Toggle1. Cover / Document Information
– Document Title: Classified Storage Media Intelligent Custody Cabinet Technical Design Solution
– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Date: August 2026
– Version: V1.0
– Project Type: Technical design solution for Classified Storage Media Intelligent Custody Cabinet
2. Table of Contents Structure
1. Company Introduction
2. Project Overview
3. User Requirement Analysis
4. Overall Design Description
5. Detailed System Design and Product Technical Parameters
6. Project Quotation and Configuration List
7. Core Solution Advantages
8. Technical Q&A
9. Construction Schedule Plan
10. Construction Organization Plan
11. After-Sales Service System
12. Operation and Maintenance Training Plan
13. Typical Project Cases
14. SEO Optimization System and Website Backend Configuration
15. Contact Information
3. Company Introduction
3.1 Company Development Overview
Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.
After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.
3.2 Core Business System
The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:
– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;
– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;
– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;
– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.
3.3 Brand and Qualification Honors
The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.
3.4 Core Competitive Advantages
1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;
2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;
3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;
4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.
4. Project Background and Objectives
4.1 Project Background
With the deepening of informatization, classified information increasingly relies on removable storage media — U-disks, mobile hard drives, classified optical discs, memory cards and tapes have become essential carriers for classified units’ daily work. Meanwhile, classified storage-medium management has become a focus and difficulty of confidentiality work: any management loophole can easily cause classified information leakage and serious threats to state secrets.
The National Administration of State Secrets Protection has issued multiple regulations and technical standards with mandatory requirements for the full-lifecycle management of classified storage media. BMB54-2020 “Security and Confidentiality Products — Technical Requirements for Security and Confidentiality of Security Cabinets” provides detailed technical specifications for physical protection, identity authentication, log auditing and security control of classified storage equipment — the core compliance basis for classified units purchasing and using security cabinets.
Traditional classified medium management (“steel cabinet + manual registration”) can no longer meet current refined, intelligent and compliant management needs — low registration efficiency, large human error, difficult traceability and inadequate supervision. Introducing intelligent classified storage-medium security cabinets — using RFID automatic identification, IoT and national-secret encryption to achieve full-process automatic control and ledger tracing — has become the inevitable choice for classified units to improve management and meet compliance acceptance.
4.2 Industry Status
Domestic classified units’ medium management varies, roughly in three stages: rough management (ordinary steel cabinets, no or handwritten ledgers — chaotic, extreme leakage risk, fully non-compliant); manual ledger (dedicated cabinet and administrator with paper/electronic ledgers — meets basic requirements but inefficient, dependent on administrator responsibility, prone to missed/wrong/backfilled entries and ledger fraud, heavy inventory work, difficult audit tracing); intelligent control (smart security cabinets with RFID — automatic identification, identity-authenticated opening, automatic ledger generation, remote supervision/audit — the mainstream direction). Most grassroots units remain at the manual-ledger stage with management lagging behind technology and standards — compliance risk and safety hazards; growing demand for smart-cabinet upgrades as inspection intensity increases.
4.3 Pain Points of Traditional Manual Management
(1) Low registration efficiency, unavoidable human error: every entry/exit/return requires manual ledger filling — tedious, inefficient, and prone to illegible handwriting, missing/wrong information and forgotten entries.
(2) Insufficient identity control, coarse permissions: mechanical or single-password locks — keys/passwords easily copied or leaked; cannot precisely identify the opener or grant per-person/per-classification/per-medium permissions; prone to unauthorized access and mixed storage, violating the “least privilege” principle.
(3) Time-consuming inventory, undetected discrepancies: manual inventory requires checking each medium number against the ledger — heavy workload, prone to errors; missing media may go undiscovered until inventory, missing the best recovery window.
(4) Non-traceable logs, no audit basis: manual ledgers are easily altered, lost or damaged without tamper-proof audit attributes; on leakage incidents, operation history and responsible persons cannot be accurately traced.
(5) High management cost, unstable quality: requires dedicated staff; results depend heavily on the administrator’s competence and responsibility; supervision departments cannot monitor in real time.
4.4 Overall Objectives
Build a BMB54-2020-compliant classified storage-medium intelligent security cabinet system with “automatic identification, automatic ledger, full-process traceability, safe and controllable”:
Compliance: fully compliant with BMB54-2020, passed authoritative detection/certification — meeting confidentiality qualification and inspection requirements.
Automatic ledger: RFID-based automatic registration of entry/exit/borrow/return — no manual ledger filling; accurate, real-time, complete.
Identity control: multi-factor authentication precisely identifying operators; fine-grained permissions — “dedicated person, dedicated authority, access per authority”, eliminating unauthorized operations.
Full traceability: all operations encrypted and recorded; logs non-deletable and non-tamperable; full-lifecycle traceability for audit accountability.
Intelligent warning: overdue return, illegal opening, violent damage and abnormal removal alarms — timely risk detection and handling.
Efficient O&M: simple operation and maintenance; greatly reduced administrator workload; higher standardization.
4.5 Core Value
(1) Compliance risk avoidance: national-standard design from physical protection, identity authentication and log auditing — passing confidentiality qualification review and routine inspections.
(2) Reduced human leakage risk: technical means reduce manual intervention and management loopholes; real-time status monitoring and abnormal warnings build a technical defense line.
(3) Higher efficiency, lower cost: automatic ledger and inventory free administrators for core confidentiality work; reduced labor cost.
(4) Refined management and supervision: fine-grained permission control and full-dimension log auditing enable real-time remote supervision — shifting from “post-hoc accountability” to “prevention and in-process control”.
4.6 Applicable Scenarios
Party/government confidentiality rooms and confidential rooms at all levels; military-scientific institutions and military classified sites; enterprises with classified information-system integration qualifications; classified departments in finance, energy and transportation; design/survey institutes managing classified drawings; temporary classified medium storage for classified exams and meetings. Media: classified U-disks, mobile hard drives, SSDs, discs, tapes, memory cards, classified laptops and classified phones.
5. User Requirement Analysis
5.1 Core Business Functions
Automatic entry registration: record medium number, name, classification, responsible person and validity; bind RFID labels; on door closure auto-identify all labels and generate entry logs (time, operator, details) without manual entry; batch entry; label validity check preventing duplicates/errors.
Automatic exit/borrow registration: identity authentication opens permitted compartments/zones; on door closure auto-recount and identify departed media, generating borrow/exit records (borrower, time, details); permissions by classification/type/responsible person; approval flow for important media.
Automatic return settlement: on return, auto-identify media, update status to “in place”, settle the borrow record with return time; overdue judgment with warnings to borrower and administrator; identity check preventing wrong or substituted media.
Full-process ledger and audit: all lifecycle operations (entry/exit/borrow/return/inventory/maintenance/scrapping) recorded; encrypted logs — non-deletable, non-tamperable, non-repudiable; multi-dimensional query and statistics with one-click compliant audit report export; retention ≥3 years.
5.2 Compliance Requirements
BMB54-2020: cabinet structural strength and anti-pry performance; lock safety and certification; identity authentication safety; log recording and audit; data storage and transmission security; electromagnetic leakage protection; power-loss protection and reliability; cabinet and lock separately certified by the National Confidentiality Science and Technology Evaluation Center (“cabinet-lock dual certification”) with valid certificates.
National confidentiality regulations: comply with the State Secrets Law, classified information-system integration qualification management measures and national-secret carrier management regulations; “three-powers separation” — system administrator, confidentiality administrator and security auditor independent and mutually restraining.
