Table of Contents
ToggleProduct Overview
The KITOZER ring main unit is a compact SF6 gas insulated load break switch and fuse combination unit rated 12kV for secondary distribution networks. The RM6 integrates load break switches, fuse protected transformer feeders, and optional circuit breaker modules in a sealed stainless steel gas tank. KITOZER supplies the unit for ring main networks in urban grids, compact substations, and box type transformers. The gas sealed tank eliminates external environmental influence and provides decades of maintenance free service.
Technical Specifications
Rated voltage 12kV, rated frequency 50Hz, rated current 630A. Short time withstand 20kA for 1 second, peak 50kA. Load break switch breaking current 630A, cable fault making 20kA. Fuse combination unit for transformer up to 1250kVA with high voltage current limiting fuses. Gas tank stainless steel filled with SF6 at 0.4 bar, IP67. Operation by spring mechanism, manual or motorized. Earthing switch with make capacity 20kA. Panel width 350mm per module, depth 900mm, height 1600mm. Standards IEC 62271-200, IEC 60420, GB 3906, CE.
Application Scenarios
RM6 ring main units are used in urban ring networks, commercial building incoming switchgear, box type substations, wind and solar farm collector switches, and tunnel power distribution. The small footprint suits underground cable vaults and outdoor kiosks where conventional air insulated switchgear would be too large.
The sealed SF6 gas tank means the RM6 is immune to dust, humidity, and salt fog, making it suitable for outdoor kiosks, underground cable vaults, and coastal urban networks. The modular design allows combinations of switch, fuse, and breaker modules in one line, so a 3 module RM6 can include two loop switches and one transformer fuse feeder. The motorized option allows remote opening and closing from the distribution SCADA, supporting smart grid automation.
The RM6 can also be used as a 10kV feeder for small solar and wind farms, where the sealed gas tank withstands outdoor desert conditions. The fuse combination unit protects transformers up to 1250kVA with fast backup protection.
Advantages and Features
SF6 sealed tank is immune to dust, humidity, and salt fog. The modular design allows combinations of switch, fuse, and breaker modules in one line. KITOZER offers motorized operation for remote SCADA control, fault passage indicators, and cable test isolating terminals. The small footprint saves switchroom space. Lifetime maintenance is limited to mechanical linkage lubrication and gas pressure gauge reading.
Installation and Maintenance
Mount on a wall or floor in a well ventilated location. Connect 12kV XLPE cables with proper lugs and stress cones. Check the gas pressure gauge pointer is in the green zone before energizing. Annual maintenance includes visual gas pressure check, earthing switch operation, and cable termination torque. KITOZER recommends a 10 year inspection of the spring mechanism. Do not refill SF6 gas on site; return to factory if pressure drops.
Construction and Quality Assurance
The RM6 gas tank is welded from 3mm stainless steel and hermetically sealed. The SF6 gas is filled at the factory to 0.4 bar and the tank is leak tested. The spring mechanism is manually or motor operated. The front cover is bolted and sealed. Every unit passes a power frequency withstand test and a gas pressure leak check. KITOZER provides a type test certificate. The sealed design means no routine maintenance is required for 20 years, other than reading the gas pressure gauge.
Packaging and After Sales
Modules are packed in plywood cases. KITOZER provides installation and commissioning support. The 2 year warranty covers switch mechanism and gas tank. Spare load break switches, fuses, and motor operators are stocked. For urban utilities, KITOZER offers a remote motorized operation option for unmanned ring main units.
KITOZER can configure the RM6 as switch switch, switch fuse, switch breaker, or breaker breaker combinations. The motorized operator allows remote control from the distribution SCADA, supporting smart grid automation and fault location. The fault passage indicator on each module shows the direction of fault current, speeding up restoration. The 350mm width per module means a 4 module RM6 line fits in a 1400mm wide kiosk, ideal for urban footprints.
The 2 year warranty covers switch mechanism and gas tank. For urban utilities, KITOZER offers a 5 year extended warranty and a remote monitoring option for unmanned RMU sites.
The RM6 is also used as a 10kV feeder for small solar and wind farms. The fuse combination unit protects transformers up to 1250kVA. The sealed gas tank requires no SF6 refill for 20 years.
KITOZER provides complete documentation, type test certificate, and commissioning support. The sealed gas tank requires no maintenance for 20 years.
Price
From $1,680/module. Contact +86 13922289957 for RM6 quote.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com