KITOZER
KITOZER

KITOZER UPS Parallel Cabinet: 2 Unit 100kVA Parallel System

Product Overview

KITOZER 100kVA UPS parallel cabinet allows two 50kVA UPS modules to operate in parallel for redundancy and capacity scaling. With parallel operation, load is shared evenly between units, and if one UPS fails the other takes the full load without interruption. The cabinet houses the parallel bus, output breaker, synchronization wiring, and maintenance bypass, simplifying installation and reducing cabling errors. It is designed for medium data centers, industrial plants, and commercial facilities that need N+1 redundancy without the cost of a single large UPS.

Technical Specifications

Rated total power 100kVA (2 x 50kVA), three phase 400V. Input: two UPS feeds, utility bypass. Output: single bus to load. Output breaker 160A. Parallel synchronization board for load sharing within 5 percent. Maintenance bypass interlocked. LED mimic showing each UPS status, load share, and bypass position. Remote monitoring via dry contacts and Modbus. IP20 floor cabinet 800x1000x600mm. CE, IEC 62040. KITOZER, 5 year warranty. Compatible with KITOZER and third-party 50kVA online UPS.

Application Scenarios

Parallel cabinets are used in facilities that cannot afford single-UPS downtime but also cannot justify a huge standalone unit. Typical sites include enterprise data centers, hospital IT rooms, manufacturing control rooms, and broadcast facilities. N+1 redundancy means that one UPS can be serviced while the other carries the load. As capacity grows, additional UPS modules can be added up to the parallel limit. This pay-as-you-grow model matches phased IT expansion.

Advantages and Features

Parallel operation gives both redundancy and scalability. Load sharing ensures neither unit is overloaded during normal operation. The cabinet pre-wires synchronization cables, eliminating complex field wiring. The mimic panel shows which UPS is online, load share percentage, and whether the system is on bypass. Maintenance bypass allows isolation of one UPS at a time. Modbus integration lets operators monitor load share and alarm status remotely. KITOZER cabinet is sized to fit through standard doorways.

Installation and Maintenance Recommendations

Place the cabinet between the two UPS units and the output distribution panel. Connect parallel communication cables per manual, using shielded cable and proper grounding. Verify load share balance under 50 percent and 100 percent load during commissioning. Test redundancy by switching off one UPS and confirming the other takes over without load interruption. Annual maintenance includes testing breakers, checking parallel communication, and verifying load share. Keep spare communication boards on site.

Price

From $4,800 per parallel cabinet including 2 UPS positions. Contact +86 13922289957 for parallel system pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com