KITOZER
KITOZER

Tunnel Electromechanical Engineering Signal Lights and Monitoring System

Table of Contents

1. Cover / Document Information

– Document Title: Tunnel Electromechanical Engineering Signal Lights and Monitoring System Technical Design Solution

– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Date: August 2026

– Version: V1.0

– Project Type: Technical design solution for Tunnel Electromechanical Engineering Signal Lights and Monitoring System

2. Table of Contents Structure

1. Company Introduction

2. Project Overview

3. User Requirement Analysis

4. Overall Design Description

5. Detailed System Design and Product Technical Parameters

6. Project Quotation and Configuration List

7. Core Solution Advantages

8. Technical Q&A

9. Construction Schedule Plan

10. Construction Organization Plan

11. After-Sales Service System

12. Operation and Maintenance Training Plan

13. Typical Project Cases

14. SEO Optimization System and Website Backend Configuration

15. Contact Information

3. Company Introduction

3.1 Company Development Overview

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.

After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.

3.2 Core Business System

The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:

– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;

– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;

– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;

– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.

3.3 Brand and Qualification Honors

The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.

3.4 Core Competitive Advantages

1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;

2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;

3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;

4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.

4. Project Background and Objectives

4.1 Project Background

Urban tunnels — key nodes of the road network — feature strong enclosure, complex lighting and difficult accident handling; their traffic control and safety-monitoring capability directly affects line efficiency and public safety. A complete signal-control system and HD video surveillance system are the core infrastructure of tunnel electromechanical works for maintaining traffic order, rapidly handling emergencies and achieving visualized operations.

With growing urban traffic, tunnel operations demand higher reliability, environmental adaptability and intelligence. This solution designs an integrated signal and surveillance system covering tunnel entrances/exits, the full interior and outer plazas — meeting daily traffic control, emergency dispatch and security needs.

4.2 Project Scope

Two core systems: traffic signal control — in-tunnel lane indicators, entrance/exit vehicle and pedestrian signals, variable speed-limit signs, signal control hosts, transmission equipment and pipeline auxiliaries — achieving lane-state control, entrance dispatch, speed-limit publishing and remote centralized control; video surveillance — tunnel-dedicated HD cameras, entrance license-plate capture, outer-plaza intelligent PTZs, indoor cameras, plus transmission network, storage/decoding, center display, power and lightning protection — full-area HD coverage, storage, video-wall display and intelligent O&M.

4.3 Objectives

Intelligent control: one-key remote signal-state switching and preplanned automatic control; full-area monitoring with intelligent analysis — higher management efficiency.

Environmental adaptation: all front-end devices suit the tunnel’s humid, dusty, low-light, high-temperature-differential environment with compliant protection ratings and 7×24 stable operation.

High reliability: industrial-grade core devices, redundancy at key nodes, fault self-check and alarms; industry-leading MTBF.

Expandable compatibility: standard protocols and modular architecture with reserved smart-tunnel upgrade and multi-system linkage interfaces.

Compliant acceptance: all devices and designs per national/industry standards, meeting municipal engineering acceptance codes.

5. User Requirement Analysis

5.1 Signal System

Lane control: red-cross/green-arrow lane indicators in both directions with remote pass/close switching for accident and maintenance scenarios; high brightness and penetration for smoke conditions. Entrance control: full-screen vehicle signals at both entrances with flow-restriction commands; pedestrian signals at crossing channels with countdown; high visibility. Variable speed limit: dot-matrix signs at entrance/mid/exit sections publishing speed values in real time per weather, flow and incidents. Centralized control: signal platform and workstations in the center — real-time status, remote manual control, timed preplanned execution; local offline operation without network. Durability: high protection, corrosion/vibration resistance, long service life.

5.2 Surveillance

Full coverage: HD bullets at intervals inside (no blind spots); license-plate capture at entrances; intelligent PTZs at plazas; domes indoors. HD imaging: ultra-wide dynamic and strong-light suppression against headlight glare; color HD at night with even IR. Storage/display: 30+ day storage with adjustable bitrate; LCD video wall with multi-channel decode, splits, roaming, splicing and patrol. Transmission: fiber backbone with industrial switches and ring protection — single-point failure does not affect the system. Intelligence/O&M: motion detection, intrusion and occlusion analysis; online status, fault alarms, remote configuration.

5.3 General

Multi-level lightning protection and unified earthing; UPS for the monitoring center; standard municipal construction practices adapted to tunnel civil structures.

6. Design Principles and Applicable Standards

6.1 Design Principles

Reliability first: industrial-grade devices, redundant key nodes, fault self-check and alarms, offline-capable control. Environmental adaptation: IP65+ front-end devices, wide temperature, salt fog and vibration resistance. Intelligence: preplanned signal control, intelligent video analysis, platform integration. Standardization/expandability: national standards, universal protocols, modular architecture. Safety: complete lightning/earthing, UPS backup, personnel and traffic safety during construction.

6.2 Applicable Standards

GB 14887-2011 (road traffic signals), GB 14886-2016 (signal installation), GB 25280-2016 (traffic signal controllers), GB/T 28181-2016 (video networking), GB 50395 (surveillance engineering design), GB/T 17626.5 (surge), GB 4208 (IP codes), GB/T 2423 (environmental), GB 18802.1 (SPD), GB 50009 (structural loads), GB 50174 (data center), highway tunnel traffic engineering design code, municipal engineering acceptance codes.

7. System Architecture and Working Principle

7.1 Overall Architecture

Signal control system: lane indicators, vehicle/pedestrian signals and variable speed-limit signs at field points → signal area controllers (KITOZER-SC-32, 32 circuits) with IO expansion modules → transmission (RS485/Ethernet/optical) → signal control center workstations with the KITOZER tunnel traffic signal management platform — remote monitoring, control, preplans, alarms and logs.

Surveillance system: tunnel bullets, license-plate capture, plaza PTZs and indoor domes → access switches and fiber transceivers → aggregation switches → core switch → NVR storage + decoding matrix + streaming media server → video wall, console and workstations; power with UPS and multi-level lightning protection.

7.2 Working Principles

Signals: the area controller drives lamp circuits per mode (manual/timed/remote/inductive/preplan); 32 independent circuits with per-circuit monitoring; on communication loss it degrades to local control; multi-controller synchronization ≤10ms supports green-wave coordination. Surveillance: cameras encode H.265 streams over the fiber ring (ERPS <50ms self-healing); NVRs record 30+ days; the matrix decodes to the video wall; the streaming server forwards to clients; intelligent analysis and fault alarms notify operators.

8. Detailed Technical Design

8.1 Signal Devices

Lane indicators: red-cross/green-arrow LED units, Φ300mm per unit, brightness ≥8000cd/m², visible ≥300m, IP65, -40℃~+70℃; remote pass/close switching. Vehicle full-screen signals (KITOZER-JM-400): Φ400mm red/yellow/green, ≥6000/7000cd/m², visible ≥400m (day) / ≥200m (night); dual-color LED countdown (character ≥300mm, 0-99s, visible ≥200m); AC220V±20%, ≤90W per lamp; IP65; -45℃~+80℃; salt spray 500h; ADC12 die-cast housing ≥2.5mm; PC visor ≥3mm (≥92% transmittance, ≥850J/m); EPDM seals; GB 14887-2011 certified with ministry test report. Pedestrian signals (KITOZER-RX-300): Φ300mm dynamic red-standing/green-walking, ≥5000/6000cd/m², visible ≥150m; 2-digit countdown 200mm; AC220V ≤20W; IP65; steel housing 400×800×120mm ~6kg. Vehicle signal cantilever pole: Q235 seamless, 6.5m pole φ219×8mm, 6m arm φ140×6mm; argon-arc welding; galvanizing ≥85μm + powder ≥60μm; flange 400×400×20mm with 4× M30 anchors (cage ≥1200mm); wind ≥12 levels; verticality ≤1‰; life ≥30 years. Pedestrian pole: 3.5m φ114×4mm, flange 250×250×16mm with M20 bolts; ≥10 levels; ≥25 years.

8.2 Variable Speed-Limit Sign (KITOZER-VS-12060)

1200×600mm display; P16 dot matrix red/green dual-color, 3906 points/m²; 0-80km/h numerals plus text/graphics; average brightness ≥8000cd/m² with 16-level auto brightness (ambient sensor, day/night); visible ≥250m day / ≥400m night; ≥120Hz refresh; AC220V±15%, average ≤150W / peak ≤300W; RS485 + TCP/IP control with local keys; multi-period speed preplans with timed auto-switching; pixel-level self-check with remote fault reporting; IP65; -40℃~+70℃; salt spray 500h; aluminum frame ≥2mm anodized + PC diffusion visor + ribbed sheet-metal rear; 1300×700×120mm ~35kg; MTBF ≥50,000h; LED ≥100,000h; mounting bracket — 8# galvanized channel ≥5mm triangular support, ≥100kg, angle adjustable.

8.3 Signal Control and Transmission

Area controller (KITOZER-SC-32): industrial ARM ≥1GHz, ≥512MB RAM, ≥1GB Flash; 32 independent circuits (AC220V/10A each); five modes — manual/timed/remote/inductive/preplan; ≥100 preplans with one-key call and timed/triggered execution; inter-controller sync ≤10ms; green-wave coordination; fault degradation to local control on communication loss; 16 dry inputs; 2 RS232 + 2 RS485 + 2 GE + USB; expansion to 64 outputs; TCP/IP, UDP, Modbus-RTU, GB/T 20999; AC220V±20% ≤50W; external UPS ≥2h; insulation ≥100MΩ, withstand 2000V/1min; power-port surge protection; host IP40 / cabinet IP65; -20℃~+65℃; 19″ 3U 482×300×132mm ~12kg; per-circuit voltage/current monitoring with alarm records; hardware watchdog; ≥10,000 logs; MTBF ≥50,000h; GB 25280-2016. IO module (KITOZER-IO-8): 8 relay outputs AC220V/10A, opto-isolated, per-circuit fuse/overcurrent/short protection; RS485 Modbus-RTU; DIN rail. Industrial access switch (KITOZER-IS-8T2S): 8 FE + 2 GE SFP; ≥5.6Gbps; VLAN/QoS/mirror/aggregation/ERPS (<50ms); Web/CLI/SNMP; DC12-48V dual power; IP40 fanless; -40℃~+75℃; MTBF ≥100,000h. Workstation: i5-12400, 16GB, 512GB NVMe + 2TB, 2GB GPU, 23.8″ IPS, Win10 Pro.

Management platform (KITOZER tunnel signal platform V2.0): B/S + C/S hybrid; electronic-map device status; per-lamp/area/region remote control with one-key switching and graded permissions; visual preplan configuration with timed/event-triggered execution; real-time popup/sound/SMS alarms with query/traceability; full operation/status/alarm logs with Excel export; statistics reports; multi-level users (admin/operator/visitor) with full audit; video/tunnel-platform integration; ≥100 concurrent clients; Windows Server 2016+/MySQL 5.7+; permanent license with free upgrades.

8.4 Surveillance Front-End

Tunnel bullet (KITOZER-CAM-T400): 1/1.8″ star-level CMOS 4MP 2560×1440; color 0.001Lux / B/W 0.0001Lux / 0Lux IR; 120dB WDR against headlight glare; S/N ≥55dB; ICR day/night; 3D DNR; 8mm lens (4/6/12 optional) F1.2, H-FOV 38.5°; array IR ≥50m with smart IR; H.265+/H.265/H.264/MJPEG triple streams; motion detection, occlusion, crossing, intrusion, vehicle detection, people counting; 1 alarm in/out; audio in/out; Micro SD 256GB; DC12V/PoE, ≤8W (≤12W IR); power+network 2-in-1 SPD ±6kV; IP67; -40℃~+60℃; aluminum die-cast; MTBF ≥100,000h; GB/T 28181, GB 50395 with third-party report. License-plate capture (KITOZER-CAM-LP500): 1/1.8″ global-shutter CMOS 5MP 2592×1944@25fps; color 0.01Lux / B/W 0.001Lux; digital strong-light suppression; 12mm F1.4 lens; built-in strobe sync ≥30m; plate types — blue/yellow/NEV/police/coach; accuracy ≥99% day / ≥97% night; ≤200ms; vehicle/brand/color recognition; GE + RS485 + alarm/audio; GB/T 28181/ONVIF; AC24V/DC12V ≤15W; IP66; -30℃~+70℃; aluminum housing ~2kg. Intelligent PTZ (KITOZER-PTZ-400): 1/2.8″ 4MP 2560×1440; 23× optical + 16× digital; 360° continuous pan, -15°~90° tilt; 256 presets ≤0.1°; 8 cruises ×16 points; IR ≥150m with zoom-sync smart IR; 120dB WDR; motion/intrusion/crossing/gathering detection, auto tracking, face recognition; H.265+ triple streams; GE + audio + alarm; SD 256GB; AC24V ≤30W; power+network+video 3-in-1 SPD; IP66, IK10; -40℃~+65℃; ~4kg. Dome (KITOZER-CAM-D200): 2MP 1080P, 2.8mm 90°, 30m IR, DC12V/PoE ≤5W, IP40, ceiling.

8.5 Transmission and Storage

Fiber transceivers (KITOZER-FE-100): 10/100M + 100M SC single-mode single-fiber 20km (1310/1550nm); DC5V ≤5W; IP40; -40℃~+75℃. Aggregation switch (KITOZER-IS-24T4S): 24 GE + 4 GE SFP; ≥56Gbps/42Mpps; 4K VLANs, aggregation, mirror, QoS, storm suppression; ERPS <50ms; static routing/RIP; Web/CLI/SNMP/RMON; dual DC12-48V; ±4kV/±2kV surge; DIN rail; -40℃~+75℃; MTBF ≥200,000h. Core switch (KITOZER-CS-48T8S): 48 GE + 8×10G SFP+; ≥336Gbps/132Mpps; 4K VLANs; static/RIP/OSPF/BGP; stacking (9 units); ACL/port security/ARP/DOS protection; dual AC220V; 1U. Armored fiber (GYTA-8B1): 8-core G.652D; ≤0.36/0.22dB/km; layered structure with armored steel tape, PE sheath; tensile 600/1500N; crush 300/1000N/100mm; life ≥25 years. Cat6 UTP: 23AWG OFC, 250MHz/1000Mbps, 100±15Ω. Termination box: 8-port 1U rack with SC couplers and pigtails.

NVR (KITOZER-NVR-32): 32 channels; 4K/8MP-1080P; 4×4K or 16×1080P decode; 4 SATA bays (20TB each); HDMI 4K + VGA; timed/motion/alarm/manual recording; 1/4/9/16 playback with fast/slow/reverse/frame; USB/network/disk backup; 2 GE (multi-address/fault-tolerance/load balancing); 4 USB2.0 + USB3.0 + RS485 + audio + 16 alarm in/4 out; ONVIF/GB 28181/RTSP; ≤20W; 1.5U. Surveillance drive: 8TB SATA3 7200rpm 256MB; MTBF ≥1,800,000h; ≥180TB/year; error-recovery control and vibration compensation. Decoding matrix (KITOZER-DM-16): 16×4K or 32×1080P decode; 16 HDMI outputs; 128-channel input; split/window/roaming/splicing/PIP; patrol; 16-screen splicing; H.265/H.264, ONVIF/GB 28181; WEB/client/3D-keyboard control; 2 GE; AC220V ≤150W; 4U. Streaming server (KITOZER-SVR-M1): 2× Xeon E5-2620V4, 32GB ECC (512GB max), 2TB system + 4×3.5″ bays, 4 GE with aggregation, 550W redundant PSU, 2U; ≥100-stream forwarding; unified device management; multi-level permissions; logs; cascading; Win Server 2019; MTBF ≥100,000h.

8.6 Center Display and Control

55″ splicing unit (KITOZER-LCD-55): 1920×1080, 3.5mm bezel, 500cd/m², 4000:1, 178°, 8ms, 16.7M colors, ≥60,000h; HDMI/DVI/VGA/BNC/USB, RS232 cascade; arbitrary row×column; 7×24; ≤180W. Wall bracket: aluminum + cold-rolled steel, 3×3, six-way ±1mm adjustment, ≥80kg/screen, ≤150mm off-wall. Triple console: 1800×900×750mm, fireproof top, steel 1.2mm, keyboard trays, device bays, cable ducts. Workstation: i7-12700, 32GB, 1TB NVMe + 4TB, 4GB GPU, 27″ 2K IPS. 3D control keyboard (KITOZER-KEY-3D): PTZ/matrix/wall control, 3D optical joystick, 2.8″ LCD, RS485/RS232/GE, Pelco-P/D/Visca, presets/cruises/screen switching.

8.7 Power, Lightning and Earthing

2-in-1 SPD: power + network; In 10kA / Imax 20kA; signal Up ≤15V, power ≤1500V; RJ45 1000Mbps; IP65; ≤1ns; failure window. Room level-2 SPD: three-phase 380V, In 40kA / Imax 80kA, common+differential, ≤25ns, DIN rail, remote alarm, GB 18802.1. UPS (KITOZER-UPS-10K): 10kVA/8kW online double conversion; three-phase 304-456V in; 220V ±1% out; 50Hz±0.1%; lead-acid pack DC192V; 2h full-load backup; 0ms transfer; protections; LCD; RS232/SNMP; battery cabinet included; ≤55dB. Distribution box: 600×800×200mm 1.5mm steel; main breaker, 10 branch circuits with independent switches, leakage protection, SPD, terminals. Earthing busbar: T2 copper 40×4mm tin-plated, 1m lengths with insulators — equipotential for the room.

9. Recommended Configuration and Preliminary Budget

9.1 Signal System

Lane indicators (red-cross/green-arrow) per lane set; vehicle full-screen signals with countdown (KITOZER-JM-400) ×8 groups; pedestrian signals (KITOZER-RX-300) ×sets; 6.5m cantilever poles and 3.5m pedestrian poles; variable speed-limit signs (KITOZER-VS-12060) per section with brackets; signal area controllers (KITOZER-SC-32) with IO modules; industrial access switches; signal workstations; management platform V2.0; RVV 4×1.5 control cable; Φ25 galvanized conduit; IP65 junction boxes; installation kits.

9.2 Surveillance System

Tunnel bullets (KITOZER-CAM-T400); license-plate capture (KITOZER-CAM-LP500); plaza PTZs (KITOZER-PTZ-400); indoor domes (KITOZER-CAM-D200); 304 side-wall brackets; 4m camera poles; IP65 outdoor boxes; fiber transceivers; aggregation and core switches; GYTA-8B1 armored fiber; Cat6; termination boxes; 32-channel NVRs with 8TB drives; decoding matrix; streaming server; 3×3 55″ video wall with bracket; triple console; monitoring workstation; 3D keyboard; 2-in-1 SPDs; room SPD; 10kVA UPS with battery cabinet; distribution box; earthing busbar; auxiliaries.

9.3 Engineering and Services

Cable laying (7 days), foundations and poles (5 days), front-end installation (6 days), center installation (4 days), commissioning (5 days), acceptance/training (2 days) — total ~32 days; construction organization, quality/safety measures, after-sales and training included.

9.4 Quotation Notes

Final quotation per confirmed quantities and configuration, tax-inclusive. All prices are indicative and quoted in RMB (CNY) only — no foreign-currency conversion is provided. Warranty: 2 years whole system, quarterly inspections, 7×24 support, 2h response / 4h urban on-site; lifetime software upgrades and preferential hardware.

10. Technical Specifications

10.1 Signal Control System

Item Specification
Vehicle full-screen signal (KITOZER-JM-400) Φ400mm red/yellow/green; ≥6000/7000cd/m²; visible ≥400m day / ≥200m night; dual-color countdown ≥300mm, 0-99s, ≥200m; AC220V±20% ≤90W; IP65; -45℃~+80℃; salt spray 500h; ADC12 housing ≥2.5mm; PC visor ≥3mm ≥92% ≥850J/m; EPDM seals; GB 14887-2011 + ministry report; MTBF ≥100,000h; LED ≥100,000h; life ≥15 years
Pedestrian signal (KITOZER-RX-300) Φ300mm red-standing/green-walking dynamic; ≥5000/6000cd/m²; ≥150m; 200mm countdown; AC220V ≤20W; IP65; steel 400×800×120mm ~6kg; GB 14887-2011
Vehicle cantilever pole Q235 6.5m φ219×8mm + 6m arm φ140×6mm; argon-arc; galv ≥85μm + powder ≥60μm; flange 400×400×20mm + 4×M30 (cage ≥1200mm); wind ≥12; verticality ≤1‰; ≥30 years
Pedestrian pole 3.5m φ114×4mm; galv ≥65μm + powder ≥50μm; flange 250×250×16mm + M20; wind ≥10; ≥25 years
Variable speed sign (KITOZER-VS-12060) 1200×600mm P16 red/green dual-color; ≥8000cd/m² with 16-level auto brightness; visible ≥250m day / ≥400m night; ≥120Hz; 0-80km/h + text/graphics; AC220V avg ≤150W / peak ≤300W; RS485 + TCP/IP; multi-period preplans; pixel self-check; IP65; -40℃~+70℃; salt spray 500h; 1300×700×120mm ~35kg; MTBF ≥50,000h; LED ≥100,000h; 8# galv bracket ≥100kg
Area controller (KITOZER-SC-32) ARM ≥1GHz; 32 circuits AC220V/10A; 5 modes; ≥100 preplans; sync ≤10ms; green wave; offline degradation; 16 dry in; 2RS232+2RS485+2GE+USB; expand 64 out; TCP/IP/UDP/Modbus/GB 20999; ≤50W; UPS ≥2h; insulation ≥100MΩ/2000V; per-circuit monitoring; watchdog; ≥10,000 logs; host IP40/cabinet IP65; -20℃~+65℃; 3U; MTBF ≥50,000h; GB 25280-2016
IO module (KITOZER-IO-8) 8 relay AC220V/10A; opto-isolated; per-circuit fuse/overcurrent/short; RS485 Modbus-RTU; DIN rail
Access switch (KITOZER-IS-8T2S) 8FE + 2GE SFP; ≥5.6Gbps; VLAN/QoS/mirror/aggregation/ERPS <50ms; Web/CLI/SNMP; DC12-48V dual; IP40 fanless; -40℃~+75℃; MTBF ≥100,000h
Workstation i5-12400 6C12T; 16GB; 512GB NVMe + 2TB; 2GB GPU; 23.8″ IPS; Win10 Pro
Management platform V2.0 B/S+C/S; electronic map; remote per-lamp control; preplans; alarms (popup/sound/SMS); logs/Excel; statistics; multi-level users; video/platform integration; ≥100 clients; permanent license

