibited; operating the touchscreen with wet hands is prohibited to prevent water damage;
- The mechanical emergency key shall be kept by designated personnel in a secure location, never carried on person, and used only in emergency situations; usage must be registered and filed after each use.
11.2 Electrical Safety Precautions
- Equipment power supply must use compliant mains electricity with reliable grounding; connection to temporary wiring or non-compliant power strips is strictly prohibited;
- Equipment power supply circuit must be dedicated; sharing a circuit with high-power devices is prohibited to avoid voltage fluctuations affecting equipment operation;
- Unauthorized disassembly of power modules or modification of wiring is strictly prohibited; replacement of fuses or power modules with non-original specification parts is prohibited;
- Regularly inspect power cables for aging, damage, or exposed conductors; replace promptly if any issues are found;
- Disconnect power before cleaning equipment; wiping electrical components with damp cloths is prohibited; washing equipment with water is strictly prohibited;
- Do not pile debris near the equipment; maintain proper ventilation for heat dissipation; covering or blocking ventilation openings is prohibited;
- During thunderstorms, disconnecting equipment power and network cables is recommended to prevent lightning damage;
- The backup battery must not be short-circuited, disassembled, or incinerated; waste batteries must be recycled in accordance with environmental requirements and must not be disposed of casually.
11.3 Network and Data Security Precautions
- When connecting equipment to a unit network, comply with the unit’s network security management policies and implement appropriate network security protection;
- System administrator passwords must be changed regularly, with complexity meeting requirements (combination of letters + numbers + symbols, length ≥8 characters); weak passwords are strictly prohibited;
- Never expose the equipment directly to the public internet; it must be isolated through security devices such as firewalls and network gateways;
- Regularly back up system data, with important data stored offsite to prevent data loss;
- Unauthorized installation of third-party software, modification of system programs, or jailbreaking and cracking of the equipment is strictly prohibited;
- USB drives and other storage devices must be virus-scanned before connection to prevent virus transmission to the equipment system;
- Operation logs, captured images, and other sensitive data must be managed in accordance with confidentiality regulations; unauthorized copying and dissemination are strictly prohibited.
11.4 Environmental and Maintenance Precautions
- The equipment operating environment should remain clean, dry, and well-ventilated, avoiding dusty, humid, and high-temperature conditions;
- Regularly clean dust from the cabinet surface to maintain appearance; use a soft dry cloth for cleaning; use of corrosive cleaners such as gasoline, alcohol, or acetone is strictly prohibited;
- Regularly check the desiccant inside the cabinet (if equipped); replace promptly when depleted;
- During extended periods of non-use, disconnect power, remove batteries, and implement dust and moisture protection measures;
- When moving or relocating equipment, power off first and keep upright; tilting, inverting, or impacting is strictly prohibited;
- Do not attach or hang heavy objects on the cabinet surface; climbing on or leaning against the cabinet is strictly prohibited;
- Regularly check cabinet mounting bolts to prevent loosening, ensuring cabinet stability.
11.5 Emergency Handling Precautions
In case of fire, immediately cut off the power supply and use dry powder fire extinguishers to extinguish the fire. It is strictly prohibited to use water. If the fire is large, evacuate immediately and report the fire alarm;
In case of equipment locking or door failure, contact the manufacturer’s technical personnel for handling. It is strictly prohibited to use violent prying or smashing;
In case of illegal intrusion or violent damage alarms, immediately activate the emergency response plan, notify security personnel to handle the situation, and protect the scene at the same time;
In case of prolonged mains power outage, reduce the number of door opening operations, extend the backup power usage time, and restore power supply as soon as possible;
When mechanical key access is required in an emergency, at least two management personnel must be present, registration records must be kept, and the cause of the fault shall be investigated promptly after the incident.
12 Product Maintenance and Service Specifications
12.1 Routine Maintenance Specifications
12.1.1 Daily Inspection
Perform routine inspection of the equipment at each shift handover and record the operating status:
- Check whether the equipment power supply and network are normal, and whether the indicator lights display correctly;
- Check whether the cabinet door is closed and locked properly, and whether there are any abnormal gaps;
- Check the system interface for any alarm prompts or fault prompts;
- Check the cabinet exterior for damage or deformation, and check the surrounding environment for any abnormalities;
- Fill in the “Equipment Daily Inspection Record Form”.
12.1.2 Weekly Cleaning and Maintenance
Perform equipment cleaning and appearance inspection once a week:
- Wipe the cabinet surface, touch screen, and identification module surfaces with a clean soft cloth to remove dust and stains;
- Clean dust and debris inside the cabinet to keep the interior tidy;
- Check moving parts such as door locks, hinges, and sliding rails to ensure smooth opening and closing without abnormal noise;
- Check whether cables are loose or damaged, and organize cable routing.
12.1.3 Monthly Functional Inspection
Perform a comprehensive functional inspection once a month:
- Test all identity recognition methods including fingerprint, facial recognition, password, and card swiping to ensure they function properly;
- Test all locking mechanisms for proper opening and closing, and check for any jamming;
- Test whether the alarm functions trigger correctly;
- Test whether the backup power switching function operates correctly;
- Check whether the temperature and humidity display is accurate, and inspect for condensation or signs of corrosion inside the cabinet;
- Back up system logs and important data.
12.1.4 Quarterly Deep Maintenance
Perform deep maintenance and performance inspection once per quarter:
- Apply an appropriate amount of lubricating oil to moving parts such as door lock hinges and sliding rails to ensure smooth opening and closing;
- Open the cabinet side covers, clean internal dust, and check whether internal wiring is loose or aged;
- Check whether the grounding connection is reliable and measure the grounding resistance;
- Calibrate the temperature/humidity sensor and vibration sensor parameters;
- Check the battery capacity and perform charge/discharge maintenance;
- Check the cabinet fixing bolts and re-tighten them.
12.2 Scheduled Maintenance Plan
| Maintenance Cycle | Maintenance Item | Maintenance Requirements | Responsible Person |
|---|---|---|---|
| Daily | Appearance and status inspection | No alarms, no damage, normal operation | Duty officer |
| Weekly | Cleaning and appearance inspection | Clean and dust-free, components intact | Officer |
| Monthly | Full functional testing | All functions normal and usable | Officer + Technician |
| Quarterly | Deep maintenance and calibration | Component lubrication, parameter calibration, wiring tightening | Manufacturer technician |
| Annually | Comprehensive inspection and battery test | Full performance inspection, battery capacity test | Manufacturer technician |
| Every 3 years | Battery replacement | Replace backup battery | Manufacturer technician |
12.3 Key Component Maintenance Points
12.3.1 Lock Maintenance
- Keep the lock clean and prevent dust and debris from entering the lock cylinder;
- It is strictly prohibited to add lubricating oil, pencil lead, or other substances into the lock cylinder to prevent clogging;
- Mechanical lock keys should insert and remove smoothly; if jamming occurs, a special graphite lubricant may be used;
- For electronic locks, regularly check the wiring terminals to prevent loosening;
- If the lock operates poorly or produces abnormal noise, investigate the cause promptly. Violent operation is strictly prohibited.
12.3.2 Biometric Recognition Module Maintenance
- Keep the fingerprint sensor and facial recognition camera clean, wiping gently with a clean soft cloth. It is strictly prohibited to scratch with fingers or hard objects;
- Avoid direct sunlight on the recognition window to prevent performance degradation;
- It is strictly prohibited to rinse or soak the recognition module with liquid;
- When stains are present on the module surface, wipe with a soft cloth dampened with a small amount of clean water and dry immediately.
12.3.3 Battery Maintenance
- The battery should be kept in a fully charged state. When powered by mains power for extended periods, perform a discharge test once a month;
- Avoid deep discharge of the battery; restore charging promptly when the battery is low;
- The battery storage environment temperature should be 0–30°C, avoiding high or low temperature environments;
- Regularly check the battery appearance for bulging or leakage; replace immediately if any abnormality is found;
- The battery service life is generally 3 years. Replace promptly upon expiry to ensure emergency power supply capability.
12.3.4 Cabinet Body and Structure Maintenance
- Avoid hard object impacts and scratches on the cabinet surface. Repair damaged powder coating promptly to prevent corrosion;
- Regularly check structural components such as welds, hinges, and bolts for looseness, cracking, or corrosion;
- Regularly apply lubricating grease to hinges to ensure smooth opening and closing and prevent rust;
- Regularly check sealing strips for aging or detachment to maintain sealing performance.
12.4 Repair Service Specifications
12.4.1 Repair Request Procedure
- When equipment malfunctions, the operator immediately stops use and records the fault phenomenon and fault time;
- Report to the unit administrator, who will perform initial troubleshooting of simple faults. If unresolved, contact the manufacturer’s after-sales service;
- Call the manufacturer’s technical support hotline, providing the equipment model, serial number, fault description, user unit, and contact information;
- The manufacturer’s technical personnel provide telephone guidance for troubleshooting. If remote resolution is not possible, on-site repair will be arranged;
- After repair is completed, fill in the repair record and both parties sign for confirmation.
12.4.2 Repair Safety Requirements
- Repair work must be performed by manufacturer-authorized professional technical personnel. It is strictly prohibited for non-professionals to disassemble or repair the equipment;
- Before disassembly for repair, the power supply and battery must be disconnected to ensure power-off operation;
- Wear an anti-static wrist strap during repair to prevent static electricity from damaging electronic components;
- Replacement parts must be genuine factory parts. The use of substitute or inferior parts is strictly prohibited;
- Take proper protective measures during repair to prevent tools or parts from falling into the cabinet and causing safety hazards;
- After repair is completed, a comprehensive functional test must be performed. The equipment may only be delivered after confirming the fault is eliminated and the equipment operates normally.
