KITOZER Industrial Laboratory Environmental Monitoring System Quotation List
Table of Contents

2. Project Requirement Description
- Dedicated environmental monitoring system for precision industrial laboratories, physical & chemical laboratories, and cleanrooms.
- High-precision monitoring of temperature & humidity, cleanroom differential pressure, TVOC, acid/alkaline hazardous gases, noise, and illumination.
- Precision instrument rooms require temperature accuracy of ±0.1°C; cleanrooms require real-time differential pressure monitoring.
- Automatic linkage of ventilation and acid/alkali waste gas treatment equipment upon temperature, humidity, or gas exceedance.
- Local high-precision data storage with support for laboratory test report data export.
- High-precision, low-drift equipment with dual 485/Ethernet transmission.
- Suitable for precision instrument laboratories, chemical & physical laboratories, and dust-free cleanrooms.
- Compliant with CNAS laboratory environmental control standards.
3. System Composition Introduction
Perception Layer:
- Ultra-high-precision temperature & humidity transmitters
- Cleanroom differential pressure sensors
- Acid/alkaline hazardous gas detectors
- TVOC volatile organic compound sensors
- Noise and illumination transmitters
- Airborne particle monitoring terminals
Transmission Layer:
- Industrial PoE switches
- High-precision data acquisition gateways
Control Layer:
- Laboratory equipment linkage control cabinets
- Explosion-proof audible & visual alarm terminals
Management Layer:
- Laboratory environmental monitoring software
- 21-inch industrial touch terminals
- Local data storage host
- SMS alarm module
4. Core Product Specifications & Parameters
| Product | Model | Key Specifications |
|---|---|---|
| High-Precision Laboratory Temp & Humidity Sensor | KT-LAB-TH | Temperature accuracy ±0.1°C, humidity ±0.2%RH; range 0–50°C, 0–100%RH; imported platinum resistance chip; annual drift ≤0.05°C; PoE powered |
| Cleanroom Differential Pressure Transmitter | KT-LAB-CY | 0–1000Pa, accuracy ±1Pa; real-time positive/negative pressure monitoring; 4-20mA output |
| Acid/Alkaline Gas Sensor | KT-LAB-GAS | Detects hydrochloric acid, sulfuric acid, ammonia, TVOC; electrochemical high-specificity sensing; resistant to laboratory reagent vapor interference |
| Laboratory Environmental Monitoring Software V3.0 | KT-LAB-SOFT | Compliant with CNAS laboratory standards; auto-generates environmental record reports; data directly exportable for test report archiving; supports waste gas & ventilation equipment linkage |
5. Core Functions & Features of Products
Functions:
- Full-dimension data acquisition of laboratory temperature & humidity, cleanroom differential pressure, acid/alkaline hazardous gases, TVOC, noise, illumination, and airborne particles
- Ultra-high-precision constant temperature & humidity monitoring in precision instrument rooms; automatic linkage with air conditioning and constant-temperature equipment for precise regulation upon threshold deviation
- Automatic linkage of waste gas treatment and exhaust systems in chemical laboratories upon acid/alkaline gas or VOC exceedance
- Real-time positive/negative pressure monitoring in cleanrooms; timely alarm on pressure differential abnormality to ensure dust-free experimental environment
- System data conforms to CNAS laboratory environmental recording standards; auto-generates standardized environmental logs for direct archiving
- Local encrypted storage of 180 days of high-precision data; curve playback and exceedance record traceability for laboratory review inspection
- Three-terminal synchronized viewing via PC, industrial touch screen, and mobile mini-program for real-time laboratory environmental status awareness
- Multi-level alarm on gas, temperature/humidity, and pressure exceedance: local audible & visual, SMS to laboratory managers, and backend pop-up
Features:
- Ultra-high-precision sensing chips with platinum resistance temperature & humidity probes, suitable for stringent precision instrument and metrology laboratory requirements
- Chemical laboratory-specific gas sensors resistant to reagent vapor and acid/alkali steam interference; long-term stable data without drift