10.2 Surveillance System

Item Specification
Tunnel bullet (KITOZER-CAM-T400) 1/1.8″ star CMOS 4MP; 0.001/0.0001/0Lux; 120dB WDR; S/N ≥55dB; ICR; 8mm F1.2 (4/6/12 opt.); IR ≥50m smart; H.265+ triple; motion/occlusion/crossing/intrusion/vehicle/counting; SD 256GB; DC12V/PoE ≤8W (12W IR); 2-in-1 SPD ±6kV; IP67; -40℃~+60℃; MTBF ≥100,000h; GB/T 28181/GB 50395
Plate capture (KITOZER-CAM-LP500) 1/1.8″ global shutter 5MP 2592×1944@25fps; strong-light suppression; 12mm F1.4; strobe ≥30m; plate types; ≥99% day/≥97% night; ≤200ms; vehicle/brand/color; GE+RS485; AC24V/DC12V ≤15W; IP66; -30℃~+70℃
PTZ (KITOZER-PTZ-400) 1/2.8″ 4MP; 23×/16×; 360°/-15~90°; 256 presets ≤0.1°; 8 cruises; IR ≥150m smart; 120dB; tracking/face; H.265+; SD 256GB; AC24V ≤30W; 3-in-1 SPD; IP66 IK10; -40℃~+65℃
Dome (KITOZER-CAM-D200) 2MP 1080P; 2.8mm 90°; 30m IR; DC12V/PoE ≤5W; IP40
Transceiver (KITOZER-FE-100) 10/100M + SC SM single-fiber 20km; DC5V ≤5W; IP40; -40℃~+75℃
Aggregation switch (KITOZER-IS-24T4S) 24GE + 4GE SFP; ≥56Gbps/42Mpps; 4K VLAN; ERPS <50ms; static/RIP; dual DC12-48V; surge ±4/±2kV; DIN; -40℃~+75℃; MTBF ≥200,000h
Core switch (KITOZER-CS-48T8S) 48GE + 8×10G SFP+; ≥336Gbps/132Mpps; static/RIP/OSPF/BGP; stacking 9; ACL/DOS; dual AC220V; 1U
Armored fiber GYTA-8B1, 8-core G.652D; ≤0.36/0.22dB/km; tensile 600/1500N; crush 300/1000N/100mm; ≥25 years
NVR (KITOZER-NVR-32) 32ch; 4×4K or 16×1080P decode; 4 SATA (20TB); HDMI4K+VGA; timed/motion/alarm/manual; 1/4/9/16 playback; 2GE; 16 in/4 out; ONVIF/GB 28181; ≤20W; 1.5U
Surveillance drive 8TB SATA3 7200rpm 256MB; MTBF ≥1,800,000h; ≥180TB/year; error-recovery + vibration compensation
Decoding matrix (KITOZER-DM-16) 16×4K or 32×1080P; 16 HDMI; 128ch in; split/window/roaming/splice/PIP/patrol; 16-screen; H.265/H.264; 2GE; ≤150W; 4U
Streaming server (KITOZER-SVR-M1) 2×Xeon E5-2620V4; 32GB ECC; 2TB + 4 bays; 4GE; 550W redundant; ≥100 streams; Win Server 2019; MTBF ≥100,000h

10.3 Center Display and Control

55″ splicing (KITOZER-LCD-55): 1920×1080; 3.5mm; 500cd/m²; 4000:1; 178°; 8ms; ≥60,000h; HDMI/DVI/VGA/BNC/USB; RS232 cascade; any row×column; ≤180W; 7×24. Wall bracket: aluminum+steel; 3×3; ±1mm six-way; ≥80kg/screen; ≤150mm. Triple console: 1800×900×750mm; steel 1.2mm; keyboard trays/device bays/cable ducts. Workstation: i7-12700; 32GB; 1TB NVMe+4TB; 4GB GPU; 27″ 2K. 3D keyboard: PTZ/matrix/wall; 3D joystick; 2.8″ LCD; RS485/232/GE; Pelco-P/D/Visca.

10.4 Power, Lightning and Earthing

2-in-1 SPD: power+network; In 10kA/Imax 20kA; signal ≤15V / power ≤1500V; RJ45 1000M; IP65; ≤1ns; failure window. Room SPD: 380V three-phase; In 40kA/Imax 80kA; common+differential; ≤25ns; DIN; remote alarm; GB 18802.1. UPS (KITOZER-UPS-10K): 10kVA/8kW online; 304-456V 3-phase in; 220V±1%; 2h backup; 0ms; LCD; RS232/SNMP; battery cabinet; ≤55dB. Distribution box: 600×800×200mm; main + 10 branches; leakage; SPD. Earthing busbar: T2 40×4mm tin-plated with insulators — room equipotential ≤4Ω overall.

11. Key Advantages and Customer Value

11.1 Device Adaptation to Harsh Tunnel Environment

All front-end devices per tunnel humidity/dust/temperature/light complexity: IP65+ protection, industrial wide-temperature components, vibration/salt-fog resistance, 7×24 stability; high-brightness LEDs penetrating smoke; ultra-wide-dynamic and strong-light-suppression cameras countering headlight glare.

11.2 Stable Architecture with Redundant Links

Fiber backbone + industrial switches with ERPS ring protection — single-point failure does not affect the system; redundant power on core devices; signal control offline-capable — basic control unaffected by network loss, safeguarding tunnel traffic.

11.3 Complete Functions, High Intelligence

Preplanned automatic signal control and remote centralized dispatch for normal operation, maintenance and incidents; video intelligent analysis and fault self-check detecting anomalies early; both systems link for higher overall control efficiency.

11.4 Standardized Design for Expansion and Maintenance

National standards, universal protocols and interfaces for upgrades and third-party integration; modular design simplifies troubleshooting and replacement; lower long-term O&M cost.

11.5 Full-Process Service

Design, supply, installation, commissioning, acceptance and after-sales; 24h response; periodic inspection — long-term stable operation.

12. Technical Q&A (50+ Items)

12.1 Signal System

Q1: What environment requirements do tunnel lane indicators need?

A: High humidity, dust, temperature differentials and corrosion — IP65+ dust/water protection; -40℃~+70℃ working; corrosion/vibration resistance; penetrating light with ≥200m visibility; auto brightness to avoid night glare.

Q2: Why countdown signals at tunnel entrances?

A: Drivers anticipate switching — earlier deceleration/preparation, fewer hard brakes and red-light running, smoother flow; clear control duration during flow-limiting improves experience; high brightness and long visibility for outdoor strong light.

Q3: Core functions of the signal area controller?

A: ≥32 independent circuits; five modes (manual/timed/remote/inductive/preplan); fault self-check with per-circuit monitoring and alarms; ≥100 stored preplans for normal/maintenance/incident scenarios with one-key call; standard protocols for platform integration.

Q4: What do variable speed-limit signs do?

A: Real-time speed adjustment per flow/incidents; lower limits for water/ice/fog; speed prompts for maintenance sections; entrance flow control per tunnel state — higher efficiency and safety.

Q5: Cable laying precautions in tunnels?

A: Flame-retardant aging/moisture-resistant cables (RVV); galvanized steel conduit with pressure resistance, code-compliant fixing and bends; IP65+ junction boxes sealed against moisture; avoid structural stress zones, vibration-proof fixing; clear labels.

Q6: How is green-wave coordination achieved?

A: Multi-controller synchronization ≤10ms with timed plans aligning adjacent entrance signals for coordinated vehicle flow.

Q7: What happens on communication loss?

A: The controller degrades to local timed/manual control automatically — basic functions continue; alarms flag the outage; recovery resumes remote control.

Q8: How are signal circuits protected?

A: Per-circuit fuses, overcurrent/short protection on IO modules; power-port surge protection on the controller; insulation and withstand testing per GB 25280.

12.2 Surveillance

Q9: Tunnel-dedicated vs. ordinary cameras?

A: ≥120dB ultra-wide dynamic countering headlight glare with balanced bright/dark imaging; star-level low-light color imaging; IP67 for humidity/dust; vibration/EMI resistance; tunnel-specific image optimization reducing light trails.

Q10: Why fiber for tunnel video?

A: Long-distance low-loss transmission; large bandwidth for multi-stream HD; immunity to EM interference from tunnel electromechanical equipment; non-conductive lightning safety; long life and low maintenance.

Q11: What storage duration is required?

A: ≥30 days generally; 90 days for key areas (entrances, accident-prone sections) per codes; H.265 at 2-4Mbps per 4MP channel; capacity precisely calculated with margin.

Q12: Core functions of the video wall?

A: Multi-channel on-wall display with splits; splicing for full-area maps/key areas; windows/roaming with drag and scale; patrol groups; integration of signal and variable-sign data for one-screen visualization.

Q13: Why 2-in-1 SPDs at front-end devices?

A: Lightning-induced surges on power and network lines damage cameras; the 2-in-1 SPD diverts both to ground; combined with room-level SPD and earthing for multi-level protection in humid tunnels.

Q14: How is plate capture accuracy at night?

A: Global shutter + digital strong-light suppression + strobe sync achieve ≥97% night accuracy on headlight-glare scenes.

Q15: How does the ERPS ring protect transmission?

A: Ring topology with <50ms self-healing — a broken link or failed node re-routes instantly; video continues without visible interruption.

Q16: Can the system support intelligent analysis?

A: Yes — motion, intrusion, crossing, gathering detection and vehicle counting on cameras; face recognition and auto tracking on PTZs; fault self-check with alarms.

12.3 Construction and O&M

Q17: Key construction precautions?

A: Traffic control with signs and dedicated safety officers; code-compliant conduit fixing, corrosion protection and waterproof joints; precise signal/camera angles and pole verticality; earthing ≤4Ω; comprehensive testing of offline operation and fault alarms.

Q18: What routine maintenance is needed?

A: Monthly front-end checks (appearance, fixing, lens/visor cleaning, cable integrity); quarterly device parameters and earthing tests; room dusting, UPS battery checks, config/recording backup; software updates; quarterly professional inspection and annual deep maintenance.

Q19: Earthing requirements?

A: Combined earthing (room working + lightning) ≤4Ω; equipotential copper busbar connecting all equipment/racks/pipe; outdoor poles and boxes individually earthed with galvanized flat steel or copper leads; regular resistance testing, especially before/after rainy seasons; strong/weak earth separated.

Q20: How is the system verified at acceptance?

A: Per-device energization; signal lamp states and control modes; offline degradation; video coverage/angles; storage duration; decoding and video-wall functions; fire/alarm linkage; earthing and lightning tests; documentation — signed acceptance.

Q21: How long does construction take?

A: ~32 days: preparation 3, cabling 7, foundations/poles 5, front-end 6, center 4, commissioning 5, acceptance 2 — adjustable.

Q22: What is the warranty?

A: 2 years whole system; free repair/replacement of non-human faults; 7×24 support, 2h response, 4h urban on-site; quarterly inspections with reports; lifetime software upgrades.

Q23: What training is provided?

A: 2-day concentrated training at acceptance — basic operation, signal/video control, playback, alarms; maintenance and fault finding; management (permissions, preplans, logs, reports); hands-on with manuals.

Q24: What spares are supported?

A: Core spares stocked for fast replacement; backup units for major faults; preferential lifetime supply.

Q25: Can the two systems integrate?

A: Yes — the signal platform integrates with video and tunnel platforms for linked control (e.g. incident → lane closure + camera focus + variable speed reduction).

Q26: How is video data secured?

A: Multi-level user permissions with audit logs, standard protocol encryption options, physical room access control and UPS-backed storage.

Q27: What about extreme weather and lightning?

A: Devices rated -40℃~+70℃ with 500h salt spray; multi-level SPDs; poles with lightning rods and earthing ≤4Ω — resilient in thunderstorms and coastal environments.

Q28: How is capacity expanded later?

A: Add cameras to the NVR/matrix (license expansion), extend the ring with more switches, add signal circuits via IO modules — modular growth without core replacement.

Q29: Why choose the KITOZER/Lain solution?

A: Source factory with 20+ years of tunnel/room engineering, full-system integration (signals + video), tunnel-specific devices, standard construction and complete after-sales.

Q30: What makes the system future-proof?

A: GB/T 28181 and GB/T 20999 standard protocols, modular architecture and open APIs — ready for smart-tunnel upgrades and multi-system linkage.

Q31: How is signal visibility ensured in smoke?

A: High-brightness LEDs (≥8000cd/m²) with strong penetration and red/green contrast; anti-condensation seals and heated options in humid environments maintain optical clarity.

Q32: What are the pedestrian signal countdown features?

A: Two-digit 200mm reversible countdown (99s), synchronized with the lamp phase, visible ≥150m — guiding safe crossing at tunnel-adjacent channels.

Q33: How are preplans executed automatically?

A: The controller stores ≥100 preplans with time-slot or trigger conditions; the platform configures them visually; e.g. peak flow, maintenance window or incident response auto-executes without manual intervention.

Q34: What if a signal lamp circuit fails?

A: Per-circuit current monitoring detects abnormal output instantly — alarm with location reported to the platform; the remaining circuits continue; hot-swap lamp units for quick recovery.

Q35: How is camera image quality maintained in dark tunnels?

A: Star-level sensors with color 0.001Lux imaging plus smart IR (even, no overexposure) and 3D DNR keep clear day/night images without supplementary lighting.

Q36: How are license-plate images used?

A: Vehicle entry/exit records with plate, time and snapshots — supporting traffic statistics, tolling interfaces and incident tracing.

Q37: How is the video wall controlled?

A: Via WEB/client software or the 3D keyboard — splits, windows, roaming, splicing and patrol with saved scene presets for one-key recall.

Q38: What redundancy protects storage?

A: NVR RAID-capable bays with surveillance drives (MTBF ≥1.8M h); dual GE ports with fault tolerance; UPS-backed power; recording continuity verified in trial runs.

Q39: How are signal and video systems linked?

A: On incident or alarm, the platform can close lanes, switch variable signs to reduced speed and steer cameras to the scene — one-click coordinated response.

Q40: What are the UPS backup features?

A: 10kVA online double-conversion with 2h full-load backup, 0ms transfer, remote monitoring — the center keeps controlling and recording during outages.

Q41: How is the ring network configured?

A: Access/aggregation switches form ERPS rings with <50ms self-healing; fiber transceivers connect remote points; VLANs isolate services; QoS prioritizes video.

Q42: What documentation is delivered at acceptance?

A: Device manuals and certificates, test reports (lamp, video, storage, earthing, lightning), as-built drawings, commissioning records, platform guides, training materials.

Q43: How is the 72h stability verified?

A: Continuous trial run covering day/night cycles with offline simulation, fault drills and alarm verification — issues rectified before formal acceptance.

Q44: What are the environmental ratings of outdoor devices?

A: IP65/IP66/IP67 per device, -40℃~+70℃, 500h salt spray, vibration/shock per GB/T 2423 — suited to tunnels, plazas and coastal areas.

Q45: How is maintenance cost controlled?

A: Modular devices with standard parts, remote diagnosis and configuration, quarterly inspections preventing faults, local spares — lower lifecycle cost.

Q46: Can third-party cameras integrate?

A: Yes — ONVIF and GB/T 28181 standard access into the NVR, matrix and platform; mainstream brand private protocols supported.

Q47: How are alarms notified?

A: Platform popup with sound, SMS push, video-wall indication and logs — operators respond per graded severity.

Q48: What if the center is down?

A: Field controllers run preplans locally and cameras record continuously; on center recovery, status and data synchronize automatically.

Q49: How is the tunnel environment monitored for the system?

A: Optional environment sensors (temperature, humidity, visibility) feed the platform; abnormal conditions trigger alerts and speed-limit adjustments.

Q50: What makes this solution cost-effective?

A: One integrated provider, standardized products, fiber ring without duplicate cabling, energy-efficient LEDs/H.265 storage and low-maintenance design — optimal lifecycle value.

13. Construction Schedule

13.1 Stage Division

Stage Work Duration Responsible
Preparation Site survey, drawing review, material/equipment arrival inspection, crew disclosure 3 days PM
Cable laying Fiber/cable runs, conduit installation, junction boxes 7 days Construction lead
Foundations and poles Signal/camera pole foundations, pole erection 5 days Construction lead
Front-end installation Signals, lane indicators, cameras, SPDs — installation and wiring 6 days Technical engineer
Center installation Switches, storage, decoding, video wall, console deployment 4 days Technical engineer
Commissioning Per-device tests, system integration, function tests, optimization 5 days Technical lead
Acceptance As-built documentation, owner acceptance, training, handover 2 days PM

Total: 32 days (adjustable per site).

14. Construction Organization and Quality/Safety Measures

14.1 Organization

Project-manager responsibility system: PM — overall progress/quality/safety/cost and coordination; technical lead — disclosure, guidance, commissioning, problem solving; construction lead — crew execution, cabling and installation; safety officer — safety management, disclosure, hazard inspection; QC — quality checks, incoming inspection, process acceptance; documentation clerk — records, inspection applications, as-built documents.