Cryptographic security: identity authentication, data encryption and log protection using national-secret algorithms (SM4); RFID tag, transmission and storage data all encrypted against theft, tampering and forgery.
5.3 Performance Requirements
Identification: 100% in-cabinet tag recognition accuracy, no missed/misreads; batch recognition ≥50 tags/s; full-cabinet inventory ≤3s after door closure. Authentication: fingerprint ≤0.5s, FRR ≤0.01%, FAR ≤0.0001%; password response ≤1s. Response: lock opening ≤1s after authentication; command execution ≤2s. Storage: ≥100,000 local logs; ≥1,000 fingerprints; ≥10,000 media labels. Reliability: MTBF ≥50,000h; electric lock life ≥100,000 operations. Environment: -10℃~50℃, 20%-90%RH non-condensing.
5.4 Security Protection
Physical: mechanical strength against pry/drill/impact; anti-pry latch and multi-point locking; seams per anti-pry requirements; anti-tip with floor bolts. Identity: multi-factor combination (fingerprint+password, card+password, face+password); lockout and alarm after consecutive failures. Data: national-secret encryption of storage and transmission; power-loss protection (data retained, locks stay closed); local/backend dual sync, offline use without network. Alarm: illegal opening, violent prying, authentication-failure overload, abnormal medium removal, power loss — local audible/visual plus management push.
5.5 Expansion and Integration
Multi-cabinet cascade on one platform; standard interfaces to existing confidentiality management systems, OA and access control; optional face recognition, barcode scanning and video linkage modules; internal layout adjustable for different media sizes.
5.6 O&M and Usability
Simple touch interface; modular design for quick fault location/replacement; visualized platform status; remote upgrade, configuration and troubleshooting.
6. Design Principles and Applicable Standards
6.1 Design Principles
Compliance first: all functions and indicators satisfy mandatory BMB54 requirements — passing confidentiality detection and acceptance without compliance risk. Security paramount: full-dimension protection across physical, identity, data and transmission. Practical and easy: focus on automatic ledger and full traceability; simple intuitive flows. Advancement/maturity balance: mature RFID, national-secret encryption and IoT technology verified by large-scale market use. Expandability/openness: modular, standard interfaces for capacity, function and third-party integration. Economy: optimized configuration with maximum ROI.
6.2 Applicable Standards
State Secrets Law and implementation regulations; BMB54-2020; BMB21-2007 (EM leakage protection products); GA374-2019 (electronic anti-theft locks); GB/T 700-2006 (carbon structural steel); GB/T 9286-1998 (coating cross-cut test); GB 50174-2017 (data center design); GM/T 0028-2014 (crypto-module security); GB/T 28181-2016 (video networking); national-secret carrier management regulations; classified information-system integration qualification measures.
7. System Architecture and Working Principle
7.1 Overall Architecture
Four-layer architecture: physical protection layer — security cabinet, storage shelves, media trays, electric locks (mechanical strength per BMB54, anti-pry structure, certified locks); perception layer — RFID reader/antennas, infrared presence sensors, door magnetic sensors, vibration sensors, identity modules (medium identity, door/body status, personnel identity); control/processing layer — embedded main control unit, local encrypted storage, lock control, power management (domestic embedded OS, cabinet software runs offline; all data locally encrypted); application/management layer — PC ledger platform, mobile management, audit report module (medium/user/permission/log/report/centralized multi-cabinet management, remote O&M).
7.2 Working Principle
Each classified medium gets a unique anti-metal RFID label (number, classification, responsible person; data SM4-encrypted against tampering/forgery). In-cabinet readers with directional antennas form stable RF coverage. On door closure the door magnetic sensor triggers inventory: the reader reads all labels; results are compared with the previous inventory to determine additions, removals and state changes; combined with operator identity and operation records, the system auto-generates corresponding entry/exit/return ledger logs, encrypted to local and backend storage. Managers query real-time status, logs and statistics on the platform.
7.3 Business Logic
Entry: administrator records medium info and binds the label → authenticated door opening → place media → door closure triggers auto inventory → new labels matched to records → entry log (time, operator, details) → status “in stock”. Borrow/exit: user authentication → permission query opens corresponding compartment locks → take media → door closure auto inventory identifies departed media → borrow record (borrower, time, details) → status “borrowed”. Return: authentication → door opens → media returned to original position → door closure inventory identifies returned media → settle borrow record with return time and duration → overdue warning if applicable → status “in stock”. Inventory/audit: auto inventory per door operation, manual inventory on demand; inventory report with account-vs-actual comparison marking anomalies; auditor multi-dimensional log query; Excel/PDF export with anti-counterfeit watermark; audit actions themselves logged.
8. Detailed Technical Design
8.1 Cabinet Body Design
1800±5×900±3×500±3mm; Q235B cold-rolled steel (sides/back/top/bottom ≥1.0mm, door ≥1.2mm, door-frame reinforcement ≥2.0mm, latch reinforcement ≥3.0mm); interlocking mortise-tenon structure with no exposed screws; folded door edges with reinforcement ribs; multi-point anti-pry latches locking all directions; door-frame gap ≤1.5mm, body seams ≤2mm, feeler-gauge insertion ≤25mm per BMB54; floor bolt holes with expansion fixing; six-process electrostatic powder coating (degreasing, pickling, phosphating, passivation, spraying, curing) 60-80μm, adhesion grade 0 (GB/T 9286), hardness ≥2H, impact ≥50kg·cm, salt spray ≥48h; per-shelf load ≥50kg, overall static ≥500kg; IP40; ~85kg; certified per BMB54. Adjustable shelves (20 positions at 50mm pitch, 860×450mm, ≥50kg, deflection ≤1mm, 4 standard dividing 5 layers); ABS V-0 anti-metal trays (300×200×30mm, RFID-transparent base, 10 standard); adjustable feet (0-20mm, ≥200kg each, 4).
8.2 Identity Authentication System
10.1″ industrial touch terminal: 1280×800 capacitive 10-point, ≥50M touches, ≥7H; domestic quad-core ARM ≥1.5GHz, 2GB DDR3, 8GB eMMC; domestic embedded Linux; 2 USB, RJ45, 2 RS232, DC12V; -10℃~60℃; front IP65; embedded on the door. Semiconductor live fingerprint module: 508DPI, 12.8×18.0mm, 256×360; domestic algorithm with liveness detection defeating 2D/silicone/paper fake fingerprints; FRR ≤0.01%, FAR ≤0.0001%; 1:1/1:N ≤0.5s (1,000 templates); ≥1,000 templates; SM4-encrypted non-exportable templates; anti-tamper; ≥1M presses; meets confidentiality authentication requirements. National-secret IC card reader: ISO14443 A/B, SM1 CPU cards, Mifare; 13.56MHz; 0-50mm; ≤100ms; SM1/SM4 security chip, one-card-one-key, anti-collision; RS232/Weigand 26/34; ≥100,000h; supports existing access-control card one-card pass. Anti-peep backlit keypad: 16 keys, ≥1M presses; recessed anti-peep design; adjustable backlight; ≥8-digit complex passwords encrypted; 5 failures → lock ≥5min + alarm; virtual password; DC12V; RS232. Optional dual-lens face module: visible + IR 2MP cameras, 75°/60° FOV; dual-lens liveness, national security level B (defeats photos/videos/3D masks); 0.3-1.2m, ≤1s, FRR ≤0.1%, FAR ≤0.001%; ≥1,000 templates; mask recognition; strong/back/dim light with auto fill; local encrypted storage; RJ45/RS232.
8.3 RFID Sensing and Automatic Ledger System
National-secret UHF RFID reader: 920-925MHz (ISM); ISO/IEC 18000-6C; TX 0-30dBm (1dB steps); sensitivity ≤-85dBm; read distance 0-1.5m; SM4 encryption chip (tag data read/write, transmission, tag authentication against forgery); batch ≥50 tags/s; 100% in-cabinet accuracy; 4 SMA antenna ports, RJ45/RS232/4 GPIO; DC12V ≤500mA; -20℃~60℃; built-in top mount. 4 directional flat antennas: 902-928MHz, 3dBi, circular polarization, 60°×60°, VSWR ≤1.5, 50Ω, SMA female, 200×200×10mm, per-layer ceiling mount with narrow-beam precise coverage preventing inter-layer interference. 100 anti-metal RFID labels: 920-925MHz ISO 18000-6C; domestic chip; EPC 96bit (128 optional), user 512bit, TID 64bit unique non-rewritable; data retention ≥10 years; ≥100,000 writes; password protection, SM4 encrypted data zone; anti-tear (destruction on removal); metal read 0-1m, non-metal 0-2m; 50×20×2.5mm PCB; printable. Door-closure inventory trigger: magnetic sensor (normally open, ≤100ms) + control circuit; open = pause inventory, close = 3s delay auto full inventory with anti-bounce; DC12V; IP65. 20 infrared presence sensors: diffuse reflective, 0-30cm adjustable, ≤10ms, ±1mm, 940nm LED, NPN NO, DC5-24V ≤20mA; per-compartment dual verification with RFID. Local encrypted storage: industrial Flash 16GB (firmware/config, fingerprints/passwords/permissions, logs/inventory, label library); SM4 full-disk encryption; power-loss retention ≥10 years; anti-tamper; ≥20MB/s read / ≥10MB/s write; ≥100,000 logs; bidirectional sync with breakpoint continuation.
8.4 Electric Locks and Alarm System
Main door confidentiality electric lock: nationally certified (GA374-2019, BMB54); electromagnetic anti-theft, power-loss self-locking; 3-point locking (main + upper/lower); stroke ≥15mm; stainless anti-saw/anti-drill latch; technical opening resistance ≥10min, violent resistance ≥30min; double-blade mechanical emergency key; DC12V ≤2A transient, zero holding current (locked on power loss); action ≤0.5s; ≥100,000 electrical/mechanical cycles; -40℃~60℃. 10 compartment electric locks: micro DC solenoid plug locks, power-loss auto-lock, independent control per compartment; DC12V ≤300mA, ≤100ms; stroke ≥8mm; zinc-alloy chrome latch; static pull ≥500N; ≥100,000 cycles. Door magnetic sensor: permanent magnet + reed switch, normally open, DC100V/0.5A/10W, 15-25mm pull-in, IP65; real-time door status for inventory/alarm/lighting linkage. Audible/visual alarm: red LED strobe ~2Hz ≥10m visibility + buzzer ≥80dB (1m), continuous/intermittent; DC12V ≤150mA; IP54; triggers on illegal opening, violent prying, authentication failure, abnormal removal, optional power loss; top-front mount. Anti-pry vibration sensor: piezoelectric, 3D full-direction, multi-level sensitivity, ≤10ms, DC12V ≤20mA, switch output; detects prying/impact → alarm + log. Error-lockout module: 5 consecutive authentication failures → auto lock (default 5min, configurable); all methods disabled during lock; local alarm; event logged non-deletable; independent circuit unbypassable; admin manual reset; fully compliant with BMB54 identity-failure protection.
8.5 Ledger Management Software
Embedded cabinet system (KITOZER-GD-V1.0): domestic embedded Linux; identity authentication, lock control, RFID inventory, local ledger, alarm handling, data sync, touch UI; offline fully functional with local encrypted storage and breakpoint-continued sync; firmware encrypted with startup verification; no open debug ports; U-disk or online upgrade. PC ledger platform (KITOZER-PT-V1.0): C/S; Windows/domestic OS + MySQL/domestic DB; full lifecycle management (entry, borrow with approval, return, scrap with label deregistration, inventory with remote reports and account-vs-actual comparison); user/permission management (roles, per-classification/type/compartment permissions); device management (multi-cabinet centralized, status monitoring, remote config); log audit (full records, multi-dimensional query, statistics, Excel/PDF export with anti-counterfeit watermark); SM4-encrypted transmission/storage; log hash verification; UKey login; all back-office operations logged; ≥100 terminals, ≥10,000 media, ≥10M logs; standard API for confidentiality/OA/access-control integration. Three-powers module: system administrator (config/device/accounts — cannot view audit logs or medium details), confidentiality administrator (medium info, borrow approval, daily management — cannot modify config or audit logs), security auditor (all logs, audit reports, violation checks — no business operations); mutually independent and restraining, least privilege, no multi-role occupancy, all three-powers operations logged, dual-factor login. Audit log/report module: all opening, medium lifecycle, alarm, configuration and login operations recorded (time to second, name, ID, type, object, result, terminal IP); hash-chain encrypted storage — any modification detected; non-deletable/modifiable/overwritable; retention ≥3 years; multi-dimensional query (time/person/medium/type/device), fuzzy/precise, daily/weekly/monthly/yearly statistics, custom templates; Excel/PDF export with anti-counterfeit watermark; export actions logged. Data sync module: cabinet-server bidirectional; real-time + timed full sync; breakpoint continuation without duplication/loss; timestamp-priority conflict handling; offline cache ≥100,000 records encrypted; TCP/IP with optional WiFi/4G; SM4 encryption, VPN support, integrity verification.
8.6 Auxiliary and Compliance Design
Red-black power filter socket: BMB21-2007 compliant; AC220V 10A 2200W; 4 national-standard 5-pole outlets; power-line conducted leakage suppression ≥60dB (150kHz-30MHz), signal-line ≥40dB (150kHz-1GHz); overvoltage/overcurrent/short/lightning protection; flame-retardant ABS; 1.5m lead. Shielded Cat6 patch cord: ANSI/TIA-568-C.2, 24AWG pure copper, foil + braid double shield, LSZH, 250MHz/1000Mbps, ≥30dB shielding attenuation, 100Ω±15%, 30U-gold shielded RJ45. Installation kit: 4× M10×80 304 stainless expansion bolts, magnetic level, 1m 4mm² green-yellow earthing lead, lugs, tape, spare hardware.
9. Recommended Configuration and Preliminary Budget
9.1 Cabinet Body
| No. | Item | Model | Qty |
|---|---|---|---|
| 1 | Main security cabinet | KITOZER-BMG-1809 (1800×900×500mm, 1.2mm door, BMB54) | 1 |
| 2 | Adjustable shelves | KITOZER-GB-01 (1.0mm, 50mm pitch) | 4 |
| 3 | Anti-metal media trays | KITOZER-TP-02 (ABS, RFID-transparent) | 10 |
| 4 | Adjustable feet | KITOZER-DJ-03 (galvanized carbon steel) | 4 |
| 5 | Door anti-pry reinforcement | KITOZER-FQ-04 (multi-point latch, anti-pry edge) | 1 |
9.2 Identity Authentication
| No. | Item | Model | Qty |
|---|---|---|---|
| 1 | 10.1″ industrial touch terminal | KITOZER-CK-101 (capacitive, domestic OS) | 1 |
| 2 | Semiconductor live fingerprint module | KITOZER-ZW-05 (liveness, SM4) | 1 |
| 3 | National-secret IC card reader | KITOZER-KA-06 (ISO14443 A/B, SM1) | 1 |
| 4 | Anti-peep backlit keypad | KITOZER-JP-07 | 1 |
| 5 | Dual-lens face module (optional) | KITOZER-RL-08 (level-B liveness) | 1 |
9.3 RFID Sensing and Ledger
| No. | Item | Model | Qty |
|---|---|---|---|
| 1 | National-secret UHF RFID reader | KITOZER-RFID-01 (920-925MHz, SM4) | 1 |
| 2 | Directional flat antennas | KITOZER-TX-02 (narrow beam, per layer) | 4 |
| 3 | Anti-metal RFID labels | KITOZER-BQ-03 (UHF, anti-tear) | 100 |
| 4 | Door-closure inventory trigger | KITOZER-CF-04 (magnetic linked) | 1 |
| 5 | Infrared presence sensors | KITOZER-HW-05 (20, dual verification) | 20 |
| 6 | Local encrypted storage | KITOZER-CC-06 (16GB industrial Flash) | 1 |
9.4 Electric Locks and Alarm
| No. | Item | Model | Qty |
|---|---|---|---|
| 1 | Main door confidentiality lock | KITOZER-SD-01 (certified, power-loss lock) | 1 |
| 2 | Compartment electric locks | KITOZER-GK-02 (independent control) | 10 |
| 3 | Door magnetic sensor | KITOZER-MC-03 | 1 |
| 4 | Audible/visual alarm | KITOZER-BJ-04 (≥80dB + red strobe) | 1 |
| 5 | Anti-pry vibration sensor | KITOZER-ZD-05 (multi-level) | 1 |
| 6 | Error-lockout module | KITOZER-SD-06 (5 failures → 5min lock) | 1 |
9.5 Ledger Management Software
| No. | Item | Model | Qty |
|---|---|---|---|
| 1 | Embedded cabinet system | KITOZER-GD-V1.0 (domestic, offline) | 1 |
| 2 | PC ledger platform | KITOZER-PT-V1.0 (C/S, three-powers) | 1 |
| 3 | Three-powers module | KITOZER-QX-V1.0 | 1 |
| 4 | Audit log/report module | KITOZER-SJ-V1.0 | 1 |
| 5 | Data sync module | KITOZER-TB-V1.0 (breakpoint continuation) | 1 |
9.6 Auxiliaries and Acceptance Documents
Red-black power filter socket (BMB21, 10A 4-socket) ×1; shielded Cat6 patch cord ×1; cabinet installation kit ×1; BMB54 compliance certification copies ×1 set; O&M manual ×1; certificate and warranty card ×1 set.
9.7 Quotation Summary
Total covers cabinet, authentication, RFID, locks/alarms, software, auxiliaries, transport/installation/commissioning, training/acceptance and 3-year free warranty. Optional: face module, extra labels, 4G module, in-cabinet video, T/H module, multi-cabinet platform license, on-site installation, extended warranty. All prices are indicative and quoted in RMB (CNY) only — no foreign-currency conversion is provided. Warranty: 2 years whole machine (3 years core components — structure, main control, reader), lifetime software upgrades and cost-price maintenance; 7×24 support; Pearl River Delta 4h / province 24h / national 48h on-site.
10. Technical Specifications
10.1 Cabinet Body System
| Item | Specification |
|---|---|
| Main cabinet | 1800±5×900±3×500±3mm; Q235B cold-rolled steel — sides/back/top/bottom ≥1.0mm, door ≥1.2mm, door-frame reinforcement ≥2.0mm, latch reinforcement ≥3.0mm; mortise-tenon interlock, no exposed screws; folded door with reinforcement ribs; multi-point anti-pry latches; door-frame gap ≤1.5mm, body seams ≤2mm, feeler insertion ≤25mm (BMB54); floor bolt fixing; coating 60-80μm (6 processes), adhesion grade 0, hardness ≥2H, impact ≥50kg·cm, salt spray ≥48h; shelf load ≥50kg, total static ≥500kg; IP40; ~85kg; nationally certified per BMB54-2020 |
| Adjustable shelves | Q235B 1.0mm; folded edges; clip brackets at 50mm pitch, 20 positions; 860×450mm; ≥50kg, deflection ≤1mm; 4 standard (5 layers), expandable |
| Anti-metal trays | ABS V-0; RFID-transparent base; edge guard; divisible cells; 300×200×30mm; -20℃~70℃; 10 standard |
| Feet | Galvanized carbon steel; 0-20mm adjustment; ≥200kg each; anti-slip, floor-fixable; 4 |
| Anti-pry structure | Internal door ribs ≤300mm spacing; anti-pry interlock edges; anti-drill plate at latch; concealed hinges; gaps ≤1.5mm |
10.2 Identity Authentication System
| Item | Specification |
|---|---|
| Touch terminal | 10.1″ 1280×800 capacitive 10-point; ≥50M touches; ≥7H; domestic quad-core ARM ≥1.5GHz; 2GB DDR3; 8GB eMMC; domestic embedded Linux; 2 USB, RJ45, 2 RS232, DC12V; -10℃~60℃; front IP65; embedded on door |
| Fingerprint module | Semiconductor capacitive 508DPI, 12.8×18.0mm, 256×360; domestic algorithm with liveness detection (defeats 2D/silicone/paper fakes); FRR ≤0.01%, FAR ≤0.0001%; 1:1/1:N ≤0.5s; ≥1,000 templates; SM4-encrypted non-exportable; anti-tamper; DC3.3V ≤50mA (10μA standby); ≥1M presses; confidentiality-certified |
| IC card reader | ISO14443 A/B; SM1 CPU cards, Mifare; 13.56MHz; 0-50mm; ≤100ms; SM1/SM4 security chip, one-card-one-key, encrypted transmission; anti-collision; RS232/Weigand 26/34; DC5V ≤100mA; ≥100,000h; one-card integration |
| Keypad | 16 keys; ≥1M presses; recessed anti-peep; adjustable backlight; ≥8-digit passwords encrypted; 5 failures → lock ≥5min + alarm; virtual password; DC12V ≤50mA; RS232 |
| Face module (optional) | Visible + IR 2MP dual lens; 75°×60°; level-B liveness (photos/videos/3D masks defeated); 0.3-1.2m; ≤1s; FRR ≤0.1%, FAR ≤0.001%; ≥1,000 templates; mask support; auto fill for strong/back/dim light; local encrypted; RJ45/RS232; DC12V ≤200mA |
10.3 RFID Sensing and Automatic Ledger
| Item | Specification |
|---|---|
| UHF RFID reader | 920-925MHz; ISO/IEC 18000-6C; TX 0-30dBm 1dB steps; ≤-85dBm sensitivity; 0-1.5m; SM4 encryption (data read/write, transmission, tag authentication); ≥50 tags/s; 100% in-cabinet accuracy; 4 SMA ports; RJ45/RS232/4 GPIO; DC12V ≤500mA; -20℃~60℃ |
| Directional antennas | 902-928MHz; 3dBi; circular polarization; 60°×60° beam; VSWR ≤1.5; 50Ω; SMA female; 200×200×10mm; 4 per-layer ceiling mounts, narrow-beam no inter-layer interference |
| Anti-metal labels | 920-925MHz ISO 18000-6C; domestic chip; EPC 96bit (128 opt.), user 512bit, TID 64bit unique; retention ≥10 years; ≥100,000 writes; password + SM4 data zone; anti-tear; metal read 0-1m / non-metal 0-2m; 50×20×2.5mm PCB; printable; 100/cabinet |
| Door-closure trigger | Magnetic sensor normally open ≤100ms; open=pause, close=3s delay auto inventory with anti-bounce; DC12V; IP65 |
| Infrared presence sensors | Diffuse reflective 0-30cm adjustable; ≤10ms; ±1mm; 940nm; NPN NO; DC5-24V ≤20mA; 20 pcs; dual verification with RFID |
| Local encrypted storage | Industrial Flash 16GB; SM4 full-disk; retention ≥10 years; anti-tamper; ≥20MB/s read / ≥10MB/s write; ≥100,000 logs; bidirectional sync with breakpoint continuation |
