The KITOZER HFC-227ea (HFC-227ea, FM-200) fire suppression system is a 4.2 MPa clean agent total-flooding solution. HFC-227ea is a colorless, odorless, electrically non-conductive gas that suppresses fire by chemical inhibition of the combustion reaction. Discharge occurs within 10 seconds, and design concentrations of 7 to 9 percent by volume are effective on Class A, B, and C fires. Because HFC-227ea is stored as a liquid, cylinder quantities are much smaller than inert gas systems, making it ideal for projects with limited cylinder room space. It is the most widely adopted clean agent in data centers, switch rooms, and control rooms globally.
HFC-227ea is available in two storage pressure options: 2.5 MPa (25 bar) for shorter pipe runs and 4.2 MPa (42 bar) for longer networks where higher pressure compensates for pipe friction. KITOZER provides both variants and selects the appropriate pressure based on the hydraulic calculation. The 4.2 MPa model uses heavier Schedule 40 high-pressure piping and brass nozzles rated for 100 bar service.
Technical Specifications
Agent: HFC-227ea (heptafluoropropane), CAS 431-89-0. Storage pressure: 2.5 MPa (25 bar) at 20 degrees Celsius, or 4.2 MPa (42 bar) high-pressure model. Cylinder: 40L, 70L, 90L, 120L steel. Fill density: 1125 kg per cubic meter max (low pressure), 950 kg per cubic meter (high pressure). Design concentration: 7 to 9 percent. Discharge time: less than 10 seconds. Hold time: 10 minutes. Piping: Schedule 40 black steel, threaded. Nozzles: brass, adjustable. Actuator: 24V DC electric + manual. ODP: 0. GWP: 3220 (100-year). Atmospheric lifetime: 36 years. Certifications: NFPA 2001, ISO 14520, GB 25973. KITOZER brand, 5 year cylinder warranty.
Applications
HFC-227ea is the standard for data center server rooms, UPS rooms, electrical switchgear rooms, battery rooms, telephone exchanges, control rooms, process automation panels, museums, and archive vaults. It is especially suitable when cylinder room space is constrained, because a single 90L cylinder protects 100 cubic meters of room. KITOZER supplies both pipe-network systems (multi-room, selector valves) and cabinet-unit systems (pre-assembled 40L units for single rooms).
Key Advantages
First, fast 10-second discharge beats fire spread. Second, compact cylinders require less floor space. Third, effective on Class A, B, C fires. Fourth, non-conductive and residue-free. Fifth, proven track record over 30 years. Sixth, global approvals. Seventh, lower installed cost than inert gas for small rooms. Eighth, both 2.5 MPa and 4.2 MPa options match pipe length.
Installation and Maintenance
Cylinders are mounted on brackets, piped with Schedule 40 threaded steel, and nozzles installed per hydraulic calculation. A small pressure vent is required. Commissioning includes actuator test, detector walk test, and abort switch test. Maintenance: weigh cylinders every 6 months, refill if loss exceeds 1.5 percent, test detectors annually, hydrotest cylinders every 12 years. KITOZER supplies HFC-227ea refill, valves, and nozzles globally.
Price
From $6,800 per small room (one 90L cylinder, piping, nozzles, control panel). Contact +86 13922289957 for HFC-227ea project design.