KITOZER
KITOZER

KITOZER MNS Low Voltage Distribution Cabinet For Industrial MCC

Product Overview

The KITOZER MNS low voltage distribution cabinet is a type tested modular switchgear system for 400V industrial motor control centers, power distribution boards, and capacitor compensation panels. Based on the worldwide MNS standard, each cubicle uses a 25mm sheet steel modular frame, vertical wire ways, and withdrawable drawer units. KITOZER engineers the MNS system for high short circuit withstand and internal arc classification, making it suitable for continuous process industries where personnel safety and uptime are critical.

Technical Specifications

Rated voltage 400V, 50Hz, rated current up to 6300A main bus. Short time withstand 80kA for 1 second. Drawer units from 9E to 72E size, feeder MCCB up to 630A, motor starters up to 315kW. Automatic transfer switch panel, capacitor compensation panel, and feeder board available in the same frame. Protection degree IP4X front, IP2X rear. Internal arc classification AFLR 1 sec on request. Panel width 600, 800, 1000mm, depth 800 or 1000mm, height 2200mm. Standards IEC 61439-1 and -2, GB 7251, CE, type tested.

Application Scenarios

MNS cabinets are deployed in refineries, chemical plants, pulp and paper mills, mining facilities, and water treatment plants. They also serve as the main LV switchboard for large commercial complexes and as the MCC for conveyor, pump, and fan motor groups. The modular design supports step by step expansion as production lines grow.

The MNS system can also house an ATS panel, a capacitor compensation panel, and a feeder board in the same row, reducing overall switchroom footprint. The drawers are color coded by function, making maintenance faster and safer. The self ejecting contacts ensure that a drawer cannot be removed while the circuit is live. KITOZER offers a motor protection relay with Modbus for each motor feeder, allowing remote monitoring of current, vibration, and winding temperature. The internal arc classification protects operators during internal fault events.

Advantages and Features

Type tested system guarantees consistency across panels. Withdrawable drawers allow unit swap in under 5 minutes. Internal arc classification protects operators during fault events. KITOZER offers options including a motor protection relay with Modbus, an energy meter per feeder, and a SCADA gateway. The modular frame allows future retrofits without replacing the whole board.

Installation and Maintenance

Place panels on a flat plinth with 1500mm front clearance for drawer withdrawal. Connect horizontal and vertical busbars with torque specified in the manual. Bond all panels to the plant ground. Commissioning includes a pre energization insulation test, a drawer insertion and withdrawal cycle, and a protection relay test. Annual maintenance includes contactor contact inspection, heater function, and busbar torque check. KITOZER recommends a 10 year inspection of the main busbar and drawer contacts.

Construction and Quality Assurance

The MNS cabinet is a type tested system built on a 25mm sheet steel modular frame. The horizontal busbar is rated for 6300A with 80kA short time withstand. Each drawer unit has connected, test, and disconnected positions with self ejecting contacts. The internal arc classification AFLR 1 sec is available on request. Every panel passes a power frequency withstand, contact resistance, and insulation resistance test. KITOZER provides a type test certificate and FAT report. The modular frame allows future feeder additions by simply plugging in a new drawer.

Packaging and After Sales

Panels are shipped on a steel skid with drawers in disconnected position. KITOZER provides commissioning support. The 2 year warranty covers busbar, breakers, and drawers. Spare drawers, contactors, and relays are stocked. For continuous process plants, KITOZER offers a spare drawer for rapid swap.

KITOZER offers a range of optional extras including a motor protection relay with Modbus per feeder, an energy meter per circuit, and a SCADA gateway. The MNS can be configured as a main switchboard, a distribution board, or a motor control center. The 600mm wide drawer modules allow high circuit density in a small footprint. The self ejecting contacts ensure safe withdrawal. KITOZER provides a full type test certificate for the whole MNS system, ensuring compliance with IEC 61439.

The 2 year warranty covers busbar, breakers, and drawers. For continuous process plants, KITOZER offers a spare drawer for rapid swap and a 5 year extended warranty.

The MNS is also available with an arc fault detection system and a busbar temperature monitoring option. The panel can be supplied with a pre installed SCADA gateway. KITOZER provides a complete set of drawings, a FAT report, and an operation manual. The type tested system ensures that every panel built is identical to the type tested sample.

Price

From $2,480/panel. Contact +86 13922289957 for MNS MCC quote.