ToggleKITOZER KTR-SC24APC Rack 24-Port SC APC OM4 Fiber Patch Panel
Brand: KITOZER Series: KTR-SC24APC Category: Data Center Engineering / Fiber Patch Panel
24-port SC APCOM4 multimode19-inch 1Urack ODFKTR-SC24APC
1. Overview
The KITOZER KTR-SC24APC is a 19-inch rack-mount, 24-port SC APC OM4 multimode fiber patch panel (ODF) in 1U, installed in network or server racks to terminate, splice and patch backbone fiber. It is the core low-voltage fiber patching device: the incoming backbone cable enters, pigtails are spliced to its fibers one-to-one, the panel’s SC adapters bring the splices out, and SC jumpers then connect to switch optical ports. 24 ports means 24 SC adapters (12 duplex channels), supporting 24 fibers (48 if counted duplex).
“SC APC” means SC connectors with 8-degree angled APC polish, green housing, low back reflection for PON, video and high-speed links; “OM4” means OM4 multimode (50/125 μm, higher bandwidth than OM3, supporting longer-reach 10/40/100G multimode). Inside is a splicing tray: the cable enters and is stripped and anchored, each fiber is spliced to an SC pigtail, splices are protected by heat-shrink sleeves in the tray, and pigtails are coiled out to the adapters. The front panel is removable and flip-up for splicing access.
In data centers and low-voltage rooms, KTR-SC24APC panels are racked in rows at the top of the cabinet, working with cable managers and switches to form a complete backbone-to-equipment patching chain. OM4 panels commonly link access switches to servers over multimode, supporting 10GBASE-SR, 40GBASE-SR4 and other short-reach high-speed apps. SC APC polish gives more stable low-reflection high-speed links. Panels ship loaded or unloaded by project need, paired with SC APC OM4 jumpers and OM4 backbone cable.
2. Key Features
24-port density
- 19-inch 1U.
- 24 SC adapters.
- 12 duplex channels.
- Rows in top of rack.
SC APC polish
- 8-degree angle.
- Green housing.
- Low return loss.
- Stable at high speed.
OM4 bandwidth
- 50/125 μm multimode.
- 10/40/100G capable.
- Longer than OM3.
- Short-reach high speed.
Built-in splicing tray
- Splice tray.
- Heat-shrink holders.
- Pigtail coiling.
- Removable front panel.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-SC24APC |
| Mounting | 19-inch rack |
| Rack units | 1U |
| Ports | 24 SC (12 duplex) |
| Polish | APC (8-degree angle) |
| Fiber type | OM4 50/125 μm multimode |
| Adapters | SC APC green ceramic sleeve |
| Splice tray | built-in, pull-out |
| Insertion loss | ≤0.3 dB/adapter |
| Material | coated sheet steel |
4. Reference Prices
KTR-SC24APC 24-port SC APC OM4 panel (loaded): Reference USD 45~80 / pc (ref. CNY 320~580 at ~7.2)
KTR-SC24APC panel (empty, no adapters): Reference USD 21~36 / pc (ref. CNY 150~260 at ~7.2)
Reference only; empty unit needs adapters separately. Pigtails and jumpers excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center backbone termination.
- Server access switch patching.
- Low-voltage room ODF.
- 10/40G multimode links.
- High-speed low-reflection links.
6. Installation & Maintenance
Installation
- Fix at 1U in rack.
- Cable enters and anchors at rear.
- Strip cable, fix strength member.
- Splice fibers to pigtails.
- Heat-shrink into tray.
- Pigtails to adapters, test.
Maintenance
- Clean adapter faces periodically.
- Cap unused ports.
- Clear jumper labels.
- No crushing in tray.
- Sample-test optical power.
- Replace damaged adapters.
7. FAQ
- Q: Loaded or empty?
A: Loaded has 24 adapters pre-fitted, ready to splice and patch, simpler but pricier; empty gives just the frame, with adapters bought as needed for tight budgets or uncertain port counts. Projects often take loaded for consistent adapter quality. - Q: Can OM3 jumpers go into an OM4 panel?
A: Physically yes, but bandwidth is limited to OM3 reach. Since the panel is OM4, use OM4 jumpers and cable end-to-end to avoid a bottleneck. - Q: Why is APC green?
A: Green housing is the standard APC marker, distinguishing it from blue UPC. Green means angled polish with ≥60 dB return loss — lower reflection, more stable links in PON and high-speed optics. - Q: 24 ports in 1U — too crowded?
A: Two rows of 24 SC adapters in 1U is standard density; the tray and pigtail space is adequate. Just mate jumpers gently to avoid tugging splices.
8. Trend & Selection
Data center patching moves toward high bandwidth, high density and low reflection; OM4/OM5 multimode and APC polish spread in short-reach high-speed links. Size ports by fiber count (24/48), choose APC/UPC by polish and OM3/OM4 by bandwidth; keep panel, jumpers and cable the same type, with cleaning tools and labels.
9. Delivery & Service
KITOZER selects KTR-SC24APC quantity and loaded/empty by rack port needs, providing outline drawings and splicing guidance. Delivery includes panel body, adapters (if loaded), splicing tray and certificates. Warranty covers splicing and link-test guidance.
10. Additional Notes
A common pitfall is coiling pigtails below minimum bend radius or under a pressed cover. Pigtails and cable have a minimum bend radius — keep coils generous and never let the cover press on pigtails, or loss rises and fibers may break.
Another pitfall is not anchoring the cable strength member. The strength member (Kevlar/steel) must be firmly fixed to the panel’s ground post to take tension; otherwise pull transmits to the splices and breaks fibers. The outer jacket must also be fixed so no strain hangs on bare fibers.
Selection summary: 19-inch 1U; 24-port SC APC; OM4 high bandwidth; built-in splicing tray; low loss and reflection; matched jumpers and cable. The panel is the terminus of backbone cable to equipment — sound splices, neat pigtails, clean faces keep 10G/100G links running end to end.