KITOZER 1U vertical cable manager organizes patch cords on the front and rear of network and server racks, reducing cable congestion and maintaining controlled bend radius at patch panels and switches. The plastic ring design with finger ducts prevents cable snagging during moves adds and changes, and the open frame allows technicians to reach behind cables without removing the manager.
Table of Contents
ToggleProduct Overview
The manager is constructed from 1.0mm cold rolled steel with a black powder coat frame and UL94 V0 flame retardant ABS plastic ring fingers. The 1U unit mounts on standard 19 inch rack rails and accepts both short patch cords and longer jumpers. Removable plastic fingers allow partial access to specific cable bundles without taking the whole manager off the rack. The open top and bottom design supports continuous vertical cable routing between managers above and below.
Technical Specifications
19 inch 1U rack mount, steel frame 1.0mm, black powder coat, ABS V0 plastic ring fingers, open top and bottom, removable fingers, maximum cable bundle capacity 50 cords, minimum bend radius 35mm, mounting screws included, operating temperature minus 10 to plus 60 C, KITOZER, 3 year warranty.
Applications
This 1U manager is installed between patch panels and switches on the front of network racks, and between servers and PDUs on the rear. It is standard in enterprise server rooms, data hall IDFs, telecom central offices, and security operations centers where dense patch cord routing requires organization. In small closets, a single manager between the patch panel and switch prevents the cable pile up that typically develops after a few months of adds and moves.
Advantages
Plastic ring fingers prevent cable damage compared with sharp metal edges, and the V0 flame rating meets data center fire code. Removable fingers allow partial access so technicians can add or remove a single cable without disturbing the whole bundle. Open top and bottom design supports continuous vertical routing, eliminating sharp horizontal transitions. The 1U height matches standard patch panel spacing, and the black finish blends into the rack. Steel frame resists sag under dense cable load.
Installation and Maintenance
Mount the manager directly below a patch panel or switch, leaving no gap for cables to hang unsupported. Route patch cords from front ports into the rings and bundle loosely with Velcro straps, never cable ties that crush conductors. During quarterly inspection, re-bundle loose cords, replace cracked plastic fingers, and verify bend radius at the manager entry. Keep spare fingers on site because they are the first component to wear out in high traffic racks.
Price
From $18/pc. Contact plus 86 13922289957 for cable manager pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com