KITOZER KYN28-12 Medium Voltage Switchgear 10kV With Vacuum Breaker

Product Overview

The KITOZER KYN28-12 is a metal clad withdrawable medium voltage switchgear rated 12kV for 10kV distribution substations. The stationary cabinet houses a withdrawable vacuum circuit breaker truck, busbar compartment, cable compartment, and relay and meter compartment separated by metal partitions. KITOZER designs each switchboard with mechanical interlocks and electrical interlocks to enforce safe operating sequences, preventing breaker withdrawal when the circuit is live. The KYN28 is the most widely used 10kV switchgear in China and is exported to industrial projects worldwide.

Technical Specifications

Rated voltage 12kV, rated frequency 50Hz, rated current 630A, 1250A, 1600A, 2000A, 2500A. Short time withstand 20kA for 4 seconds, 31.5kA option. Peak withstand 50kA. Vacuum circuit breaker VS1 or VD4, 1250A or 2000A, 31.5kA breaking. Busbar copper, silver plated. Protection relay: microprocessor based overcurrent, earth fault, over voltage, under voltage, transformer differential option. Indoor installation, IP4X, metal clad. Panel dimensions 800mm wide by 1500mm deep by 2300mm high. Standards IEC 62271-200, GB 3906, CE.

Application Scenarios

KYN28-12 is used in 10kV incoming and outgoing feeders, transformer protection, capacitor bank switching, motor feeder protection, and generator outlet feeders. Typical sites include industrial plants, commercial building substations, data center HV switchrooms, water treatment plants, and mining substations.

Advantages and Features

Withdrawable breaker allows rapid exchange without bus shutdown. Five step interlock prevents unsafe operations. Vacuum breaker is maintenance free for 10000 operations. KITOZER offers options including a microcomputer protection relay with Modbus, cable room space heaters, live line display, and partial discharge monitoring. The compact 800mm width reduces switchroom footprint. Factory type tests include power frequency, impulse, and short circuit.

Installation and Maintenance

Install on a flat concrete floor with 1500mm front clearance for breaker truck withdrawal. Bond the switchgear to the station ground grid. Verify torque on busbar joints. Commissioning includes protection relay secondary injection, breaker timing test, and insulation resistance. Annual maintenance includes vacuum bottle leak check, contact resistance measurement, and breaker mechanical operation count. KITOZER recommends a 10 year major overhaul including auxiliary switch and spring charging motor check.

Price

From $3,880/panel. Contact +86 13922289957 for KYN28 pricing.