KITOZER
KITOZER

KITOZER 1MW Utility Scale PV Inverter Station

Product Overview

The KITOZER 1MW utility scale PV inverter station is a skid mounted power conversion solution for large ground mount solar plants. Two 500 kW central inverters are paralleled inside a 40 ft outdoor container, with a built in 1250 kVA step up transformer and MV switchgear bay. The station achieves 99 percent peak efficiency and delivers power directly at 10 kV or 35 kV medium voltage. A central control room screen shows real time yield, DC voltage, and grid parameters across the whole plant.

Technical Specifications

AC side: three phase 400 V LV, 50 or 60 Hz, 1 MW continuous, with built in 1250 kVA step up transformer to 10 kV or 35 kV MV. DC side: four MPPT, 500 to 1500 Vdc, 1600 A maximum. Maximum DC input 1.5 MW. Efficiency 99 percent peak. THDi less than 1.5 percent, power factor adjustable 0.8 to 0.8. Communication: dual Ethernet, Modbus TCP, IEC 61850, DNP3. Protection: DC switch, type 2 surge, arc fault, MV protection relay. Enclosure IP54, weight 12000 kg, dimensions 12192 by 2438 by 2896 mm 40 ft container. Standards CE, IEC 62109, KITOZER 5 year warranty.

Application Scenarios

The 1 MW station is the standard building block for utility scale solar plants from 10 MW to 1 GW. It is also used at solar plus storage plants, floating solar, and large agrivoltaic installations. The built in MV transformer and switchgear reduce on site engineering, which is critical for fast track utility projects.

Advantages and Features

Two parallel inverters deliver N plus one redundancy: if one 500 kW section faults, the other keeps the station running at half power. The 99 percent peak efficiency maximizes energy yield over the 25 year plant life. The built in MV transformer and switchgear reduce civil works. The station is precommissioned at the factory, so on site commissioning takes only days. The cloud portal shows per station yield and supports automated SCADA integration.

Installation and Maintenance

Place the station on a reinforced concrete pad with crane access. Terminate the MV cable at the built in switchgear, and connect the DC side to the array combiner boxes via a 2000 A DC bus duct. Commissioning requires a factory engineer and a full protection relay test. Monthly checks cover coolant level, MV insulation, and surge counter readings. Annual service includes heat exchanger cleaning, MV transformer oil test, and firmware update.

Price

From $78,000 per station including MV transformer. Contact plus 86 13922289957 for multi MW plant EPC pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top