KITOZER Data Center Fire Alarm Linkage Monitoring System Quotation List
Table of Contents

2. Project Requirement Description
Server rooms, battery rooms, and power distribution cabinets constitute high fire-risk zones. Conventional fire alarm controllers only provide local alarms and are incapable of synchronously pushing notifications to the data center operation and maintenance (O&M) platform. The lack of early-stage smoke and high-temperature pre-warning in fire incidents delays the linkage of video surveillance, power distribution, and access control systems, resulting in critical response delays and potential large-scale data loss.
The specific project requirements are as follows:
- Integrate with existing fire alarm controllers on-site to enable real-time collection of smoke detector, heat detector, and gas suppression equipment alarm signals;
- Deploy very early warning aspirating smoke detectors to capture trace smoke particles and achieve early fire pre-warning;
- Fire alarm linkage: automatically display surveillance video of the affected zone, cut power to the faulty area, and unlock emergency access control doors;
- Multi-channel fire event escalation: provide pre-warning, fire alarm, and equipment fault alerts via SMS and APP push notifications;
- Complete fire event archiving for a minimum of 3 years, supporting traceability of alarm time, detection points, and handling procedures;
- Unified data exchange with the existing environmental monitoring (DCIM), video surveillance, power distribution, and access control systems for integrated management;
- Support real-time monitoring of heptafluoropropane (FM200) gas suppression system status in the battery room.
3. System Composition Introduction
The KITOZER Data Center Fire Alarm Linkage Monitoring System adopts a four-layer architecture: front-end fire detection, signal acquisition & conversion, linkage control unit, and fire monitoring platform.
- Front-end fire detection: Very early aspirating smoke detectors (VESDA), fire signal acquisition modules, and gas suppression status monitoring units;
- Signal acquisition & conversion: Fire protocol conversion gateway, two-wire signal isolators, and digital input acquisition modules;
- Linkage control unit: Relay output modules, audible & visual fire alarm devices, and video linkage triggers;
- Fire monitoring platform: Fire alarm linkage management software, local industrial storage server, and remote alarm push module.
4. Core Product Specifications & Parameters
Very Early Aspirating Smoke Detector – KITOZER-FIRE-A04
- Detection sensitivity: 0.001% obs/m, 1000 times more sensitive than standard smoke detectors;
- 4 sampling pipe networks, each pipe max. length 100m, featuring precise smoke sampling hole location;
- Three-stage alarm: Pre-alarm, Fire Alarm 1, Fire Alarm 2; response time ≤5s;
- Communication: RS485 Modbus; Power supply: DC24V.
Fire Alarm Host Protocol Acquisition Gateway – KITOZER-GW-FIRE
- Compatible with mainstream fire alarm controller brands; converts two-bus signal to Ethernet protocol;
- 16 digital inputs for smoke, heat, and gas suppression feedback signals;
- 8 relay outputs for linkage with power distribution, video, and access control devices.
Fire Alarm Linkage Management Software V4.0
- Data center floor plan fire point electronic map with highlighted fire alarm zones;
- Customizable linkage strategies: auto video switch, power cut, and door unlock upon fire alarm;
- 3-year fire event storage; alarm logs and handling records exportable for audit purposes.
5. Core Functions & Features of Products
- Full fire signal acquisition: Integrates with the fire alarm host to read real-time status of smoke detectors, heat detectors, manual call points, and gas suppression devices;
- Very early fire pre-warning: Aspirating detectors capture trace smoke for advance warning before a fire ignites, mitigating major fire risks;
- Multi-system linkage response: Fire alarm triggers automatic display of corresponding zone surveillance, power cut to hazardous areas, and emergency door unlock;
- Multi-level fire alarm push notifications: Local high-decibel audible/visual alarms, SMS, WeChat, and mobile APP push alerts simultaneously;
- Fire point electronic map visualization: Floor plan marks all smoke detectors, aspirating sampling points, and extinguishing device locations;
- Full fire event lifecycle logging: Pre-alarm, fire, fault, reset, and handling operations are archived with complete logs for 3 years;
- Online equipment fault monitoring: Real-time alerts for detector disconnection, extinguishing agent pressure loss, and gateway failures;
- Customizable linkage strategy configuration: Different linkage actions can be pre-set for varying fire alarm levels;
- Third-party platform integration: Open standard interfaces to connect with the central DCIM monitoring platform for unified management.
6. Core Advantages of The Solution
- Pre-emptive fire pre-warning: Unlike traditional post-incident alarms, very early detection enables preventive control before a fire occurs, preventing server burnout and data loss;
- Integrated linkage response: Fire alarms automatically link to video, power distribution, and access control systems, eliminating manual multi-step operations and shortening emergency response times;
- Existing system utilization: Compatible with existing fire alarm controllers, eliminating the need for full system replacement and significantly reducing project investment;
- Complete fire audit archive: 3-year fire event storage meets compliance requirements for data centers and classified/confidential server rooms;
- Comprehensive fire monitoring coverage: Complete coverage of server room aisles, top of cabinets, battery rooms, and power distribution cabinet areas;
- Lightweight O&M: Automatic reporting of fire equipment faults, periodic inspection reminders, and reduced manual troubleshooting workload;
- Ideal for unattended server rooms: Remote push of fire alarm information ensures off-site operators receive immediate risk notifications.