12.4.3 Warranty Policy
- The complete product is covered by a free 1-year warranty, with core components warranted for 2 years, calculated from the date of acceptance;
- During the warranty period, faults not caused by human damage are repaired free of charge with free replacement parts;
- Damage caused by human factors, force majeure, or unauthorized disassembly or modification is not covered under warranty and will be repaired at cost;
- After the warranty period, lifetime repair service is provided, charging only parts cost and on-site service fees;
- The manufacturer provides a 7×24-hour technical support hotline. General faults are responded to within 2 hours, on-site service within 24 hours for local provinces and within 48 hours for other provinces.
13 Common Product Faults and Solutions
13.1 Power Supply and Power-On Faults
| Fault Phenomenon | Possible Causes | Solutions |
|---|---|---|
| Device completely unpowered, screen not lit, no response | 1. Mains power outage or no power at outlet<br>2. Power plug loose or detached<br>3. Power switch not turned on<br>4. Fuse blown<br>5. Power module damaged | 1. Check mains power supply, restore power<br>2. Re-insert the power plug firmly<br>3. Turn on the power switch at the rear of the device<br>4. Replace with same specification fuse<br>5. Contact manufacturer to replace power module |
| Device repeatedly restarts after power-on | 1. Unstable input voltage<br>2. Power module fault<br>3. Mainboard short circuit<br>4. Battery fault | 1. Measure mains voltage, configure a voltage stabilizer<br>2. Replace power module for testing<br>3. Power off and check mainboard for short circuit, contact manufacturer for repair<br>4. Disconnect battery for testing; if faulty, replace battery |
| Backup power not working after power outage | 1. Battery depleted or damaged<br>2. Battery wiring loose<br>3. Power management module fault<br>4. Battery switch not turned on | 1. Charge and test; if still not working, replace battery<br>2. Re-tighten battery terminal connections<br>3. Contact manufacturer to repair power management module<br>4. Turn on the battery switch |
| Device automatically powers off during operation | 1. Poor mains contact, intermittent power<br>2. Device overheat protection<br>3. Power module fault<br>4. Internal short circuit protection | 1. Check power supply lines and outlets, tighten wiring<br>2. Check if vents are blocked, clean dust, improve ventilation and cooling<br>3. Replace power module<br>4. Power off and check for internal short circuits, contact manufacturer |
| Frequent low battery alarms | 1. Battery aging, insufficient capacity<br>2. Frequent mains power outages<br>3. Charging circuit fault, battery not fully charging<br>4. Abnormal increase in device power consumption | 1. Replace the battery<br>2. Improve power supply stability, configure UPS<br>3. Check charging circuit, contact manufacturer for repair<br>4. Check for module short circuits or abnormal heating |
13.2 Identity Recognition Faults
| Fault Phenomenon | Possible Causes | Solutions |
|---|---|---|
| Fingerprint recognition fails repeatedly | 1. Finger too dry, too wet, or too dirty<br>2. Fingerprint sensor has stains or dust<br>3. Incorrect placement or insufficient pressure<br>4. Fingerprint not enrolled or damaged<br>5. Fingerprint module fault | 1. Clean and dry fingers, then retry<br>2. Wipe the sensor with a clean soft cloth<br>3. Place finger flat, covering the entire sensing area, with moderate pressure<br>4. Re-enroll the fingerprint<br>5. Contact manufacturer to service the fingerprint module |
| Facial recognition fails | 1. Face off-center from camera, not within framing<br>2. Lighting too bright, too dim, or backlit<br>3. Mask, sunglasses, or hat covering the face<br>4. Face database information corrupted<br>5. Camera fault | 1. Adjust position, face the camera directly<br>2. Adjust lighting, avoid strong backlight, enable fill light<br>3. Remove obstructions, expose the full face<br>4. Re-enroll facial information<br>5. Contact manufacturer to service the camera |
| IC card swipe no response | 1. Card damaged or demagnetized<br>2. Reading distance too far<br>3. Card reader surface dirty<br>4. Card reader wiring loose<br>5. Card not authorized | 1. Try a different card for testing<br>2. Place card flush against the reader surface<br>3. Clean the card reader surface<br>4. Check card reader wiring, re-tighten<br>5. Authorize the card in the system |
| Password verification failed | 1. Incorrect password entered<br>2. Wrong case or number key pressed<br>3. Account locked<br>4. Password has been changed | 1. Confirm password and re-enter<br>2. Check touch keyboard, enter accurately<br>3. Wait for lockout period to end or have administrator unlock<br>4. Contact administrator to reset password |
| Dual-person verification cannot open door | 1. Second person did not verify within required time<br>2. One person lacks permission<br>3. Verification mode set incorrectly<br>4. System logic fault | 1. Both persons verify consecutively, interval not exceeding 30 seconds<br>2. Check permission configuration for both persons<br>3. Confirm system is set to dual-person dual-lock mode<br>4. Restart device, contact manufacturer for troubleshooting |
13.3 Lock and Door Opening/Closing Faults
| Fault Phenomenon | Possible Causes | Solutions |
|---|---|---|
| Door will not open after verification passes | 1. Electronic lock fault<br>2. Lock wiring loose or broken<br>3. Door bolt jammed<br>4. Relay fault<br>5. Mechanical structure seized | 1. Use mechanical emergency key to open, service the electronic lock<br>2. Check lock wiring, re-tighten<br>3. Gently push then pull the door, try repeatedly to release jamming<br>4. Replace relay<br>5. Contact manufacturer for on-site repair |
| Door will not lock after closing | 1. Door not fully closed, door magnet not triggered<br>2. Foreign object stuck in latch<br>3. Electronic lock fault<br>4. Door body deformed, hinge sagging | 1. Push door firmly, confirm fully closed<br>2. Clean foreign objects from latch area<br>3. Service the electronic lock<br>4. Adjust hinges, correct door alignment |
| Electronic gun lock cannot unlock | 1. Gun lock wiring loose<br>2. Gun lock jammed, firearm not placed correctly<br>3. Gun lock motor damaged<br>4. Control signal fault | 1. Check gun lock wiring, reconnect<br>2. Adjust firearm position, re-place properly<br>3. Replace electronic gun lock<br>4. Check control board and wiring |
| Drawer will not open | 1. Drawer lock fault<br>2. Drawer slide rail jammed<br>3. Internal items caught<br>4. Unauthorized unlock attempt | 1. Service the drawer electronic lock<br>2. Gently shake the drawer to release jamming<br>3. Organize items inside the drawer<br>4. Confirm operation permission, follow procedure to unlock |
| Abnormal noise or jamming when opening door | 1. Hinges lack lubrication, rusted<br>2. Door body rubbing against cabinet<br>3. Door bolt dry<br>4. Hinge screws loose | 1. Apply lubricating grease to hinges<br>2. Adjust door gap to avoid friction<br>3. Clean door bolt, apply a small amount of lubricating grease<br>4. Tighten hinge screws |
13.4 System and Function Faults
| Fault Phenomenon | Possible Causes | Solutions |
|---|---|---|
| Touch screen unresponsive, offset touch | 1. Screen surface dirty or wet<br>2. System crashed<br>3. Touch driver fault<br>4. Touch screen hardware damaged | 1. Clean and dry the screen<br>2. Restart the device<br>3. Restore factory settings or upgrade firmware<br>4. Contact manufacturer to replace touch screen |
| System frozen, interface stuck | 1. System program anomaly<br>2. Insufficient memory<br>3. Hardware fault<br>4. Power fluctuation | 1. Power off and restart the device<br>2. Clear system logs and redundant data<br>3. Contact manufacturer to service the mainboard<br>4. Stabilize power supply, configure voltage stabilizer |
| RFID cannot detect firearm in position | 1. Firearm tag damaged or detached<br>2. Antenna wiring loose<br>3. RFID reader fault<br>4. Firearm placed at incorrect position | 1. Check tag; if damaged, replace and re-bind<br>2. Check antenna feeder cable, reconnect<br>3. Service the RFID reader<br>4. Place the firearm at the bottom of the corresponding gun slot |
| Abnormal temperature/humidity display | 1. Sensor wiring loose<br>2. Sensor damaged<br>3. System parameter drift<br>4. Drastic environmental changes | 1. Check sensor wiring<br>2. Replace temperature/humidity sensor<br>3. Re-calibrate sensor parameters<br>4. Observe after stabilizing environment |
| No alarm or frequent false alarms | 1. Alarm parameters set incorrectly<br>2. Sensor sensitivity too high/low<br>3. Sensor fault<br>4. Alarm speaker damaged | 1. Adjust alarm threshold and sensitivity<br>2. Calibrate sensor sensitivity to appropriate level<br>3. Replace faulty sensor<br>4. Replace sound/light alarm device |
13.5 Network and Networking Faults
| Fault Phenomenon | Possible Causes | Solutions |
|---|---|---|
| Network connection failed, showing offline | 1. Network cable loose or disconnected<br>2. IP address set incorrectly<br>3. Switch or router fault<br>4. Network firewall blocking<br>5. Network card fault | 1. Re-plug network cable, check link<br>2. Verify IP, subnet mask, and gateway parameters<br>3. Check network equipment, restart switch<br>4. Open device communication ports and permissions<br>5. Contact manufacturer to service network card |
| Data upload delay, packet loss | 1. Insufficient network bandwidth<br>2. High network latency, severe packet loss<br>3. Server load high<br>4. Device network parameters abnormal | 1. Increase network bandwidth<br>2. Troubleshoot network link faults, optimize network<br>3. Check platform server status<br>4. Restart device network module |
| Platform cannot remotely control device | 1. Network unreachable<br>2. Device registration offline<br>3. Insufficient permissions<br>4. Protocol mismatch | 1. Troubleshoot network connection<br>2. Re-register device, check device ID<br>3. Confirm platform account operation permissions<br>4. Verify communication protocol version, upgrade to match |
| 4G network cannot connect | 1. SIM card arrears or damaged<br>2. Signal too weak<br>3. 4G module fault<br>4. APN parameters set incorrectly | 1. Recharge account, test with replacement SIM card<br>2. Adjust antenna position, improve signal<br>3. Service the 4G module<br>4. Configure APN parameters correctly |
13.6 General Troubleshooting Procedure
When an equipment fault occurs, it is recommended to troubleshoot step by step as follows, which can resolve most simple faults:
- Observe the phenomenon: Carefully record the fault description, occurrence time, frequency, and whether there are accompanying abnormal noises, odors, or error codes;
- Restart test: Most software-related and intermittent faults can be resolved by restarting the device. Disconnect power for 30 seconds and then reconnect;
- Visual inspection: Check whether the power supply, network cable, and wiring are loose, and whether the device has damage, water ingress, or foreign objects;
- Parameter verification: Check whether system settings, network parameters, and permission configuration are correct;
- Replacement testing: When conditions permit, replace with known-good components for testing to quickly locate the faulty part;
- Record and report: For unresolved faults, record detailed information and contact the manufacturer’s technical support.
