Table of Contents
ToggleProduct Overview
The KITOZER Hot Aisle Containment Double Row 42U seals the exhaust corridor between two opposing rows of server cabinets, creating a dedicated hot return plenum that connects to overhead CRAC/CRAH ductwork. This design is widely adopted in new and retrofit data halls where the raised floor or open room is used as the cold supply path. By isolating hot exhaust at high temperature, chillers operate at elevated return temperatures, free cooling is maximized, and PUE can be pushed below 1.4 in suitable climates. The double-row layout typically accommodates 12 to 24 cabinets and is the standard containment choice for enterprise data centers, colocation halls, and cloud on-premise rooms.
KITOZER supplies the double-row hot aisle containment with insulated steel roof panels, heavy-duty aluminum frame, swinging or sliding end doors, multi-point hot-return duct flanges, and a pressure relief assembly. Optional accessories include hot aisle LED lights, camera mounts, and BMS dry-contact monitoring. The insulated roof panels are filled with 25mm rock wool to prevent condensation on the cold exterior surface. The system works equally well with air-cooled chiller plants, water-cooled CRAH units connected to dry coolers, and rooftop packaged DOAS units. Delivery is packed in export plywood cases, with insulated panels crated, duct flanges wrapped, and gaskets bagged separately.
Technical Specifications
Cabinet size: 600mm x 1200mm x 2000mm (42U). Aisle width: 1200mm standard, adjustable 1000 to 1500mm. Row length: 6 to 12 cabinets per row. Roof: 1mm galvanized steel with 25mm rock wool insulation, optional clear polycarbonate. End doors: insulated steel hinged doors or tempered glass sliding doors, silicone gaskets, rated to 60 degrees Celsius. Duct connection: multiple 600mm x 600mm flanges with flexible canvas connectors. Pressure relief: top damper 0.3 square meter, 5 to 20 Pa. Gaskets: silicone 120 degrees Celsius. Operating temp: 10 to 50 degrees Celsius. Air leakage: less than 5 percent at 20 Pa. Fire: roof panels Class B1. CE, RoHS, ISO 9001. KITOZER brand, 5 year structure warranty.
Applications
The double-row 42U hot aisle containment is deployed in enterprise data centers, colocation halls, cloud on-premise rooms, banking and insurance data centers, government cloud service rooms, university HPC clusters, media render farms, and large VDI deployments. It is also preferred in climates with long free-cooling seasons because the high hot-return temperature allows air-side economizers to operate without mechanical cooling for most of the year. The system works equally well with air-cooled chiller plants, water-cooled CRAH units connected to dry coolers, and rooftop packaged DOAS units.
Key Advantages
The principal benefit is high-temperature hot return: CRAC units receive 35 to 45 degrees Celsius air, so chillers run at improved efficiency and free cooling hours are extended. PUE savings of 20 to 35 percent are typical. Second, the insulated roof prevents condensation and heat radiation into the cold room. Third, silicone gaskets withstand continuous 60-degree operation. Fourth, multiple duct flanges balance airflow across long aisles. Fifth, the open cold side keeps the data hall comfortable for staff. Sixth, the system is compatible with in-row coolers, rear-door heat exchangers, and direct expansion rooftop units. Seventh, the modular insulated panels can be removed and reused during future layout changes.
Customization Options
Optional extras include 50mm rock wool insulated roof panels for extreme climates, stainless steel duct flanges for coastal corrosive environments, automatic sliding heat-resistant end doors, BMS monitoring for damper and door state, fire-rated silicone gaskets, and roof-mounted camera brackets. For generator rooms, explosion-proof pressure relief dampers are available.
Installation and Maintenance
Installation takes 3 to 5 days for a 16-cabinet double-row layout. After cabinets are anchored, crews erect the aluminum frame, fit insulated roof panels, connect duct flanges to building ductwork with flexible canvas, install end doors, apply silicone gaskets, and balance the pressure relief damper. Commissioning should include hot aisle temperature measurement at multiple points and static pressure check. Maintenance: inspect gaskets annually for heat aging, test door seals every 6 months, and clean roof panels. KITOZER supplies replacement insulated panels, gasket rolls, and duct connectors from regional stock.
Warranty and Global Support
KITOZER backs every hot aisle containment with a 5-year structural warranty covering aluminum frames, insulated roof panels, and silicone gaskets, and a 1-year warranty on door operators and damper mechanisms. Heat-resistant spare gaskets, duct connectors, and damper springs are held in regional stock for next-day dispatch. KITOZER provides remote commissioning support, a detailed installation manual, and a dedicated project engineer for on-site work. Long-term maintenance contracts covering annual heat-aging inspection of gaskets, door seal testing, and damper calibration are available for multi-site data center operators and enterprise facilities teams.
Price
From $9,800 per 12-bay double-row 42U hot aisle containment kit (insulated roof, four end doors, duct flanges, gaskets, dampers). Contact +86 13922289957 for project pricing.