Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Building Energy Efficiency Monitoring System

KITOZER Building Energy Efficiency Monitoring System Quotation List

Building Energy EfficiencyMonitoringSystem
Building Energy EfficiencyMonitoringSystem

2. Project Requirement Description

This solution is tailored for the energy efficiency monitoring of a medium-sized public building with a total floor area of approximately 50,000 m². The project requirements are as follows:

  • Automatic acquisition of sub-metered energy consumption data for electricity, water, gas, and cooling/heating.
  • Real-time monitoring, statistical analysis, and reporting of energy consumption data.
  • Deployment of a complete energy monitoring platform, metering instruments, data acquisition equipment, and transmission infrastructure.
  • Compliance with national technical standards for public building energy consumption monitoring systems.
  • Support for building energy efficiency management and policy compliance.

3. System Composition Introduction

The KITOZER Building Energy Efficiency Monitoring System adopts a three-tier architecture, comprising the data management layer, network transmission layer, and data acquisition layer. Core components include:

Data Management Layer:

  • Energy monitoring server
  • Energy monitoring management platform software
  • Operator workstation

Network Transmission Layer:

  • Data acquisition units
  • Communication gateways
  • Network switches
  • Transmission network infrastructure

Data Acquisition Layer:

  • Smart electricity meters
  • Smart water meters
  • Cooling/heating energy meters
  • Gas meters
  • Environmental monitoring instruments

Supporting Components:

  • Metering enclosures
  • Power supply modules
  • Cabling and auxiliary materials
  • Installation accessories

4. Core Product Specifications & Parameters

The project quotation is based on the following technical standards and specifications:

  • JGJ/T 285-2014 – Technical Standard for Building Energy Consumption Monitoring System
  • GB 50314-2015 – Standard for Design of Intelligent Building
  • DL/T 448-2016 – Technical Administrative Code of Electric Energy Metering Device
  • GB 17167-2006 – General for Equipping and Managing of the Measuring Instruments of Energy in Organization of Energy Using Unit
  • KITOZER internal technical and production standards for building energy efficiency monitoring systems

Core Equipment Technical Parameters:

Equipment Key Specifications
Energy Monitoring Server 2U rack-mounted; CPU ≥ 6 cores @ 2.4GHz; RAM ≥ 16GB; Storage ≥ 4TB enterprise-grade HDD; Dual Gigabit Ethernet ports; RAID1 support; 7×24-hour stable operation
Energy Monitoring Platform Software B/S architecture; supports categorized and sub-itemized energy statistics for electricity, water, gas, cooling/heating; real-time monitoring, energy analysis, report generation, alarm management, and data upload; complies with national energy monitoring platform data upload standards
Multi-function Smart Electricity Meter Three-phase four-wire; accuracy class 0.5; measures voltage, current, power, energy, power factor, etc.; RS485 communication; Modbus-RTU / DL/T645 protocol; DIN-rail mounting
Smart Remote-reading Water Meter Vane-wheel type; accuracy class 2; pulse/RS485 output; cumulative flow metering; IP68 protection rating; suitable for main water inlet and zonal metering
Energy Data Acquisition Unit Industrial-grade design; supports 8 RS485 channels; connects up to 32 metering instruments per unit; data buffering and resume-transfer on interruption; Ethernet/4G uplink

5. Core Functions & Features of Products

System Functions

  • Categorized & Sub-itemized Energy Monitoring: Real-time acquisition of electricity, water, gas, and cooling/heating consumption data; sub-itemized statistics and display by building zone and system type.
  • Energy Statistical Analysis: Daily, monthly, and annual energy statistics; year-on-year and month-on-month comparison; energy consumption per unit area analysis; energy ranking; identification of energy-saving potential.
  • Energy Alarm Management: Alarms for energy over-limit, equipment abnormality, data transmission interruption, etc.; notifications via pop-ups and message push.
  • Energy Report Generation: Automatic generation of various energy statistics reports; Excel export support; meets daily energy management and reporting requirements.
  • Data Upload & Integration: Supports integration with provincial/municipal public building energy monitoring platforms; standard-compliant energy data upload; meets policy compliance requirements.
  • Carbon Emission Statistics: Automatic calculation of carbon emissions based on energy consumption data; building-level carbon emission statistics; supports dual-carbon goals.
  • Energy-saving Effect Evaluation: Comparison of pre- and post-retrofit energy data to quantitatively assess the actual effectiveness of energy-saving measures.

System Features

  • Strong Compliance: Fully complies with national and local technical standards for building energy monitoring; seamless integration with official energy platforms.
  • Accurate Metering: High-precision metering instruments ensure minimal data acquisition error and reliable energy data.
  • Reliable Transmission: Supports resume-transfer and data buffering; local data storage during network interruptions with automatic upload after recovery – no data loss.
  • Excellent Scalability: Modular design allows adding metering points and energy types at any time; adapts to future metering expansion.
  • Flexible Deployment: Supports both wired and wireless transmission modes; suitable for both retrofitted existing buildings and new construction.

6. Core Advantages of The Solution

  • Regulatory Compliance: Helps buildings meet national and local energy monitoring policy requirements, avoiding compliance risks.
  • Energy Management Support: Identifies high energy consumption points through refined data analysis, providing a data foundation for energy-saving retrofits.
  • Reduced Management Costs: Automatic meter reading and statistics replace manual meter reading, significantly reducing energy management labor costs.
  • Full Data Traceability: Complete historical energy data storage; auditable and traceable data to meet energy management system requirements.
  • Excellent Overall Cost-performance: Self-developed integrated software and hardware solution with low deployment cost, simple O&M, and low long-term operating cost.

7. Manufacturer Strength Introduction

KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.) is a professional manufacturer of intelligent building and industrial automation products, established in 2002. Key strengths include:

  • ISO 9001 / ISO 14001 / ISO 45001 certified management systems.
  • Recognized as a National High-Tech Enterprise.
  • Project-confirmed manufacturing with full-process quality control.
  • In-house R&D team with independent intellectual property rights.
  • OEM/ODM services available for energy monitoring equipment and platforms.
  • Complete quality inspection before shipment to ensure product reliability.
  • Standard inventory of common metering instruments and acquisition equipment to guarantee delivery lead times.
  • Strict confidentiality mechanism to protect project energy data and client information.

8. Detailed Quotation Table

Exchange rate: 1 CNY = 0.14802 USD (1 USD = 6.7570 CNY)

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Energy Monitoring Server KTR-EM-S01 2U rack-mounted, 6-core 2.4GHz CPU, 16GB RAM, 4TB enterprise HDD, dual Ethernet ports 1 Unit 3330.05 3330.05 KITOZER Data management core
2 Building Energy Monitoring Platform Software KTR-EM-V1.0 B/S architecture, categorized sub-itemized energy statistics, with analysis, report, alarm, and upload functions 1 Set 12433.92 12433.92 KITOZER Permanent license, 1 year free upgrade
3 Operator Workstation KTR-EM-W01 Desktop PC, 6-core CPU, 8GB RAM, 512GB SSD, 23.8-inch monitor 1 Unit 1420.75 1420.75 KITOZER Operation & maintenance terminal
4 Three-phase Multi-function Electricity Meter KTR-EM-E01 Three-phase four-wire, class 0.5, full electrical parameter measurement, RS485 communication, DIN-rail mounting 24 Unit 106.56 2557.34 KITOZER Electricity sub-metering
5 Smart Remote-reading Cold Water Meter KTR-EM-W01 DN100, vane-wheel type, class 2 accuracy, RS485 output, IP68 protection 4 Unit 266.39 1065.56 KITOZER Water zone metering
6 Cooling/Heating Energy Meter KTR-EM-H01 DN80, ultrasonic type, class 2 accuracy, cooling/heating metering, RS485 communication 2 Unit 532.78 1065.56 KITOZER HVAC cooling/heating metering
7 Energy Data Acquisition Unit KTR-EM-C01 8 RS485 channels, connects up to 32 meters, data buffering, Ethernet upload 6 Unit 399.59 2397.51 KITOZER Data acquisition & upload
8 Metering Distribution Enclosure KTR-EM-B01 500×600×200mm, cold-rolled steel plate with plastic spraying, includes circuit breaker and terminal blocks 6 Unit 155.40 932.37 KITOZER Acquisition equipment installation
9 Access Switch KTR-EM-N01 24-port Gigabit, Layer 2 managed, rack-mount type 2 Unit 443.99 887.98 KITOZER System transmission network
10 System Supporting Accessories KTR-EM-F01 Includes communication cables, power cables, wiring terminals, surge protection modules, labels, etc. 1 Batch 2663.90 2663.90 KITOZER Project installation support

Total Quotation Price: USD 28755.80

9. Quotation Terms & Conditions

1. Currency: All prices are quoted in US Dollars (USD).

2. Price Basis: Prices are EXW Guangzhou, China unless otherwise negotiated.

3. Tax: The quotation excludes tax and freight. If a VAT special invoice is required, an additional 10% of the tax point will be charged; if a VAT general invoice is required, an additional 3% of the tax point will be charged.

4. Freight: Products will be shipped via logistics; freight cost is to be collected (payable upon delivery).

5. Payment Terms: 30% deposit upon order confirmation, 70% balance before shipment. Payment terms are negotiable for long-term cooperation.

6. Lead Time: 15–30 working days after deposit confirmation, depending on configuration and quantity.

7. Quotation Validity: This quotation is valid for 30 days from the date of issue.

8. Packing & Shipping: Packing and shipping costs are quoted separately based on destination and shipment method.

10. After-sales Service Description

  • Warranty Period: Products are covered by a 1-year warranty from the date of delivery. During the warranty period, technical support and fault repair services are provided free of charge.
  • Extended Warranty: 12–24 months warranty available depending on product category.
  • Lifetime Technical Support: Free lifelong technical consultation and remote troubleshooting support.
  • Spare Parts Availability: Regular spare parts inventory maintained to ensure rapid replacement.
  • Remote Support: Remote diagnosis and troubleshooting available via phone, email, or remote desktop.
  • On-site Service: Field commissioning, installation guidance, and on-site repair services available upon request.

11. Contact & Order Information

To place an order or request more information, please contact the KITOZER sales team:

  • Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Equipment Room Equipment Co., Ltd.
  • Brand: KITOZER
  • Official Website: www.gdlain.com
  • Contact Person: Mr. Zhou
  • Contact Number: 13538869979 (also available on WeChat)
  • Factory Address: Chaitian Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

All inquiries will receive a response within 24 hours.

12. SEO Keywords & Tags

KITOZER quotation, building energy efficiency monitoring system quotation, public building energy monitoring system price list, building energy consumption monitoring system configuration, building energy monitoring system manufacturer, KITOZER building energy monitoring, energy metering system quotation, building energy management system price, wholesale building energy monitoring system quotation, building energy efficiency monitoring system cost, energy monitoring platform price, sub-metering system quotation

Scroll to Top