KITOZER 400kVA Dry Type Transformer 10kV IP23 for Industrial Plants

Product Overview

The KITOZER 400kVA dry type transformer is a medium voltage to low voltage distribution unit engineered for industrial plants, manufacturing workshops, and commercial complexes requiring robust power conversion without oil fire risk. The vacuum cast epoxy resin windings offer excellent electrical insulation, mechanical strength, and resistance to moisture and pollution. The core uses step lap mitered silicon steel to minimize no load loss and audible noise. KITOZER supplies the transformer as a core coil assembly with IP00 protection or fully enclosed in a sheet steel IP23 cabinet with filtered ventilation, making it suitable for dusty factory environments and indoor substation rooms.

Technical Specifications

Rated capacity is 400kVA at 50Hz, primary voltage 10kV with plus or minus 2 by 2.5 percent off circuit taps, secondary voltage 400V. Vector group Dyn11, impedance voltage 6 percent, insulation class F with 100K rise. Cooling is AN standard with optional AF forced air fans enabling 140 percent load. Protection enclosure IP23 as standard, optional IP00, IP21, IP31. Temperature control unit supports PT100 sensors, three stage alarm, fan control, and dry contact trip. Sound level is below 58dB at one meter. Routine tests include induced over voltage, applied voltage, partial discharge below 10pC, no load and load loss measurement. Weight is approximately 1950kg, dimensions 1600mm by 1000mm by 1650mm. Standards: IEC 60076, GB/T 1094, GB/T 6451, CE.

Application Scenarios

This 400kVA unit is suited for automotive factories, food and beverage processing lines, textile mills, electronics assembly plants, convention centers, airport terminals, and underground railway stations. It feeds LV motor control centers, distribution panels, HVAC systems, and lighting loads. Because it is dry type, it can be placed inside production areas or adjacent to load centers to reduce cable loss. The IP23 enclosure protects against vertical water spray and foreign objects larger than 12.5mm, making it acceptable in light industrial environments.

Advantages and Features

The encapsulated winding prevents dust and conductive contaminants from degrading insulation life. The low loss core meets Tier 2 efficiency, reducing annual transformer loss expenses. The Dyn11 connection suppresses triplen harmonics common in rectifier and LED lighting loads. The thermal controller can be wired to the plant SCADA via RS485 Modbus to monitor winding temperature, fan status, and alarm history. KITOZER offers optional space saving low noise variant for office adjacent installations and a stainless steel enclosure for coastal or chemical environments. Each transformer is factory tested and supplied with a test report.

Installation and Maintenance

Site preparation requires a reinforced concrete plinth with vibration isolation pads. Maintain 800mm front and rear clearance for HV and LV cable termination. Ensure ambient temperature remains below 40 degrees Celsius and relative humidity below 95 percent. Connect grounding busbar to plant earth grid with less than 4 ohm resistance. Inspect annually: clean ventilation filters, torque HV and LV cable lugs, verify PT100 sensors, and record winding resistance. Reapply touch up paint if enclosure coating is damaged. KITOZER recommends a thermal imaging scan during peak load season to detect hot spots on busbars and connections.