Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

KITOZER Closed-Loop Water-Cooled Integrated Cabinet

KITOZER Closed-Loop Water-Cooled Integrated Cabinet Quotation List

2. Project Requirement Description

The client requires closed-loop water-cooled integrated cabinets for scenarios where coolant cleanliness is critical and no exposed water circuits are permitted on equipment. The key requirements are as follows:

  • A fully sealed, independent water circulation loop that completely isolates the internal coolant from external cooling water
  • Protection of internal water circuits from contamination, scaling, and corrosion
  • Suitability for high-value precision IT equipment heat dissipation needs
  • Compliance with stringent coolant purity standards

3. System Composition Introduction

The closed-loop water-cooled integrated cabinet consists of the following major components:

  • Cabinet Enclosure – reinforced 42U standard rack housing all cooling and power components
  • Closed-Loop Coolant Distribution Unit (CDU) – the core cooling host with plate heat exchanger isolation
  • Primary-Side Heat Exchange Loop – connects to external cooling water source (building chilled water, cooling tower, chiller, etc.)
  • Secondary-Side Closed Circulation Loop – deionized pure water circuit dedicated to cooling the IT equipment
  • Cold Plate / Rear Door Heat Exchanger Unit – micro-channel rear door heat exchanger installed inside the cabinet
  • Power Distribution Module – UPS plus intelligent PDU for high-density power supply
  • Intelligent Monitoring & Safety Protection Module – full-parameter monitoring with alarm and protection functions
  • Plate Heat Exchanger – built-in to achieve complete isolation between the two water loops

4. Core Product Specifications & Parameters

Parameter Category Specification
Cooling Capacity 10kW ~ 40kW per cabinet, heat exchange efficiency ≥93%, supports multi-cabinet parallel expansion
Primary Side (External Water) Supply water temperature 25℃~35℃, pressure 0.2~0.4MPa, conventional cooling water quality
Secondary Side (Internal Water) Deionized pure water, supply temperature 18℃~28℃, accuracy ±0.5℃, conductivity ≤10μS/cm
Circulation Parameters Built-in stainless steel multistage centrifugal pump, head 15~30m, adjustable flow, with pressurized expansion tank
Cabinet Dimensions 42U standard rack, 600×1200×2000mm, reinforced structure, static load ≥2000kg
Safety Protection Dual-path leak detection, over-temperature protection, over-pressure protection, low-flow protection, conductivity monitoring
Monitoring System 7×24-hour monitoring of temperature, pressure, and flow parameters on both water loops, automatic fault alarm and protection

5. Core Functions & Features of Products

  • Dual-Loop Isolated Heat Exchange – plate heat exchanger achieves complete isolation between internal and external water loops; internal loop uses deionized pure water, ensuring clean equipment water circuits
  • Precise Temperature Control – secondary-side water temperature is precisely controlled with minimal fluctuation, ensuring stable operating temperature for precision equipment
  • Multiple Safety Protections – full-parameter monitoring and protection for pressure, temperature, flow, liquid level, and conductivity, ensuring safe system operation
  • Automatic Pressure Stabilization & Water Replenishment – built-in expansion tank and automatic water supply unit maintain secondary-side pressure stability, no manual refilling required
  • Intelligent Operation & Maintenance Management – full-parameter visualization, automatic fault diagnosis, automatic data recording, remote management support
  • Anti-Corrosion & Anti-Scaling – closed internal circulation with deionized water eliminates pipeline scaling and corrosion, extending equipment service life

6. Core Advantages of The Solution

  • Equipment Protection – closed pure-water circulation prevents impurities, scale, and corrosion from damaging high-value IT equipment, extending equipment lifespan
  • Low Maintenance Burden – internal loop is maintenance-free; only periodic water quality testing is required, reducing maintenance workload by 70% compared to open-loop systems
  • Stable Performance – stable internal loop parameters unaffected by external water quality or pressure fluctuations, delivering consistent cooling performance
  • Extended Service Life – reduced corrosion and scaling on piping and heat exchange components extends overall system lifespan by more than 30% compared to open-loop systems
  • High-End Application Suitability – ideal for AI servers, precision instruments, medical equipment, scientific research equipment, and other high-value precision equipment scenarios

7. Manufacturer Strength Introduction

KITOZER is the proprietary brand of Guangzhou Lai’an Intelligent System Development Co., Ltd., founded in 2002. The company is a certified high-tech enterprise holding ISO 9001, ISO 14001, and ISO 45001 certifications. As a manufacturer, KITOZER performs complete quality inspection on every product before shipment, ensuring reliable and consistent quality for all international customers.

