KITOZER
KITOZER

KITOZER Modular Data Center 500kW Mega Module

Product Overview

The KITOZER 500kW modular data center is a mega-scale prefabricated IT hall designed for rapid deployment of half-megawatt compute capacity. Built as a series of factory-finished sections, the module ships to site, is bolted together, and connected to utilities in a matter of weeks. It supports high-density racks, redundant power and cooling, and federated monitoring that can scale to multiple megawatts when several modules are clustered. The design is intended for hyperscale edge sites, large enterprise private clouds, and government data centers that need fast, predictable, and relocatable capacity.

Technical Specifications

Rated IT load is 500kW continuous, supporting up to 60 racks at 8 to 10kW average density, with liquid cooling options for up to 20kW per rack. Cooling uses a central chiller plant with free cooling and in-row CDU units, delivering target PUE below 1.20 in temperate climates. Power distribution includes a 1250A three-phase main switchboard, 600kVA modular UPS with 20 minutes battery autonomy, and overhead busway with per-rack metering. The KITOZER master controller provides a 24-inch HMI, 300 monitoring points, and federated DCIM across modules. Fire suppression uses gas clean agent with aspirating detection. Physical security includes biometric mantrap, 24/7 CCTV, and access logging. Enclosure is IP55 for covered outdoor installation.

Application Scenarios

This 500kW mega module is used by cloud service providers building edge zones near major cities, by large enterprises consolidating regional data centers, and by research institutions deploying supercomputing capacity. It is also suitable for temporary megawatt-scale capacity during permanent data center construction, and for permanent outdoor data halls in climates where building traditional structures is costly. Utility companies deploy clusters behind solar farms to form renewable-powered compute hubs, while media and entertainment companies use them for rendering and post-production workloads. Government agencies use them as secure, relocatable compute shelters for disaster response and national security applications.

Advantages and Features

The prefabricated construction cuts deployment time by 60 to 70 percent compared with traditional build, and reduces construction waste by more than half. The high cooling efficiency lowers both operating cost and carbon footprint, and the free cooling option uses outside air for much of the year. Modular UPS and busway allow capacity to be added incrementally, matching IT growth and avoiding stranded investment. KITOZER federated DCIM provides a unified view across the entire campus, with automated energy reports and capacity planning tools. The modules are designed for disassembly and relocation, protecting capital investment if business needs change. Standardized production also means consistent quality and predictable spare parts availability.

Installation and Maintenance Recommendations

Site preparation requires a reinforced concrete slab, a medium-voltage utility connection with on-site transformer, and a fiber ring network. Sections are delivered by truck and assembled by a KITOZER crew, typically within four to six weeks. During commissioning, test the medium-voltage switchgear, synchronize the UPS systems, and pressure-test the liquid cooling loops. Routine maintenance follows a structured program: weekly filter inspection, monthly electrical torque checks, quarterly battery testing, semi-annual chiller overhaul, and annual fire suppression certification. KITOZER provides long-term service contracts with guaranteed response times and on-site spare parts stocking, ensuring high availability for mission-critical workloads.

Reliability and Sustainability

The 500kW mega module undergoes 96 hours of factory testing under full megawatt-scale load, with medium-voltage switchgear, UPS systems, and liquid cooling loops all verified before shipment. KITOZER provides comprehensive as-built documentation including drawings, test reports, and spare part lists. The design service life is 20 years, with N+1 redundancy on all critical systems. A five-year warranty covers manufacturing defects, and extended service contracts include on-site spare parts storage and guaranteed response times. The liquid cooling and free cooling design achieves a target PUE below 1.20, dramatically reducing energy use. The modules are built from recyclable steel, and all electronics meet RoHS standards. Waste heat can be recovered for site heating, and optional solar PV and battery storage enable renewable-powered operation across multi-module campuses.

Energy Efficiency

The KITOZER federated DCIM provides real-time PUE, per-rack power usage, and trend reports for sustainability audits. Liquid cooling and free cooling dramatically reduce chiller energy, and the shared central plant avoids duplicated cooling systems. Modular UPS maintains high efficiency at partial load, and integrated battery storage enables peak shaving and demand response. Waste heat can be recovered for adjacent building heating. These measures typically reduce annual energy cost by 30 to 40 percent compared with traditional data halls over the 20-year service life.

Contact KITOZER for a campus-level energy model and return-on-investment analysis. The team also provides phased expansion planning to match capital expenditure with business growth.

Price

From $385,000 per module, including chiller plant, 600kVA modular UPS, busway, and factory FAT. Contact KITOZER for campus master planning and multi-module pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart