KITOZER Wall Mount Air Conditioner 1.5kW Server Room

Product Overview

The KITOZER wall mount air conditioner 1.5kW is a precision cooling unit for small server rooms, network closets, and edge computing cabinets. Unlike commercial split systems that cycle on and off, this unit maintains a stable 24 degrees and 50 percent humidity continuously, which is essential for server reliability. The unit includes a built in humidistat, remote alarm contacts, and a rotary compressor that runs efficiently even at 45 degrees ambient.

Technical Specifications

Cooling capacity: 1.5 kW. Input voltage: 230 V single phase, 50 or 60 Hz. Power consumption: 500 W. EER 3.0. Temperature setpoint 18 to 30 degrees adjustable. Humidity control 40 to 60 percent. Compressor: rotary, inverter. Refrigerant: R410A. Noise level 45 dB(A). Remote alarm: dry contact for high temperature and compressor fault. Weight 25 kg indoor, 30 kg outdoor. Standards CE, KITOZER 3 year warranty.

Application Scenarios

The 1.5 kW wall mount unit is used in small server rooms up to 10 m2, network closets, and edge computing cabinets. It is also specified at retail back offices, hospital clinics, and factory automation rooms that house switches and routers. The compact indoor unit fits above a door, which saves floor space in small rooms.

Advantages and Features

The inverter compressor adjusts cooling capacity continuously, which avoids temperature swings that occur with on off commercial units. The built in humidistat prevents condensation on server hardware. The remote alarm contact integrates with the building management system, alerting the operator before overheating causes downtime. The unit can be monitored via a network card for temperature and compressor status. The rotary compressor has a 50,000 hour design life.

Installation and Maintenance

Mount the indoor unit 2 m above the floor on an exterior wall, and place the outdoor unit in a shaded well ventilated space. Run the refrigerant pipes and drain hose between the units. Connect the 230 V supply and the remote alarm contact to the building management system. Commissioning includes verifying temperature and humidity setpoints. Annual maintenance includes cleaning the filters, checking refrigerant pressure, and inspecting the condensate drain.