Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Atmospheric Conventional Parameter Monitoring System

KITOZER Atmospheric Conventional Parameter Monitoring System Quotation List

LargeAir Conventional ParametersCountMonitoringSystem

2. Project Requirement Description

To meet ambient air quality monitoring requirements, a continuous atmospheric conventional parameter monitoring system shall be established to achieve:

  • 24-hour continuous online monitoring of gaseous pollutants: SO₂, NO₂, CO, O₃
  • 24-hour continuous online monitoring of particulate matter: PM2.5, PM10
  • Synchronous monitoring of meteorological parameters
  • Monitoring data compliant with environmental protection monitoring standards
  • Support for data upload to regulatory platforms
  • Data statistics, quality control, and exceedance early-warning functions
  • Support for regional air quality assessment and management & control requirements

3. System Composition Introduction

The system mainly consists of the following components:

  • Gaseous pollutant monitoring unit
  • Particulate matter monitoring unit
  • Meteorological parameter sensors
  • Data acquisition and quality control unit
  • Outdoor protective cabinet
  • Sampling system
  • Pole bracket
  • Wireless transmission module
  • Cloud platform management system
  • Installation and auxiliary accessories

4. Core Product Specifications & Parameters

Gaseous Pollutant Monitoring Unit (KTR-DQ-04):

  • Detection principle: Electrochemical
  • Monitoring parameters: SO₂, NO₂, CO, O₃ (four gases)
  • SO₂ range: 0–5000 ppb
  • NO₂ range: 0–4000 ppb
  • CO range: 0–50 ppm
  • O₃ range: 0–5000 ppb
  • Accuracy: ≤±5% FS
  • Resolution: 1 ppb

Particulate Matter Monitoring Unit (KTR-KL-02):

  • Detection principle: Light scattering
  • Monitoring parameters: PM2.5, PM10
  • Range: 0–1000 μg/m³
  • Accuracy: ±10%
  • Resolution: 1 μg/m³
  • Sampling mode: Pump-suction type

Meteorological Sensor (KTR-QX-05):

  • Monitors temperature, humidity, wind speed, wind direction, atmospheric pressure
  • Provides meteorological basis for data correction

Data Acquisition & Quality Control Unit (KTR-CJ-05):

  • Multi-channel data acquisition
  • Zero calibration, span calibration, data quality control functions
  • Local storage capacity: ≥32G

Outdoor Protective Cabinet (KTR-JG-01):

  • Cold-rolled steel plate, plastic spraying finish
  • Thermostatic design
  • Dimension: 800×600×1800 mm
  • Protection rating: IP55
  • Built-in heat dissipation and dehumidification modules

Sampling System (KTR-CY-01):

  • Includes sampling head, sampling pipeline, air pump
  • Dust filtration and dehumidification functions

5. Core Functions & Features of Products

Core Functions:

  • Continuous Monitoring: 24-hour continuous monitoring of six conventional atmospheric parameters and meteorological data; sampling frequency configurable
  • Quality Control: Supports automatic zero calibration and span calibration, ensuring data accuracy and comparability
  • Data Transmission: Supports 4G/Ethernet transmission, compliant with HJ/T212 communication protocol, compatible with environmental protection platforms at all levels
  • Exceedance Early Warning: Configurable pollutant concentration thresholds with automatic push alert messages when thresholds are exceeded
  • Data Statistics: Supports hourly average, daily average, monthly average statistics; generates air quality reports
  • Remote Operation & Maintenance: Supports remote device status monitoring, parameter configuration, calibration operations, and fault diagnosis

Key Features:

  • Adopts mature electrochemical and light scattering detection technologies — data is stable and reliable, compliant with environmental monitoring technical requirements
  • Integrated design, compact structure, easy installation and maintenance, small footprint
  • Thermostatic cabinet design ensures stable sensor operation under high/low temperature environments and extends equipment service life
  • Complete data quality control system with traceable data, meeting environmental monitoring data specifications
  • Supports multiple transmission modes and protocols for flexible integration with different regulatory platforms

6. Core Advantages of The Solution

  • Standards Advantage: Monitoring parameters and data specifications comply with national ambient air quality monitoring standards, adapted for regulatory platform integration
  • Performance Advantage: Core sensors feature stable performance, high data accuracy, and low long-term drift
  • Customization Advantage: Supports customized monitoring parameter combinations, cabinet styles, and platform functions; OEM manufacturing available
  • Supply Advantage: Core products available from stock for rapid delivery; complete confidentiality mechanism ensures project information security

7. Manufacturer Strength Introduction

KITOZER (production entity: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Machine Room Equipment Co., Ltd.):

