– Document Title: Rat-Specific Sperm Quality Analyzer Technical Design Solution
– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Date: August 2026
– Version: V1.0
– Project Type: Technical design solution for Rat-Specific Sperm Quality Analyzer
2. Table of Contents Structure
1. Company Introduction
2. Project Overview
3. User Requirement Analysis
4. Overall Design Description
5. Detailed System Design and Product Technical Parameters
6. Project Quotation and Configuration List
7. Core Solution Advantages
8. Technical Q&A
9. Construction Schedule Plan
10. Construction Organization Plan
11. After-Sales Service System
12. Operation and Maintenance Training Plan
13. Typical Project Cases
14. SEO Optimization System and Website Backend Configuration
15. Contact Information
3. Company Introduction
3.1 Company Development Overview
Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.
After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.
3.2 Core Business System
The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:
– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;
– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;
– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;
– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.
3.3 Brand and Qualification Honors
The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.
3.4 Core Competitive Advantages
1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;
2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;
3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;
4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.
4. Project Background and Objectives
4.1 Project Background
In reproductive biology research, drug reproductive toxicity evaluation, animal genetics and breeding, food safety toxicology and family planning research, rats are among the most widely used experimental animals. Sperm quality testing is the core experimental step for evaluating male reproductive function, verifying drug toxicity and screening breeding individuals.
Traditional manual microscopic examination has limitations: strong subjectivity with poor inter-operator repeatability; low efficiency unsuitable for large batches; inability to precisely quantify motion parameters (only rough motility grading, lacking VCL/VSL/LIN etc.); and high experience and training requirements. Computer-assisted sperm analysis (CASA) has become standard laboratory equipment, but most commercial analyzers are designed for human or large-animal semen, adapting poorly to rat sperm morphology and motion — low recognition accuracy and large errors.
This project designs a dedicated rat sperm quality analyzer solution, with targeted design across hardware adaptation, algorithm optimization, temperature control and data management.
4.2 Construction Objectives
– Precise rat sample adaptation: optimized hardware and algorithms for rat sperm morphology, size and motion — high recognition accuracy and experimental data compliance;
– Core motion parameters: concentration, motility grading (PR/NP/IM), VCL, VSL, VAP, LIN, STR, WOB;
– Stable results: dual-level temperature control maintaining sperm viability, avoiding temperature fluctuation effects, improving repeatability;
– High efficiency: automated image capture and analysis, single-sample detection within 2 minutes;
– Standardized data management: auto storage, retrieval, export, standardized reports, GLP compliance;
– Low usage threshold: visualized interface, short training for independent operation.
4.3 Significance
Improved data quality (less human error, higher repeatability); higher laboratory efficiency (automation frees personnel, parallel batch processing); standardized experiments (unified standards and data formats for cross-batch/lab comparison); lower long-term cost (reusable consumables, stable performance).
4.4 Applicable Scenarios
University life science/medical/pharmacy research labs; pharmaceutical safety evaluation centers (GLP); CDC toxicology labs; agricultural university and animal breeding research labs; reproductive health research institutes; third-party toxicology testing departments.
5. User Requirement Analysis
5.1 Core Functional Requirements
– Dedicated rat semen detection without complex adaptation;
– Core parameters: concentration, total motility, progressive/non-progressive/immotile rates, VCL/VSL/VAP/LIN/STR/WOB;
– Visualized detection process with single-sperm track viewing for manual review;
– Standardized report generation and printing; Excel/PDF export.
5.2 Performance Requirements
– Concentration range ≥1×10⁶~200×10⁶/mL;
– Repeatability: concentration CV≤5%, motility CV≤3%;
– Recognition accuracy ≥95% (excluding impurities, debris, RBCs);
– Temperature control 37℃±0.3℃ at detection area;
– Continuous operation ≥8h without drift.
5.3 Environment Adaptation
– Room temperature 10-35℃, RH≤80%; standard lab bench footprint; 220V/50Hz power.
