2. Project Requirement Description
The client requires a complete, dedicated environmental monitoring system for archival repository rooms, strictly compliant with the national archives “Eight-Protection” standard (protections against fire, water, dampness, mold, insects, light, dust and theft). Key requirements are listed below:
- 24/7 real-time monitoring of repository temperature, humidity, formaldehyde, TVOC, PM2.5, CO₂, water leakage and smoke.
- Automatic linkage control: when temperature or humidity exceeds the standard range, the system automatically activates dehumidifiers and constant-humidity purification equipment.
- Local data storage of at least 180 days, with remote viewing supported on PC and mobile devices.
- Automatic generation of temperature and humidity trend curves.
- Multi-level alarm notification via SMS, audible-visual alarm on site, and platform pop-up.
- Dual-backup transmission: wired PoE plus wireless.
- Equipment must feature high precision and low drift, suitable for document archives, object archives and electronic archives repositories.
- No confidentiality restrictions; applicable to general archives institutions and enterprise/institutional archive rooms.
3. System Composition Introduction
The complete system consists of four layers:
- Perception Layer: high-precision PoE temperature & humidity sensors, archive-specific harmful gas sensors, water leakage rope detection modules, aspirating smoke detectors, and differential pressure sensors.
- Transmission Layer: PoE industrial switches, LoRa wireless gateways, and 4G backup transmission modules.
- Control Layer: environment linkage control cabinets, relay output modules, and audible-visual alarm devices.
- Management Layer: archive room dynamic environment monitoring software, local touch display terminals, data storage hosts, and SMS alarm units.
4. Core Product Specifications & Parameters
- KT-DA-TH-POE High-Precision Archives Temperature & Humidity Sensor (PoE): temperature range 10~26°C, accuracy ±0.2°C; humidity range 40~65%RH, accuracy ±2%RH; PoE network cable power supply; TCP/IP communication; adjustable sampling period from 10s; IP65 dustproof and moisture-proof.
- KT-DA-GAS04 Archive-Specific Four-in-One Gas Sensor: measures formaldehyde 0~1 mg/m³, TVOC 0~10 mg/m³, CO₂ 0~3000 ppm, PM2.5 0~999 μg/m³; electrochemical sensing; resistant to interference from volatile emissions of archival paper.
- KT-DA-WL01 Water Leakage Detection Rope: sensing length 10 meters, triggers alarm immediately upon water contact; passive dry-contact output; laid along the base of mobile shelving.
- KT-DA-SO02 Aspirating Smoke Detector: aspirating sampling distance ≤5 m; sensitivity 0.01 dB/m; early warning for low-concentration smoke; suited for sealed archives repositories.
- KT-DA-SOFT Archive Room Dynamic Environment Monitoring Software V2.0: supports unlimited repository points; temperature/humidity curves automatically exportable to Excel; over-limit logs permanently retained; supports linkage logic settings for dehumidification and air-conditioning equipment.
- KT-GW-LR03 LoRa Wireless Gateway: supports up to 32 node connections; wireless backup transmission; dual-band operation.
- KT-SW-POE24 24-Port PoE Industrial Switch: IEEE 802.3af PoE standard; surge protection; DIN-rail mounting.
- KT-CAB-DA08 Environment Linkage Control Cabinet: 8-channel relay output; supports linkage with dehumidifier and air conditioner; IP54 protection rating.
- KT-DIS-15 15-Inch Industrial Touch Display Terminal: local real-time data display; wall-mount installation.
- KT-AL-SMS04 4G SMS Alarm Module: pushes alarms simultaneously to multiple numbers; power-off data caching.
- KT-AL-SG03 High-Decibel Audible-Visual Alarm: 85 dB alarm volume; red warning light; 24V supply.
- KT-DA-CY01 Repository Differential Pressure Sensor: measurement range 0~500 Pa; monitors repository sealing differential pressure.
5. Core Functions & Features of Products
- 24-hour uninterrupted collection of full-dimensional environmental data in the repository: temperature, humidity, harmful gases, particulate matter, water leakage and smoke.
