KITOZER SPD: 60kA Type 2+3 Combined Data Center

Product Overview

KITOZER 60kA combined Type 2+3 SPD integrates two protection stages in one enclosure, simplifying data center panel design. It handles both high-energy surge currents from the distribution network and residual fast transients from equipment switching. This combined device reduces panel space, simplifies wiring, and ensures coordination between stages. The plug-in modules and remote signaling make maintenance straightforward. It is ideal for UPS input panels, server room distribution, and critical industrial control boards where space is limited but protection must be robust.

Technical Specifications

Rated voltage 230/400VAC, maximum continuous operating voltage 385VAC. Type 2 stage: In 30kA, Imax 60kA (8/20 microsecond). Type 3 stage: In 10kA, voltage protection level Up less than 1.5kV. Response time less than 25 nanoseconds. Configuration 3P+N or 4P. DIN rail or panel mount. Thermal disconnector per stage, visual indicator per stage. Remote signaling contact. CE, IEC 61643-11, RoHS. KITOZER, 5 year warranty.

Application Scenarios

This combined SPD is used in UPS input panels, server room distribution boards, and industrial control cabinets. It is a good fit for edge data centers, telecom huts, and broadcast rooms where a single board must provide both Type 2 and Type 3 protection. In retrofit projects, it replaces two separate SPDs, freeing panel space. It is also used in critical process panels where any surge event could cause downtime.

Advantages and Features

The main benefit is coordinated protection in one unit. Factory coordination between stages ensures energy is shared correctly, eliminating guesswork. Two visual indicators show the health of each stage separately, so operators know which module to replace. Compact width saves panel space. Remote signaling sends both stage statuses to BMS. Plug-in modules allow replacement without disconnecting wiring. The device is suitable for both TT and TN systems.

Installation and Maintenance Recommendations

Mount in the distribution board with short input and earth cables. Install upstream back-up protection (gG or aR fuse) per the manufacturer instruction. Verify configuration matches the earthing system. Test remote contact and indicators. Inspect annually, and replace modules when any stage shows red. After a major surge event, replace the Type 2 stage even if indicators appear green, because energy handling capacity degrades. Keep spare modules on site.