7. Manufacturer Strength Introduction
Guangzhou Lai’an Intelligent System Development Co., Ltd. (brand KITOZER) is a high-tech enterprise founded in 2002, dedicated to intelligent monitoring and control systems. The company is certified with ISO 9001 (Quality Management), ISO 14001 (Environmental Management), and ISO 45001 (Occupational Health & Safety). Key strengths include:
- Self-developed fire alarm linkage gateways and acquisition modules under the KITOZER brand, supporting customization, OEM manufacturing, confidentiality agreements, and stock supply;
- Proven and mature data center fire alarm linkage solutions with extensive implementation cases in government, financial, and confidential server room projects;
- Full in-house production of hardware and software with independent fire protocol analysis, eliminating third-party equipment compatibility issues;
- Hardware: 3-year free warranty; Software: lifetime free upgrades; 7×24-hour remote emergency technical support;
- Factory stock of gateways and acquisition modules enables delivery of standard orders within 3 working days;
- Free provision of fire point layout drawings and linkage strategy configuration plans;
- On-site technical support available for integration with existing fire alarm controllers and on-site commissioning of linkage functions.
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Very Early Aspirating Smoke Detector | KITOZER-FIRE-A04 | 4 sampling pipe networks, 0.001% obs/m high sensitivity, three-stage alarm | 4 | Unit | 2486.31 | 9945.23 | KITOZER | Deployed in main server room area, battery room, and power distribution cabinet area |
| 2 | Fire Protocol Acquisition Linkage Gateway | KITOZER-GW-FIRE | Compatible with multiple fire alarm host brands, 16 DI / 8 DO relay linkage | 2 | Unit | 1278.67 | 2557.34 | KITOZER | Integrates with fire alarm host, outputs linkage signals |
| 3 | Gas Suppression Status Monitoring Unit | KITOZER-FIRE-GAS | Monitors heptafluoropropane pressure and valve status, dry contact acquisition | 3 | Unit | 479.50 | 1438.51 | KITOZER | Monitoring of gas suppression devices in battery room |
| 4 | Fire Dedicated Audible & Visual Alarm | KITOZER-ALM-FIRE | 110dB high decibel, alternating red/blue light fire indication | 3 | Unit | 204.23 | 612.70 | KITOZER | Audible/visual alarm in server room and monitoring room |
| 5 | 8-Port Industrial POE Switch | KITOZER-SW08P | Gigabit POE-powered, surge protection, power and data transmission for gateways and detectors | 2 | Unit | 372.95 | 745.89 | KITOZER | Network transmission and power supply for fire protection equipment |
| 6 | Fire Alarm Linkage Management Software V4.0 | KITOZER-FIRE-V4 | Fire electronic map, multi-system linkage, 3-year event storage, API integration | 1 | Set | 3966.26 | 3966.26 | KITOZER | Permanent license, lifetime free upgrades |
| 7 | 4U Industrial Storage IPC | KITOZER-IPC4U | 16G RAM, 4T SSD, long-term storage of fire alarm records | 1 | Unit | 2900.70 | 2900.70 | KITOZER | Locally runs fire monitoring platform |
| 8 | Sampling Pipes, Communication Cables, Installation Accessories | Customized Package | PVC sampling pipes, shielded two-bus cables, wall-mount brackets, waterproof terminals | 1 | Batch | 1296.43 | 1296.43 | KITOZER | Complete set of installation consumables |
Total Quotation Price: USD 23463.06
Note: Prices are exclusive of tax and freight. Special VAT invoice +10%, ordinary invoice +3%, freight to be collected upon delivery.
9. Quotation Terms & Conditions
- All prices listed above are in US Dollars (USD);
- Pricing basis: EXW Guangzhou, China (or as otherwise negotiated);
- Payment terms: 30% deposit with order, 70% balance before shipment (negotiable);
- Lead time: 15-30 working days depending on configuration and order quantity;
- Validity period of this quotation: 30 days from the date of issue;
- Packing, freight, and insurance costs are quoted separately;
- The above prices are exclusive of applicable taxes and duties.
10. After-sales Service Description
- Warranty: 12-24 months depending on product category (KITOZER brand hardware carries a 3-year free warranty, with software entitled to lifetime free upgrades);
- Lifetime technical support provided at no charge;
- Spare parts availability guaranteed for the product lifecycle;
- Remote troubleshooting assistance available 7×24;
- On-site commissioning and service options available upon request;
- Free provision of fire point layout drawings and linkage strategy configuration plans as needed.
11. Contact & Order Information
To place an order or request further information regarding the KITOZER Data Center Fire Alarm Linkage Monitoring System, please contact the KITOZER sales team through the official website: gdlain.com. All inquiries will receive a response within 24 hours. Customization, OEM manufacturing, and confidentiality agreements are also supported.
12. SEO Keywords & Tags
Data center fire alarm linkage monitoring system, very early aspirating smoke detector, VESDA detector, fire alarm host integration gateway, fire alarm video linkage system, KITOZER fire alarm software, IDC data center fire pre-warning monitoring, gas suppression status monitoring, KITOZER quotation, data center fire monitoring price list, factory price fire alarm linkage system, wholesale fire alarm monitoring quotation, data center fire alarm system cost, fire alarm linkage platform manufacturer, server room fire monitoring system supplier