14 Product FAQ Manual
14.1 Product Basics
Q1: What standards does this intelligent gun/ammunition cabinet comply with? Is there a test report?
A: This product strictly complies with the GA 1051-2013 “Special Security Cabinet for Firearms and Ammunition” public security industry standard, as well as relevant standards including GB/T 28181 and GA 1016. The product has passed testing at the Quality Supervision and Inspection Center for Special Police Equipment of the Ministry of Public Security, with complete CMA/CNAS test reports. Copies stamped with the manufacturer’s official seal are provided with the delivery; originals are available for review.
Q2: Can the product be customized? For example, dimensions, number of gun slots, color?
A: Full parameter customization is supported. The number of gun slots, long/short gun ratio, and ammunition drawer quantity can be customized according to the user’s actual requirements. Cabinet dimensions and colors (military green, dark gray, black, etc.) can be customized. Functional modules can also be customized, such as alcohol detection, 4G connectivity, dehumidification and heating. Customized products also comply with national standards, ensuring regulatory compliance.
Q3: What is the product service life?
A: The cabinet mechanical structure design life is ≥15 years, electronic modules design life is ≥5 years, and battery service life is ≥3 years. Under normal use and regular maintenance conditions, the entire cabinet can operate stably for over 10 years. The manufacturer provides lifetime maintenance services, and aging components can be replaced or upgraded.
Q4: What is the difference between an intelligent gun/ammunition cabinet and an ordinary safe?
A: The core differences lie in management capability and security level:
- Standards: Gun/ammunition cabinets comply with the dedicated GA 1051-2013 standard, with protection levels far exceeding ordinary safes;
- Functions: Ordinary safes only provide storage; gun/ammunition cabinets feature identity authentication, presence detection, alarm linkage, log management, and other intelligent functions;
- Management: Gun/ammunition cabinets achieve full digital lifecycle management of firearms and ammunition, complying with firearms management regulations, while ordinary safes cannot meet regulatory requirements;
- Structure: Gun/ammunition cabinets have dedicated gun racks, gun locks, and ammunition compartments adapted to firearm and ammunition storage needs.
14.2 Installation and Deployment
Q5: What conditions are required for installation? Can we install it ourselves?
A: Installation requires a solid and level floor, 220V mains power, grounding conditions, and a network interface for networked models. Self-installation by users is not recommended. The equipment is heavy, wiring is complex, and commissioning is professional; installation and commissioning should be performed by the manufacturer’s professional technicians to ensure proper installation, normal functionality, and safe operation. The manufacturer provides on-site installation services.
Q6: How many holes need to be drilled for installation? Will it damage the floor?
A: A standard single cabinet requires 4 M16 expansion bolt holes, 120mm deep, causing minimal damage to the floor. After installation, the cabinet can also be removed, and the holes can be patched with cement. If the installation location has special requirements, the fixing scheme can be adjusted according to site conditions, such as counterweight fixing (no drilling).
Q7: The equipment is too heavy, and the corridor is narrow with steps. How can it be moved in?
A: The manufacturer’s installation team has extensive on-site handling experience and will prepare handling tools and develop a handling plan according to site conditions. For narrow corridors, the packaging can be disassembled and moved in stages. For steps, stair-climbing equipment can be used to ensure the equipment is safely positioned without damaging the equipment or the building.
Q8: How long does installation take?
A: Standard single-cabinet installation and commissioning takes approximately 4–6 hours, including cabinet fixing, wiring, commissioning, and training. Multi-cabinet combinations and system integration projects depend on scale, generally completing delivery within 1–3 days.
14.3 Function and Usage
Q9: Do two people have to open the door? Can single-person access be configured?
A: The system supports flexible configuration, including single-person mode, dual-person mode, and multi-person mode. According to public security firearms management regulations, dual-person dual-lock is generally required, and dual-person mode is recommended. Emergency single-person permissions can be configured for special emergency scenarios, with strict approval and recording mechanisms.
Q10: What happens during a power outage? Can the door still be opened?
A: The device has a built-in backup battery that automatically switches to battery power during a power outage, supporting ≥100 normal door openings and ≥12 hours of standby. If the battery is also depleted, two mechanical emergency keys can be used to open the door. All operation records during the power outage are preserved and will not be lost.
