KITOZER
KITOZER

Automated Test Shielding Box and 2.4G Band Signal Semi-Shielding Test System

Table of Contents

1. Cover / Document Information

– Document Title: Automated Test Shielding Box and 2.4G Band Signal Semi-Shielding Test System Technical Design Solution

– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Date: August 2026

– Version: V1.0

– Project Type: Technical design solution for Automated Test Shielding Box and 2.4G Band Signal Semi-Shielding Test System

2. Table of Contents Structure

1. Company Introduction

2. Project Overview

3. User Requirement Analysis

4. Overall Design Description

5. Detailed System Design and Product Technical Parameters

6. Project Quotation and Configuration List

7. Core Solution Advantages

8. Technical Q&A

9. Construction Schedule Plan

10. Construction Organization Plan

11. After-Sales Service System

12. Operation and Maintenance Training Plan

13. Typical Project Cases

14. SEO Optimization System and Website Backend Configuration

15. Contact Information

3. Company Introduction

3.1 Company Development Overview

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.

After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.

3.2 Core Business System

The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:

– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;

– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;

– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;

– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.

3.3 Brand and Qualification Honors

The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.

3.4 Core Competitive Advantages

1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;

2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;

3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;

4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.

4. Project Background and Objectives

4.1 Project Background

With smart-home and wireless IoT growth, 2.4GHz products (wireless remotes, WiFi, Bluetooth) are mass-produced. Traditional open-bench testing suffers EMI, unstable data, low efficiency and poor consistency; PCB shield-can and structural shielding designs also lack standardized verification. A 2.4GHz-controlled semi-shielded automated test system is required.

4.2 Project Objectives

Build a 2.4GHz-controlled semi-shielded test environment (shield external interference while keeping a directional signal path simulating real use); multi-station automated batch testing replacing manual operation (5-8x efficiency); integrated signal power control, band filtering and abnormal alarms; complete remote PCB + structural shielding design and verification guidance; safe, stable, expandable and maintainable.

4.3 Scope

Suitable for 2.4GHz wireless product function/RF performance/EMI pre-test/antenna testing: yuba remotes, smart-lock remotes, WiFi modules, Bluetooth modules, wireless mice/keyboards, car remote keys.

5. User Requirement Analysis

5.1 Functional

Shielding isolation (2.4G interference isolation with directional antenna semi-shielded environment); automated testing (pneumatic lid, automatic product pressing, multi-station, two-hand start); signal measurement/control (precise power adjustment, band selection, real-time display, abnormal sound/light alarm); imaging recording (HD camera with filtering); data communication (Ethernet/USB to host, MES expandable); custom fixture (contour and test points of the specified remote).

5.2 Performance

Shielding >=80dB @2.4GHz closed; 8 stations standard (expandable); power step 0.5dB accuracy +-0.5dB; MTBF >=10,000h; lid/cylinder life >=1M cycles.

5.3 Structure and Safety

Cold-rolled steel body with powder coating; E-stop, safety interlock, two-hand start; complete earthing; filtered/sealed power and air interfaces preserving shielding integrity.

6. Design Principles and Applicable Standards

6.1 Design Principles

Source-factory customization: size, stations, modules and fixtures per product/capacity. 2.4G-optimized shielding: openings < lambda/20, multi-point low-resistance earthing, full-perimeter conductive sealing, absorber + directional antenna + multi-level EMI filtering — controlled semi-shielded environment. Automation: pneumatic pressing, automatic signal capture, two-hand start + interlock + E-stop. Integration: one-stop factory-integrated delivery — site power/air only. Industrial quality: long-life components, high MTBF. Full service: 1-year warranty, 7×24 support, lifetime maintenance.

6.2 Applicable Standards

GB/T 12190 (shielding effectiveness measurement), GB 4208 (IP), GB/T 17626 (EMC), UL94 V-0 (flame retardancy), GB/T 9286 (coating), IEC 60297 (19″), relevant RF and safety standards; third-party testing.

7. System Architecture and Working Principle

7.1 Overall Architecture

Body system: lower box (800x600x500mm, 2.0mm steel, composite shielding liner >=60dB @2.4GHz) + pneumatic flip lid (2.0mm, 304 edge trim, conductive seal strip, >=80dB closed) + stainless support columns. Pneumatic drive: lid cylinder (SC40x50) + 10 pressing cylinders (SC32x50 with guide rods) + 15-position valve island + FRL. Electrical control: two-hand start, E-stop, 200W switch-mode supply, signal interface module. Fixture system: 8-station bakelite base + POM contour fixture + pogopin probes. RF components: 2.4G pyramidal absorber, directional antenna (8dBi), impedance matching, USB/DC EMI filters, shielded air feed-through. Signal monitoring: power control module (-30~+10dBm, 0-120dB), SAW band filter (2450MHz), 7″ touch + 21.5″ monitor + dedicated displays, alarm module. Power/safety: 1U distribution host (RCD 30mA, surge), AC input filter. Imaging: 1080P camera with filters, control panel. Remote PCB+structure shielding kit: shield can, BeCu ground fingers, grounding vias, gaskets, screws, keyhole gaskets.