- Cleanroom-specific differential pressure transmitters with minimal range and high precision for precise control of dust-free workshop positive/negative pressure environments
- Software includes built-in CNAS laboratory environmental recording templates; no manual log organization needed; auto-generates archival reports
- Low-drift equipment design requiring only one simple calibration per year, greatly reducing laboratory O&M workload
- Modular layered architecture allows independent zone control for physical/chemical laboratories, precision instrument rooms, and cleanrooms without mutual interference
6. Core Advantages of The Solution
- KITOZER laboratory-specific monitoring equipment; software & hardware compliant with CNAS review standards; complete documentation supports laboratory qualification acceptance
- Ultra-high-precision sensors outperform common industry equipment, meeting stringent environmental requirements for metrology, precision optics, and semiconductor laboratories
- Open standard communication protocols; can link with laboratory fume hoods, waste gas treatment units, and constant temperature & humidity air conditioners
- Data report formats match laboratory testing systems; environmental data can be directly interfaced with experiment report archiving systems
- Corrosion-resistant enclosures suitable for harsh chemical laboratory environments with acid/alkali vapor and organic solvent volatility
- Flexible point expansion; new laboratory or bench monitoring points can be directly added without replacing the core platform
7. Manufacturer Strength Introduction
- Guangzhou Lai’an Intelligent System Development Co., Ltd. (brand KITOZER), founded in 2002, is a high-tech enterprise certified with ISO 9001, ISO 14001, and ISO 45001.
- Long-term partner for various physical/chemical, precision, and cleanroom laboratory environmental monitoring projects; familiar with CNAS review environmental control requirements.
- Ultra-high-precision sensors are factory-calibrated as complete units; each unit ships with a precision inspection certificate, directly usable for laboratory review.
- Free provision of laboratory point layout drawings and standardized construction plans for temperature/humidity and differential pressure monitoring.
- Full series equipment carries a 24-month warranty, with annual sensor calibration technical guidance services.
- Support for software report template and interface LOGO customization to match laboratory standardized management systems.
- 7×24-hour professional technical after-sales support; expedited production for laboratory projects; on-site commissioning and integration with laboratory systems.
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Ultra-High-Precision Laboratory Temp & Humidity Transmitter | KT-LAB-TH | ±0.1°C accuracy, platinum resistance probe, PoE powered | 34 | Unit | 338.32 | 11502.87 | KITOZER | Deployed in precision instrument rooms and metrology laboratories |
| 2 | Cleanroom Differential Pressure Sensor | KT-LAB-CY01 | 0-1000Pa, ±1Pa high precision, cleanroom specific | 16 | Unit | 211.33 | 3381.24 | KITOZER | Cleanroom entrances/exits and buffer rooms |
| 3 | Acid/Alkaline TVOC Composite Gas Monitoring Terminal | KT-LAB-GAS06 | Ammonia/Hydrochloric acid/Sulfuric acid/TVOC four parameters, reagent vapor resistant | 12 | Unit | 423.56 | 5082.72 | KITOZER | Beside fume hoods in chemical/physical laboratories |
| 4 | Laboratory Airborne Particle Monitoring Module | KT-LAB-PM03 | 0.3μm particle counting, real-time cleanroom class determination | 8 | Unit | 539.88 | 4319.06 | KITOZER | For Class 10,000/1,000 cleanroom support |
| 5 | Laboratory Noise & Illumination Transmitter | KT-LAB-NL02 | 30-120dB noise, 0-10000lux illumination integrated | 10 | Unit | 160.72 | 1607.22 | KITOZER | Monitoring at laboratory workbench areas |
| 6 | 16-Port PoE Industrial Precision Switch | KT-SW-POE16 | Low noise, chemical corrosive gas resistant, DIN-rail mounting | 3 | Unit | 960.79 | 2882.36 | KITOZER | Networking and powering all high-precision sensors |
