The KITOZER 40ft container data center rated at 200kW IT load is a high-density prefabricated compute module designed for rapid scaling of cloud, colocation, and enterprise data center capacity. It combines liquid-cooled and air-cooled zones within a single 40ft enclosure, supporting up to 30 racks with mixed density from 4kW to 20kW per rack. The unit is factory-built, pre-cabled, and pre-tested, then delivered to site as a complete module that only requires utility, network, and concrete pad connections. Multiple containers can be placed side by side to form a modular data hall of 500kW, 1MW, or more, sharing external plant and monitoring infrastructure.
Technical Specifications
The container supports 200kW continuous IT load, with 150kW handled by rear-door liquid cooling and 50kW by precision air conditioning. The external chiller plant provides 250kW cooling capacity with N+1 redundancy, using air-cooled screw compressors and free-cooling coils for mild weather. Power chain includes a 630A three-phase main switchboard, 250kVA online UPS with 20 minutes battery backup, and modular busway distribution with tap-off boxes for each rack. The KITOZER master controller aggregates 128 monitoring points and provides a 21-inch touchscreen HMI, with remote access via web browser and mobile app. Fire suppression uses gas clean agent with very early smoke detection. Enclosure is IP55, operating range minus 25 to 50 degrees Celsius.
Application Scenarios
This 200kW module is typically used by colocation providers expanding capacity in secondary markets, by cloud service operators deploying edge zones near major cities, and by large enterprises building hybrid cloud footprints. It is also ideal for temporary data centers during major construction projects, sporting events, and disaster recovery operations. Telecommunications companies use these modules as mobile edge compute sites for 5G network densification, while media and entertainment companies deploy them for on-location video editing and rendering. The unit can be clustered to form a 1MW campus with shared switchgear, chiller plant, and battery storage, reducing total cost compared with building traditional halls.
Advantages and Features
The mixed-cooling architecture allows customers to deploy standard air-cooled servers and high-density GPU racks in the same container, simplifying architecture and reducing spare parts inventory. The modular busway means rack additions or changes take minutes rather than hours, without rewiring power circuits. KITOZER controllers across multiple containers can be federated into a single site management system, providing a unified view of power, cooling, and security. The container design supports LEED-type sustainability goals through high cooling efficiency and the option to recover waste heat for site heating. All components are sourced from established industrial brands and backed by a global service network.
Installation and Maintenance Recommendations
Site preparation includes a reinforced concrete plinth, a 630A three-phase utility feed, fiber network termination, and a dedicated area for the external chiller with drainage. Containers should be anchored to the plinth and bonded to the site grounding grid. During commissioning, verify that busway tap-off units are correctly phased and that leak detection cables are continuous. Routine maintenance includes monthly filter changes, quarterly UPS battery testing, semi-annual chiller performance tuning, and annual fire suppression inspection. The KITOZER remote support team can access the controller through a secure VPN link, providing 24/7 monitoring and rapid fault diagnosis. For multi-container sites, schedule rotating maintenance windows so that at least one full N+1 set remains available at all times.
Reliability and Quality Assurance
The 200kW high-density module is factory-tested for 72 hours under combined electrical and thermal load, with all busway tap-off units, chiller plant components, and liquid couplings pressure-tested before shipment. The container shell is load-tested for wind and seismic conditions, and the IP55 seal is verified by pressure decay. Critical components including the 250kVA UPS, chiller, and fire suppression system carry internationally recognized certifications. KITOZER provides complete as-built documentation including P&ID drawings, electrical schematics, test reports, and spare part lists. The design service life is 20 years, with N+1 redundancy on all critical systems. A five-year warranty covers manufacturing defects, and extended service contracts include on-site spare parts storage and guaranteed response times. The remote support team monitors the federated DCIM 24/7, enabling proactive maintenance across multi-container campuses.
Sustainability and Environmental Responsibility
The mixed liquid and air cooling architecture with free cooling achieves a target PUE below 1.20, dramatically reducing energy use compared with traditional data halls. The container is built from recyclable steel, and all electronic components meet RoHS compliance. Waste heat can be recovered for site heating, and optional solar PV and battery storage enable renewable-powered operation. The modular relocatable design means capacity can be added or moved without demolition, reducing construction waste. These features support corporate carbon reduction targets and lower exposure to volatile utility prices over the 20-year service life.
Price
From $196,000 per unit, including chiller plant, CDU, 250kVA UPS, busway, and factory FAT. Contact KITOZER for multi-container pricing and site design support.