Q11: If the system breaks down or crashes, will the door be unable to open?
A: No. The device is equipped with a mechanical emergency unlocking device. Even if the system completely fails or power is lost, the cabinet door can be opened using two mechanical emergency keys, ensuring firearms and ammunition can be accessed in emergencies. The mechanical keys are stored separately by two persons, in accordance with management regulations.
Q12: Will firearms and ammunition rust inside? What about humid weather?
A: The cabinet features a sealed moisture-proof structure. The standard model is equipped with temperature and humidity monitoring, with an optional intelligent dehumidification and heating module that automatically regulates the internal temperature and humidity, maintaining a suitable range of 40%–60% RH to prevent corrosion. It is recommended to select the dehumidification module in humid southern regions.
Q13: Can the product integrate with our existing firearms management system?
A: Yes. The product provides standard API interfaces and an SDK development kit, supporting integration with mainstream police platforms, firearms management systems, and OA approval systems. The manufacturer’s technical team can provide integration support and develop custom solutions based on the user’s system protocols.
14.4 Security and Confidentiality
Q14: Where are fingerprint and facial recognition data stored? Can they be leaked?
A: User biometric information is encrypted and stored locally on the device’s main control chip and is not uploaded to the cloud, in compliance with data security and confidentiality requirements. All data transmitted over the network is encrypted, with strict access control, ensuring user information cannot be leaked.
Q15: Can hackers remotely control the door to open?
A: No. The system has multiple layers of network security protection:
- Deployed on an intranet, not directly exposed to the public internet;
- Mutual identity authentication between the device and platform; unauthorized devices cannot connect;
- All commands are encrypted in transmission, preventing tampering and forgery;
- Remote door opening requires multi-level approval and authorization; it cannot be operated by arbitrary accounts;
- The system uses an embedded Linux operating system with low virus risk and high security.
Q16: Can operation logs be deleted or modified?
A: Operation logs use a special storage mechanism that only allows addition, querying, and export. They cannot be deleted or modified, ensuring data authenticity and traceability, and meeting audit requirements. Only the super administrator has export permission; delete and modify functions are completely disabled.
14.5 After-Sales and Maintenance
Q17: What is the warranty period? How quickly can on-site service arrive?
A: The complete unit has a 1-year free warranty, core components are warranted for 2 years, with lifetime maintenance. On-site service within 24 hours for local provinces and within 48 hours for other provinces. Remote guidance is provided for urgent faults, with a 7×24-hour technical support hotline.
Q18: Can gun positions be added or functions upgraded later?
A: Yes. The product features modular design, allowing future expansion of gun positions, addition of auxiliary cabinets, and upgrades to functional modules such as facial recognition, alcohol detection, and networking functions. No need to replace the entire cabinet, protecting the user’s investment.
Q19: Do batteries need frequent replacement? Is replacement expensive?
A: Under normal use, batteries should be replaced approximately every 3 years, depending on the usage environment and charge/discharge frequency. Original batteries are reasonably priced and replacement is simple. The manufacturer can provide on-site replacement, or the user can purchase batteries of the same specification for self-replacement.
Q20: What if the equipment needs to be relocated or moved?
A: For relocation, it is recommended to contact the manufacturer’s technical personnel for on-site service, including professional disassembly, handling, re-installation, and commissioning to ensure the equipment remains intact and functions properly. Self-relocation can easily cause component damage and wiring confusion, and may affect the warranty.
15 Product Acceptance Standards and Procedures
15.1 Acceptance Basis
Equipment acceptance strictly follows the following basis:
- GA 1051-2013 “Special Security Cabinet for Firearms and Ammunition”
- Product procurement contract and technical agreement
- Product factory technical standards and instruction manual
- National and local firearms management regulations
15.2 Acceptance Organization
- Acceptance team composition: An acceptance team is formed by personnel from the user unit’s management department, security department, and technical department, with the manufacturer’s project manager and technical personnel providing support;
- Acceptance prerequisites: Equipment installation and commissioning completed, trial operation ≥7 days, stable operation, normal functions, and complete documentation;
- Acceptance preparation: The manufacturer prepares acceptance documents and test tools; the user unit prepares the acceptance site and supporting personnel.
