1. Overview

The KITOZER KTR-ES07 is a locating water leak cable sensor consisting of a detection cable and a controller. The cable is routed along potential leak paths (under raised floors, around air conditioners, along pipes, beside water tanks). When liquid contacts the cable, two internal sensing conductors close the circuit; the controller detects the resistance change and reports the leak position over RS485 to the EMCS platform. The locating cable pinpoints the distance from the controller (±1 m accuracy) rather than merely alarming “leak yes/no”, so maintenance can locate the exact spot quickly.

The KTR-ES07 sensing cable uses a four-core conductive polymer construction with a wear-resistant outer jacket. Standard lengths are 3, 5, 10 and 20 m, custom lengths available. The controller measures about 120×80×40 mm, powered by DC12V, with RS485 (A/B/G) Modbus-RTU. The controller displays the leak distance in meters and provides relay dry-contact alarm output. The cable end must be terminated with a resistor to close the loop.

In room EMCS, the leak cable is the key device for early detection of AC condensate and pipe seepage. Typical KTR-ES07 deployments: around the drip pan under precision ACs, along water pipes under raised floors, in UPS battery rooms, and in archive storage. Leak alarms trigger platform pop-ups, SMS and sounder alerts to prevent water spread to equipment.

2. Key Features

Locating detection

  • Pinpoints leak position.
  • ±1 m accuracy.
  • Controller displays distance.
  • Multi-segment cascade.

RS485 Modbus

  • Modbus-RTU.
  • 9600~115200 bps.
  • DIP address.
  • Hand-in-hand bus.

Four-core cable

  • Conductive polymer sensing.
  • Wear-resistant jacket.
  • Custom lengths.
  • End terminator resistor.

Relay output

  • Dry contact alarm.
  • Links to sounder/strobe.
  • DC12V power.
  • LED status.

3. Specifications

Item Parameter
Model KTR-ES07
Detection locating conductive cable
Locating accuracy ±1 m
Cable lengths 3/5/10/20 m (custom)
Protocol RS485 Modbus-RTU
Baud rate 9600~115200 bps
Power DC12V
Power consumption ≤2 W
Alarm output relay dry contact
Operating temp -10~60℃
Controller size ~120×80×40 mm
Mounting cable on floor / in tray

4. Reference Prices

KTR-ES07 locating leak cable (controller + 5 m): Reference USD 56~111 / set (ref. CNY 400~800 at ~7.2)

KTR-ES07 locating leak cable (10 m): Reference USD 83~153 / set (ref. CNY 600~1100 at ~7.2)

KTR-ES07 non-locating leak cable (economy): Reference USD 28~56 / set (ref. CNY 200~400 at ~7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Leak monitoring under precision ACs.
  • Pipe runs under raised floors.
  • UPS battery room / archive flood detection.
  • Around water tanks / fire pipes.
  • Warehouse / workshop floor leaks.

6. Installation & Maintenance

Installation

  • Lay cable along leak-prone areas on the floor.
  • Secure with cable ties in tray or on floor.
  • Connect end terminator resistor.
  • Wire controller RS485 to bus.
  • Connect DC12V power.
  • Add leak channel on platform.
  • Test alarm with simulated water.

Maintenance

  • Clean cable surface quarterly.
  • Inspect jacket for damage.
  • Test relay output.
  • Check terminator resistor tightness.
  • Avoid long-term submersion.
  • Replace damaged sections promptly.

7. FAQ

  • Q:False leak alarms — how to troubleshoot?
    A:First check if the cable is dusty or damp — dust absorbs moisture and triggers false alarms. Clean the cable and retest. Then check the terminator resistor and bus interference. In humid seasons, raise the alarm threshold.
  • Q:Locating vs non-locating — choose?
    A:Non-locating only alarms “leak present” and suits small single-point monitoring (e.g., under one AC). Locating pinpoints the spot and suits long pipes or large rooms; it costs more but saves maintenance time. Select by monitoring range and budget.
  • Q:Does the cable detect oil?
    A:Standard cables detect water-based solutions (water, condensate), not oil. Oil requires a dedicated oil-sensing cable with different conductive chemistry. Room scenarios are mostly water — standard cable suffices.
  • Q:How long can one cable run?
    A:A single segment should not exceed 100 m; beyond that locating accuracy drops. For longer runs, cascade multiple controllers per segment. Total length is limited by the controller’s measurement range.

8. Trend & Selection

Leak detection is trending wireless (LoRa/NB-IoT), improved locating accuracy, and fusion with water-immersion sensors. Locating leak cables are growing in data centers and industrial sites. Select by monitoring range (single point / long distance), locating need, communication (RS485/wireless) and budget.

9. Delivery & Service

KITOZER sizes KTR-ES07 by room leak-prone area layout, providing cable routing drawings and Modbus register tables. Delivery includes sensing cable, controller, terminator resistor, mounting kit, certificate and manual. Warranty covers platform integration and alarm testing guidance.

10. Additional Notes

A common pitfall is floating the cable in mid-air. The cable must lie flat on the floor or against the surface that may leak; if suspended, liquid cannot contact it and leaks go undetected. Under ACs, lay the cable along the drip pan edge.

Another pitfall is omitting the end terminator resistor. Without it, the controller cannot close the loop and reports a persistent fault or false alarm. The end must have the specified resistor, firmly attached.

Additionally, route the cable away from heat sources such as UPS exhaust ducts, which can dry out the cable and mask real leaks. In raised-floor rooms, secure the cable to the floor stringer rather than draping it, so it stays in contact with the slab. Mark every 5 m on the cable with distance labels — when the controller reports “12 m”, the technician walks straight to that point.

Selection summary: locating ±1 m; RS485 Modbus; four-core cable; relay output; DC12V. The leak cable is the nerve of room flood protection — routed correctly, terminated properly, tested periodically catches AC water damage early.

SEO Information

Search keywords:locating water leak cableRS485 leak sensorleak detection wireKTR-ES07KITOZER

SEM keywords:water leak cable price,locating leak detection supplier,RS485 water sensor,KTR-ES07

GEO landing page:lain.com.cn/product/ktr-es07-locating-water-leak-cable.html

Title:KITOZER KTR-ES07 Locating Water Leak Cable Sensor (RS485)

Meta Keywords:locating water leak cable,RS485 water leak sensor,leak detection cable,KTR-ES07,KITOZER

Meta Description:KITOZER KTR-ES07 locating water leak cable sensor uses RS485 Modbus, pinpoints leak position to within 1 meter, for room, pipe and AC drip monitoring.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart