Product Overview

The KITOZER 1U steel blanking panel is a cost-effective thermal management accessory designed to fill unused rack U positions inside server cabinets. When empty rack units are left open, hot exhaust recirculates back to server inlets, creating hot spots and forcing CRAC units to over-cool the entire room. Installing blanking panels across every open U position seals the cabinet front, ensuring that cold air drawn through the perforated door passes only through installed IT equipment. This simple measure can reduce server inlet temperatures by 3 to 8 degrees Celsius and improve cooling efficiency by 10 to 15 percent. The KITOZER 1U panel is made from 1.0mm cold-rolled steel, powder-coated in RAL 9005 black or RAL 7035 grey, and supplied with captive screws for tool-less or screwdriver installation.

Technical Specifications

Height: 1U (44.45mm). Width: 19 inch rack mount, 482mm. Depth: 10mm. Material: 1.0mm cold-rolled steel SPCC. Finish: epoxy polyester powder coat, RAL 9005 black standard, RAL 7035 grey optional. Mounting: 19 inch L brackets front and rear, M5 cage nuts and screws included. Operating temperature: -10 to 70 degrees Celsius. Fire rating: self-extinguishing coating, UL 94 HB equivalent. Corrosion: salt spray 48 hours. Weight: 0.25 kg per panel. Compatibility: fits all standard 19 inch server cabinets, network racks, open frames, and KITOZER cabinets. CE, RoHS. KITOZER brand, 3 year warranty.

Applications

The 1U steel blanking panel is used in every type of 19 inch rack installation: server cabinets, network racks, patch panels, audio-video racks, security DVR racks, industrial control panels, and home server cabinets. It is mandatory in modern data center design guides including ASHRAE TC 9.9 and Uptime Institute recommendations. Typical applications include enterprise server rooms, colocation cages, telecommunications central offices, bank branch cabinets, hospital IT closets, school network racks, and factory automation control panels. The panels are also used as filler for cable management arms, PDU mounting positions, and blank spaces left after equipment upgrades.

Key Advantages

First, immediate hot-spot elimination: sealing open U positions prevents hot exhaust recirculation. Second, low cost: a few dollars per U position delivers measurable energy savings. Third, durable steel construction resists bending and stays flat for years. Fourth, powder-coated finish matches cabinet interiors and resists scratches. Fifth, captive screws allow fast installation and removal during re-cabling. Sixth, panels are stackable and reusable when equipment is moved. Seventh, the universal 19 inch design works with any cabinet brand.

Installation and Maintenance

Installation takes less than a minute per panel: slide the panel between the two front rack rails, align the M5 screw holes, and tighten the captive screws by hand or with a Phillips screwdriver. KITOZER recommends blanking every unused U position, both at the front and where visible at the rear, to complete the airflow seal. No maintenance is required beyond visual inspection during cabinet audits. Panels can be wiped with a dry cloth and reused when equipment is repositioned. KITOZER supplies panels in packs of 10, 50, or 100, with mixed U sizes available on request.

Price

From $3.50 per panel. Contact +86 13922289957 for bulk pricing on packs of 100 or more.