  • Founded in 2002, located in Guangzhou, China
  • ISO 9001 / ISO 14001 / ISO 45001 certified high-tech enterprise
  • Own production base with a professional R&D team
  • Full in-house capability for atmospheric monitoring equipment assembly, calibration, and testing
  • Supports product customization and OEM manufacturing
  • Complete project confidentiality system
  • Core models kept in stock for rapid response to environmental protection, industrial park, and factory monitoring projects
  • Provides professional technical support and after-sales service

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Four-gas Gaseous Pollutant Monitoring Unit KTR-DQ-04 Electrochemical principle, monitoring SO₂/NO₂/CO/O₃, accuracy ±5% FS 1 Set 3,995.86 3,995.86 KITOZER
2 Dual Dust Particulate Matter Monitoring Unit KTR-KL-02 Light scattering principle, monitoring PM2.5/PM10, pump-suction sampling, accuracy ±10% 1 Set 1,775.94 1,775.94 KITOZER
3 Five-element Meteorological Sensor KTR-QX-05 Temperature & humidity, wind speed/direction, air pressure; ultrasonic wind speed/direction, IP65 1 Set 799.17 799.17 KITOZER
4 Data Acquisition & Quality Control Unit KTR-CJ-05 Multi-channel acquisition, data QC, 32G local storage, supports HJ/T212 1 Unit 1,109.96 1,109.96 KITOZER
5 Outdoor Thermostatic Protection Cabinet KTR-JG-01 Cold-rolled steel plate sprayed, thermostatic & dehumidifying, 800×600×1800mm, IP55 1 Set 1,331.95 1,331.95 KITOZER
6 Sampling System KTR-CY-01 Sampling head, sampling pipeline, air pump, filtration & dehumidification components 1 Set 532.78 532.78 KITOZER
7 3m Pole Bracket KTR-LG-03 Carbon steel sprayed, includes cabinet mounting bracket, wind-resistant to Level 12 1 Set 310.79 310.79 KITOZER
8 4G Wireless Transmission Module KTR-4G-02 Full network compatible, supports Ethernet, data encryption, HJ/T212 protocol 1 Set 266.39 266.39 KITOZER
9 Cloud Platform Management System KTR-PLAT-04 Air quality monitoring platform, data QC, statistical analysis, report generation 1 Set 1,331.95 1,331.95 KITOZER Permanent license
10 Installation Accessories KTR-FC-03 Cables, connectors, fasteners, lightning protection accessories, calibration accessories 1 Set 266.39 266.39 KITOZER

Total Quotation Price: USD 11,721.18

9. Quotation Terms & Conditions

  • All prices above are quoted in USD and do not include tax or freight.
  • VAT special invoice: additional 10% tax point; VAT ordinary invoice: additional 3% tax point (applicable per local regulation).
  • Freight: logistics freight collect (payable upon delivery); default shipment via dedicated logistics line; courier/logistics provider can be designated upon request.
  • Payment terms: 30% deposit, 70% balance before shipment (negotiable).
  • Delivery lead time: in-stock products shipped within 3 working days; custom products lead time to be negotiated separately.
  • Price basis: EXW Guangzhou, China (or as negotiated).
  • Validity of quotation: 30 days from the date of issue.
  • Packing and shipping costs are quoted separately upon request.

10. After-sales Service Description

  • Warranty: 12–24 months depending on product configuration.
  • Lifetime technical support after warranty period.
  • Genuine spare parts availability for all core products.
  • Remote troubleshooting support with fast response.
  • On-site installation guidance and commissioning services available upon request.
  • Calibration and maintenance services provided throughout the equipment lifecycle.

11. Contact & Order Information

Orders can be placed via the official website gdlain.com or by contacting the KITOZER sales team directly.

  • Contact Person: Mr. Zhou
  • Phone: +86 13538869979
  • Production Entity: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Machine Room Equipment Co., Ltd.
  • Brand: KITOZER (own brand)
  • Address: Chaotian Area, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

All inquiries receive a response within 24 hours.

12. SEO Keywords & Tags

KITOZER quotation, atmospheric conventional parameter monitoring system price list, air quality monitoring station quotation, atmospheric six-parameter monitoring system manufacturer, ambient air quality automatic monitoring system price, gaseous pollutant monitoring equipment price, particulate matter PM2.5 PM10 monitoring device quotation, SO2 NO2 CO O3 monitor price, atmospheric monitoring system factory price, wholesale air quality monitoring system quotation, KITOZER atmospheric monitoring system, environmental air monitoring equipment cost, air quality automatic monitoring station quotation, atmospheric monitoring system price, KITOZER quotation list, atmospheric monitoring system factory price, air quality monitoring system wholesale quotation

Scroll to Top