KITOZER
KITOZER

KITOZER GCS Low Voltage Withdrawable Switchboard 400V 3200A

Product Overview

The KITOZER GCS low voltage withdrawable switchboard is a modular metal enclosed distribution board rated 400V AC for industrial power distribution, commercial building mains, and data center LV switchgear. Each GCS panel combines a vertical busbar system with withdrawable functional units (feeder, motor control, capacitor compensation) that slide out on guide rails for maintenance without shutting down the main bus. KITOZER builds the GCS sheet steel cubicle with segmented compartments to reduce arc flash energy and to allow future circuit additions by simply plugging in a new module.

Technical Specifications

Rated voltage 400V three phase four wire, 50Hz. Rated current up to 3200A main bus, vertical bus 1000A per section. Short time withstand 50kA for 1 second, peak 105kA. Functional units: feeder MCCB 16A to 630A, motor starter with contactor and thermal overload, capacitor switching contactor or thyristor. Withdrawable unit position: connected, test, disconnected, with mechanical interlock. Protection degree IP30 front, IP2X rear. Panel width 800mm or 1000mm, depth 1000mm, height 2200mm. Standards IEC 61439-1 and -2, GB 7251, CE.

Application Scenarios

GCS switchboards are used in industrial plant LV mains, water pump stations, HVAC plants, commercial building distribution, and data center main switchboards. The withdrawable design is preferred in continuous process plants where feeder shutdowns must be minimized. It also supports large motor control centers with dozens of motor starters.

Advantages and Features

Modular functional units allow rapid reconfiguration. Arc resistant internal separation reduces personnel risk. KITOZER offers options including a power meter on each feeder, harmonic measurement, RS485 Modbus communication, and a 7 inch HMI at the main incoming panel. The copper busbar is silver plated at joints. Factory assembly and routine tests include dielectric, contact resistance, and insulation resistance.

Installation and Maintenance

Install panels on a flat concrete floor with front and rear walkways of at least 1000mm. Join panels with provided bolts and connect the horizontal busbar with torque controlled joints. Bond each cubicle to the building earth grid. Commissioning includes insulation resistance on each feeder, MCCB trip test, and protection coordination check. Annual maintenance includes torque check on busbar joints, contactor contact inspection, and heater element test. KITOZER recommends infrared thermography of busbar under full load.