KITOZER Smart PDU: 24 Outlet Switched Monitored Three Phase

Product Overview

KITOZER 24 outlet switched and monitored smart PDU is the high-density model for large server racks and AI training clusters. It combines 24 IEC outlets with per-outlet switching, per-outlet current measurement, three phase input, and network management. Operators can reboot individual servers, measure energy per outlet, set load thresholds, and sequence rack power on startup. The PDU is designed for racks drawing 10kW to 20kW, where a basic strip would overload and a monitored-only unit would lack control.

Technical Specifications

Input 200 to 415VAC three phase 50/60Hz, rated current 63A per phase. 24 outlets configurable as C13, C19, or mixed, balanced across phases. Per-outlet relay switching 16A, per-outlet current measurement 2 percent. Total input metering 1 percent, voltage per phase, current per phase, active power, kWh, power factor. Temperature sensor on unit, optional 6 external probes. Communication 10/100/1000Mbps Ethernet, dual network ports for daisy chain, Modbus TCP, SNMP v3, HTTPS, email, alarm relay. Outlet grouping, sequence on/off, scheduling, and user roles. 0U vertical mount. CE, UL, RoHS. KITOZER, 5 year warranty.

Application Scenarios

This PDU is deployed in hyperscale server racks, AI and GPU training clusters, high-density compute pods, and large storage arrays. It supports remote reboot of failed nodes without sending technicians to the rack. Colocation providers use it for multi-tenant racks where customers request per-outlet control. In edge sites with limited access, it reduces truck rolls. It is also used in broadcast studios and production rooms where equipment must be cycled on a schedule.

Advantages and Features

The combination of switching and metering at every outlet gives operators both control and insight. Sequence-on logic prevents inrush when an entire rack is powered up after maintenance. Dual network ports allow daisy chaining, reducing switch port count. User roles prevent accidental shutdown of critical equipment. The web dashboard shows a real-time power map with outlet states and currents. KITOZER firmware supports automated actions, such as cycling an outlet if current drops to zero. Energy data feeds into DCIM for capacity planning and chargeback.

Installation and Maintenance Recommendations

Mount vertically at the rear of the rack, and route input cable with appropriate strain relief. Wire three phase input to the correct terminals, and verify phase rotation. Configure network, users, and thresholds before connecting servers. Label outlets clearly and maintain a mapping document. Test switching sequence during commissioning. Inspect relays and contacts every two years, and replace any outlet with erratic behavior. Keep firmware updated and back up configuration files.