5.4 Data Management
– Auto-saving with retrieval by sample number, date, group; batch export compatible with statistical software; user permissions; backup and recovery.
5.5 Service and After-Sales
– On-site installation, calibration and performance verification; on-site operation training; warranty with free repair of non-artificial damage; timely technical support.
5.6 Compliance
– Design/production per national and industry standards; GLP traceability; consumables biocompatible (non-cytotoxic, enzyme-free, pyrogen-free).
6. Design Principles and Applicable Standards
6.1 Design Basis
– GB 14925-2010 Laboratory Animal Environment and Facilities
– GB/T 13742-2009 Optical Microscopes Terminology
– WHO Laboratory Manual for the Examination and Processing of Human Semen (5th ed., parameter calculation adapted to rat characteristics)
– GB/T 29857-2013 Quality Assurance of Laboratory Instruments
– GB 4943.1-2022 IT Equipment Safety
– GLP data management and traceability norms; optical/electronic/software product quality standards
6.2 Design Principles
Scientific (industry-standard parameter definitions); accurate (optical, algorithm and temperature control dimensions); stable (quality components, consistent data); easy to use; expandable (morphology, acrosome, DNA fragmentation upgrades); safe (electrical and biological safety); economical (balanced initial and long-term cost).
7. System Architecture and Working Principle
7.1 System Architecture
Seven subsystems: optical imaging (phase-contrast microscope); image acquisition (high-speed global-shutter camera); temperature control (heated stage + pre-incubation module); sample handling (counting chambers, pipettes, slides); intelligent analysis (rat-specific software); data output (computer, display, printer); auxiliary support (damping table, calibration tools, cleaning kit, dust cover).
7.2 Working Principle and Detection Process
CASA technology: high-speed microscopic imaging and motion tracking compute motion parameters, concentration and motility. Process: sample pretreatment (dilution + 37℃ incubation) → loading (pipette into preheated counting chamber, no bubbles) → stage detection (heated stage, focus) → image capture (high-frame-rate multi-frame) → intelligent analysis (sperm recognition, track tracing, parameter calculation, motility grading) → result output (report with parameters, tracks, histogram; export/print) → cleaning.
8. Detailed Technical Design
8.1 Rat-Specific Adaptation Design
– Chamber depth 20μm: matches rat sperm head thickness and motion space, avoiding stacking and enabling planar motion;
– Optical optimization: phase contrast optimized for small, translucent rat sperm heads — clearer outlines;
– Algorithm optimization: recognition model trained on rat sperm samples (sickle-shaped head, long tail), distinguishing sperm from impurities and debris;
– Motion tracking optimization: multi-target tracking for fast rat sperm motion with frequent trajectory fluctuation — fewer target losses/mismatches;
– Dedicated diluent: osmotic pressure and pH matching rat seminal plasma, extending in-vitro survival and maintaining normal motion.
9. Recommended Configuration and Preliminary Budget
9.1 Configuration List
I. Core Analysis Host System
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 1 | Phase-contrast microscope system | Infinity-corrected optics, 10× wide eyepiece, 10×/20×/40× plan phase objectives, LED cold light, coaxial coarse/fine focus | set | 1 |
| 2 | High-speed global-shutter camera | 5MP CMOS, global shutter, 30fps full-res, USB3.0, low noise | unit | 1 |
| 3 | Integrated control host | One-piece body, built-in light control, anti-vibration base | unit | 1 |
| 4 | Trinocular observation tube | 50:50 split, 360° rotate, IPD 52-75mm | pc | 1 |
II. Temperature Control System
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 5 | Heated stage | Room temp~45℃, ±0.3℃, LED display | set | 1 |
| 6 | Pre-incubation module | 6-well tube module for 1.5mL tubes, ±0.5℃ | unit | 1 |
| 7 | Temperature calibration probe | PT100, ±0.1℃, with calibration software | pc | 1 |
III. Sample Preparation and Loading System
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 8 | Reusable sperm counting chamber | Optical glass, 20μm depth, dual chambers, autoclavable | pc | 2 |
| 9 | Single-channel adjustable pipettes | 0.5-10μL + 10-100μL, ISO 8655 | pc | 2 |
| 10 | Pipette calibration kit | Weights, tools, guide | set | 1 |
| 11 | Optical slides/cover slips | 76×26mm / 22×22mm, enzyme-free, clean grade | box | 1+1 |
IV. Rat-Specific Analysis Software
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 12 | Rat sperm analysis software (basic motion) | Rat-specific algorithm, concentration/motility/motion parameters, data management, reports | set | 1 |
| 13 | USB hardware dongle | Authorization lock | pc | 1 |
| 14 | Software installation and tutorial USB | Drivers, installer, videos, manual | set | 1 |
V. Data Processing and Output Equipment
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 15 | Desktop computer | Intel i5+, 16GB, 512GB SSD, Win11 Pro | unit | 1 |
| 16 | HD monitor | 23.8-inch, 1920×1080, IPS, low blue light | unit | 1 |
| 17 | B&W laser printer | A4, 1200dpi, ≥20ppm | unit | 1 |
| 18 | Wired keyboard/mouse | Ergonomic quiet | set | 1 |
VI. Calibration Tools and Auxiliaries
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 19 | Concentration calibration slide | Value-assigned microsphere slide, traceable, 10μm | pc | 1 |
| 20 | Dust cover | Waterproof Oxford cloth | pc | 1 |
| 21 | Optical cleaning kit | Lens paper, cleaner, swabs | set | 1 |
| 22 | Connection cables | USB3.0, power, signal | set | 1 |
| 23 | Anti-vibration workbench | All-steel, 1200×600×750mm, damping feet | pc | 1 |
VII. Initial Consumables Package
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 24 | Disposable counting chambers | 20μm, dual chambers, sterile, 50/box | box | 1 |
| 25 | Rat semen diluent | HEPES buffer, pH 7.2-7.4, matched osmotic pressure | set | 1 |
| 26 | Filter pipette tips | RNase/DNase-free | box | 2 |
| 27 | Powder-free latex gloves | Examination grade | box | 1 |
| 28 | 1.5mL sterile centrifuge tubes | RNase/DNase-free | pack | 1 |
9.2 Quotation Notes
The list is the complete standard configuration of the rat-specific sperm quality analyzer system, including hardware, software, computer/printer, calibration tools, workbench and initial consumables, with installation, calibration, training, warranty and transport. Optional upgrades (morphology analysis, acrosome detection, DNA fragmentation, motorized stage, multi-view auto capture) quoted separately. All reference prices in this solution are in RMB (CNY) only and are for reference purposes; a formal quotation is issued after configuration confirmation.
10. Technical Specifications
10.1 System Performance Summary
| Item | Specification |
|---|---|
| Detection object | Rat semen (dedicated adaptation) |
| Concentration range | 1×10⁶ ~ 200×10⁶/mL |
| Repeatability | Concentration CV≤5%; motility CV≤3% |
| Recognition accuracy | ≥95% |
| Temperature control | 37℃±0.3℃ (stage); pre-incubation ±0.5℃ |
| Parameters | Concentration, PR/NP/IM, total motility, VCL/VSL/VAP/LIN/STR/WOB, statistics |
| Detection time | ≤2 min/sample |
| Continuous operation | ≥8h without drift |
| Environment | 10-35℃, RH≤80%, 220V/50Hz |
| Optics | Infinity-corrected, 10×/20×/40× phase objectives |
| Camera | 5MP CMOS global shutter, 30fps, USB3.0 |
| Standards | GB 14925, GB/T 13742, WHO 5th ed. (rat-adapted), GB 4943.1 |
10.2 Software Features
| Module | Functions |
|---|---|
| Real-time preview | Live view, zoom/pan, exposure/gain/frame config, capture/record, multi-view auto capture |
| One-click analysis | Auto recognition, tracking, calculation, save; manual correction |
| Data management | Auto-save, multi-condition query, Excel/PDF export, backup/recovery |
| Reports | Standard templates, custom templates, print/PDF |
| Calibration | Concentration (microsphere slide), scale (stage micrometer), temperature (probe) — logged |
| Permissions | Admin/operator/visitor; operation logs |
| QC | Quality control sample testing, control charts, alarm/warning limits |
11. Key Advantages and Customer Value
11.1 Dedicated Rat Design for Precise Detection
Hardware and algorithms optimized for rat sperm (sickle-shaped head, long tail, fast motion): 20μm chamber depth, optimized phase contrast, rat-trained recognition model and motion tracking — high accuracy versus generic analyzers.
11.2 Dual-Level Temperature Control for Stable Results
Heated stage (37℃±0.3℃) and pre-incubation module maintain sperm viability, eliminating temperature fluctuation effects for repeatable, reliable data.
11.3 Automated Analysis for High Efficiency
Automated capture and analysis complete a sample within 2 minutes with one-click operation, manual correction support and multi-view auto capture — greatly improving batch processing throughput.
11.4 Standardized Data for Laboratory Compliance
Unified parameter definitions (WHO-based, rat-adapted), standardized reports, data traceability, permission management and QC functions — meeting GLP and standardized experiment requirements.
11.5 Reusable Consumables for Lower Long-Term Cost
Reusable autoclavable counting chambers and calibrated pipettes reduce ongoing consumable expenditure; stable hardware extends service life.
11.6 Modular Design for Expansion
Reserved upgrade paths: morphology analysis, acrosome detection, DNA fragmentation, motorized stage and multi-view capture — protecting investment.
11.7 Source Factory Service
Self-developed production with full-process support: installation, calibration, training, warranty, rapid after-sales response and software upgrades.
11.8 Easy to Operate
Visualized interface and streamlined workflow enable independent operation after short training — low usage threshold for lab personnel.
12. Technical Q&A (50+ Items)
12.1 Equipment Basics
Q1: What is a rat-specific sperm quality analyzer?
A: A CASA-based analyzer specifically optimized for rat semen: phase-contrast microscopy, high-speed camera and rat-specific algorithms automatically detect concentration, motility and motion parameters of rat sperm.
Q2: Why is a rat-specific analyzer needed instead of a human one?
A: Rat sperm differ significantly from human sperm in morphology (sickle head, long tail), size and motion speed; generic analyzers have poor recognition accuracy and large errors on rat samples. Dedicated hardware/algorithm optimization is required for accurate results.
Q3: What is CASA?
A: Computer-Assisted Sperm Analysis — automated microscopic imaging and motion tracking computing sperm parameters objectively, replacing subjective manual assessment.
Q4: What is the detection principle?
A: Sperm are imaged at high frame rates; software recognizes each sperm, tracks its trajectory frame by frame, and calculates concentration, motility grades and motion parameters (VCL/VSL/VAP/LIN/STR/WOB).
Q5: Is the equipment suitable for other species?
A: The base platform supports customization for other species (mouse, human, large animals) with matching chambers and algorithms — consult for configuration.
12.2 Detection Performance and Parameters
Q6: What parameters are output?
A: Concentration, progressive (PR), non-progressive (NP), immotile (IM), total motility, VCL, VSL, VAP, LIN, STR, WOB, plus averages/medians/SD and histograms.
Q7: What is the concentration range?
A: 1×10⁶~200×10⁶/mL standard, covering the rat semen concentration range; dilution guidance for higher concentrations.
Q8: How accurate is detection?
A: Recognition accuracy ≥95%; concentration repeatability CV≤5%; motility CV≤3% — meeting research-grade precision.
Q9: Why 37℃ temperature control?
A: Rat sperm motility is temperature-sensitive; 37℃ maintains physiological activity during detection, ensuring motion parameters reflect true status; ±0.3℃ stability ensures repeatability.
Q10: How long does a single sample take?
A: Within 2 minutes from loading to result — far faster than manual examination.
Q11: How is sperm distinguished from debris?
A: The rat-trained recognition model uses morphology (head shape, tail) and motion characteristics to exclude impurities, debris and RBCs; manual correction is available for review.
Q12: What are LIN/STR/WOB?
A: LIN = VSL/VCL (path straightness), STR = VSL/VAP (forward direction), WOB = VAP/VCL (sway amplitude) — describing sperm motion patterns per WHO definitions.
12.3 Sample Handling and Operation
Q13: How is the sample prepared?
A: Dilute rat semen with the dedicated diluent (matched pH/osmotic pressure), incubate at 37℃ in the pre-incubation module to restore normal motility, then load into the preheated counting chamber.
Q14: Why the 20μm chamber depth?
A: Matches rat sperm head thickness and motion space — prevents stacking for accurate counting while allowing free planar motion for tracking.
Q15: How is the sample loaded?
A: Pipette the diluted sample into the counting chamber ensuring the chamber fills without bubbles; place on the heated stage and focus.
Q16: Can the counting chamber be reused?
A: Yes — the glass chamber is autoclavable and reusable; disposable chambers are provided for emergency or field use.
Q17: What pipettes are included?
A: 0.5-10μL and 10-100μL adjustable pipettes per ISO 8655 for sampling and dilution; calibration kit for periodic verification.
Q18: How should samples be handled safely?
A: Wear powder-free gloves, use sterile tubes and filter tips, follow biological safety practices per laboratory rules; consumables are non-cytotoxic and enzyme/pyrogen-free.
Q19: Can frozen/thawed samples be analyzed?
A: Yes, with appropriate preparation; motility parameters of thawed samples reflect cryopreservation quality — standard analysis applies.
Q20: What if sperm concentration is very low?
A: The software reports low-concentration samples with appropriate statistics; concentration can be increased by adjusting dilution or using larger fields.
12.4 Software Functions and Data
Q21: How is the analysis started?
A: Load the sample, focus, click “Start Analysis” — the software auto-completes recognition, tracking, calculation and saving; results viewable immediately.
Q22: Can results be manually corrected?
A: Yes — add or delete recognition targets to fix false positives/negatives, ensuring accuracy.
Q23: What reports are generated?
A: Standard reports include sample info, parameter results, motility distribution histogram and motion track examples; templates customizable (logo, title, parameters).
Q24: How is data exported?
A: Excel for parameter data, PDF for full reports; batch export supports statistical software.
Q25: How is data secured?
A: Three-level permissions (admin/operator/visitor), operation logs, backup and recovery — GLP-compliant traceability.
Q26: Does the software support QC?
A: Yes — quality control sample testing with control charts and alarm/control limits monitoring device stability.
Q27: What system does the software require?
A: Windows 11 Pro, i5+, 16GB RAM, 512GB SSD — the included computer meets requirements.
Q28: Can data be shared across laboratories?
A: Standardized parameter definitions and export formats enable cross-lab data comparison; network versions customizable.
12.5 Maintenance, Calibration and Care
Q29: What daily maintenance is needed?
A: Clean the stage and objectives after use (optical cleaning kit), cover the instrument, check temperature display, clean counting chambers.
Q30: How often is calibration needed?
A: Annual calibration recommended (concentration via microsphere slide, scale via micrometer, temperature via probe); calibration records logged for traceability.
Q31: How is the camera maintained?
A: Keep the sensor clean (dust cover), avoid direct light, check USB connection; cleaning per the optical cleaning guide.
Q32: What if the temperature deviates?
A: Verify ambient temperature, check the heated stage and probe; recalibrate temperature via the calibration function; contact support if persistent.
Q33: How are objectives cleaned?
A: Use lens paper and cleaner from the optical kit — never dry-wipe; clean gently in a spiral motion.
Q34: What spares are recommended?
A: Spare counting chambers, pipette tips, diluent, gloves, tubes and fuses — stocked for fast supply.
Q35: Is the anti-vibration workbench necessary?
A: Recommended — microscope imaging is vibration-sensitive; the damping table minimizes interference for stable tracking.
12.6 Installation and After-Sales
Q36: What does installation include?
A: On-site installation, optical alignment, camera setup, software installation and activation, calibration and performance verification.
Q37: What training is provided?
A: Theory (~2h), hands-on operation (~4h) and maintenance/troubleshooting (~1h) with assessment; free repeat training for new staff.
Q38: What is the warranty?
A: Typically 1-year warranty with free repair of non-artificial damage; after warranty, lifetime cost-price service; software upgrades supported.
Q39: What is the response time?
A: 7×24 hotline, remote guidance within 1 hour; on-site per region; critical faults prioritized.
Q40: What documentation is delivered?
A: User manual, software guide, calibration records, installation report, certificates and after-sales card.
12.7 Selection and Procurement
Q41: What is the delivery time?
A: Standard configuration about 15-25 working days (production + installation); custom options extend accordingly.
Q42: Can the system be upgraded later?
A: Yes — morphology analysis, acrosome detection, DNA fragmentation and motorized stage upgrades available; software modular.
Q43: Is the system suitable for GLP labs?
A: Yes — standardized reports, permission management, operation logs, calibration records and QC functions meet GLP traceability requirements.
Q44: What power supply is needed?
A: Standard 220V/50Hz; no special configuration; total power consumption low.
Q45: What is the footprint?
A: Compact bench-top system on the included 1200×600×750mm workbench — fits standard laboratory space.
Q46: Can the printer be used for other purposes?
A: Yes — the standard A4 B&W laser printer serves general lab printing needs.
Q47: How is the software licensed?
A: Permanent license for the basic motion version with USB dongle; upgrades per module.
Q48: What consumables are included initially?
A: Disposable chambers (50), diluent, filter tips, gloves, tubes — sufficient for initial operation; replenishment available.
Q49: Is third-party verification available?
A: Concentration calibration slide traceable to standards; optional third-party verification per lab requirements.
Q50: How is the system packed for transport?
A: Professional packaging with shock protection; the workbench shipped separately; on-site installation included.
Q51: What is the expected service life?
A: 5+ years with standard maintenance; optics and camera have long life; consumables per usage.
Q52: How is the project accepted?
A: Acceptance covers: hardware installation, software functions, calibration verification, performance testing (repeatability, accuracy), training completion and documentation handover — jointly signed.
13. Construction Schedule
13.1 Overall Period
The total project period is approximately 15-25 working days from order confirmation to acceptance, dominated by production; on-site installation and training typically 2-3 days.
13.2 Stage Schedule
| Stage | Work | Days | Responsible |
|---|---|---|---|
| 1. Order and design confirmation | Configuration confirmation, contract, production plan | 2 | Both parties |
| 2. Production | Optics, camera, host, temperature modules, software preparation | 10-18 | Factory |
| 3. Factory testing | Optical alignment, camera calibration, software verification, performance test | 2 | QC |
| 4. Packaging and transport | Professional packaging, delivery | 1-2 | Logistics |
| 5. On-site installation | Installation, calibration, performance verification | 1 | Engineer |
| 6. Training and acceptance | Operation training, assessment, acceptance | 1-2 | Engineer + PM |
13.3 Key Node Control
– Configuration confirmation node; factory testing node (performance verification); on-site calibration node; training and acceptance node with documentation.
13.4 Schedule Assurance Measures
Advance production planning; experienced installation engineers; coordination with the lab for installation windows; spare parts available; daily progress communication.
14. Construction Organization and Quality/Safety Measures
14.1 Organization Structure
– Project manager: overall responsibility, client interface, progress control;
– Technical leader: installation, calibration, training, technical support;
– QC engineer: factory testing, calibration records;
– Logistics: packaging, transport, delivery.