15.3 Acceptance Content and Standards
15.3.1 Appearance and Structure Acceptance
| Acceptance Item | Acceptance Standard | Acceptance Method |
|---|---|---|
| Cabinet appearance | Surface smooth and flat, powder coating even, no scratches, dents, deformation, or corrosion | Visual inspection, tactile check |
| Dimensional deviation | External dimension deviation ≤±5mm, diagonal deviation ≤4mm | Tape measure |
| Door gap | Door gap even, ≤0.2mm | Feeler gauge measurement |
| Cabinet levelness | Cabinet vertical, tilt ≤1° | Spirit level measurement |
| Fixing firmness | Expansion bolts tightened, cabinet without wobble or displacement | Push test, check bolts |
| Door opening/closing | Opening angle ≥90°, smooth operation, no jamming or abnormal noise | Manual open/close test |
| Internal structure | Gun racks, drawers, and shelves installed firmly, neatly arranged, no looseness | Visual inspection, manual stability test |
| Nameplates and signs | Product nameplate and warning signs complete and legible | Visual inspection |
15.3.2 Hardware Performance Acceptance
| Acceptance Item | Acceptance Standard | Acceptance Method |
|---|---|---|
| Plate thickness | Cabinet body steel ≥6mm, door steel ≥10mm | Vernier caliper measurement (or review material test report) |
| Lock anti-destruction | Anti-technical opening ≥10min, anti-forced destruction ≥30min | Review third-party test report |
| Lock service life | Electronic lock opening/closing ≥100,000 cycles | Review test report, spot test 100 cycles without fault |
| Backup power endurance | Normal operation ≥12 hours after power failure, ≥100 door openings | Power failure test, record endurance time |
| Grounding resistance | ≤4Ω | Ground resistance tester measurement |
| Insulation performance | Insulation resistance ≥100MΩ | Megger measurement |
15.3.3 System Function Acceptance
(1) Identity Authentication Functions
- Fingerprint recognition: Recognition accuracy ≥99%, recognition time ≤1s, liveness detection supported;
- Facial recognition: Recognition accuracy ≥99.5%, recognition time ≤1.2s, liveness detection supported;
- Password authentication: Multi-level passwords supported, incorrect attempt lockout mechanism functioning;
- Dual-person dual-lock: Both persons must verify to open the door; cannot be opened by one person alone;
- Alcohol detection (optional): Accurate detection, exceeding threshold prohibits issuance.
(2) Firearm and Ammunition Management Functions
- Presence detection: Real-time accurate firearm present/absent status, 100% recognition accuracy;
- Issuance and return: Smooth process, automatic recording, accurate return verification;
- Inventory management: Real-time accurate inventory display, correct automatic inventory count;
- Permission management: Multi-level permission control effective, unauthorized operations blocked;
- Log recording: Complete operation recording, complete content, tamper-proof.
(3) Alarm Linkage Functions
- Illegal door opening alarm: Accurate triggering, normal sound/light alarm, complete records;
- Vibration/destruction alarm: Appropriate sensitivity, normal triggering;
- Overdue return alarm: Automatic reminder and alarm on timeout;
- Temperature/humidity exceedance alarm: Accurate threshold, timely alarm;
- Alarm linkage: Alarm information uploaded to platform normally, push notifications sent.
(4) Networking and Platform Functions
- Device online stable, real-time accurate data upload;
- Platform remote command issuance and execution normal;
- Platform functions and interface comply with contract requirements;
- Data statistics and report generation normal.
15.3.4 Documentation Acceptance
The manufacturer must submit the following complete documents upon acceptance:
1. Product certificate of conformity — 1 copy;
2. Ministry of Public Security test report copy (stamped with official seal) — 1 copy;
3. Product instruction manual — 1 copy;
4. Installation and commissioning record — 1 copy;
5. System parameter configuration table — 1 copy;
6. Equipment warranty card — 1 copy;
7. Spare parts list — 1 copy;
8. Training record — 1 copy.
15.4 Acceptance Procedure
- Acceptance application: After completing installation, commissioning, and trial operation, the manufacturer submits the acceptance application and acceptance documents to the user unit;
- Acceptance preparation: The user unit organizes the acceptance team, determines the acceptance schedule, and the manufacturer prepares the test environment and tools;
- On-site acceptance: Test and inspect items one by one according to the acceptance content, and fill in the acceptance record form;
- Issue rectification: For non-conforming items found during acceptance, the manufacturer rectifies within a specified period and re-inspects after rectification;
- Acceptance conclusion: After all items pass, the acceptance team issues the acceptance conclusion;
- Sign-off and delivery: Both parties sign the “Equipment Acceptance Certificate,” the equipment is formally delivered for use, and the warranty period begins.
15.5 Acceptance Determination Rules
- Qualified determination: All acceptance items fully comply with the standard requirements, and the acceptance is determined as qualified;
- General non-conformance: Minor defects in non-core functions or appearance that do not affect safety or primary use; qualified after rectification;
- Serious non-conformance: Core safety indicators or main functions not meeting standards, affecting safe use; mandatory rectification and re-inspection required. If re-inspection still fails, the acceptance is determined as unqualified;
- For equipment that fails acceptance, the manufacturer must repair or replace unconditionally at its own cost until qualified.