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Closed-Loop Water-Cooled Cabinet Enclosure KTZ-BSL42 600×1200×2000mm, 42U, reinforced nine-fold profiled steel, static load 2000kg 1 Unit 2308.72 2308.72 KITOZER Dedicated for closed-loop liquid cooling
2 Closed-Loop Coolant Distribution Unit (CDU) KTZ-BCDU20 Cooling capacity 20kW, plate heat exchanger isolation, dual circulation, deionized internal water 1 Unit 12431.55 12431.55 KITOZER Closed-loop circulation host
3 Micro-Channel Rear Door Heat Exchanger KTZ-BHB01 Closed-loop dedicated, pure copper micro-channel, anti-corrosion treatment, heat exchange efficiency 95% 1 Set 6215.77 6215.77 KITOZER In-cabinet heat exchange
4 20kVA Online UPS KTZ-UPS20K 20kVA/18kW, three-in three-out, online double conversion, 15-minute backup 1 Unit 10655.61 10655.61 KITOZER High-density power supply
5 High-Power Intelligent PDU KTZ-GPDU12 12 outlets 16A, total power 25kW, current & voltage monitoring, remote on/off 2 Unit 621.58 1243.16 KITOZER High-power adaptation
6 Closed-Loop Liquid Cooling Monitoring System KTZ-BMON Dual-loop temp/pressure/flow monitoring, conductivity monitoring, leak detection, alarm linkage 1 Set 4217.85 4217.85 KITOZER Dedicated closed-loop monitoring
7 Positioning Leak Detection KTZ-DLS02 5-meter positioning leak cable, precise positioning, two-level alarm, linked water shutoff 1 Set 887.97 887.97 KITOZER Full pipeline coverage
8 Closed-Loop Piping Kit KTZ-BGL01 304 stainless steel piping, quick-connect fittings, valves, expansion tank, filters 1 Set 1331.95 1331.95 KITOZER Complete in-cabinet piping
9 Deionized Water Kit KTZ-DI01 Deionized coolant, deionized filter cartridge, conductivity sensor 1 Set 665.98 665.98 KITOZER First fill
10 Installation Accessory Pack KTZ-BACC Mounting brackets, anti-vibration pads, insulation parts, grounding bar, shelves 1 Set 443.99 443.99 KITOZER Supporting accessories

Total Quotation Price: USD 40402.54

9. Quotation Terms & Conditions

  • Currency: All prices are quoted in USD.
  • Price Basis: EXW Guangzhou, China (or as negotiated).
  • Tax & Shipping: The above quotation excludes taxes and transportation costs. Invoices can be issued upon request with applicable taxes calculated separately. Shipping is arranged by logistics with freight collect; goods are self-picked at the destination city logistics point. Door-to-door delivery can be arranged through separate negotiation.
  • Payment Terms: 30% deposit / 70% balance before shipment (negotiable).
  • Lead Time: 15-30 working days depending on configuration.
  • Quotation Validity: 30 days from the date of quotation.
  • Packing: Standard export packing; packing and shipping costs are quoted separately upon request.

10. After-sales Service Description

  • Warranty: 12-24 months warranty depending on product category.
  • Technical Support: Lifetime technical support provided free of charge.
  • Spare Parts: Long-term availability of spare parts for all KITOZER products.
  • Service Options: Remote troubleshooting and on-site service available as needed.

11. Contact & Order Information

Orders can be placed through the official KITOZER website (gdlain.com) or by contacting the KITOZER sales team. All inquiries receive a response within 24 hours. Please provide your project specifications and requirements to receive a customized quotation tailored to your needs.

12. SEO Keywords & Tags

Closed-loop water-cooled integrated cabinet, closed-loop liquid cooling cabinet quotation, KITOZER quotation, closed-loop water-cooled cabinet price list, CDU closed-loop water cooling unit price, precision equipment water-cooled cabinet factory price, sealed circulation water-cooled cabinet, KITOZER closed-loop cooling cabinet wholesale, closed-loop liquid cooling cabinet manufacturer quote, closed vs open water cooling system, deionized water cooling cabinet price, 10-40kW closed-loop cooling cabinet factory price, high-density closed-loop liquid cooling cabinet supplier, KITOZER BSL series quotation, closed-loop CDU water cooling unit cost, rear door heat exchanger price, intelligent PDU for cooling cabinet price

Scroll to Top