The KITOZER Hot Aisle Containment Single Row 42U system seals the exhaust aisle behind a single row of server cabinets, capturing hot air at 35 to 45 degrees Celsius and returning it directly to CRAC/CRAH units through ducted overhead returns. This approach is preferred in legacy data halls with raised floors designed for cold supply rather than hot return, and in facilities where the room itself acts as the cold plenum. By containing the hot aisle, operators avoid heating the general data hall space, improve occupant comfort for technicians, and allow CRAC units to run at higher return temperatures, which improves chiller efficiency and enables free cooling for longer periods per year.
The hot aisle containment uses a robust aluminum roof frame, opaque or transparent roof panels depending on lighting requirements, insulated hot-return duct connections, and swinging or sliding end doors rated for high temperature. The system is delivered as a pre-engineered kit with all brackets, gaskets, and duct transitions factory-prepared for fast on-site assembly. KITOZER also provides duct sizing calculations so the overhead return path can handle the design airflow without excessive velocity or noise. The insulated roof panels are filled with 25mm rock wool to prevent condensation on the cold exterior surface, and the silicone gaskets are rated to 120 degrees Celsius for continuous high-temperature duty. Delivery is packed in export plywood cases, with insulated panels crated, duct flanges wrapped, and gaskets bagged separately.
Technical Specifications
Cabinet size: 600mm x 1200mm x 2000mm (42U). Aisle width: 1200mm standard, adjustable 1000 to 1500mm. Roof: 5mm polycarbonate or 1mm galvanized steel insulated panel, 25mm rock wool option. End doors: tempered glass or steel hinged doors, magnetic gaskets, operating temp up to 60 degrees Celsius. Hot return duct connection: 600mm x 600mm transition flange, flexible canvas connector. Pressure relief: optional roof relief damper 0.2 square meter, 5 to 20 Pa. Frame: anodized aluminum RAL 9006. Gaskets: silicone rated to 120 degrees Celsius. Operating ambient: 10 to 50 degrees Celsius. Air leakage: less than 5 percent at 20 Pa. CE, RoHS. KITOZER brand, 5 year structural warranty.
Applications
The single-row 42U hot aisle containment is suited to legacy data centers, retrofit projects, and rooms with overhead ducting. Typical users include banking mainframe rooms, insurance legacy application halls, government data service centers, university computer labs, hospital IT suites, and industrial SCADA control rooms. It is also used in retail data closets, telecommunications central offices, and media playout rooms where the raised floor is reserved for cold supply and hot exhaust must be returned through ceiling ducts. The insulated roof prevents heat radiation into the cold room, and the silicone gaskets withstand continuous high-temperature operation without aging.
Key Advantages
The main advantage is compatibility with existing raised-floor cold supply designs: no underfloor modification is needed. Second, hot exhaust at 35 to 45 degrees Celsius improves chiller efficiency and prolongs free cooling hours, reducing annual energy cost. Third, the general room stays cool at 22 to 27 degrees Celsius, improving working conditions for maintenance staff. Fourth, the insulated roof and duct prevent condensation. Fifth, the silicone gaskets withstand continuous high-temperature operation. Sixth, the system can be combined with rear-door heat exchangers or in-row coolers for very high densities. Seventh, the ducted return also simplifies fire damper integration with the building HVAC system.
Customization Options
Optional items include 50mm rock wool insulated roof panels, hot-return ductwork in galvanized or stainless steel, fire-rated silicone gaskets, automatic sliding end doors with heat-resistant operator, BMS monitoring for damper position, and pressure relief dampers sized to the room. For generator and UPS battery rooms, explosion-proof versions of the damper are available.
Installation and Maintenance
Installation takes 1 to 2 days for a 6-bay single row. The crew attaches roof brackets to cabinet tops, erects the aluminum frame, installs roof panels, connects the hot-return duct flange to the building ductwork, fits end doors, and applies silicone gaskets. The flexible canvas connector isolates vibration between cabinet containment and building duct. After go-live, verify hot aisle temperature does not exceed 45 degrees Celsius under full load, and check damper operation. Maintenance: inspect gaskets annually for heat aging, test door seals, and clean roof panels. KITOZER provides heat-resistant spare gasket rolls and duct connectors.