10.4 Electric Locks and Alarm
| Item | Specification |
|---|---|
| Main door lock | Nationally certified (GA374-2019/BMB54); electromagnetic anti-theft, power-loss self-locking; 3-point (main + 2 secondary); stroke ≥15mm; stainless anti-saw/anti-drill; technical opening ≥10min, violent ≥30min; double-blade emergency key; DC12V ≤2A transient / 0 hold; ≤0.5s; ≥100,000 cycles; -40℃~60℃ |
| Compartment locks | Micro DC solenoid plug locks; power-loss auto-lock; independent control; DC12V ≤300mA; ≤100ms; stroke ≥8mm; zinc-alloy chrome; static pull ≥500N; ≥100,000 cycles; 10 pcs |
| Door magnetic sensor | Magnet + reed, normally open; DC100V/0.5A/10W; pull-in 15-25mm; ≤10ms; IP65 |
| Audible/visual alarm | Red LED strobe ~2Hz ≥10m + buzzer ≥80dB (1m); DC12V ≤150mA; IP54; illegal opening / prying / auth failure / abnormal removal / optional power loss |
| Vibration sensor | Piezoelectric 3D; multi-level sensitivity; ≤10ms; DC12V ≤20mA; switch output |
| Error-lockout module | 5 consecutive failures → lock (default 5min, configurable); all methods disabled; local alarm; event logged non-deletable; independent circuit; admin manual reset; BMB54 compliant |
10.5 Ledger Management Software
| Item | Specification |
|---|---|
| Cabinet system | Domestic embedded Linux; authentication, lock control, RFID inventory, local ledger, alarms, sync, touch UI; fully offline with encrypted local storage and breakpoint sync; firmware encrypted, startup verification, no debug ports; U-disk/online upgrade |
| PC platform | C/S; Windows/domestic OS + MySQL/domestic DB; full lifecycle (entry, borrow+approval, return, scrap+deregistration, inventory with remote reports); user/permissions (classification/type/compartment); multi-cabinet centralized management, status monitoring, remote config; log audit (multi-dimensional, statistics, Excel/PDF with watermark); SM4 encryption, hash verification, UKey login, all operations logged; ≥100 terminals / ≥10,000 media / ≥10M logs; open API |
| Three powers | System admin / confidentiality admin / security auditor — independent, mutually restraining, least privilege, no multi-role; all operations logged; dual-factor login |
| Audit module | Full records (time to second, person, ID, type, object, result, IP); hash-chain storage — tamper detection; non-deletable/modifiable; retention ≥3 years; multi-dimensional query, statistics, custom templates; watermarked export; export logged |
| Sync module | Bidirectional cabinet-server; real-time + timed full sync; breakpoint continuation; timestamp-priority conflict handling; offline cache ≥100,000 records encrypted; TCP/IP, optional WiFi/4G; SM4 + VPN + integrity check |
10.6 Auxiliaries
Red-black power filter socket (BMB21-2007; AC220V 10A 2200W; 4 outlets; power-line suppression ≥60dB 150kHz-30MHz, signal-line ≥40dB 150kHz-1GHz; overvoltage/overcurrent/short/lightning protection); shielded Cat6 patch cord (ANSI/TIA-568-C.2, 24AWG OFC, foil+braid, LSZH, 250MHz, ≥30dB, 100Ω±15%, 30U-gold); installation kit (4× M10×80 304 bolts, level, 1m 4mm² earthing lead, lugs, tape).
11. Key Advantages and Customer Value
11.1 Compliance — Fully BMB54-2020 Conformant
Full-chain national-standard design: cabinet structure, lock safety, identity authentication and log audit all pass authoritative testing; cabinet-lock dual certification complete — direct pass through confidentiality qualification review and routine inspections; three-powers separation, tamper-proof logs and multi-factor authentication implemented at the technical level.
11.2 Automation — Zero-Manual-Intervention Full-Process Ledger
UHF RFID automatic identification replaces manual handwritten ledgers for entry/borrow/return/inventory — door closure auto-inventory, state change auto-recorded; eliminates missed/wrong/backfilled entries and ledger forgery; 100% accurate, real-time, complete.
11.3 Security — Multi-Layer Protection
“Physical + identity + data + alarm” layered defense: thickened steel and anti-pry structure; fingerprint/card/password/face multi-factor with fine-grained permissions; SM4 full encryption with tamper-proof logs; alarms covering illegal opening, violent prying, authentication failure and overdue return — full-dimension classified medium safety.
11.4 Traceability — Full-Lifecycle Audit
Every medium’s entry, circulation, use and scrapping fully recorded — operator, time and content precise; logs encrypted, non-deletable and non-tamperable; multi-dimensional query and one-click compliant audit reports — “everything recorded, every item traceable”.
11.5 Usability — Low Operating Threshold
Touch interface with simple flows; ordinary staff master storage operations without special training; clear classified back-office functions; high automation with minimal daily maintenance — reduced administrator burden and training cost.
11.6 Expandability — Flexible Multi-Scenario Deployment
Modular: capacity grows via trays/shelves; functions extend with face recognition, video linkage and T/H modules; multi-department/multi-floor deployment via cascade and centralized platform; standard API integration with confidentiality/OA systems — protecting IT investment.
11.7 Economy — Cost Reduction and Efficiency Gain
One-time investment with long stable service; automatic ledger and inventory save substantial labor hours; reduced leakage/loss risk avoids major losses — higher ROI than manual management.
11.8 Customization — Matched Storage Needs
Source factory customizes internal layout for U-disks, hard drives, discs, laptops and classified phones; cabinet size, color and functions customizable; free differentiated designs matching site and management needs.
12. Technical Q&A (50+ Items)
12.1 Basics and Compliance
Q1: Is the cabinet BMB54-2020 compliant? Any certification?
A: Yes — designed and produced strictly per BMB54-2020; cabinet and electric lock both certified by the National Confidentiality Science and Technology Evaluation Center with complete test reports and certificates — fully compliant for classified units, passing confidentiality inspections and qualification review.
Q2: Does it support three-powers separation?
A: Yes — built-in three-powers module strictly divides system administrator, confidentiality administrator and security auditor roles with mutually independent, mutually restraining permissions — compliant with classified-system graded protection and confidentiality regulations.
Q3: Are national-secret algorithms used?
A: Yes — tag data, local storage and network transmission all use SM4 national-secret encryption; identity authentication and log protection meet cryptographic application security requirements for confidentiality systems.
Q4: What about electromagnetic leakage?
A: The metal sealed cabinet provides baseline EM protection; the bundled red-black power filter socket (BMB21) suppresses power-line conducted leakage; full-shielded cabinet customization available for the highest grades.
Q5: What are the warranty terms?