| 7 | Laboratory Ventilation Linkage Control Cabinet | KT-CAB-LAB08 | 8 relay channels, links waste gas treatment & exhaust equipment | 6 | Unit | 879.98 | 5279.86 | KITOZER | Independent ventilation control per laboratory |
| 8 | Laboratory Environmental Monitoring Software V3.0 | KT-LAB-SOFT-V3 | CNAS standard reporting, permanent local license | 1 | Set | 16676.93 | 16676.93 | KITOZER | Full software suite for laboratory management backend |
| 9 | 21-Inch Industrial Touch Display Terminal | KT-DIS-LAB21 | Corrosion-resistant panel, real-time data display in laboratory hall | 2 | Unit | 2492.52 | 4985.04 | KITOZER | Installed in laboratory central control office |
| 10 | High-Precision Local Data Storage Host | KT-SRV-LAB | Solid-state storage, 180-day high-precision data cache | 1 | Unit | 11044.25 | 11044.25 | KITOZER | Laboratory environmental data archiving |
| 11 | 4G SMS Alarm Module | KT-AL-SMS04 | Simultaneous push of exceedance alerts to multiple lab supervisors | 2 | Unit | 539.88 | 1079.76 | KITOZER | Real-time alerts for laboratory management personnel |
| 12 | Explosion-Proof Corrosion-Resistant Audible & Visual Alarm | KT-AL-LAB-SG | Acid/alkali resistant enclosure, local alarm for chemical laboratories | 10 | Unit | 142.96 | 1429.62 | KITOZER | Deployed at each laboratory entrance |
Total Quotation Price: USD 69271.93
9. Quotation Terms & Conditions
- All prices listed above are in US Dollars (USD), EXW Guangzhou, China (or as negotiated).
- The total quotation price of USD 69,271.93 excludes taxes, freight, and installation costs.
- Payment terms: 30% deposit upon order confirmation, 70% balance before shipment (negotiable).
- Lead time: 15-30 working days depending on configuration and order quantity.
- Validity of quotation: 30 days from the date of issuance.
- Packing, freight, and insurance costs are quoted separately based on destination and shipping method.
- Corrosion-resistant cables, installation accessories, and on-site commissioning can be quoted separately upon request.
- Invoicing options: standard commercial invoice (no tax), or VAT invoice at an additional 10% (special) or 3% (regular) as applicable.
10. After-sales Service Description
- Full series equipment carries a 24-month warranty from the date of delivery.
- Lifetime technical support and consultation services.
- Annual sensor calibration technical guidance provided by the manufacturer.
- Spare parts availability guaranteed for the lifetime of the products.
- Remote troubleshooting support available via phone, email, or video conference.
- On-site commissioning, installation guidance, and maintenance services available upon request.
- Complete CNAS laboratory environmental review documentation package provided with the system.
11. Contact & Order Information
- To place an order, please visit our official website at gdlain.com or contact the KITOZER sales team directly.
- All inquiries receive a response within 24 hours.
- Please specify the required system configuration, quantities, and delivery destination when requesting a final quotation.
- Custom software report templates, interface LOGO customization, and laboratory-specific configuration services are available upon request.
- KITOZER / Guangzhou Lai’an Intelligent System Development Co., Ltd. — your professional partner for laboratory environmental monitoring solutions.
12. SEO Keywords & Tags
Industrial laboratory environmental monitoring system, KITOZER quotation, precision instrument laboratory temperature and humidity monitoring system, chemical physical laboratory acid alkali gas monitoring equipment, cleanroom differential pressure online monitoring terminal, CNAS laboratory environmental recording monitoring system, laboratory waste gas ventilation linkage monitoring device, high precision laboratory dynamic environment monitoring equipment, KITOZER laboratory monitoring equipment, industrial laboratory environmental monitoring system price list, precision laboratory temperature and humidity sensor manufacturer, cleanroom differential pressure monitoring equipment parameters, laboratory environmental monitoring system cost, laboratory environmental monitoring system factory price, wholesale laboratory environmental monitoring system quotation