16 SEO Keyword Optimization System
16.1 Keyword Classification System
16.1.1 Core Primary Keywords
Intelligent gun management cabinet, intelligent ammunition management cabinet, gun/ammunition cabinet, ammunition cabinet, intelligent gun/ammunition cabinet, special security cabinet for firearms and ammunition
16.1.2 High-Conversion Long-Tail Keywords
Intelligent gun management cabinet manufacturer, intelligent ammunition management cabinet price, public security dedicated intelligent gun cabinet, military intelligent ammunition cabinet, dual-person dual-lock intelligent gun cabinet, RFID intelligent gun cabinet, facial recognition gun cabinet, intelligent gun/ammunition integrated cabinet, intelligent gun cabinet installation and commissioning, gun cabinet acceptance standards
16.1.3 Industry Traffic Keywords
Firearm and ammunition storage cabinet, police gun cabinet, military gun cabinet, gun safety management cabinet, digital gun cabinet, networked intelligent gun cabinet, intelligent gun cabinet, intelligent ammunition cabinet, gun vault intelligent management system, gun cabinet GA1051 standard
16.1.4 Brand-Specific Keywords
Lain intelligent gun cabinet, Guangdong Lain gun management cabinet, Lain intelligent ammunition cabinet, Lain intelligent gun/ammunition integrated cabinet, Lain gun cabinet manufacturer, Guangzhou Lain intelligent storage equipment
16.1.5 Dropdown/Related Search Keywords
How much does an intelligent gun cabinet cost, which brand of intelligent gun cabinet is best, how to install an intelligent gun cabinet, what standards does a gun cabinet comply with, how to maintain a gun cabinet daily, common faults of intelligent gun cabinets, what documents are needed for gun cabinet acceptance, intelligent gun cabinet wiring methods
16.2 SEO Optimization Tag System
16.2.1 Page Core Optimization Tags
- Page topic: Intelligent gun (ammunition) management cabinet installation, wiring, and commissioning manual
- Core positioning: Professional-grade intelligent gun storage equipment full-process technical guidance document
- Target audience: Equipment managers of public security, military, and escort units, security engineering contractors, and operation and maintenance technicians
16.2.2 Title Tag
Intelligent Gun Management Cabinet Installation and Commissioning Manual_Intelligent Ammunition Cabinet Wiring Tutorial_Gun Cabinet Acceptance Standards – Guangdong Lain Intelligent Equipment Co., Ltd.
16.2.3 Meta Keywords
Intelligent gun management cabinet, intelligent ammunition management cabinet, intelligent gun cabinet installation and wiring, gun cabinet commissioning manual, gun cabinet acceptance standards, GA1051 gun cabinet, dual-person dual-lock gun cabinet, Guangdong Lain gun cabinet
16.2.4 Meta Description
Guangdong Lain Intelligent Equipment Co., Ltd. provides the complete version of the intelligent gun (ammunition) management cabinet installation, wiring, and commissioning manual, covering product introduction, technical parameters, installation specifications, wiring standards, commissioning procedures, fault troubleshooting, and acceptance standards in full, in compliance with the GA1051-2013 standard. Professional and detailed, it can be directly used for construction guidance and acceptance reference.
16.2.5 H1 Tag
Intelligent Gun (Ammunition) Management Cabinet Installation, Wiring, and Commissioning Manual
16.2.6 H2 Tags
- Intelligent Gun Management Cabinet Product Introduction and Working Principle
- Intelligent Ammunition Cabinet Composition Structure and Technical Parameters
- Intelligent Gun Cabinet Functional Features and Application Scenarios
- Intelligent Gun Management Cabinet Installation Specifications and Construction Process
- Intelligent Ammunition Cabinet Wiring Standards and Module Wiring Methods
- Intelligent Gun Cabinet System Commissioning Steps and Verification Methods
- Gun Cabinet Maintenance, Common Fault Solutions
- Intelligent Gun Management Cabinet Acceptance Standards and Procedures
16.2.7 Internal Link Optimization Tags (Natural Anchor Text Integration)
Core anchor texts:
- Intelligent gun management cabinet
- Intelligent ammunition management cabinet
- Intelligent gun cabinet
- Gun/ammunition cabinet
Long-tail anchor texts:
- Dual-person dual-lock intelligent gun cabinet
- RFID intelligent gun management cabinet
- Intelligent gun cabinet installation and commissioning
- Gun cabinet technical parameters
- GA1051 standard gun cabinet
Related anchor texts:
- Confidential storage equipment
- Intelligent security storage equipment
- Gun safety management system
- Special security cabinet for firearms and ammunition
- Intelligent storage management equipment
17 Contact Information and Copyright Notice
17.1 Contact Information
- Manufacturer: Guangdong Lain Intelligent Equipment Co., Ltd.
- Service hotline: +86 13538869979 (WhatsApp available)
- Technical support: +86 13538869979
- Company address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
- Official website: gdlain.com
17.2 Copyright Notice
The copyright of this document is owned by Guangdong Lain Intelligent Equipment Co., Ltd. and is protected by national copyright law.
No unit or individual may copy, reproduce, modify, excerpt, disseminate, or commercially utilize all or part of this document without the written authorization of the company, nor publish it on any other platform in any form.
For reprinting or citing content from this document, the source “Guangdong Lain Intelligent Equipment Co., Ltd.” must be indicated, the complete copyright information must be retained, and the content may not be used for commercial purposes.
Violators of the above statement will be held legally liable by the company in accordance with the law.
If the content of this document changes due to product technology upgrades, no separate notice will be provided. The company reserves the right of final interpretation.