14.2 Pre-Installation Preparation
1. Technical: site survey (bench, power, environment), confirm installation position; technical disclosure;
2. Materials: device incoming inspection (appearance, accessories), software and dongle verification;
3. Site: coordinate power and workspace; vibration-free location confirmed.
14.3 On-Site Installation Process
1. Workbench placement and leveling; instrument setup on damping base;
2. Microscope assembly, objective installation, optical alignment; camera installation and USB connection;
3. Heated stage and pre-incubation module installation and wiring; temperature verification;
4. Computer, monitor and printer setup; software installation and dongle activation;
5. Calibration: concentration (microsphere slide), scale (micrometer), temperature (probe);
6. Performance verification with standard samples; trial detection;
7. Training (theory + practice + maintenance) and assessment;
8. Acceptance with documentation handover.
14.4 Quality Control
– Factory testing records; on-site calibration records; performance verification (repeatability, accuracy); training assessment; acceptance documentation per checklist.
14.5 Safety and Civilized Work
– Electrical safety (certified connections); biological safety (sample handling per lab rules); clean work; protection of lab equipment; compliance with laboratory management rules.
14.6 Emergency Plans
– Equipment anomaly during installation: stop, diagnose, resolve with spare parts; injury: first aid and emergency services; sample-related incidents per lab biosafety procedures.
15. After-Sales Service
15.1 Warranty Commitment
Typically 1-year warranty with free repair/replacement of non-artificial quality problems; lifetime cost-price maintenance after warranty.
15.2 After-Warranty Service
Paid maintenance at material cost + basic labor; software upgrades supported; periodic calibration service available.
15.3 Fault Response and Handling
7×24 hotline; remote guidance within 1 hour; on-site per region (urban 4h); critical faults prioritized; troubleshooting records documented.
15.4 Spare Parts Supply
Counting chambers, pipettes, tips, diluent, fuses, camera accessories and consumables stocked; emergency logistics within 48h.
15.5 Periodic Inspection and Maintenance
Semi-annual inspection (optics, camera, temperature, calibration status); annual comprehensive service with calibration verification and reports.
15.6 Software Upgrade
Feature upgrades (morphology, acrosome, DNA fragmentation) and bug fixes; version updates per license policy.
15.7 Technical Consultation
Free lifetime consultation on detection methods, sample preparation, data analysis and experiment design.
16. Training Plan
16.1 Training Objectives
Enable lab personnel to independently operate the analyzer: sample preparation, detection, software use, data management, basic maintenance and troubleshooting.
16.2 Audience
Lab managers and operators (typically 2-4 persons per lab).
16.3 Content
– Theory (~2h): CASA principles, rat sperm characteristics, parameter definitions, sample preparation;
– Practice (~4h): instrument operation, sample loading, detection process, software use, report generation;
– Maintenance and troubleshooting (~1h): cleaning, calibration, common faults.
16.4 Methods and Schedule
On-site training at installation; combined theory + hands-on + Q&A; schedule per lab availability; free repeat training for new personnel.
16.5 Assessment
Theory + practice assessment; qualified operators receive training certificates; unqualified receive supplementary training.
16.6 Documentation Delivery
User manual, software guide, operation videos, calibration records and training materials — bound for reference.
15. After-Sales Service
15.1 Warranty Commitment
The overall project warranty period is 2 years from the date of completion acceptance; core equipment has a 3-year warranty. During the warranty period, all failures and damage caused by product quality or construction process problems are repaired and parts replaced free of charge. After the warranty period, lifetime cost-price maintenance is provided, charging only parts cost and basic labor, ensuring long-term stable system operation.
15.2 After-Sales Response Mechanism
– A 7×24 after-sales hotline receives fault reports and technical consultations at any time;
– Within the urban area: respond within 2 hours, technicians on site within 4 hours;
– Suburban and surrounding areas: respond within 4 hours, personnel on site within 8 hours;
– General faults resolved on the spot; complex faults solved within 24 hours with a solution;
– Emergency faults get a green channel with priority dispatch of personnel and parts.