14.2 Pre-Construction Preparation

Technical: crew familiarization with drawings and solution; technical and safety disclosure; construction codes and quality standards clear. Materials: stocking per lists; incoming inspection (spec/qty/quality) — unqualified prohibited. Site: survey of conditions, temporary power and material areas; coordination with civil works for reserved pre-embedded elements.

14.3 Core Construction Processes

Cable laying: per drawing routes; firm conduit fixing with elbows at bends; straight neat cables with labels; fiber avoiding excessive bending with attenuation tests after splicing. Device installation: poles vertical and firm (verticality per code); devices at correct angles, firmly fixed with waterproof sealing; room equipment rack-mounted neatly with standardized wiring and clear labels. Commissioning: per-device energization first, then link tests, then full-system integration; functional indicators recorded per design.

14.4 Quality Assurance

Three-level inspection (crew self-check, QC re-check, PM final); strict process acceptance — unqualified upstream stops downstream; all materials with certificates and test reports; concealed works with acceptance records.

14.5 Safety and Civilized Construction

Strict site safety rules with PPE; harnesses and warning zones for high work; code-compliant temporary power with leakage protection; daily cleanup — work finished, site clean; tunnel work per traffic-control requirements with warning signs and a dedicated safety officer.

14.6 Schedule Assurance

Detailed daily plan with review and adjustment; parallel cross-trades for efficiency; advance stocking; sufficient crew and tools; timely material arrival — on-schedule completion.

15. After-Sales Service

15.1 Warranty

2-year free whole-system warranty from acceptance — non-human faults repaired/replaced free; 7×24 hotline; response ≤2h; on-site ≤4h urban; quarterly free inspections with reports; renewable maintenance agreements after warranty.

15.2 Inspection

Quarterly inspections — device status, cleaning, hazard elimination; annual deep maintenance; formal reports.

15.3 Upgrades

Lifetime free software upgrades; preferential hardware supply; function expansion and third-party integration per needs.

15.4 Spares

Core spares in stock for fast replacement; backup devices minimize downtime.

15.5 Service Flow

Report → register → remote diagnosis → on-site if needed → repair and test → customer confirmation → follow-up and archive.

16. Training Plan

16.1 Audience

System administrators, duty operators and O&M staff.

16.2 Content

Basic operation: login/interface, signal-lamp control, video monitoring, screen switching, playback/query. Maintenance: daily device checks, common fault finding and handling, simple maintenance. Management: user permissions, preplan configuration, log query, report export.

16.3 Methods

On-site hands-on + theory with real operations; operation manuals and materials delivered.

16.4 Schedule

2-day concentrated training at acceptance; refresher training available per needs.

16. Training Plan

16.1 Training Objectives and Audience

Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.

Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.

16.2 Tiered Training Content System

Level 1: Basic operation training (1 day)

– Basic principles: system concepts, structure composition, performance indicators;

– Daily operation standards: correct operation of equipment, control and safety systems;

– Daily inspection contents: daily/weekly/monthly check items;

– Safety precautions: usage prohibitions and emergency handling procedures.

Level 2: Maintenance training (1 day)

– Detailed structure of each subsystem and working principles;

– Daily maintenance methods: cleaning, fastening checks, routine care;

– Common fault identification and simple handling;

– Emergency handling procedures for power failure, fire and equipment faults.

Level 3: Advanced management training (as needed)

– Performance influencing factors and how to avoid degradation;

– Upgrade and expansion knowledge and specification requirements;

– Relevant national standards interpretation.

16.3 Training Methods and Schedule

– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;

– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.

16.4 Training Assessment and Documentation Delivery

– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;

– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.

17. Anonymous Typical Project Scenarios

All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.

17.1 Urban Main Road Underpass Tunnel Electromechanical Monitoring Project

Project background. An urban underpass tunnel of 1.2km bidirectional needed complete video surveillance and traffic signal control to enhance passage safety and management efficiency.

Implementation. 36 HD bullets and 6 PTZs inside; 40 lane indicators; 8 groups of entrance signals; a center control platform with a splicing video wall; fiber ring transmission with industrial switches.

Results. Stable operation for over 3 years with effective traffic control and rapid incident response; tunnel safety and management efficiency significantly improved.

17.2 Municipal Expressway Tunnel Electromechanical Retrofit Project

Project background. An aging tunnel electromechanical system needed upgrading — old cameras and manual control replaced with HD imaging and intelligent signal management.

Implementation. Replaced front-end cameras with HD devices; new intelligent signal control system; optimized the transmission network; achieved visualized, intelligent tunnel control.

Results. System fault rate greatly reduced and O&M cost down 30%; centralized preplanned control improved response to traffic incidents.

17.3 Industrial Park Tunnel Security and Control Project

Project background. An industrial park’s tunnel needed integrated security and traffic control aligned with the park management platform for vehicle access and safety.

Implementation. Integrated security + traffic control system with signal control, video surveillance and park platform linkage.

Results. Unified management of vehicle passage and security; linked control with the park platform; reliable operation meeting park access and safety needs.

18. SEO Optimization Section

All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.

18.1 Keyword System

– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;

– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;

– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;

– Brand keywords: KITOZER, Guangzhou Lain.

18.2 SEO Tag System

– Title tag: the article title — Guangzhou Lain KITOZER;

– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;

– H1 tag: the article title;

– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.

18.3 Internal Link Anchor Text

– Core anchor text: technical design solution, system construction;

– Long-tail anchor text: configuration list, technical parameters, construction plan;

– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.

19. Official Contact Information

– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Official Website: https://gdlain.com

– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)

– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.