A: 2 years whole machine, 3 years core components (structure, main control, reader), lifetime software upgrades, cost-price lifetime maintenance; 7×24 support with 4h/24h/48h on-site (Pearl River Delta/province/nationwide).
12.2 Functions
Q6: How is automatic entry/exit registration achieved?
A: Each medium gets a unique RFID label with identity data; after authenticated opening and media access, door closure triggers a full-cabinet inventory; state changes combined with operator identity auto-generate entry/exit ledger records — no manual entry.
Q7: Will RFID miss or misread?
A: Layered directional antennas with optimized inventory algorithms give 100% accuracy at standard density — no missed/misreads; infrared presence sensors add dual verification against label shedding/damage misjudgment.
Q8: Which authentication methods are supported?
A: Standard: semiconductor live fingerprint, national-secret IC card and anti-peep password — individually or in dual-factor combinations; optional dual-lens face for three-factor in high-classification scenes.
Q9: Can different people open only their own compartments?
A: Yes — independent compartment locks with per-compartment permissions; after authentication only authorized compartments open — full least-privilege compliance.
Q10: Is there overdue-return warning?
A: Yes — set expected return time at borrow; overdue media auto-generate warning records with local prompts, backend messages and optional SMS — preventing medium loss.
Q11: Is batch entry supported?
A: Yes — multi-tag anti-collision reads ≥50 tags/s; dozens of media recognized at once with batch entry records.
Q12: How are important media approved?
A: Configurable approval flow — online approval required before borrowing; permissions auto-sync to the cabinet after approval.
12.3 Installation and O&M
Q13: Is installation complex?
A: No — integral cabinet, floor placement and fixing; only 220V mains and one network cable (fully offline use possible without cable); professional on-site installation and commissioning provided.
Q14: Does it work without network? Data loss?
A: Offline operation is fully supported — authentication, opening, inventory and ledger all run locally with encrypted storage; no loss on power/network failure; auto breakpoint-continued sync on recovery.
Q15: Will the door open on power failure?
A: No — the main lock is power-loss self-locking; locks stay closed on outage; power-loss event logged and synced on recovery; mechanical emergency key for lawful access.
Q16: What daily maintenance is needed?
A: Minimal — keep the cabinet clean and dry; industrial components give MTBF ≥50,000h; periodic inspection and on-site maintenance provided.
Q17: How long do RFID labels last?
A: Passive labels need no power — theoretical life ≥10 years; damaged labels are deregistered and re-bound in the platform easily.
Q18: What environments are supported?
A: -10℃~50℃, 20%-90%RH non-condensing; indoor confidentiality-room environments standard.
12.4 Security and Audit
Q19: Can logs be deleted or tampered with?
A: No — hash-chain encrypted storage links each record to the previous one; any deletion/modification is detected; logs are non-deletable, non-modifiable and non-overwritable once generated.
Q20: How long are logs kept? Can they be exported?
A: ≥100,000 local records; server-side effectively unlimited; retention ≥3 years per national standards; Excel/PDF export with anti-counterfeit watermark and traceability marks.
Q21: What happens after repeated wrong passwords?
A: 5 consecutive failures (any method) → 5-minute lock (configurable) with all methods disabled, audible/visual alarm and a non-deletable audit record — effectively preventing brute force.
Q22: What if someone pries the cabinet?
A: The anti-pry vibration sensor detects impact/prying precisely → immediate local alarm + alarm log to the management platform with time and type.
Q23: Can illegal removal of media be detected?
A: Normal removal requires authenticated opening and is auto-recorded; optional access-control and channel RFID detection (chute reader) trigger alarms for unregistered media removal — full closed-loop control.
Q24: Are audit reports compliant?
A: Yes — watermarked, traceable and exportable per confidentiality audit requirements; audit actions themselves logged.
12.5 Expansion and Integration
Q25: Can more cabinets be added for unified management?
A: Yes — cascade support; new cabinets join the same platform for unified user/medium/log management with centralized data — ideal for multi-department, multi-floor deployment.
Q26: Can existing access-control cards be used?
A: Yes — the IC reader supports standard card protocols for one-card integration; personnel and permissions can sync from the existing access-control system.
Q27: Can OA online borrow approval be integrated?
A: Yes — standard API integration with OA/confidentiality systems; online approval auto-syncs permissions to the cabinet for self-service pickup — a complete online-offline closed loop.
Q28: Can video capture be added?
A: Yes — optional in/out-cabinet video module linked to door-opening events with photo/video capture associated to operation logs.
Q29: What optional modules exist?
A: Face recognition, extra labels, 4G module, in-cabinet video, temperature/humidity module, multi-cabinet platform license, on-site installation, extended warranty.
12.6 Fault Finding
Q30: Fingerprint recognition insensitive?
A: Check finger cleanliness/dryness (no peeling, stains, water); re-enroll with multi-angle pressing; gently wipe the sensor window; if unresolved, contact after-sales.
Q31: No auto inventory after door closure?
A: Check the door is fully closed and the magnetic sensor aligned; verify auto-inventory enabled in settings; restart the device; if unresolved, after-sales checks the sensor and reader connection.
Q32: Management PC cannot connect?
A: Check network cable and same subnet; verify cabinet IP and firewall ports; ping the cabinet IP; offline mode still fully works without backend.
Q33: Label unreadable / wrong medium state?
A: Check label integrity and placement (metal covering); manual inventory retry for transient issues; replace the label (deregister + rebind) if damaged.
Q34: Authentication passes but door won’t open?
A: Check lock power; gently push the door to release latch pressure; verify compartment permission; reboot and retest; mechanical latch adjustment or lock service if needed.
Q35: False audible/visual alarm?
A: Lower vibration sensitivity; realign the magnetic sensor; verify repeated failed authentications; check power stability (UPS recommended); reset on the management end.
Q36: Wrong system time?
A: Calibrate manually after long power-off; enable NTP network time sync; confirm Beijing-time zone; replace internal clock battery via after-sales if depleted.
12.7 Training and Service
Q37: What training is provided?
A: Role-based on-site training at acceptance — system administrators (4 sessions), confidentiality administrators (3), security auditors (2), ordinary users (1), with theory + demonstration + hands-on; certificates after assessment; free retraining.
Q38: What materials are delivered?
A: Operation manual, maintenance manual, fault-finding quick table, label application specification, inspection checklists, courseware, certificates and acceptance documents.
Q39: How fast is after-sales response?
A: 7×24 hotline; general issues answered within 2h; remote resolution within 4h; on-site 24h Pearl River Delta / 48h province / 72h nationwide; emergency plans for core-impacting faults.
Q40: How are spare parts guaranteed?
A: Central spare warehouse in Guangzhou with whole units and core parts; backup-unit rotation keeps business running during repairs; original genuine parts; urgent express same-day available.
12.8 Value and Scenarios
Q41: What is the delivery period?
A: Standard products ship from stock immediately; total project including installation, commissioning, training and acceptance about 14 working days.
Q42: How is acceptance performed?
A: Joint open-box inspection, energization and hardware tests, item-by-item function verification (authentication, auto ledger, alarms, reports), trial run, documentation handover and signed acceptance report.
Q43: How does this compare with manual management?
A: Automatic ledger and inventory cut administrator workload ~70% and inventory time from half a day to minutes at 100% accuracy; full traceability and compliance replace fragile manual ledgers.
Q44: Can it manage different media types?
A: Yes — U-disks, mobile/SSD hard drives, discs, tapes, memory cards, classified laptops and phones; internal layout customizable per media.
Q45: Is data safe if the cabinet is stolen?
A: Anti-pry structure, certified locks, vibration alarm, and full-disk SM4 encryption of local storage (physically unreadable after removal) — multi-layer protection of data and media.
Q46: Why choose the KITOZER/Lain solution?
A: Source factory with 20+ years of confidentiality equipment experience, BMB54 dual certification, full-chain integration (hardware + software + service), localized fast response and complete training/after-sales.
Q47: How are violations detected proactively?
A: Overdue warnings, abnormal-removal checks, authentication-failure lockouts and audit anomaly analysis push events to the platform for in-process intervention — from post-hoc to preventive management.
Q48: What inspection checklists are provided?
A: Daily (appearance, power, door closure, alarms), weekly (data sync, inventory verification, authentication tests, lock tests), monthly (log integrity, permission review, backup verification, earthing), annual (structure, modules, security scan, annual report).
Q49: Can the system be expanded for a whole building?
A: Yes — multi-cabinet cascade with centralized platform, permission and audit management; scales from one cabinet to enterprise-wide classified medium management.
Q50: What makes the ledger trustworthy?
A: Automatic RFID-based generation with zero manual intervention, SM4-encrypted hash-chain storage, non-deletable/modifiable records and watermarked audit exports — technically trustworthy and audit-ready.
13. Construction Schedule
13.1 Stage Division
Total 14 working days in six stages: project start/preparation, site survey and design deepening, cabinet transport and arrival, installation and wiring, system commissioning, trial run/acceptance and training.
13.2 Detailed Schedule
| Stage | Work | Days | Responsible | Deliverable |
|---|---|---|---|---|
| 1. Start/preparation | Contract and requirement confirmation; detailed implementation plan and configuration list; material stocking and QC; team formation and disclosure | 3 | PM | Plan, stocking list |
| 2. Survey/design | Site survey of installation position/environment; dimensions, power and network points; deepened wiring plan; customer confirmation | 2 | Technical lead, field engineer | Survey report, wiring drawing |
| 3. Transport/arrival | Outbound inspection and packaging; logistics; unloading and open-box check; customer confirmation | 1 | Logistics, field engineer | Arrival acceptance form |
| 4. Installation/wiring | Cabinet placement and leveling; floor fixing; power wiring; network wiring and termination; internal hardware assembly | 2 | Installation engineer | Installation completion form |
| 5. Commissioning | Hardware energization; firmware upgrade and parameters; platform deployment and database; user permissions and label binding; full-function integration and optimization | 3 | Commissioning engineer | Commissioning records, test report |
| 6. Trial run/acceptance | Trial run and stability observation; issue resolution and optimization; administrator and user training; formal acceptance and documentation | 3 | PM, training engineer | Training records, acceptance report |
13.3 Key Node Control
Arrival acceptance: joint open-box inspection of model/quantity/appearance/accessories with signature — basis for later acceptance. Energization test: full wiring check before first power-on preventing shorts; per-module hardware function tests. Function acceptance: item-by-item verification per contract list (authentication, auto ledger, alarms, reports) before trial run. Final acceptance: stable trial run, complete documentation, completed training, signed final report and handover.
13.4 Schedule Assurance
Standard products in stock for immediate shipment; customized products priority-scheduled; dedicated project team with fixed engineers; mature solutions with pre-identified risks and contingency; daily progress communication; expedited parallel work when compressing schedule.
14. Construction Organization and Quality/Safety Measures
14.1 Organization
Project-manager responsibility system: PM (1) — overall progress/quality/cost/communication and acceptance; technical lead (1) — scheme deepening, commissioning, technical problems, documentation; installation engineers (2) — cabinet installation, wiring, hardware assembly; commissioning engineer (1) — software deployment, configuration, integration; safety officer (1, part-time) — site safety and civilized construction.
14.2 Pre-Construction Preparation
Technical: team familiarization with drawings and product data; detailed construction plan and work instructions; debugging tools, test software and label printer prepared; site-specific contingency plans. Materials: inventory check of cabinet, parts and auxiliaries; appearance/function inspection; tools (impact drill, level, multimeter, crimpers, strippers); PPE (helmet, insulating gloves, dust mask). Site: installation position confirmed and cleared; power/network points verified; entry procedures and site rules observed; safety disclosure.
14.3 Construction Processes
Positioning: mark cabinet position and cable routes per design — straight and neat per wiring codes. Cabinet placement: position, level with the level, fine-tune feet. Fixing: drill, expansion-bolt the base to the floor, re-check level. Wiring: power and network cables in conduit, tidy, strong/weak separated, firm insulated terminations. Hardware assembly: install RFID antennas, reader, sensors and locks; connect and dress wiring firmly. Energization check: multimeter check for shorts/mis-wiring before power-on; per-module power verification. Single commissioning: test authentication, lock control, RFID recognition and alarms; troubleshoot hardware. Network integration: connect to the platform; test data sync, remote management and report generation; full-system integration. Cleanup: remove debris, dress cables, restore site tidiness.
14.4 Quality Assurance
Objective: 100% one-pass acceptance; hardware per national codes; all functions per design; satisfaction ≥95%. Material control: all materials with certificates — unqualified prohibited. Process control: per-code construction with self-check per process; neat labeled wiring with strong/weak separation; item-by-item commissioning records. Acceptance: per GB 50462, GB/T 50312, BMB54-2020, factory standards and contract requirements.
14.5 Safety and Civilized Construction
Objective: zero accidents, injuries and property loss; strict compliance with customer site rules. System: pre-work safety disclosure; daily safety briefings; safety patrols; code-compliant electricity with leakage protection, no random wiring. Measures: helmets and insulating gloves; harnesses and stable platforms for high work; earthed tools with leakage protection; fire equipment and hot-work approval; multi-person cabinet handling against crushing/pinching. Civilized: neat attire and badges; tidy material stacking without blocking fire lanes; low noise; daily cleanup — work finished, site clean; damage to customer facilities compensated.
15. After-Sales Service
15.1 Warranty Commitment
2-year free whole-machine warranty from final acceptance; 3 years for core components (cabinet structure, main control unit, reader); lifetime free software/platform and firmware upgrades; in-warranty non-human, non-force-majeure faults — free repair, part replacement and on-site service; after warranty — lifetime cost-price maintenance (parts + basic service fee only).
15.2 Response and Service Levels
7×24 hotline: general technical issues answered within 2h; remote resolution within 4h; on-site — Pearl River Delta 24h, province 48h, nationwide 72h; emergency faults trigger the contingency plan with priority resources.
15.3 On-Site Service Standards
Badged tidy engineers observing site rules; service content and duration explained before work; protective measures avoiding secondary damage; full function test after repair; site cleanup and signed service record; 24h follow-up call for satisfaction.
15.4 Spare Parts
Central spare warehouse in Guangzhou with whole units and core parts; backup-unit rotation keeps business running during repairs; original genuine parts; urgent express same-day.
15.5 Lifetime Maintenance and Upgrades
≥1 free annual on-site inspection with cleaning, hazard elimination and inspection report; system upgrades on feature iteration/standard updates keeping compliance current; capacity/function expansion and system integration services; lifetime free technical consultation.
15.6 Complaints and Satisfaction
Dedicated complaint hotline/email with response within 24h and follow-up to resolution; satisfaction follow-up after each service, quarterly overall surveys and annual customer satisfaction survey; feedback drives continuous service improvement.
15.7 Service Network
Headquarters technical center in Guangzhou with dozens of senior engineers (hardware/software/structure); regional service points in multiple cities with resident engineers; certified service engineers with product knowledge and field experience.