15.3 Periodic Inspection and Maintenance
During the warranty period, a free on-site inspection is provided every six months, with a comprehensive maintenance inspection annually. Inspection contents include equipment operating status, connection firmness, sealing and rust conditions, filtering/grounding performance and safety devices. After each inspection, a formal inspection report is issued recording equipment status and maintenance content with optimization suggestions.
15.4 Spare Parts Supply Guarantee
A local spare parts warehouse is established, stocking common wearing parts for quick replacement to shorten fault handling time. For uncommon special parts, a fast supply channel with the factory ensures availability within 48 hours. During warranty, non-artificial-damage spare parts are replaced free; after warranty, parts are charged at cost price without markup.
15.5 System Upgrade and Technical Support
– Free lifetime technical consultation services by phone or online at any time;
– If the customer later needs upgrades or expansions, preferential upgrade solutions and construction services are provided;
– Industry new technology and standard information is regularly pushed to customers.
16. Training Plan
16.1 Training Objectives and Audience
Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.
Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.
16.2 Tiered Training Content System
Level 1: Basic operation training (1 day)
– Basic principles: system concepts, structure composition, performance indicators;
– Daily operation standards: correct operation of equipment, control and safety systems;
– Daily inspection contents: daily/weekly/monthly check items;
– Safety precautions: usage prohibitions and emergency handling procedures.
Level 2: Maintenance training (1 day)
– Detailed structure of each subsystem and working principles;
– Daily maintenance methods: cleaning, fastening checks, routine care;
– Common fault identification and simple handling;
– Emergency handling procedures for power failure, fire and equipment faults.
Level 3: Advanced management training (as needed)
– Performance influencing factors and how to avoid degradation;
– Upgrade and expansion knowledge and specification requirements;
– Relevant national standards interpretation.
16.3 Training Methods and Schedule
– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;
– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.
16.4 Training Assessment and Documentation Delivery
– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;
– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.
17. Anonymous Typical Project Scenarios
All project scenarios below are anonymous, generalized examples compiled from typical industry deployments; no real customer names, addresses or confidential information are disclosed.
17.1 Reproductive Toxicology Laboratory of a Medical University
A medical university’s reproductive toxicology lab needed standardized rat sperm analysis for drug toxicity studies. The rat-specific analyzer delivered accurate concentration and motion parameters with high repeatability (CV≤5%), replacing subjective manual examination; standardized reports and traceable data met experimental quality requirements, and automated analysis tripled daily sample throughput.
17.2 Safety Evaluation Center of a Biopharmaceutical Enterprise
A GLP safety evaluation center required compliant rat sperm analysis for regulatory submissions. The analyzer’s permission management, operation logs, calibration records and QC functions satisfied GLP traceability; rat-adapted algorithms ensured data reliability across large study batches, and the reusable counting chambers reduced long-term consumable costs.
17.3 Animal Genetics and Breeding Laboratory of an Agricultural University
An agricultural university’s animal genetics lab used the analyzer for breeding individual screening. Rapid automated analysis enabled large-scale screening, and motion parameter data supported breeding decisions; the modular design allowed future morphology analysis upgrades.
17.4 Toxicology Laboratory of a Provincial CDC
A provincial CDC’s toxicology lab deployed the analyzer for food safety and chemical toxicology testing. The stable temperature control and standardized workflow ensured reproducible results; training enabled independent operation by lab staff, and timely after-sales support maintained continuous availability during peak testing periods.
18. SEO Optimization Section
All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.
18.1 Keyword System
– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;
– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;
– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;
– Brand keywords: KITOZER, Guangzhou Lain.
18.2 SEO Tag System
– Title tag: the article title — Guangzhou Lain KITOZER;
– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;
– H1 tag: the article title;
– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.
18.3 Internal Link Anchor Text
– Core anchor text: technical design solution, system construction;
– Long-tail anchor text: configuration list, technical parameters, construction plan;
– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.
19. Official Contact Information
– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Official Website: https://gdlain.com
– Tel: +86 13509238849 (Tel / WhatsApp)
– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.