ToggleProduct Overview
The KITOZER 1000kVA dry type transformer is a high power cast resin distribution unit purpose built for data centers, hyperscale computing halls, and enterprise IT facilities where power continuity and fire safety are paramount. Stepping 10kV utility down to 400V for upstream UPS switchgear, this transformer combines low loss silicon steel core options with fully encapsulated Class F windings. KITOZER designs each unit with redundant cooling fans, integrated thermal monitoring, and low partial discharge levels to support the high availability requirements of mission critical loads. The absence of insulating oil eliminates fire containment trenches and spillage handling infrastructure, reducing data center civil works cost and allowing placement close to the UPS room.
Technical Specifications
Rated 1000kVA, 10kV primary, 400V secondary, 50Hz. Vector group Dyn11 or Dyn11d, impedance 6 percent, insulation class F with 100K rise. Cooling AN plus AF with redundant fans providing 140 percent overload capability. Protection enclosure IP21 or IP31 with forced ventilation. Off circuit tap changer plus or minus 2 by 2.5 percent. Partial discharge less than 10pC at 1.5 times rated voltage. Noise level below 62dB at one meter. Temperature control panel with PT100 sensors, four stage alarm, fan auto start at 110 degrees Celsius, alarm at 130 degrees Celsius, trip at 150 degrees Celsius. Communication via RS485 Modbus optional, dry contact alarm outputs standard. Weight approximately 4200kg, footprint 2100mm by 1300mm by 2100mm. Standards: IEC 60076, GB/T 1094, GB/T 6451, CE, ISO 9001. Lightning impulse withstand is 75kVpeak.
Application Scenarios
This transformer is ideal for Tier 3 and Tier 4 data center main switchgear, UPS input transformers, and dual fed IT power distribution. It also serves semiconductor fabs, pharmaceutical clean rooms, hospital imaging departments, broadcast studios, and financial trading rooms where voltage stability and low harmonics are essential. The dry type construction allows installation in indoor electrical rooms adjacent to UPS batteries and IT racks, reducing bus duct length and energy loss. In large data centers, two or more 1000kVA units are paralleled on a common 400V bus to support N plus 1 or 2N redundancy.
Advantages and Features
Low partial discharge ensures long insulation life under continuous high voltage stress. Redundant N plus 1 cooling fans prevent shutdown if one fan fails. The Dyn11 winding neutral stabilizes voltage on single phase nonlinear loads. KITOZER offers an optional harmonic neutral balancing winding and a shielded core to reduce electromagnetic interference. The front accessible terminal chamber simplifies maintenance. Factory witness testing is available for large data center customers. Each unit ships with complete test certificate, installation drawing, and O&M manual. The thermal controller supports BMS and DCMS integration via Modbus TCP, giving facility managers real time winding temperature and fan status visibility.
Installation and Maintenance
Install on a reinforced concrete plinth with anti vibration pads. Maintain 1000mm front clearance for LV breaker withdrawal and 800mm rear clearance. Ensure dedicated ventilation supply with filtered air below 35 degrees Celsius. Connect neutral and ground to the data center grounding grid. Test insulation resistance annually with 2500V megger. Calibrate PT100 sensors every two years. Replace air filters every six months in dusty environments. KITOZER recommends quarterly visual inspection and annual thermal imaging during peak IT load. The redundant fan should be switched manually every quarter to exercise both cooling paths.
Construction and Quality Assurance
KITOZER data center transformers are built to a stricter acceptance level than standard industrial units. Partial discharge is held below 5pC at rated voltage, and sound is measured in an anechoic chamber to confirm the published dB figure. The redundant fan system includes two independent power supplies so a single fan or control card fault does not trigger a derating event. The copper windings are vacuum cast under computer controlled vacuum and temperature profiles to ensure void free insulation. KITOZER offers factory witness testing for Tier 3 and Tier 4 data center customers, including a full load bank run, an induced voltage withstand, and a 48 hour heat run at rated current. Each unit is supplied with a FAT report, a core diagram, and a SCADA point list.
Price
From $11,800/pc. Contact +86 13922289957 for data center transformer quotation.