16. Training Plan
16.1 Objectives
System administrators master configuration, management, daily maintenance and common fault finding — independent daily management; confidentiality administrators master full-lifecycle medium management, borrow approval, ledger and reports; security auditors master log query, audit analysis and report export; ordinary users master authentication and storage operations; the customer achieves self-operated maintenance.
16.2 Role-Based Content
System administrator (4 sessions): architecture and principles; platform installation/login/settings; user/permission/role/three-powers management; cabinet configuration, parameters, status monitoring and remote management; label entry/binding/deregistration/batch import/export; daily care; common hardware/software fault finding; backup and recovery.
Confidentiality administrator (3 sessions): single/batch entry; borrow approval, exit registration, return settlement; inventory initiation, result review and discrepancy handling; scrap flow and label deregistration; overdue/anomaly warnings; statistics and queries; local cabinet operations.
Security auditor (2 sessions): multi-dimensional log query (operations/alarms); periodic and custom audit reports; Excel/PDF export with anti-counterfeit printing; abnormal behavior analysis and risk screening; confidentiality audit requirements.
Ordinary user (1 session): classified-medium management regulations and discipline; fingerprint/card/password authentication operation; open-and-retrieve/door-closure-inventory flow; abnormal handling (authentication failure, door fault, alarm); prohibited acts and emergency contacts.
16.3 Methods and Schedule
“Theory + demonstration + hands-on” with one-on-one guidance at the project site; ~1 day of role-batched training on acceptance day, flexibly arranged; paper/electronic manuals and courseware delivered.
16.4 Assessment and Acceptance
Theory questioning + practical assessment (independent task completion); all trainees must pass — free retraining until qualified; training confirmation signed by both parties.
16.5 Ongoing Support
Dedicated service group for daily questions; free online refresher or preferential on-site refresher on personnel changes; upgrade training after major feature releases; periodic follow-up with targeted guidance.
16. Training Plan
16.1 Training Objectives and Audience
Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.
Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.
16.2 Tiered Training Content System
Level 1: Basic operation training (1 day)
– Basic principles: system concepts, structure composition, performance indicators;
– Daily operation standards: correct operation of equipment, control and safety systems;
– Daily inspection contents: daily/weekly/monthly check items;
– Safety precautions: usage prohibitions and emergency handling procedures.
Level 2: Maintenance training (1 day)
– Detailed structure of each subsystem and working principles;
– Daily maintenance methods: cleaning, fastening checks, routine care;
– Common fault identification and simple handling;
– Emergency handling procedures for power failure, fire and equipment faults.
Level 3: Advanced management training (as needed)
– Performance influencing factors and how to avoid degradation;
– Upgrade and expansion knowledge and specification requirements;
– Relevant national standards interpretation.
16.3 Training Methods and Schedule
– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;
– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.
16.4 Training Assessment and Documentation Delivery
– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;
– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.
17. Anonymous Typical Project Scenarios
All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.
17.1 Provincial Government Department Classified Medium Intelligent Management Project
Project background. A provincial classified government department managed classified U-disks and mobile hard drives with ordinary security cabinets plus manual ledgers — low registration efficiency, difficult inventory and poor traceability, under pressure ahead of confidentiality qualification re-review.
Implementation. Eight classified storage-medium intelligent security cabinets across departments; a centralized management platform for unified control; fingerprint + password dual-factor authentication with departmental permissions; integration with the existing access-control system for one-card pass; customized audit report templates per the department’s confidentiality audit code.
Results. Full-process automatic registration cut administrator workload 70%; inventory time from half a day to minutes at 100% accuracy; fully traceable and standardized; passed confidentiality qualification re-review with praise; stable with zero faults for over 3 years.
17.2 Military-Scientific Research Institute Confidentiality Room Upgrade Project
Project background. The institute ran multiple classified research projects with numerous high-classification, frequently circulating media; the old management model could not meet refined control requirements, posing leakage risk.
Implementation. Twelve high-classification intelligent cabinets storing top-secret/secret/confidential media separately; fingerprint + face + password three-factor authentication; in-cabinet video with automatic capture on opening; integration with the project management system associating media with projects; a complete full-lifecycle management and audit system.
Results. Physical and permission isolation of different classifications per graded protection; fully monitored and traceable circulation greatly reducing leakage risk; automation improved researcher efficiency; passed the superior confidentiality special inspection and became a regional demonstration project.
17.3 Classified-Qualification Enterprise Data Center Medium Control Project
Project background. A classified information-system integration qualified enterprise’s data center stored large numbers of classified hard drives and tapes with frequent in/out movements; manual management had high error rates and prominent account-vs-actual discrepancies.
Implementation. Six large-capacity intelligent cabinets adapted for hard drives and tapes; RFID + barcode dual identification compatible with the existing asset system; OA integration for online borrow approval; channel removal detection preventing illegal medium removal; full-lifecycle ledger synchronized with the asset system.
Results. Account-vs-actual consistency reached 100%; in/out efficiency tripled with zero errors; digitalized intelligent medium asset management; passed the annual classified-qualification supervision audit.
17.4 District Confidentiality Bureau Batch Deployment Project
Project background. A district confidentiality bureau standardized classified medium management across its jurisdiction by centrally procuring intelligent security cabinets for subordinate streets and commissions.
Implementation. Thirty standard intelligent cabinets in batch; a unified platform letting the bureau remotely supervise usage; standardized configuration and operation flows for unified inspection and assessment; staged installation and training covering all key classified units; unified after-sales system.
Results. Standardized classified medium management across the district; inspection efficiency greatly improved with online verification; unified procurement and maintenance reduced overall cost; recognized and promoted by the superior confidentiality authority.
17.5 Design Institute Classified Drawing Medium Project
Project background. A design institute stored many classified drawings on discs and mobile hard drives — large quantity, frequent borrowing, slow retrieval, untimely returns and high drawing-leakage risk.
Implementation. Hybrid intelligent disc and medium cabinets; media associated with projects and designers for refined management; quick-search locating storage positions in seconds; automatic overdue reminders improving turnover; complete borrow audit records with accountability.
Results. Retrieval time from ~10+ minutes to tens of seconds; overdue return rate down 80% with much higher turnover; fully traceable drawing flows with significantly reduced leakage risk; high designer satisfaction.
17.6 Financial Institution Classified Archive Medium Project
Project background. A financial institution stored large amounts of classified client data and business archives on electronic media requiring long-term secure storage, strictly controlled access and regulatory audit compliance.
Implementation. Large-capacity intelligent cabinets with constant temperature/humidity modules; dual-person dual-lock authentication for important media (two persons authenticated together); detailed operation audit logs meeting financial regulatory requirements; integration with the institution’s identity system for unified accounts; periodic automatic inventory ensuring archive integrity.
Results. Met strict financial security and compliance requirements; standardized intelligent archive management; complete traceable audit data passing regulatory inspections; reduced archive management workload with higher efficiency.
18. SEO Optimization Section
All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.
18.1 Keyword System
– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;
– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;
– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;
– Brand keywords: KITOZER, Guangzhou Lain.
18.2 SEO Tag System
– Title tag: the article title — Guangzhou Lain KITOZER;
– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;
– H1 tag: the article title;
– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.
18.3 Internal Link Anchor Text
– Core anchor text: technical design solution, system construction;
– Long-tail anchor text: configuration list, technical parameters, construction plan;
– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.
19. Official Contact Information
– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Official Website: https://gdlain.com
– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)
– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.