KITOZER
KITOZER

KITOZER Busbar: 630A High Density Modular Busway

Product Overview

KITOZER 630A high density modular busway is designed for large data centers, industrial plants, and commercial buildings where high current must be distributed with safety and flexibility. At 630A per phase, the busbar supports full data hall power demands including IT loads, air conditioning, and lighting. The modular system allows straight sections, elbows, tees, and feed-in units to be assembled on site without specialized tooling. Tap-off boxes up to 400A can be inserted while the busbar is energized, making the system ideal for phased commissioning and future expansion.

Technical Specifications

Rated current 630A at 400V three phase, copper conductor with high-concentration alloy to limit skin effect losses. Standard straight section 2 meters, with horizontal and vertical elbows available. Tap-off boxes in 63A, 125A, 250A, and 400A ratings with MCCB or fuse protection. Protection IP30 trunking, IP44 tap-off. Short-time withstand 50kA for 1 second, peak 105kA. Insulation class F, flame retardant UL94 V0 coating. CE and IEC 61439-2 certified. Optional integrated current transformers per phase for metering, and Modbus TCP communication for upstream BMS. Housing is heavy-gauge galvanized steel with powder coat.

Application Scenarios

The 630A busway is commonly used as the main distribution backbone in hyperscale data centers, semiconductor cleanrooms, and large manufacturing plants. It feeds multiple sub-busways, UPS systems, and large motor control centers. In commercial high-rise buildings, it runs vertically through shafts to feed floor switchboards. Because tap-off boxes can be sized independently, a single run can serve both small loads (lighting, outlets) and large loads (chillers, UPS) without separate cabling.

Advantages and Features

The most visible benefit is space savings. A 630A busway occupies far less room than equivalent cable bundles in tray. The modular design reduces on-site fabrication, lowering installation labor and shortening project schedules. Joints are pressure-controlled with visible torque markers, and each joint is tested at the factory before shipment. Tap-off boxes include integrated isolation that meets arc-flash safety requirements. With optional metering, operators can measure load at each tap-off point and balance phases remotely. The system is also designed for easy disassembly and relocation if a facility is reconfigured.

Installation and Maintenance Recommendations

Because of the high current rating, installation must follow a strict lifting and alignment procedure. Use the provided joint plates and torque bolts, and do not overtighten. Maintain required clearance from combustible materials and follow local electrical code for vertical shaft installations. After energization, perform a full infrared scan under at least 60 percent load. Routine maintenance includes thermography every six months, joint torque check every year, and tap-off contact cleaning every two years. Keep a digital log of all tap-off positions and load values so that future expansions can be planned without overloading existing sections.

Price

From $1,580 per meter including 250A tap-off boxes. Contact +86 13922289957 for large project busway engineering support.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart