KITOZER
KITOZER

Steel Fire Door

Table of Contents

1. Cover / Document Information

– Document Title: Steel Fire Door Technical Design Solution

– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Date: August 2026

– Version: V1.0

– Project Type: Technical design solution for Steel Fire Door

2. Table of Contents Structure

1. Company Introduction

2. Project Overview

3. User Requirement Analysis

4. Overall Design Description

5. Detailed System Design and Product Technical Parameters

6. Project Quotation and Configuration List

7. Core Solution Advantages

8. Technical Q&A

9. Construction Schedule Plan

10. Construction Organization Plan

11. After-Sales Service System

12. Operation and Maintenance Training Plan

13. Typical Project Cases

14. SEO Optimization System and Website Backend Configuration

15. Contact Information

3. Company Introduction

3.1 Company Development Overview

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.

After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.

3.2 Core Business System

The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:

– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;

– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;

– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;

– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.

3.3 Brand and Qualification Honors

The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.

3.4 Core Competitive Advantages

1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;

2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;

3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;

4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.

4. Project Background and Objectives

4.1 Industry Background and Policy Environment

With the rapid development of the construction industry in China, building fire safety has become a core part of public safety. As the most important movable component in a building fire separation system, the fire door is a critical line of defense that prevents fire spread and smoke diffusion and guarantees personnel evacuation. Fire doors are widely installed at fire compartments, evacuation stairwells, pipe shafts, equipment rooms and evacuation corridors.

The national standard *Code for Fire Protection Design of Buildings* (GB 50016) clearly requires that buildings with different fire-resistance ratings and areas with different hazard levels must be equipped with fire doors of the corresponding rating, and that the products must comply with the national standard *Fire Doors* (GB 12955) and pass the mandatory 3C fire-product certification. In recent years, fire authorities across the country have continuously strengthened acceptance inspection and routine inspection of building fire-protection installations, placing stricter requirements on the product quality, installation compliance and serviceability of fire doors.

Against this background, both new construction and fire-retrofit projects have a steadily growing demand for compliant, reliable and durable steel fire doors, together with higher requirements for customization capability and supporting services.

4.2 Project Overview

This project is part of a building fire separation system. For a large opening of 2970 mm (W) x 2970 mm (H), the solution supplies a Class A double-leaf, center-hung steel fire door, with the door leaves fully filled with fire-resistant rock wool, matched with a complete set of fire-rated hardware and a sealing system, meeting the Class A fire-resistance limit requirements.

The door is mainly used at long-span fire compartment partition walls, large equipment room entrances, warehouse fire separations and other locations that require wide passage and a high fire-resistance rating. It must satisfy both the daily passage of personnel and equipment and the effective blocking of flame and smoke spread in case of fire, buying critical time for evacuation and firefighting.

4.3 Core Project Objectives

Compliance objective: the product and its installation fully comply with current national fire-protection codes and standards, with complete certification and test documentation, ensuring one-pass fire acceptance.

Fire-safety objective: meet the Class A fire door fire-resistance limit, with both fire integrity and fire insulation of ≥1.5 h, excellent smoke-blocking capability, and reliable fire separation performance in fire conditions.

Function objective: smooth and flexible opening/closing, durable and reliable hardware, suitability for high-frequency daily use, and an appearance coordinated with the overall architectural decoration.

Durability objective: high structural strength, excellent anti-corrosion and anti-rust performance, a service life of ≥15 years in normal indoor environments, and no obvious deformation, sagging or rusting over long-term use.

Service objective: full-process service from design, production and installation to after-sales, complete acceptance documentation, operation training and long-term maintenance support.

4.4 Necessity of Construction

Core requirement for building fire safety. A large opening is a weak point of building fire separation. Without a qualified fire door, flame and high-temperature smoke will quickly pass through the opening to adjacent compartments during a fire, easily enlarging the fire and seriously threatening life and property. Installing a compliant Class A steel fire door is a necessary measure to implement fire separation requirements and build a solid fire-safety line of defense.

Hard requirement of fire codes and acceptance. According to GB 50016, a Class A fire door is mandatory for fire walls, important equipment rooms, Class-1 high-rise buildings and other locations. Failure to install a fire door as required, or the use of non-compliant products, will prevent fire acceptance and expose the owner to regulatory penalties. Selecting a compliant Class A steel fire door is a prerequisite for satisfying code requirements and passing fire acceptance.

Need for long-term operational safety. A high-quality steel fire door not only functions in a fire, but also provides good anti-theft, sound-insulation and heat-insulation performance in daily use, improving the overall envelope performance of the building. Durable and reliable products also greatly reduce later maintenance and replacement costs, improving the economy and safety of long-term building operation.

5. User Requirement Analysis

5.1 Basic Passage Function Requirements

The fire door must satisfy the passage requirement of the large opening. The double-leaf center-hung design supports both single-leaf independent opening and double-leaf full opening, accommodating both daily pedestrian passage and large equipment movement.

The door leaves open and close flexibly without jamming or abnormal noise; the door closer achieves smooth automatic closing with moderate closing force that will not strike personnel. The lock is easy to operate: the active leaf is equipped with a passage lever lock for quick opening from both sides, and the passive leaf is equipped with top-and-bottom bolts, normally fixed and released when a wide passage is needed.

The opening angle is ≥110°, and the fully opened door does not occupy excessive corridor space, meeting the clear width requirements of evacuation routes.

5.2 Fire and Smoke Resistance Requirements

The fire-resistance rating reaches Class A: fire integrity ≥1.5 h and fire insulation ≥1.5 h. During a fire, the average temperature rise on the unexposed face does not exceed 140℃ and the maximum single-point rise does not exceed 180℃.

Good smoke-blocking capability is required. Sealing structures are provided around the door frame, at the center stile of the double leaves and at the door bottom. The gaps remain tight at normal temperature, and in a fire the intumescent seals further seal the gaps, effectively preventing penetration of toxic smoke.

All filling materials, sealing materials and hardware must match the Class A fire-resistance rating, and must not fail, fall off or emit toxic smoke at high temperature. The overlap and gap widths between the door leaf and frame strictly comply with national standards, eliminating fire/smoke failure caused by oversized gaps.

5.3 Structural Durability and Mechanical Performance Requirements

The door leaf has good overall rigidity with wind-pressure resistance ≥1.5 kPa, showing no obvious deformation under positive and negative pressure — suitable for high-rise buildings and windward exterior locations.

Good impact resistance: daily knocks and light impacts cause no dents, deformation or coating peeling. Moving parts such as hinges and locks have a long service life and withstand ≥100,000 opening/closing cycles without damage, suitable for high-frequency use.

The steel has good anti-corrosion and anti-rust capability; the surface coating has strong adhesion, abrasion resistance and aging resistance, and under normal indoor conditions lasts ≥15 years without obvious rust or coating peeling. The door leaf shows no sagging or deformation in long-term use, the center stile and peripheral gaps remain uniform, and sealing performance remains effective over time.

5.4 Installation and Coordination Requirements

The supplier provides complete installation service covering the whole process from opening re-measurement, frame installation and leaf adjustment to sealing treatment.

Construction must coordinate with the overall project schedule, obey on-site management, and be carried out safely and in a civilized manner without affecting other work packages. Product protection must be ensured during installation to avoid scratches on the leaves and deformation of the frame, with protective measures after installation to prevent damage from cross-operation.

Construction tolerances are controlled within the code-permitted range. After installation the door leaf gaps are uniform, opening/closing is smooth and sealing is complete.

5.5 Acceptance, Delivery and After-Sales Requirements

Complete acceptance documentation is delivered, including the product certificate of conformity, 3C certification, type test report and installation inspection records, satisfying fire acceptance and project documentation filing requirements.

Operation and maintenance training is provided so that the owner’s O&M personnel master correct usage and daily maintenance skills. An overall warranty of no less than 2 years is provided, with free repair or replacement of non-artificial damage during the warranty period.

A fast after-sales response mechanism is established, with timely on-site service when faults occur, ensuring the fire door remains complete and effective at all times. After the warranty period, continued maintenance service and parts supply keep the product serviceable long term.

6. Design Principles and Applicable Standards

6.1 Applicable Standards

The design strictly follows current national laws, regulations, technical standards and codes, mainly including:

– *Fire Doors* — GB 12955-2008

– *Code for Fire Protection Design of Buildings* — GB 50016-2014 (2018 edition)

– *Standard for Quality Acceptance of Building Decoration Engineering* — GB 50210-2018

– *Classification for Burning Behavior of Building Materials and Products* — GB 8624-2012

– *Classification of Hazard Levels of Fire Effluent Toxicity of Materials* — GB/T 20285-2006

– *Code for Construction and Acceptance of Fire Resisting Installation* — GB 50877-2014

– *Carbon Structural Steels* — GB/T 700-2006

– *Continuously Hot-dip Zinc-coated Steel Sheet and Strip* — GB/T 2518-2019

– *Requirements for Product Consistency Inspection of Fire Products* — GA 1061-2013

– The opening dimensions and actual on-site conditions provided by the project

6.2 Core Design Principles

(1) Safety first. Fire-safety performance is always the first priority. All structural design, material selection and hardware matching take meeting the Class A fire-resistance limit as the premise, eliminating any design that could reduce fire performance, so that the product performs reliably in a fire.

(2) Compliance. The design strictly follows national standards and codes; product structure, material thickness and performance parameters fully meet standard requirements, ensuring the product passes fire-product certification and meets fire acceptance conditions.

(3) Durability and reliability. Structural design is optimized to improve overall rigidity and anti-deformation capability. Corrosion-resistant and wear-resistant materials and parts are selected to guarantee long-term stability and reliability and reduce later maintenance costs.

(4) Practicality and aesthetics. On the basis of fire performance, daily convenience and comfort are considered — flexible opening, effortless operation, a clean and elegant appearance and uniform coating that can be coordinated with the architectural decoration style.

(5) Economy. While ensuring performance and quality, material configuration and structural design are optimized to control production cost and deliver a high cost-performance solution balancing initial investment and long-term use cost.

7. System Architecture and Working Principle

7.1 Overall Door Type Selection Design

For the large 2970 mm x 2970 mm opening, considering passage requirements, structural stability and fire performance, a double-leaf center-hung Class A steel fire door was selected:

Door type: with an opening close to 3 m wide, a single leaf would be oversized, prone to deformation and beyond normal hinge load capacity. The double-leaf center-hung structure divides the width in half, with a single leaf clear width of about 1475 mm — more stable in structure and more flexible in use.

Material: steel is selected. Compared with timber fire doors, steel fire doors have more stable fire performance, higher structural strength, stronger impact and damage resistance and a longer service life, suitable for large-size, high-frequency use.

Fire-resistance rating: Class A is selected, satisfying the fire separation requirements of most important locations, with a wide application range and high fire-safety redundancy.

Filling material: fire-resistant rock wool is used. Rock wool is a Class A non-combustible material with excellent thermal insulation, stable chemical properties, non-toxic and harmless — the most mature and reliable filling material for steel fire doors.

7.2 Dimension Matching and Tolerance Design

Opening-to-frame matching. The opening is 2970 mm (W) x 2970 mm (H). The frame outer profile reserves 10-15 mm installation clearance on each side for adjustment and gap filling/sealing, ensuring the frame can be seated and aligned smoothly.

Frame-to-leaf matching. In the height direction, the frame inner clear height minus the total reserved top/bottom gap gives a single leaf net height of about 2870 mm; the gap between leaf and top frame is ≤3 mm and to the threshold ≤8 mm, meeting standard requirements. In the width direction, the frame inner clear width minus the center-stile overlap and side gaps gives a single leaf net width of about 1475 mm. The active leaf has a 15 mm center-stile overlap edge; after closing, the center stile gap is ≤2 mm, ensuring sealing. The leaf-to-frame overlap on both sides and top is ≥12 mm, meeting the fire door standard requirement for overlap.

Tolerance control: frame diagonal difference ≤2 mm; frame flatness ≤1 mm/m; leaf diagonal difference ≤2 mm; leaf flatness ≤0.5 mm/m; installed frame verticality deviation ≤2 mm/m; peripheral gap uniformity deviation ≤1 mm.

7.3 Three-Layer Fire-Resistance Structure System

The solution adopts a “steel shell barrier + internal thermal insulation + gap intumescent sealing” three-layer fire-resistance structure to guarantee Class A performance in all respects:

Steel shell barrier layer. The frame and leaves are formed from galvanized cold-rolled steel sheet by bending, creating a closed metal shell that directly blocks flame penetration — the first line of defense. Steel thickness is calculated strictly to ensure the structure retains strength for a short time at high temperature.

Rock-wool insulation layer. The internal cavity of the door leaf is fully filled with high-density fire-resistant rock wool, and the frame cavity is also filled, using the low thermal conductivity of rock wool to block heat transfer, reduce the unexposed-face temperature rise and ensure fire insulation — the core heat-insulation structure.

Intumescent seal anti-smoke layer. Fire-resistant intumescent seals are embedded around the frame and at the leaf center stile. At normal temperature they provide dust sealing; in a fire they expand rapidly by several to dozens of times, blocking all gaps between leaf and frame and preventing flame and smoke penetration — the key supplement for fire and smoke blocking.

In addition, at penetration points such as hinges and locks, fire-resistant reinforcement plates and thermal-insulation pads are installed inside to reduce metal heat conduction and avoid local hot spots.

7.4 Fire-Rated Hardware Fittings Design

All hardware is dedicated fire-rated hardware that has passed fire testing and matches the Class A fire-resistance rating:

Fire hinges: 3 pieces of 5-inch fire-rated bearing hinges per leaf, 6 in total. With a single leaf nearly 2.9 m high, 3 hinges evenly distribute the leaf weight, effectively preventing long-term sagging, and remain functional at high temperature so the leaf can still be opened/closed.

Fire lock: 1 set of fire-rated passage lever lock on the active leaf with latch bolt and dead bolt, meeting daily quick passage and locking needs. The lock body uses high-temperature-resistant materials and remains operable at high temperature without the bolt jamming.

Door closer: 1 hydraulic cushioning closer of 65 kg class per leaf, 2 in total. The load class matches the leaf weight and size, providing smooth automatic closing with two-stage adjustable speed, keeping the door normally closed without excessive impact.

Sequencer: 1 roller-type sequencer mounted on the top frame, ensuring the passive leaf closes first and the active leaf second, so the center-stile overlap and sealing are correct and no fire gap is created by wrong closing order.

Top-and-bottom bolts: 1 set of fire-rated top-and-bottom bolts on the passive leaf with synchronized upper/lower rods, normally fixed in the frame, manually released when a wide opening is needed.

7.5 Surface Appearance and Environmental Adaptation Design

Surface treatment: the frame and leaves are finished by electrostatic powder spraying, standard color matt grey, with custom colors available. Coating thickness is 60-80 μm, with strong adhesion, abrasion resistance and aging resistance and a smooth, neat appearance.

Appearance: the leaf uses a seamless full-panel design with a flat, clean surface, no exposed welds or screws, matching various interior decoration styles.

Identification: the fire-product identity mark (S mark) is affixed at the specified position on each leaf, clearly visible, meeting fire acceptance inspection requirements without spoiling the appearance.

Environmental adaptation: for humid, highly corrosive or other special environments, stainless steel material or an additional anti-corrosion coating can be provided to match different application scenarios.

8. Detailed Technical Design

8.1 Door Frame System

The frame is made of Q235 hot-dip galvanized cold-rolled steel sheet. The vertical frames and top frame use 1.5 mm sheet and the threshold 2.0 mm for load-bearing reinforcement. The frame is formed by integral bending with a reinforced “口”-shaped cross-section of 150 mm (W) x 50 mm (D); the internal cavity is filled with rock wool for insulation. The overall frame outer size is 2950 mm (W) x 2955 mm (H), matching the 2970 x 2970 mm opening with reserved installation clearance.

The frame is equipped with a leaf-limiting overlap edge (12 mm overlap) that blocks flame and smoke and limits the closed position, and an integral bent seal groove around the perimeter precisely matching the intumescent seal. Internally, 3 equal-angle steel stiffeners per vertical frame (upper, middle, lower) and 2 in the top frame at the hinge positions reinforce impact and load resistance. Eleven anchor ears (80 x 60 x 3 mm, 4 per vertical side at about 700 mm spacing, 3 on the top frame) with φ12 mm holes for M10 expansion bolts fix the frame to the wall by three-side fillet welding. Four corner gussets (50 x 50 mm) with M6 stainless bolts plus spot welding ensure overall frame rigidity, with joint gaps ≤0.5 mm and plane offset ≤0.3 mm.

The frame surface is electrostatically powder coated after degreasing, rust removal, phosphating and passivation, giving a 60-80 μm coating with 1-grade adhesion (cross-cut), impact strength ≥50 kg·cm, hardness ≥2H, matt gloss 20-30 (60°), salt-spray resistance ≥500 h, and artificial aging resistance ≥1000 h.

8.2 Door Leaf System

The inner and outer leaf panels are 0.8 mm Q235 hot-dip galvanized cold-rolled steel sheet, formed by integral stamping and bending with no splicing welds, four-edge 90° folded edges of 30 mm height, CNC-punched openings with ±0.5 mm accuracy, rounded corners and panel flatness ≤0.5 mm/m.

Inside, a C-shaped light-steel keel grid (1.0 mm galvanized sheet, 30 x 40 mm section) is spot-welded to the panels at ≤150 mm pitch: 4 vertical keels per leaf at ≤400 mm spacing and 3 horizontal keels at ≤600 mm spacing. The grid supports the panels, stiffens the leaf and retains the rock wool. The assembled leaf achieves wind-pressure resistance ≥1.5 kPa with maximum deflection ≤1/200 under standard wind pressure and no residual deformation after unloading.

Reinforcement plates are provided at concentrated load points: hinge reinforcement plates (150 x 300 x 1.5 mm, 3 per leaf, spot-welded to the inner panel, covering ±50 mm around each hinge) prevent hinge-area deformation and sagging; lock reinforcement plates (150 x 300 x 1.5 mm, above and below the lock body of the active leaf) and bolt reinforcement plates on the passive leaf strengthen the locally loaded zones.

The leaf uses closed top/bottom edge bands (point-welded, gap ≤0.3 mm) to prevent moisture and debris ingress, a hinge-side edge band, and on the active leaf an integral 15 mm center-stile overlap edge covering the passive leaf end face by ≥12 mm after closing, with the intumescent seal compressed between the overlap and the passive leaf end face to seal the center stile.

8.3 Fire-Resistant Filling Materials

The leaf cavity is fully filled with Class A fire-resistant rock wool boards (basalt-based, melt-spun inorganic mineral fiber): density 120 kg/m³ (deviation ≤±10%), thickness 50 mm, shot content (≥0.25 mm) ≤10%, fiber diameter 4-7 μm, thermal conductivity ≤0.040 W/(m·K) at 25℃, burning class A per GB 8624-2012, board fire-resistance limit ≥2.0 h, maximum service temperature ≥650℃, smoke toxicity ZA1 per GB/T 20285, compressive strength ≥40 kPa, point load ≥500 N, moisture absorption ≤5%, optional hydrophobicity ≥98%, dimensional change ≤1% at high temperature, and free of asbestos, formaldehyde and heavy metals.

The frame cavity is filled with rock wool strips of 100 kg/m³, Class A non-combustible, thermal conductivity ≤0.043 W/(m·K), blocking convective heat transfer inside the frame and improving insulation and sound isolation.

Filling is full and dense with no voids; cut sizes match the cavities precisely; the rock wool is kept dry during filling, and filling quality is checked before the panels are sealed.

8.4 Fire-Rated Hardware Fittings

Fire bearing hinges: 5-inch, 125 x 100 mm, 3 mm 304 stainless leaves, φ12 mm solid 304 stainless pivot with double ball bearings; single hinge load capacity ≥80 kg, opening angle ≥110°, ≥100,000 cycles without damage, opening force ≤20 N, fire-resistance limit ≥1.5 h, structural integrity at 900℃, salt-spray resistance ≥200 h.

Fire passage lever lock: double-bolt structure (anti-pick latch bolt + dead bolt with inside knob), 304 stainless housing with high-temperature-resistant engineering plastic and metal internals, φ25 mm tube lever handle, brass cylinder with pick resistance, interlock rate ≤0.001%, optional master keying; fire-resistance limit ≥1.5 h, latch remains functional at high temperature, suitable for leaf thickness 40-55 mm, field-reversible, ≥100,000 cycles.

Hydraulic cushioning door closer: 65 kg class for leaf width 900-1500 mm and leaf weight 45-65 kg; die-cast aluminum alloy body with anodized finish; precision oil cylinder with high-temperature-resistant fire-rated hydraulic oil; two-stage independent speed adjustment (closing section + latching section); maximum opening angle 180°, closing speed 10-15 s adjustable (90°→15°); fire-resistance limit ≥1.5 h; ≥500,000 cycles without leakage; parallel (standard) mounting with template.

Roller-type sequencer: 304 stainless body and rollers; mechanical roller-and-lever control ensures passive-leaf-first closing; positioning accuracy ±1 mm; ≥100,000 cycles; fire-resistance limit ≥1.5 h; noise ≤30 dB; concealed top-frame mounting with adjustable trigger position.

Fire top-and-bottom bolts: 304 stainless rods, φ12 mm solid, stroke ≥30 mm, synchronized upper/lower action from a single knob; insertion/withdrawal force ≤50 N; fire-resistance limit ≥1.5 h; ≥50,000 cycles; concealed installation with stainless bushings at the frame sockets.

Fire-product identity mark (S mark): issued by the national fire-product evaluation center, with QR code and plain/hidden codes for anti-counterfeiting and traceability, including product name, model, manufacturer, 3C certificate number and production date; one mark per leaf affixed at the inner upper-right corner.

8.5 Fire-Rated Sealing System

Graphite-based intumescent seal strip: 10 x 4 mm groove-mounted section; intumescent graphite with rubber binder and flame retardant, wrapped in stainless foil or fire-rated rubber; initial expansion temperature 200±20℃, maximum expansion ≥10 times, forming a dense stable char layer; fire-resistance time ≥1.5 h; smoke leakage at normal temperature ≤0.1 m³/(m·h) with complete gap sealing after expansion; compression set ≤20%; aging resistance 70℃ x 168 h without cracking or peeling; water resistance 72 h without swelling; halogen-free and asbestos-free; installed in the dedicated grooves of frame and leaf.

Bottom smoke stop: aluminum base (6063 aluminum, anodized) plus fire-rated silicone seal strip, base length matching the leaf width (1475 mm), silicone hardness Shore A 50±5, height 10 mm, compression 3-5 mm; fire-resistance time ≥1 h; effective bottom-gap smoke blocking; ≥100,000 friction cycles; service temperature -40℃ to 200℃; screw-mounted for easy replacement.

8.6 Installation Auxiliary Materials

Galvanized expansion bolts: M10 x 120 mm, high-quality carbon steel with hot-dip galvanized zinc layer ≥55 μm; tensile capacity ≥25 kN (concrete C25), shear capacity ≥15 kN, yield strength ≥235 MPa, salt-spray resistance ≥200 h; per GB/T 22795.

Fire-rated sealant: neutral silicone, one-component room-temperature curing, tack-free ≤60 min, full cure 24 h (25℃, 50% RH); fire-resistance limit ≥1 h, burning class FV-0, smoke density rating ≤15; movement capability ±25%, bond strength ≥0.6 MPa (steel, concrete), elongation ≥200%; service temperature -40℃ to +150℃; solvent-free, formaldehyde-free; 300 ml cartridge.

Flame-retardant polyurethane foam: B1-class (GB 8624), one-component aerosol; expansion ratio ≥60 times, closed-cell ratio ≥90%, tack-free 10 min, full cure 1 h; self-extinguishing, no molten drips, fire-resistance time ≥0.5 h; density ≥20 kg/m³, bond strength ≥0.2 MPa (concrete, steel, timber), dimensional stability ≤2% (-30℃ to +80℃), thermal conductivity ≤0.045 W/(m·K); CFC-free, ODP 0; 750 ml can, yield ≥0.03 m³ per can.

9. Recommended Configuration and Preliminary Budget

9.1 Configuration Summary

The following table summarizes the recommended configuration for one set of the 2970 mm x 2970 mm Class A double-leaf rock-wool-filled steel fire door:

No. Item Key Specification Qty Unit
1 Door frame (left/right vertical frames, top frame, threshold) 150 x 50 mm section; 1.5 mm Q235 galvanized sheet (threshold 2.0 mm); integral bending; rock-wool filled 1 set
2 Frame stiffeners and anchor ears 40 x 40 x 3 mm angle steel; 80 x 60 x 3 mm anchor ears, 11 pcs 1 set
3 Door leaves (inner + outer panels per leaf) 1475 x 2870 mm panels, 0.8 mm Q235 galvanized sheet; C-keel grid; 50 mm thick 2 sets
4 Reinforcement plates Hinge (6 pcs) + lock/bolt (4 pcs), 150 x 300 x 1.5 mm 1 set
5 Fire-resistant rock wool filling Leaf: 120 kg/m³, 50 mm; frame: 100 kg/m³; Class A non-combustible 0.53 m³
6 Fire bearing hinges 5-inch 304 stainless, double ball bearing, ≥80 kg each 6 pcs
7 Fire passage lever lock 304 stainless, latch + dead bolt, field-reversible 1 set
8 Hydraulic cushioning door closer 65 kg class, two-stage adjustable 2 pcs
9 Roller-type sequencer 304 stainless, concealed top mounting 1 pc
10 Fire top-and-bottom bolts φ12 mm 304 stainless, synchronized 1 set
11 Intumescent seal strips 10 x 4 mm graphite-based, expansion ≥10 times 12 m
12 Bottom smoke stops Aluminum base + fire-rated silicone 2 pcs
13 Electrostatic powder coating 60-80 μm, matt grey (custom colors available) 1 set
14 Auxiliary materials M10 x 120 expansion bolts (20), fire sealant (6), foam (3), screws (200) 1 set
15 Acceptance documentation Certificate of conformity, 3C certificate, type test report, S marks, installation records 1 set

9.2 Quotation Notes

The preliminary budget covers main materials (frame, leaves, filling), fire-rated hardware, auxiliary materials, transportation to site, installation and commissioning, and tax. All prices are indicative and quoted in RMB (CNY) only — no foreign-currency conversion is provided. The final quotation is confirmed by the sales engineer after the on-site survey, based on the actual opening conditions, selected configuration, surface color, quantity and delivery location, and is subject to a formal contract. Free on-site measurement, free design proposal and free technical consultation are provided before ordering; bulk projects can be served by flow-line production to shorten the average per-set cycle. Custom options such as fire-rated glass vision panels, access control integration, electromagnetic release devices, stainless steel material and special anti-corrosion coating can be added on request.

10. Technical Specifications

10.1 System Performance Summary

Item Specification
Door type Class A double-leaf center-hung steel fire door
Opening size 2970 mm (W) x 2970 mm (H)
Single leaf size Approx. 1475 mm (W) x 2870 mm (H)
Frame section 150 mm (W) x 50 mm (D), integral bent, rock-wool filled
Fire-resistance rating Class A: integrity ≥1.5 h, insulation ≥1.5 h
Fire integrity No flame/smoke penetration for ≥90 min (test standard)
Unexposed-face rise Average ≤140℃, maximum ≤180℃
Filling material Class A rock wool, leaf 120 kg/m³, frame 100 kg/m³
Wind-pressure resistance ≥1.5 kPa, max deflection ≤1/200
Opening angle ≥110°
Cycle life Hinges/lock ≥100,000 cycles; closer ≥500,000 cycles
Service life ≥15 years (normal indoor environment)
Warranty 2 years overall, lifetime maintenance support
Surface Electrostatic powder coating 60-80 μm, matt grey (custom available)

10.2 Key Component Specifications

Component Key Parameters
Door frame Q235 hot-dip galvanized sheet, 1.5 mm (threshold 2.0 mm); diagonal difference ≤2 mm; flatness ≤1 mm/m; 11 anchor ears
Door leaf 0.8 mm panels, C-keel grid (4 vertical ≤400 mm + 3 horizontal ≤600 mm); flatness ≤0.5 mm/m; 15 mm center-stile overlap
Rock wool A-class, λ ≤0.040 W/(m·K); density 120 kg/m³; max use 650℃; ZA1 smoke toxicity
Fire hinge 5-inch 304 SS, double ball bearing, load ≥80 kg, 1.5 h fire-rated
Fire lock 304 SS, latch + dead bolt, master key option, 1.5 h fire-rated
Door closer 65 kg class, 2-stage speed, 1.5 h fire-rated, 500,000 cycles
Sequencer 304 SS roller type, ±1 mm accuracy, ≤30 dB, 1.5 h fire-rated
Top/bottom bolts φ12 mm 304 SS, synchronized, ≤50 N force, 1.5 h fire-rated
Intumescent seal 10 x 4 mm, expansion ≥10x at 200±20℃, ≥1.5 h fire-rated
Bottom smoke stop 6063 Al base + silicone seal, Shore A 50±5, ≥1 h fire-rated
Expansion bolts M10 x 120, hot-dip galvanized ≥55 μm, tensile ≥25 kN
Fire sealant Neutral silicone, FV-0, movement ±25%, ≥1 h fire-rated
Fire foam B1 class, expansion ≥60x, ≥0.5 h fire-rated, ODP 0

11. Key Advantages and Customer Value

11.1 Compliance and Certification Advantage

All products are designed and produced strictly per the national standard *Fire Doors* (GB 12955), have passed the mandatory 3C fire-product certification of the national fire-product evaluation center, and are supported by complete type test reports and certificates with consistent product conformity — meeting all fire acceptance requirements and eliminating acceptance-rejection risk. All fire hardware, sealing materials and filling materials are matching same-class fire-rated products, so the whole system has no weak-link effect and the full-door fire performance is stable and compliant.

11.2 Fire Performance Advantage

The “steel shell barrier + rock-wool insulation + intumescent sealing” three-layer fire-resistance structure protects fire and smoke blocking in all respects: the steel shell directly blocks flame penetration and retains structural integrity at high temperature; the high-density rock-wool layer effectively blocks heat conduction so the unexposed-face temperature rise meets Class A requirements; the intumescent seals expand rapidly in a fire to close every gap and cut off smoke and flame paths. Both fire integrity and fire insulation exceed 1.5 hours — well above the Class A requirement — providing high fire-safety redundancy and buying sufficient time for evacuation and rescue.

11.3 Structure and Workmanship Advantage

High-precision machining with CNC bending and CNC punching delivers high dimensional accuracy, uniform fit gaps and consistent quality. The reinforced structure — keel grid plus reinforcement plates at critical points — gives high overall rigidity and excellent wind-pressure and impact resistance, so large leaves do not sag or deform over long-term use. Mature surface treatment on a fully automatic electrostatic spraying line with complete pretreatment provides strong adhesion, wear resistance, corrosion resistance and aging resistance, a smooth appearance and a long service life. Full-process inspection from incoming material and in-process checks to final outgoing inspection builds multiple quality control gates, ensuring 100% qualified outgoing products.

11.4 Customization Advantage

As a source manufacturer, the company provides strong customization capability: size customization to match the actual on-site opening and reduce field rework; configuration customization of steel thickness, rock-wool density, hardware brand and surface color to match different grades and scenarios; function customization adding fire-rated glass vision panels, access control, electromagnetic release devices and linkage modules for intelligent fire systems; and scenario customization with stainless steel material, anti-corrosion coating and explosion-proof versions for humid, corrosive and hazardous environments. The door can also be integrated with the company’s shielding equipment, computer room equipment and security systems for one-stop solutions, reducing multi-party coordination.

11.5 Full-Process Service Advantage

One-stop service covers early-stage consultation, design, production, transportation, installation, acceptance and after-sales maintenance: free on-site measurement, free design proposal and free technical consultation; self-owned production base with sufficient capacity for fast delivery of standard products and prioritized scheduling for customized products; a self-owned professional installation team with certified workers, standardized construction, reliable quality and guaranteed schedule; complete acceptance documentation with coordination for fire acceptance; and a 7×24 hotline with fast response, on-site service within 48 hours in urban areas and free repair/replacement during warranty.

11.6 Total Lifecycle Cost Advantage

Procurement cost: source-Manufacturer Supply without middleman markup, competitive pricing for equivalent configuration. Use cost: stable and reliable quality, low failure rate, simple daily maintenance, and a service life of more than 15 years in normal indoor environments without frequent replacement. Energy cost: good sealing and insulation reduce building heating/cooling loss and lower HVAC energy consumption. Risk cost: compliant products pass acceptance without rework, return, penalty or schedule-loss costs caused by unqualified products.

12. Technical Q&A (50+ Items)

12.1 Product Basics

Q1: What is a Class A steel fire door?

A: A Class A steel fire door uses steel for the frame, leaf skeleton and leaf panels, is filled with fire-insulating material, is equipped with fire-rated hardware, and achieves a fire-resistance limit of 1.5 hours. It is an important fire separation component installed at fire walls, important equipment rooms, evacuation stairwells and similar locations, preventing fire spread and smoke diffusion and safeguarding evacuation.

Q2: Why is a 2970 x 2970 mm opening fitted with a double-leaf door?

A: For structural stability and usability. A single leaf nearly 3 m wide would be too heavy, overloading the hinges and causing sagging, deformation and poor operation. The double-leaf design halves the width to about 1.47 m per leaf — more stable, with more reasonable hinge loading, flexible daily use (active leaf only) and full opening for large equipment, and it matches fire door design practice.

Q3: What is the difference between steel and timber fire doors?

A: Material: steel doors use galvanized steel sheet shells with fire-filling material; timber doors use flame-retardant timber or plywood. Performance: steel doors are stronger, more impact-resistant and more durable, with more stable fire performance; timber doors look warmer but are weaker in moisture and deformation resistance. Application: steel suits industrial buildings, equipment rooms, garages and pipe shafts; timber suits hotels, offices and civil buildings with high aesthetic requirements. This solution uses steel for the large opening and high-frequency use.

Q4: How are fire door ratings classified and where is each used?

A: Per GB 12955, fire doors are classified by fire-resistance limit: Class A ≥1.5 h for fire walls, important equipment rooms (distribution rooms, fire control rooms), flammable/explosive warehouses; Class B ≥1.0 h for evacuation stairwells, anterooms, fire-elevator lobbies and ordinary compartment walls; Class C ≥0.5 h for pipe shafts, cable shafts and refuse chute anterooms. This solution is Class A, covering most high-requirement fire separation scenarios.

Q5: How heavy is this door and what wall load is required?

A: A 2970 x 2970 mm Class A double-leaf steel fire door weighs about 180-220 kg total, about 90-110 kg per leaf. The weight transfers through the frame to the surrounding wall; ordinary concrete and solid brick walls carry it easily without extra reinforcement. Lightweight steel-stud partition walls need reinforcement beforehand; we can check the wall and provide a reinforcement plan.

Q6: Can the threshold be omitted? Does it affect fire performance?

A: Yes. For level, barrier-free floors the threshold can be omitted and a bottom smoke stop substitutes for the bottom seal. As long as the bottom gap meets the standard (≤8 mm) and the smoke stop is fitted, fire and smoke performance still meets code without affecting the rating. This solution defaults to a threshold and can be changed to a threshold-free version.

Q7: What is the standard thickness of a steel fire door?

A: The leaf is generally 45-55 mm; this solution uses 50 mm, the mainstream thickness for Class A doors, accommodating sufficient fire rock wool for insulation. Frame depth into the wall is generally 100-150 mm; this solution uses 150 mm, adaptable to most wall thicknesses and customizable.

Q8: Are there requirements for the door opening direction?

A: Yes. Per fire code, fire doors on evacuation routes must open in the direction of evacuation so people can push through. The specific direction (left-hand, right-hand, double-leaf) is determined by the site evacuation direction; we can produce the matching direction.

Q9: How good is the sound insulation?

A: Steel fire doors have inherent sound insulation; rock-wool filling plus sealing gives an airborne sound insulation of about 25-30 dB, meeting ordinary needs. Upgrades — sound-insulating seals, extra insulation layers, thicker steel — can raise this above 40 dB.

Q10: Can a glass vision panel be added without lowering the rating?

A: Yes, with a Class A fire-rated glass of matching rating and code-compliant size and installation. Common sizes are 300 x 600 mm and 400 x 600 mm, custom sizes available. This solution defaults to no vision panel.

12.2 Fire Performance

Q11: What exactly does the 1.5 h Class A fire-resistance limit mean?

A: It covers two indicators, both required for Class A: fire integrity — the door resists flame and high-temperature smoke penetration for 1.5 h in the standard fire test (not burned through, no flame on the unexposed face); and fire insulation — the unexposed-face average temperature rise ≤140℃ and maximum single-point rise ≤180℃, i.e. the back face will not ignite combustibles. Both must pass simultaneously.

Q12: Why fill with rock wool? Can other materials be used?

A: Rock wool is the mainstream, most mature filling material for steel fire doors; its core role is insulation. Steel panels alone block flame but conduct heat quickly, so without insulation the unexposed face would overheat. Rock wool is Class A non-combustible with low thermal conductivity, stable at high temperature without melting or collapsing, non-toxic, and cost-effective. Alternatives (perlite, aluminum silicate fiber) have drawbacks — perlite is heavy and prone to powdering, aluminum silicate is costly. Rock wool is the best overall choice and the most recognized filling for fire certification.

Q13: How does the intumescent seal work?

A: It is a seal strip that expands when heated. Normally a thin strip embedded in frame/leaf gaps for dust and sound sealing; in a fire, at about 200℃ it rapidly expands more than 10 times to form a dense char layer that completely blocks the gaps between leaf and frame, stopping flame and toxic smoke. Simply: an ordinary seal at normal temperature becomes a “fire plug” in a fire.

Q14: Is the center stile of a double-leaf door a fire weak point?

A: It is a critical sealing area, protected here by three measures: the active leaf’s 15 mm overlap edge physically covers the stile; an intumescent seal at the stile is compressed on closing for normal-temperature sealing; and in a fire the seal expands to fill all gaps. The combination keeps stile performance equal to the rest of the door — not a weak point.

Q15: Does the bottom gap leak smoke? How is it handled?

A: A bottom gap (normally ≤8 mm) is necessary for free operation. A dedicated bottom smoke stop is fitted, closely contacting the floor/threshold to block smoke penetration; in a fire, combined with the peripheral intumescent seals, full-perimeter sealing is achieved. For threshold-free floors, an automatic drop-down smoke stop can be supplied.

Q16: Must the hardware be fire-rated? Why not ordinary hardware?

A: Yes — fire-rated hardware is mandatory. Ordinary hinges and locks deform, jam, melt or detach at high temperature, leaving the door unable to open/close and losing its fire separation function. Fire-rated hardware uses high-temperature-resistant materials and special structures, remaining intact and functional through 1.5 h of high temperature. National codes require certified fire-rated hardware on fire doors.

Q17: Is higher rock-wool density always better? Is 120 kg/m³ enough?

A: No — density and insulation are not linear. Within a range, higher density improves insulation, but excessive density adds weight, loads the hardware and raises cost. 120 kg/m³ is the standard density for Class A steel fire doors, verified by extensive testing and field use to fully meet the 1.5 h insulation requirement — the best balance of performance, weight and cost.

Q18: Can a fire door completely stop smoke?

A: A qualified door with good installation sealing blocks the vast majority of smoke, but absolute zero leakage is not realistic — smoke penetrates tiny gaps under pressure differentials. The door’s core role is to greatly slow smoke spread and buy evacuation time. With intumescent seals closing the gaps in a fire, leakage drops to extremely low levels, well within code requirements.

Q19: Will the steel door burn hands?

A: In a fire, steel conducts heat, but the internal rock-wool layer greatly slows heat transfer. Per standard, the Class A unexposed-face average rise is ≤140℃ and maximum ≤180℃ — the overall panel temperature; brief contact will not cause severe burns and doors remain openable for evacuation. At normal temperature the panel is at ambient temperature.

Q20: Does the door provide anti-theft protection?

A: It has some anti-theft capability — a strong steel shell and fire lock resist prying better than ordinary interior doors — but it is not equivalent to a dedicated anti-theft door: fire doors are designed for fire performance, anti-theft doors for break-in resistance and lock security under different standards. For high anti-theft requirements, an anti-theft fire lock and thicker steel can be upgraded.

12.3 Structure and Material

Q21: What steel is used for the frame and leaves, and how thick?

A: Q235 hot-dip galvanized cold-rolled steel sheet — the most common quality carbon structural steel with good strength, bending and welding performance; the galvanized layer prevents rust and extends life. Frame main material is 1.5 mm (threshold 2.0 mm for load); leaf panels 0.8 mm; internal keels 1.0 mm; reinforcement plates at hinges/locks 1.5 mm. This configuration meets Class A requirements while balancing strength and cost.

Q22: Why galvanized steel instead of ordinary cold-rolled?

A: Rust resistance. Ordinary cold-rolled steel has no protective layer and rusts in moisture, corroding the sheet, reducing strength and shortening life. Hot-dip galvanizing creates a dense zinc layer isolating air and moisture — several times more rust-resistant — and even if the coating is slightly damaged, cathodic protection prevents rust. Fire doors are long-life fire equipment and must not fail; galvanized substrate is essential.

Q23: What is the keel grid for? Can it be omitted?

A: The keel is the leaf “skeleton” and is essential: it supports the structure and flatness, prevents panel denting and deformation; it stiffens the leaf against wind pressure and impact, preventing a large leaf from feeling soft or shaking; and it retains the rock wool, preventing shifting and settling so insulation stays stable. Without keels, two thin steel panels would be weak, easily deformed, and the filling could not be retained.

Q24: Why reinforcement plates at hinges and locks?

A: Hinges and locks are concentrated load and high-frequency wear points. Hinges carry the whole leaf weight; long-term stress can deform the panel and loosen screws, causing sagging. Locks take repeated impact from daily use, which can deform the lock area and loosen screws. Thickened plates spread stress and raise local strength, greatly reducing deformation and loosening, keeping the leaf from sagging and the lock firm — essential for large, heavy leaves.

Q25: Electrostatic powder coating vs. paint — which is better?

A: Powder coating (spraying) outperforms traditional painting and is the mainstream finish for fire doors: stronger adhesion (no peeling), harder and more scratch-resistant coating, environmentally friendly (solvent-free, no formaldehyde/VOC), denser corrosion protection, and a more uniform, level appearance without runs or color difference. This solution uses electrostatic powder coating in matt grey — attractive and durable.

Q26: Will there be weld marks on the leaf surface?

A: No. The outer panel is formed by integral stamping and bending with no exposed welds; all welding (keels, reinforcement plates) is done internally and does not affect the outer surface. Finished leaf flatness is within 0.5 mm/m, smooth and level with no weld marks, dents or burrs.

Q27: Will the steel door rust? How long does it last?

A: Under normal indoor dry conditions, it will not rust. The product has double rust protection — galvanized substrate plus electrostatic powder coating — and will not rust as long as the coating is not extensively damaged. With normal use and regular maintenance, service life exceeds 15 years; hardware lasts 5-8 years and can be replaced to continue use. For humid or corrosive environments, stainless steel or special anti-corrosion coatings are available.

Q28: What are the anchor ears for? Is 11 enough?

A: Anchor ears are the fixing elements connecting frame to wall — welded to the frame exterior and fixed to the wall with expansion bolts, anchoring the frame firmly in the opening. Their count and spacing directly affect frame rigidity. This solution provides 4 per vertical side (about 700 mm spacing, 150 mm from corners) and 3 on the top frame — 11 total, fully meeting installation code, firm and able to bear the leaf weight and opening impact without loosening or shifting.

Q29: What does the center-stile overlap do? Is 15 mm enough?

A: The overlap is an extended edge on the active leaf covering the passive leaf end face. It physically shields the center stile from direct flame/smoke penetration and lengthens the sealing path for better sealing with the seal strip. 15 mm is the industry-standard design; after installation clearance, actual overlap is about 12 mm, fully meeting fire code — sufficient sealing without causing jamming or collision.

Q30: Why is the threshold 2.0 mm — thicker than the frame?

A: The threshold sits at floor level and is frequently stepped on and rolled over, especially where carts and equipment pass — far more pressure and wear than the vertical frames. It is thickened to 2.0 mm for higher load capacity and wear resistance, preventing deformation and wear damage. For pedestrian-only passages without heavy traffic, 1.5 mm is also available.

12.4 Installation and Construction

Q31: What is the installation process for a steel fire door?

A: Standard steps: opening pretreatment (clean, check size/verticality, repair deviations); line marking (center and level lines); frame seating and correction (temporary wedges, align verticality/levelness with level and plumb bob); permanent fixing (drill at anchor ears, install and torque expansion bolts, re-check); gap filling (flame-retardant foam, trim after cure); sealant application (fire sealant on both sides); leaf hanging (install hinges, hang leaf, adjust gaps and smoothness); hardware installation (lock, closer, sequencer, bolts, test each function); product protection (clean, protection film); self-inspection and handover.

Q32: What gap should be left between frame and wall, and what fills it?

A: 10-15 mm per side for seating and adjustment. Filling has two steps: internal — B1 flame-retardant polyurethane foam, expanding to fill the whole gap, fixing, insulating and sound-proofing with flame-retardant performance; surface — neutral silicone fire sealant on both sides for sealing and aesthetics. Ordinary cement mortar is forbidden — it cracks and falls, seals poorly and corrodes the galvanized layer.

Q33: What are the gap standards after installation, and how is uniformity ensured?

A: Per code: leaf-to-frame overlap ≥12 mm; side gaps ≤3 mm; top gap ≤3 mm; bottom gap ≤8 mm; center stile gap ≤2 mm. Installers adjust hinges and frame alignment, re-testing gaps repeatedly to ensure uniform, compliant gaps.

Q34: Why is a sequencer mandatory on double-leaf doors?

A: The sequencer guarantees correct closing order. Double-leaf doors have active and passive leaves; correct order is passive first, active second, so the active leaf’s overlap edge lands correctly on the passive leaf and the stile seals tightly. Without it, random order — often active first — leaves the stile unsealed with a large gap, failing fire and smoke separation. Fire code therefore requires a sequencer on double-leaf fire doors.

Q35: How do I adjust the door closer speed?

A: The closer body has two adjustment valves for the closing section (90°→15°) and latching section (15°→0°); turn clockwise to slow, counterclockwise to speed up. Adjust in small increments and test. Closing speed should be moderate — too slow defeats the normally-closed requirement, too fast can strike people; latching can be slightly faster to ensure full closure against wind. Do not screw valves fully shut or out, to avoid oil leakage. We pre-adjust at installation and can fine-tune after handover.

Q36: What are the requirements for the opening? What if it is not square?

A: A qualified opening: size deviation within tolerance, square, vertical and level, with a solid wall able to take expansion-bolt tension. Oversized, out-of-square or loose walls need rectification first — mortar repair, chiseling, or wall reinforcement. We check the opening during the survey and provide rectification advice; on request we can perform the rectification.

Q37: When during decoration is the best time to install?

A: After wall plastering and floor leveling are complete and before final wall finishing (painting, tiling). The opening is then dimensionally stable, frame positioning is accurate, and later wall work covers the frame-side gaps for a neat finish. Too early risks damage from cross-operation; too late makes gap finishing difficult. If constrained, install the frame first and leaves/hardware last, with product protection.

Q38: Can a steel fire door be installed on a lightweight steel-stud partition?

A: Yes, but reinforcement is mandatory — the partition alone is too weak; the door’s opening force would loosen the wall and deform the frame. Reinforcing square or channel steel must be added at both sides of the opening, connected to the structure, with the frame fixed to the reinforcement; the wall should be filled with fire rock wool so its fire performance matches the door. We provide a professional reinforcement plan per wall condition.

Q39: How long does installation take for one door?

A: 2-3 days for a single door: frame installation and fixing 1 day, gap filling and curing half a day, leaf hanging and hardware commissioning 1 day; 2 days with good site conditions. Batch installation can use flow-line operations with shorter average per-door time. The schedule is arranged with the overall project plan.

Q40: How is the door protected after installation?

A: Basic protection is provided at installation: factory protection film retained on frame and leaves, corner guards on edges. Site cooperation is requested: no hanging loads or leaning items on the leaves; shield the door during cross-operation to avoid cement/paint splashes; avoid impacts from carts; keep protection film until final acceptance. Minor scratches can be touch-up repaired; seriously damaged parts can be replaced.

12.5 Acceptance and Compliance

Q41: What documentation is required for fire door acceptance?

A: Complete acceptance documentation includes: product certificate of conformity; 3C mandatory certification; type test report; fire-product identity marks (S marks) and query certificates; hardware test reports and certificates; installation inspection and concealed-work records; as-built drawings. We deliver the full set stamped by the manufacturer, meeting fire acceptance and filing requirements.

Q42: What does the fire authority mainly check at acceptance?

A: Qualification documents (3C, test report, certificate validity and model consistency); identity marks (S marks present and traceable); appearance and structure (no damage, deformation, correct steel thickness); hardware (fire-rated hinges, locks, closers, sequencers complete and functional); sealing (seals intact, gaps compliant, tight closure); opening function (smooth operation, automatic closing, sequencer order, lock function); and fixing firmness. Our products and installation meet all checks.

Q43: Can a non-standard-size fire door pass fire acceptance?

A: Yes — if the manufacturer holds 3C certification for the series and the non-standard size falls within the certified coverage, with structure, materials and performance identical to the certified standard product. Our Class A certification covers widths/heights up to 2400 x 3000 mm; the 2970 x 2970 mm size is within coverage and fully compliant.

Q44: Where is the 3C mark, and how do I verify authenticity?

A: The fire-product identity mark (S mark) is affixed at the upper-right corner of the leaf interior — a QR-coded red or white label. Verify by scanning the QR code into the fire-product information query system, or entering the plain code on the official fire-product evaluation center website. The record shows product name, model, manufacturer, certificate number and production date; matching information confirms authenticity.

Q45: Which locations must have Class A fire doors?

A: Per GB 50016: doors/windows/openings in fire walls; boiler rooms, transformer rooms, diesel generator rooms, oil storage rooms; fire control rooms, fire pump rooms, HVAC plant rooms; refuge floors and refuge rooms of Class-1 high-rise public buildings; underground/semi-underground entertainment venues; flammable/explosive warehouses and tank farm separations; and doors between civil-air-defense compartments. In short, the higher the fire risk, the higher the required rating.

Q46: Can a fire door be modified privately (access control, lock change, holes)?

A: No. Fire door structure and parts are validated by fire tests; private modification destroys fire structure, lowers performance, makes the product inconsistent with certification, fails acceptance and leaves safety hazards. Adding access control, changing locks or adding vision panels must be done by the original manufacturer or a qualified party, preserving fire performance and product consistency. Consult us first for compliant modification solutions.

Q47: Can a normally-closed fire door be held open?

A: No. Normally-closed doors must remain closed so they function in a fire. Propping them open with door stops or latches means they cannot close in a fire — the separation function is lost; this is a fire-code violation subject to rectification orders and penalties. If a door must stay open, use a normally-open fire door with electromagnetic release and linkage control that closes automatically on fire alarm.

Q48: What are common acceptance failures?

A: Products without valid 3C certification or mismatched certification; use of counterfeit products; missing fire hardware (no closers or sequencers, or ordinary hardware substituted); missing or damaged seals with oversized gaps and poor closure; insecure installation with loose frames, sagging or deformed leaves; unauthorized modification (illegal holes, part replacement); missing or false identity marks; incomplete documentation. Choosing a compliant manufacturer and standard installation avoids these.

Q49: How long is the type test report valid?

A: The type test report itself has no fixed expiry as long as the product standard is unchanged, the product structure has no major change and the certification remains valid. The 3C certificate is valid for 5 years and requires renewal review before expiry. Our certifications stay current, so delivered documentation is always up to date.

Q50: Is the manufacturer needed on site for acceptance?

A: On request we arrange technical staff to support acceptance — answering questions, demonstrating functions and assisting with documentation. For local projects this support is free; for remote projects it can be arranged as conditions allow.

12.6 Maintenance and Care

Q51: How should the steel fire door be maintained daily?

A: Cleaning — wipe with a soft dry cloth, avoid strong acids/bases that corrode the coating; inspection — regularly check for deformation, damage, seal aging/falling, loose hardware; lubrication — oil hinge pivots, latch and bolts every six months for smooth operation and rust prevention; adjustment — have closer speed, gap uniformity and jamming corrected promptly; prohibitions — no hanging loads, no hard impacts, no private disassembly or modification.

Q52: How often should hinges be oiled, and with what?

A: Every six months to a year, or sooner for high-frequency use. Use mechanical oil, sewing machine oil or a dedicated hardware anti-rust lubricant — not cooking oil or grease, which attract dust and accelerate wear. Apply a few drops to the hinge pivot and cycle the door several times to work the oil in; no hinge disassembly needed.

Q53: What if the door closer leaks oil?

A: Leakage means the seal is damaged; hydraulic oil loss reduces closing force and speed control, possibly preventing automatic closing — a safety hazard in a fire. Minor leakage may be temporarily tolerated, but replace the closer promptly; serious leakage requires immediate replacement. Normal closers last about 500,000 cycles (5-8 years) without leaking; early leakage indicates quality or adjustment issues — free replacement within warranty.

Q54: How often should the intumescent seal be replaced?

A: In normal indoor environments, service life is 8-10 years. Inspect regularly; replace if hard, cracked, detached, elastic loss or failed expansion. After a fire, the seal chars and fails — it must be replaced to restore fire performance. Original-equipment seal replacement is available.

Q55: How do I repair coating scratches?

A: Light scratches can be touched up with same-color touch-up paint, nearly invisible. Large or deep scratches or peeling need professional re-spraying: grinding, rust removal, same-color powder coating and curing to restore appearance and rust protection. Non-artificial coating issues within warranty are repaired free; artificial damage is repaired for a fee.

Q56: The leaf sags slightly and rubs the floor — how to adjust?

A: Slight sag after long use usually comes from loose or slightly deformed hinges. First tighten all hinge screws; if sag persists, adjust the hinge eccentric pin or add shims to lift the leaf; for serious sag, check the reinforcement plates and consider heavier hinges. Professional adjustment is recommended to avoid damaging hinges or uneven gaps; free on-site adjustment within warranty.

Q57: The lock is stiff — what to do?

A: Common causes and fixes: latch/strike misalignment — adjust the strike plate; dry cylinder — blow in graphite powder or dedicated lock lubricant (not oil, which attracts dust); leaf deformation shifting the lock — adjust leaf verticality and gaps; internal wear — replace lock body or cylinder. Avoid excessive force and twisting keys to extend lock life.

Q58: When should the bottom smoke stop be replaced?

A: It wears from floor friction; replace when wear is severe enough to leak smoke. Normal life is about 3-5 years. Replacement is simple — remove fixing screws and fit a same-specification stop. Check bottom sealing periodically and replace promptly to maintain smoke blocking.

Q59: The door is stiff in winter and smooth in summer — why?

A: Thermal expansion/contraction. Steel and seals expand and contract slightly with temperature; in winter, contraction reduces the gaps and the door feels tight; in summer, larger gaps make it smooth. Unless severely jammed, this does not affect use. If winter operation is very tight, slightly adjust the hinges to enlarge the gap for year-round smoothness.

Q60: What is the warranty period and scope?

A: 2 years overall warranty from acceptance date. Scope: product quality issues — steel rust-through/perforation, large-area coating peeling, leaf frame deformation, non-artificial hardware failure — repaired or replaced free on site. Excluded: artificial damage, misuse, force majeure (impact deformation, private modification, corrosive-liquid damage). After warranty, lifetime maintenance at cost-only parts and reasonable service fees.

13. Construction Schedule

13.1 Overall Period

For the single 2970 mm x 2970 mm Class A double-leaf steel fire door project, the total schedule is planned at 13 calendar days, covering construction preparation, on-site survey, frame installation, gap filling and sealing, leaf installation, hardware commissioning, finishing and acceptance. For batch projects, flow-line operation can be adopted to compress the average per-door duration according to quantity.

The schedule starts when the site is ready for installation, the opening rectification is completed and the owner confirms the solution, and ends at qualified completion acceptance and handover of documentation.

13.2 Stage Schedule

Stage Work Days Responsible Acceptance node
1. Preparation Drawing review, technical disclosure, material production and stocking, crew mobilization, tools and site facilities 3 Project manager Start-condition acceptance
2. Survey and marking Re-measure opening size/level/verticality, check wall strength, mark center/level lines and bolt points 1 Foreman, technical lead Survey record confirmation
3. Frame installation and fixing Seat frame, wedge temporarily, correct verticality/levelness/diagonal, drill and torque expansion bolts, weld key points, re-check 2 Installers, QC Frame concealed-work acceptance
4. Gap filling and sealing Clean gaps, inject flame-retardant foam, trim after cure, apply fire sealant both sides, fill frame cavity with rock wool 1 Installers Sealing acceptance
5. Leaf hanging and adjustment Install hinge leaves, hang leaf, adjust gaps, test smoothness, correct verticality/flatness 2 Installers, foreman Leaf initial acceptance
6. Hardware installation and commissioning Install fire lock, top/bottom bolts, closers, sequencer, guard plates; full-function joint test 2 Installers, QC Hardware function acceptance
7. Finishing and self-inspection Clean surfaces, affix S marks, check protection film, full self-inspection and rectification, compile records 1 Foreman, QC Completion self-inspection
8. Acceptance and handover Support owner/supervision acceptance, rectify issues, hand over documentation, on-site O&M briefing 1 Project manager, technical lead Completion acceptance

13.3 Schedule Assurance

Material assurance: standard products are stocked in advance, non-standard products receive priority scheduling, and production is tracked throughout to ensure on-time dispatch; incoming materials are inspected for quality and completeness before delivery to avoid shortages or defects delaying the schedule.

Personnel assurance: an experienced fixed installation crew with certified workers is assigned, with advance technical and safety disclosure and standby personnel for additional scope or schedule compression.

Tooling assurance: sufficient and well-maintained tools — rotary hammers, drills, laser levels, caulk guns — are checked and serviced before mobilization, with standby units on site to prevent downtime.

Plan control: work strictly follows the schedule; daily pre-shift meetings set tasks and post-shift reviews track progress; the project manager monitors throughout and immediately analyzes and recovers any slippage.

Cross-discipline coordination: advance communication with other site contractors defines working windows and handover areas to reduce interference; parallel work packages are synchronized to compress the total duration.

Contingency: emergency plans for weather, opening-rectification delays and transport delays reserve buffer time, keeping the overall schedule controllable.

13.4 Progress Control and Early-Warning Mechanism

Daily report: a daily construction report records completed work, personnel and tooling, issues and next-day plans, giving the owner real-time visibility.

Node acceptance: each key stage is accepted before the next begins, avoiding rework and schedule loss from later defects.

Slippage warning: if actual progress falls more than 1 day behind plan, an alert is raised and the project manager analyzes causes and adds personnel or working time to recover.

Coordination meeting: weekly site coordination meetings report progress and resolve cross-operation and site issues.

14. Construction Organization and Quality/Safety Measures

14.1 Organization Structure

The project adopts a project-manager responsibility system with a professional crew: 1 project manager (overall responsibility for schedule, quality, safety, cost and coordination); 1 technical lead (disclosure, solution execution, quality control, technical problem solving, acceptance documentation); 1 foreman (crew management, task allocation, work sequencing, site discipline); 3 installers (frame installation, leaf adjustment, hardware installation, sealing); 1 QC inspector (process inspection, concealed-work acceptance, finished quality); 1 safety officer (site safety education, inspection, measures, civilized construction supervision).

14.2 Position Responsibilities

Project manager: liaises with the owner and supervision, coordinates all parties, resolves issues; develops the schedule and allocates personnel, materials and tooling; controls quality and safety overall; manages cost; organizes completion acceptance, documentation handover and warranty follow-up.

Technical lead: prepares technical solutions and disclosures per drawings and codes; guides site work, solves technical problems and corrects non-standard operations; verifies survey and setting-out accuracy; compiles complete technical and acceptance documentation; participates in quality inspection and defines rectification plans.

Foreman: leads the crew to complete daily tasks on schedule; enforces code-compliant, specification-grade work; manages site personnel, tooling and materials; enforces safety and civilized-construction rules; keeps work records and reports issues promptly.

Installers: master the fire door installation process and perform all operations per code; use and maintain tools correctly; deliver qualified workmanship; wear PPE and observe safety rules; protect finished work and site facilities.

QC inspector: inspects incoming materials and parts, rejecting unqualified items; inspects and accepts each process, blocking handover of unqualified upstream work; focuses on frame verticality, gap sizes, fixing firmness and sealing quality; records findings, raises rectification requirements and tracks closure; supports fire acceptance.

Safety officer: conducts safety education and disclosure before mobilization; daily site safety patrols, hazard identification and violation stops; manages temporary power, work-at-height and hot-work safety; checks PPE and fire equipment; reports and participates in incident handling.

14.3 Pre-Construction Preparation

Technical preparation: the crew studies drawings, product documentation and codes to clarify quality and acceptance standards; technical and safety disclosures cover process, key points and precautions; a detailed solution and schedule define methods and quality control points; measuring and testing instruments are calibrated and valid.

Material preparation: all materials — frame, leaves, hardware, filling, auxiliary materials — are prepared per the configuration list; incoming inspection verifies model, specification, quantity, appearance and certificates, with unqualified items returned; materials are stored classified and labeled with moisture, impact and theft protection; spare fragile parts are kept to avoid schedule impact.

Tooling preparation: rotary hammer (26-type, 2), hand drill (13 mm, 2), 2-line laser level (1), plumb bob (5 m, 2), steel tapes (5 m/30 m), adjustable wrenches (8-12 in, 4), screwdriver sets (2), caulk guns (2), foam guns (2), hammer and chisels (2 sets), portable cutter (1), helmets and harnesses (5 sets) — all inspected and serviced before mobilization.

Site preparation: confirm the opening is complete and ready with debris cleared; arrange temporary power with safe, reliable supply; plan material and tool storage areas keeping the site tidy without blocking other work; set up safety signs and control access to the working area.

14.4 Core Construction Processes

Frame installation: check and clean the opening (size, verticality, wall strength, remove loose parts, repair deviations); mark center and level lines and anchor points; seat the frame and wedge temporarily at corners and mid-span; correct verticality (≤2 mm/m), levelness (≤2 mm/m), position and diagonal (≤3 mm) with the laser level and plumb bob by adjusting the wedges; drill at each anchor ear, clean the holes, install and symmetrically torque the expansion bolts while monitoring frame accuracy; re-check all indicators after fixing.

Gap filling and sealing: clean the frame-wall gaps and dampen lightly; inject flame-retardant foam from bottom up until full, avoiding overfill that deforms the frame; after full cure (about 1 hour), trim flush with a knife; apply masking tape for straight joints, apply neutral silicone fire sealant on both sides with uniform, smooth, bubble-free beads, remove tape and dress the edges; fill the frame cavity with rock wool.

Leaf installation and adjustment: mark hinge lines on frame and leaf with upper/lower hinges on one vertical line; fix hinge leaves with screws fully seated, flush with surfaces; two workers lift the leaf onto the pivots and secure the end caps; cycle the door to check gap uniformity and smoothness, adjusting hinge screws and shims for side/top gaps ≤3 mm, bottom gap ≤8 mm, center stile gap ≤2 mm with aligned overlap, opening angle ≥110°, no jamming, rubbing or noise; hold the leaf open to verify hinge load capacity with no self-closing or sagging.

Hardware installation: fit the fire lock (open holes per template, install body, cylinder and levers, align latch and strike, test smoothness and dead-bolt function); install the top/bottom bolts on the passive leaf (adjust rod length, verify insertion into the frame sockets, smooth and firm); install closers per template (fix body and linkage, adjust the two speed valves for smooth automatic closing with moderate force and no slamming); install the roller sequencer on the top frame and verify passive-first/active-second order with tight stile sealing; test every part and tighten all screws.

14.5 Quality Control and Acceptance Standards

Key control points: fixing firmness — bolt count and spacing per code, frame immovable by hand, all hardware screws present and tight; dimensional accuracy — frame verticality, levelness and diagonal within tolerance, uniform leaf gaps within limits; sealing quality — seals continuous, firm and intact, foam fully filled, sealant smooth and continuous without bubbles or breaks; operating performance — smooth, stable opening/closing without jamming, rebound or noise, automatic closing functional, sequencer order correct; appearance — no scratches, dents or deformation on frame/leaves, coating intact, neat joints and no site waste.

Acceptance standards applied: GB 50877-2014 (construction and acceptance of fire-resisting installations), GB 50210-2018 (quality acceptance of building decoration engineering), GB 12955-2008 (fire doors).

14.6 Safety and Civilized Construction Management

Safety: all personnel wear helmets, harnesses for work at height and non-slip shoes; no work under the influence of alcohol; temporary power complies with code — qualified distribution boxes and cables, one machine one switch one RCD, no unauthorized wiring; power tools used per operating rules with protective eyewear; hot work requires prior application, fire extinguishers, a designated fire watcher and confirmation of no ignition source before leaving; heavy leaves and frames are moved by multiple workers under unified command to prevent crushing injuries; power is cut and the site checked each evening.

Civilized construction: materials and tools are stacked neatly, classified and labeled, never blocking fire lanes or exits; noise is controlled with high-noise work avoided during rest hours; the site is cleaned daily — work finished, site clean; finished decoration and facilities are protected; workers dress neatly, observe site rules and communicate politely.

14.7 Finished Product Protection

Factory protection: PE protection film on frame and leaf surfaces, paper corner guards, firm packaging against transport damage.

Handling protection: lift and place gently, vertically to avoid leaf deformation; hardware packed separately to avoid scratching the coating.

During installation: avoid tool and material impacts; mask around drilling and caulking to prevent contamination.

After installation: retain the protection film until final acceptance; fit impact corner guards at frame corners against carts and materials; install bottom guards against mud and debris.

Cross-operation protection: cover the door with tarpaulin or protection boards during plastering and painting; notify all site personnel — no stepping, hanging loads, hammering or scratching on the leaves.

15. After-Sales Service

15.1 Warranty Commitment

Warranty period: 2 years overall from qualified completion acceptance.

Warranty scope: during the warranty, all product-quality and installation-quality issues are repaired or replaced free of charge until normal function is restored, including: non-artificial rust-through/perforation or structural deformation of frame and leaf steel; non-artificial large-area peeling, cracking or discoloration of the coating; non-artificial failure, fracture or deformation of fire hardware; non-artificial detachment, aging or sealing failure of seals; and installation-related frame loosening, leaf sagging, uneven gaps or poor operation.

Exclusions: artificial impact, scratching, modification or misuse; force majeure (fire, flood, earthquake); damage from third-party disassembly or repair; damage from long-term high-humidity, high-corrosion or strong-acid/alkali environments without special treatment; normal wear of consumables. Paid repair service is available for excluded items.

15.2 Fault Response and Handling Mechanism

A 7×24 hotline accepts reports, consultations and complaints at any time. Response: within 1 hour of a report, telephone response with remote guidance; within 48 hours for on-site service in urban areas; up to 72 hours for remote districts. Handling: general faults repaired on site and verified; complex faults — explain cause and plan, agree a repair time and complete with parts as soon as possible; urgent faults affecting fire safety receive priority dispatch. Every service visit produces a signed repair record (cause, measures, parts, result); a follow-up call is made within 3 working days to confirm resolution and satisfaction.

15.3 Daily Maintenance Guidance

At handover, technical staff give the owner’s O&M personnel an on-site briefing on usage, daily care and common minor issue troubleshooting. A *Product Use and Maintenance Manual* is delivered covering structure, operation, maintenance cycles, key points, safety notes and contact channels. During warranty, semi-annual reminders by phone or messaging prompt routine inspection and seasonal care. Maintenance consultations are answered at any time with remote guidance for simple tasks such as closer speed adjustment, hinge oiling and lock lubrication.

15.4 Post-Warranty Services

Lifetime maintenance support with cost-only parts and reasonable service fees. Annual maintenance agreements provide two scheduled on-site inspections per year — hinge/lock cleaning and lubrication, leaf gap and closer speed adjustment, seal inspection and small-area replacement, screw tightening and appearance cleaning — with priority response and no service fee. Original spare parts remain available long term at transparent prices. Upgrade services include access control integration, higher-grade hardware replacement and anti-corrosion upgrades.

15.5 Service Supervision and Customer Follow-Up

A service complaint hotline accepts feedback; complaints receive a response within 24 hours and are seriously handled. Regular follow-up: first visit 1 month after handover; an annual comprehensive visit during warranty; a proactive reminder 1 month before warranty expiry with continuation options. A dedicated customer file per project records product information, installation, repairs and follow-ups for lifecycle tracking.

16. Training Plan

16.1 Training Objectives

Enable the owner’s users to operate the fire door correctly, safely and per code; enable O&M personnel to perform daily inspection and basic maintenance, identify common issues and handle simple faults; enable management to understand fire-code requirements and manage the doors to remain complete and effective; improve use efficiency, extend service life and reduce maintenance cost.

16.2 Training Audience

Property/O&M personnel (daily patrol, care, simple fault handling — primary audience, full curriculum); security personnel (patrol and emergency operation — operation and emergency response focus); management leads (fire-safety management — code requirements, management points and reporting process focus).

16.3 Training Content System

Theory: fire door basics — classification, ratings and functions; this product’s structure, performance and configuration; Class A fire-resistance limit and fire principle; names and functions of all parts. Fire-code requirements — GB 50016 requirements for fire doors; management rules for normally-closed doors; key points of fire inspection and acceptance; hazards and legal liability of misuse. Daily management — patrol content and frequency; identification and reporting of common hazards; prohibitions and precautions; fire-time handling process.

Hands-on: basic operation — correct opening/closing; fire lock use (unlock/lock inside and out, dead bolt); top/bottom bolt release and fixing; switching between half-open and full-open of the large double-leaf door. Daily inspection — appearance (deformation, damage, rust); sealing (seal detachment, aging, gap uniformity); hardware (hinges, locks, closers, sequencer loose or damaged); function (smooth operation, automatic closing, correct order). Basic care — surface cleaning and precautions; hinge/lock lubrication and oil types; closer speed adjustment; simple screw tightening. Fault finding — causes and simple adjustment of jamming; closer speed adjustment; simple lock treatment; reseating detached seals; which faults require professional repair.

Emergency: the fire door’s role and operation in a fire; handling when the door cannot open; reporting and temporary measures when the door is damaged or failed; emergency reporting process and contacts.

16.4 Training Methods and Schedule

Methods: on-site theory lecture by technicians with physical demonstration, PPT and manual; operation demonstration of all procedures; hands-on practice by each trainee with guidance and correction; Q&A session; delivery of course materials and manuals for later reference.

Schedule: one working day: 9:00-11:30 theory and physical introduction; afternoon 13:30-15:30 demonstration and hands-on practice; 15:30-16:30 fault cases and Q&A; 16:30-17:00 assessment and documentation handover. Adjustable to the owner’s schedule.

16.5 Assessment and Documentation Delivery

Assessment: practical test — randomly selected trainees complete four core tasks (standard opening/closing, closer speed adjustment, top/bottom bolt operation, daily patrol check), scored against the operation standard for correctness, proficiency and safety; O&M staff additionally complete lock adjustment and seal reset tasks. Theory test — on-site Q&A plus closed-book exam covering fire-code requirements, product structure and fire principle, fault judgment and daily safety management, with multiple-choice, true/false and short-answer items; pass mark 80/100. Retraining — those who fail receive one-on-one coaching on weak points and a second test until all pass; results are delivered to the owner’s management for staff-capability records.

Documentation delivered: the *Class A Steel Fire Door Use and Maintenance Manual* (parameters, structure, operation, tiered care, fault-finding, safety notes); the full training PPT, test papers and answers for internal retraining; the compliance documentation set (3C certificate, type test report, certificate of conformity, S-mark query instructions) for management and fire inspection; and a dedicated after-sales contact card with the 7×24 hotline, project contact, response times, reporting process and maintenance scope.

16. Training Plan

16.1 Training Objectives and Audience

Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.

Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.

16.2 Tiered Training Content System

Level 1: Basic operation training (1 day)

– Basic principles: system concepts, structure composition, performance indicators;

– Daily operation standards: correct operation of equipment, control and safety systems;

– Daily inspection contents: daily/weekly/monthly check items;

– Safety precautions: usage prohibitions and emergency handling procedures.

Level 2: Maintenance training (1 day)

– Detailed structure of each subsystem and working principles;

– Daily maintenance methods: cleaning, fastening checks, routine care;

– Common fault identification and simple handling;

– Emergency handling procedures for power failure, fire and equipment faults.

Level 3: Advanced management training (as needed)

– Performance influencing factors and how to avoid degradation;

– Upgrade and expansion knowledge and specification requirements;

– Relevant national standards interpretation.

16.3 Training Methods and Schedule

– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;

– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.

16.4 Training Assessment and Documentation Delivery

– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;

– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.

17. Anonymous Typical Project Scenarios

All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.

17.1 Large Intelligent Manufacturing Industrial Park Fire Door Project

Project overview. A national-level intelligent manufacturing industrial park in the Pearl River Delta region, with a total floor area of about 320,000 m², covering heavy production workshops, R&D office buildings, intelligent warehousing and logistics zones and supporting living areas. The fire classification is Level 1, requiring fire separation products of different ratings at compartment walls, large equipment rooms, evacuation routes and pipe shafts. Large Class A steel fire doors were mainly applied at workshop main passages and heavy equipment entrances, with a maximum single-door size of 3000 mm x 3000 mm — closely matching this solution’s product specification and application scenario.

Implementation. The company provided closed-loop service from detailed design, customized production and batch installation to fire acceptance support. For the industry pain point of large leaves sagging and deforming over time, the product used a reinforced C-keel grid frame, thickened hinge reinforcement plates, 3 heavy-duty stainless fire hinges per leaf, 120 kg/m³ high-density fire rock wool filling to guarantee stable Class A performance, and hydraulic cushioning closers with roller sequencers for correct closing order and tight sealing.

The project advanced in three phases with more than 1,200 fire doors supplied in total. Production and installation closely matched the overall construction nodes, coordinating with civil, decoration and fire contractors in cross-operation without a single schedule delay.

Results. The project passed fire acceptance and has operated stably for 3 years. All fire doors run well with no leaf sagging or deformation, no hardware failure and no sealing degradation; daily opening/closing is smooth, automatic closing is stable and the doors remain normally closed; multiple routine fire inspections and special audits passed smoothly with complete documentation and compliant performance, earning recognition from the owner, supervision and fire authorities.

17.2 Urban Core Business Complex Fire Separation Project

Project overview. A large commercial complex in the central business district of a city, with a total floor area of about 180,000 m², combining premium retail, themed dining, entertainment and Class-A offices with daily traffic exceeding 30,000 people — a typical high-density, high-risk venue. Fire doors were configured by rating at evacuation stairwells, compartment walls, kitchen back-of-house, equipment rooms and refuge walkways; large Class A double-leaf doors were mainly used at main passage compartments, flagship store entrances and firefighting access routes.

Implementation. To meet the dual requirements of aesthetics and durability in commercial venues, multiple customizations were made: custom-color electrostatic powder coating matching the mall decoration; all exposed hardware upgraded to brushed 304 stainless steel for both durability and visual quality; and, given the high opening frequency, heavy-duty hydraulic closers and reinforced bearing hinges with opening/closing life improved by more than 40% over standard products.

Considering the mall’s leasing and operation rhythm, a zoned, staggered installation mode was adopted — night work with daytime product protection — minimizing impact on tenant fit-out and operation, with zero safety incidents and zero tenant complaints throughout.

Results. In 4 years of operation, all fire doors have withstood high-frequency use with a failure rate far below the industry average; closers provide moderate force and smooth automatic closing without slamming, maintaining the normally-closed requirement without hindering customers; the intumescent seals remain effective with compliant smoke-blocking performance; the good sealing also provides sound insulation, reducing public-area noise impact on shops and improving the overall environment.

17.3 Tier III Data Center Dedicated Fire Door Project

Project overview. A regional computing data center built to Tier III standards with 2,000+ racks, hosting government cloud, enterprise IDC and internet computing services — critical information infrastructure. Fire separation requirements are extremely strict: the main computer hall, high-voltage distribution room, UPS room, battery room and fire control room all require Class A fire doors, while also meeting the special environment requirements of the data center — dust control, thermal insulation, anti-static and pest/rodent prevention.

Implementation. Multiple special optimizations were applied to the standard product for the data center scenario: the leaf-to-frame fit was upgraded to a double intumescent seal structure and the leaf bottom fitted with an automatic drop-down smoke stop, greatly improving air tightness and dust control; hydrophobic fire rock wool was used inside, providing both fire performance and thermal insulation to reduce cooling loss; all hardware used fire-rated, anti-static materials matching the overall ESD protection system.

In coordination with the intelligent fire system, the fire doors were adapted to the access control and fire linkage system, achieving daily access-control management and automatic release-and-close on fire alarm, fully compliant with data center fire codes.

Results. In 2 years of operation, all fire doors perform stably with excellent sealing, effectively blocking heat transfer at door openings — measured cooling loss reduction of about 15%, indirectly improving chiller efficiency; the fire linkage works correctly, responding accurately in multiple fire drills with automatic closing; documentation is complete and consistent, passing the Class-3 classified-protection assessment and annual fire inspections, meeting the high-grade O&M requirements of the data center.

18. SEO Optimization Section

All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.

18.1 Keyword System

– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;

– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;

– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;

– Brand keywords: KITOZER, Guangzhou Lain.

18.2 SEO Tag System

– Title tag: the article title — Guangzhou Lain KITOZER;

– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;

– H1 tag: the article title;

– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.

18.3 Internal Link Anchor Text

– Core anchor text: technical design solution, system construction;

– Long-tail anchor text: configuration list, technical parameters, construction plan;

– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.

19. Official Contact Information

– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Official Website: https://gdlain.com

– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)

– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.

Shopping Cart