- When temperature and humidity deviate from the archival standard range, commands are automatically issued to link and control dehumidifiers, humidifiers and fresh-air purification equipment.
- Water leakage, smoke or gas over-limit triggers three-level alarm: local audible-visual alarm, mobile SMS, and background platform pop-up.
- Per-repository zone management with independently configurable upper/lower alarm thresholds for temperature and humidity.
- Historical data stored for 180 days; automatic monthly and quarterly archival environment preservation reports, meeting archive inspection requirements.
- PoE network cable power supply: a single cable delivers both power and data, reducing cabling and installation work.
- Offline local data buffering; automatic retransmission upon network recovery — zero data loss risk.
- Mobile mini-program allows remote real-time viewing of repository environment, historical curve playback, and alarm record queries.
6. Core Advantages of The Solution
- Sensors specially optimized for archives repositories, suppressing data drift caused by volatile emissions from paper and adhesives, ensuring long-term monitoring stability.
- Dual wired + wireless link transmission with automatic switching upon single-line failure, guaranteeing uninterrupted monitoring in sealed repositories.
- Low-power industrial terminals capable of 7×24 continuous operation, with mean time between failures (MTBF) ≥100,000 hours.
- Software pre-loaded with national archival repository temperature and humidity standard thresholds — out-of-the-box operation with no manual configuration required.
- Modular equipment design allows flexible expansion — new repositories can be added without replacing core host hardware.
- All equipment features moisture-proof and dust-proof enclosures, adapted to long-term sealed, high-humidity archives repository environments.
- Full compliance with National Archives Administration repository environment construction specifications; complete acceptance test documentation supplied for archive project handover.
- KITOZER full-series in-house manufacturing; imported and calibrated sensor chips; measurement accuracy superior to general industry equipment.
- Integrated hardware-software linkage — automatic regulation is achieved without any retrofitting of existing dehumidifiers or air-conditioning equipment.
- Software provides permanent license with no annual fee; supports multi-account hierarchical management and permission isolation for repository administrators.
- Supports integration with archive comprehensive management platforms, enabling unified archives business + environmental monitoring integration.
- Alarm messages are pushed in hierarchical classes, distinguishing general warnings from high-risk events, avoiding nuisance notifications.
7. Manufacturer Strength Introduction
KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.) is a professional industrial monitoring equipment manufacturer founded in 2002. Key strengths include:
- Long-term supply to archives at all levels across the country as well as enterprise and institutional archive rooms, with mature archive monitoring solutions.
- Sensors fully self-calibrated before delivery; every device ships with an individual accuracy inspection report, ensuring trouble-free acceptance.
- Free on-site survey and point-layout planning for archives repositories, with standard archive monitoring construction drawings provided.
- 24-month product warranty, annual free calibration guidance for sensors, and lifetime remote maintenance and debugging.
- In-house sheet-metal workshop enables custom sizing and labeling of linkage control cabinets and sensor housings.
- 7×24 technical after-sales support; expedited supply for archive projects with priority production and delivery.
- ISO 9001 / 14001 / 45001 certified high-tech enterprise; project-confirmed manufacturing with complete quality inspection before shipment.
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | POE High-Precision Archives Temperature & Humidity Sensor | KT-DA-TH-POE | ±0.2°C accuracy, PoE power supply, TCP/IP, IP65 | 36 | PCS | 219.33 | 7,895.81 | KITOZER | 1 per 50 m², densified deployment in mobile shelving area |
| 2 | Archive-Specific Four-in-One Gas Sensor | KT-DA-GAS04 | Formaldehyde / TVOC / CO₂ / PM2.5 four parameters, anti paper volatiles | 12 | PCS | 320.56 | 3,846.59 | KITOZER | Deployed at repository vents and dense archive areas |
| 3 | 10m Water Leakage Detection Rope Kit | KT-DA-WL01 | Sensing rope 10m/set, leak relay output | 18 | SET | 127.87 | 2,301.61 | KITOZER | Laid on floor beneath AC and dehumidifiers |
| 4 | Aspirating Smoke Detector | KT-DA-SO02 | Sampling distance 5m, low-concentration smoke pre-alarm, DC24V | 9 | PCS | 628.68 | 5,658.19 | KITOZER | Full ceiling coverage above mobile shelving |
| 5 | LoRa Wireless Transmission Gateway | KT-GW-LR03 | 32-node access, wireless backup transmission, dual-band | 3 | PCS | 618.91 | 1,856.74 | KITOZER | Aggregates wireless sensors where cabling is difficult |
| 6 | 24-Port PoE Industrial Switch | KT-SW-POE24 | 802.3af PoE, surge protection, DIN-rail mount | 2 | PCS | 1,020.28 | 2,040.55 | KITOZER | Centralized powering and networking for all PoE sensors |
| 7 | Repository Environment Linkage Control Cabinet | KT-CAB-DA08 | 8-channel relay output, links dehumidifier/AC, IP54 | 6 | PCS | 832.91 | 4,997.40 | KITOZER | Independent linkage control per repository |
| 8 | Archive Room Dynamic Environment Monitoring Software V2.0 | KT-DA-SOFT-V2 | Unlimited repository points, report export, permanent license | 1 | SET | 11,387.30 | 11,387.30 | KITOZER | Full PC + mobile mini-program license |
| 9 | 15-inch Industrial Touch Display Terminal | KT-DIS-15 | Local real-time data display, wall-mount installation | 2 | PCS | 1,608.11 | 3,216.22 | KITOZER | 1 each in archive management room and duty room |
| 10 | 4G SMS Alarm Module | KT-AL-SMS04 | Multi-number simultaneous alarm push, power-off cache | 3 | PCS | 539.89 | 1,619.65 | KITOZER | Simultaneous alerting to duty staff mobile phones |
| 11 | High-Decibel Audible-Visual Alarm | KT-AL-SG03 | 85dB alarm volume, red warning light, 24V | 6 | PCS | 118.10 | 708.60 | KITOZER | Local audible-visual alert at each repository entrance |
| 12 | Repository Differential Pressure Sensor | KT-DA-CY01 | 0-500Pa, monitors repository sealing differential pressure | 9 | PCS | 139.41 | 1,254.70 | KITOZER | Supplement at repository ventilation windows/doors |
Total Quotation Price: USD 46,783.36
9. Quotation Terms & Conditions
- Prices are quoted in USD, EXW Guangzhou, China (or as negotiated).
- The total price excludes taxes and freight. A special VAT invoice adds 10% (approximately USD 51,542.02); an ordinary VAT invoice adds 3% (approximately USD 48,267.50).
- Payment terms: 30% deposit / 70% balance before shipment (negotiable).
- Delivery lead time: 15–30 working days depending on configuration.
- Validity of this quotation: 30 days.
- Packing and shipping costs are quoted separately.
- Cables, installation auxiliary materials, and on-site construction services can be supplied as a separate supplemental quotation as required.
- Equipment warranty: 24 months, including a full set of technical documentation for archive project acceptance.
10. After-sales Service Description
- 24-month product warranty with lifetime technical support.
- Annual free calibration guidance for all sensors.
- Lifetime remote maintenance and debugging service.
- Spare parts guaranteed available for all listed products.
- Remote troubleshooting and on-site service options both available depending on project requirements.
11. Contact & Order Information
Orders may be placed through the official KITOZER website at gdlain.com or by contacting the KITOZER international sales team directly. All inquiries receive a response within 24 hours. For this quotation and related technical documentation, please quote the reference “Archives Room Environmental Monitoring System — Complete Set” together with your project details.
12. SEO Keywords & Tags
KITOZER quotation, archives room environmental monitoring system price list, archive repository temperature and humidity monitoring system, archives eight-protection monitoring equipment, document archives harmful gas monitoring terminal, repository dynamic environment monitoring system, constant temperature and humidity automatic linkage monitoring equipment, archival preservation environment online monitoring device, KITOZER archive monitoring equipment, Guangzhou Lai’an archives room environmental monitoring system, archives room temperature and humidity monitoring equipment cost, archives repository dynamic environment monitoring manufacturer quotation, wholesale archives room environmental monitoring system, high-precision PoE temperature and humidity sensor quotation, archive room monitoring system factory price.