Table of Contents
ToggleProduct Overview
The KITOZER FAHU 5000 m3/h is a larger packaged air handling unit designed for medium data halls, commercial buildings, and industrial process rooms requiring substantial fresh air. It integrates a cross-flow heat recovery wheel or plate core, supply and exhaust EC fans, G4 and F8 filtration, a six-row chilled water cooling coil with drain pan, optional heating coil, and a programmable controller. The unit delivers both ventilation and dehumidification in one package, maintaining data hall humidity at 40 to 60 percent RH even in humid climates. At 5000 m3/h, it serves rooms of 300 to 500 square meters or multiple containment aisles.
Technical Specifications
Airflow: 5000 m3/h. Heat recovery: rotary enthalpy wheel, efficiency 70 to 80 percent. Cooling coil: 6-row copper tube aluminum fin, 20 kW at 7/12 degrees Celsius chilled water. Drain pan: stainless steel with insulated slope. Fans: EC plug fans, 1.5 kW each. Filters: G4 + F8 + optional H13. External static: 500 Pa supply. Casing: double-skin 50mm insulated. Power: 400V three phase, 4 kW. Control: PLC with touchscreen, Modbus TCP, BMS. Noise: 62 dBA at 1 meter. Dimensions: 2400x1400x1800mm. Weight: 950 kg. CE, Eurovent. KITOZER brand, 2 year warranty.
Applications
The 5000 m3/h FAHU is used in enterprise data centers, colocation halls, office towers, shopping malls, hotel lobbies, hospital wards, factory assembly halls, museum atriums, and underground parking ventilation. In data centers, it provides outside air free cooling, humidity control, and positive pressure. The chilled water coil ties into the building chiller plant for dehumidification during humid summer months.
Key Advantages
First, enthalpy wheel recovers both sensible and latent energy. Second, integrated chilled water coil provides dehumidification. Third, EC fans with VFD save 40 percent at part load. Fourth, double-skin casing prevents condensation. Fifth, PLC control with weather logic optimizes free cooling. Sixth, BMS integration. Seventh, modular design allows coil additions. Eighth, low maintenance with accessible filters and drain pan.
Installation and Maintenance
Install on anti-vibration springs, connect chilled water piping with isolation valves and flexible hoses, and drain pan to floor drain. Commission: balance airflow, set enthalpy wheel schedule, verify coil delta T, and test freeze protection. Maintenance: G4 filter quarterly, F8 semi-annual, coil cleaning annually, wheel brush inspection yearly, and belt or motor check. KITOZER provides a maintenance manual and spare parts list.
Price
From $18,500 per FAHU including enthalpy wheel and chilled water coil. Contact +86 13922289957 for project quotation.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com