7.2 Working Principle

Products loaded into 8 fixtures; two-hand start closes the lid pneumatically; pressing cylinders press products onto probes; the system transmits a controlled 2.4GHz test signal via the directional antenna (power adjustable 0.5dB steps), the SAW filter selects the band, the receiver measures power and judges pass/fail against thresholds; camera records the process; results displayed and uploaded; abnormal signals trigger sound/light alarm; E-stop/interlock cut power on any safety breach.

8. Detailed Technical Design

8.1 Body and Shell

Lower box: cold-rolled steel >=2.0mm (reinforced >=3.0mm at load points), welded frame; white electrostatic powder 60-80um (adhesion 1, salt spray >=48h); inner walls fully lined with blue composite shielding liner (conductive foam + tinned copper mesh, >=0.8kg/m2, >=60dB @2.4GHz); 4 adjustable feet (+-20mm); fork slots; 800x600x500mm (custom); static >=500kg; IP40 shell. Lid: 2.0mm steel, 20mm 304 edge trim; pneumatic flip >=90° smooth; full-perimeter embedded conductive seal (compression 3-5mm); overall shielding >=80dB @2.4GHz closed; safety interlock with light curtain and locks; ~35kg. Support columns: 304 solid round bar D25x3, precision spherical bearings (+-15°), >=100kg each x2, mirror polished. Seal strip: BeCu spring + conductive foam composite (Cu-Ni conductive cloth + polyurethane), 10x20mm, resistivity <=0.05 ohm-cm, >=100dB @2.4GHz, compression 30-50% (permanent set <=15%), >=10,000 cycles, -40~+120 degC, slot mount.

8.2 Pneumatic Drive

Lid cylinder (SC40x50): D40/50mm, filtered air (>=40um), 0.1-0.8MPa rated 0.5MPa, push ~628N/pull ~580N, two-way adjustable cushioning, 50-500mm/s, 304 honed bore, trunnion + spherical bearings, >=5M cycles, -20~+80 degC. Pressing cylinders (SC32x50 with guide rods, x10 incl. 2 spares): D32/50mm, dual parallel guide rods (anti-rotation, repeatability +-0.05mm), 0.1-0.7MPa rated 0.4MPa, push ~402N, silicone/rubber head (Shore 50, no product damage), anodized aluminum body, >=3M cycles. Valve island: 5/2 pilot solenoid, 15 valve positions, DC24V, response <=10ms, flow >=700L/min, IP65, >=50M cycles, DIN rail. FRL: 40um filter + regulator 0.05-0.8MPa with gauge + lubricator, G1/4.

8.3 Operation Panel and Electrical

Two-hand start: 2 x green illuminated self-reset buttons (phi22, NO+NC silver contacts, DC24V 5A, IP65, >=1M cycles) — simultaneous trigger required. E-stop: red mushroom twist-reset (2NC forced-break, AC250V/DC30V 10A, IP65) cutting all power. Supply: AC110-240V -> DC24V 200W, >=88%, ripple <=50mVpp, full protections, 1500V isolation, CCC/CE. Signal interface: RJ45 + 2 USB + RS485 + 2 SMA; TCP/IP, Modbus RTU; WiFi/Bluetooth for wireless monitoring; EMI-filtered sealed interfaces.

8.4 Fixture System

Base: phenolic bakelite orange >=20mm (surface resistance >=10^12 ohm, insulation >=10kV/mm, CNC +-0.05mm, anti-static). Contour fixture: white POM, contour slots + locating pins, 8 stations, +-0.1mm, quick-release for changeover. Probes: pogopin (BeCu gold-plated barrel >=2um, hard-alloy gold-plated plunger, stainless spring), total travel 5mm / rated 3mm, contact <=20m ohm, 1A, >=100,000 presses, FR-4 pin board 5mm.

8.5 2.4G RF Components

Absorber: ferrite-composite plate 300x300x20mm, 2.0-2.5GHz optimized, reflectivity <=-20dB @2.4GHz (normal), flame-retardant PU + ferrite powder, UL94 V-0, -40~+85 degC, adhesive-lined on all six inner faces — eliminates standing waves. Directional antenna: flat panel 2400-2500MHz, gain >=8dBi, VSWR <=1.2, 50 ohm, beam <=30° both planes, front-to-back >=20dB, linear polarization, SMA female, delay <=100ns over 0-1m, adjustable mount. USB EMI filter: Type-A, >=100dB @2.4GHz out-of-band, loss <=0.5dB (DC-480MHz), 5V 2A, OCP + +-15kV ESD, metal shielded. DC EMI filter: 12-24V 5A, CM >=100dB / DM >=60dB @2.4GHz. Air feed-through: phi8 all-metal shielded bulkhead + sealed base IP65. Matching: >=99% match, 50 ohm; RG-type low-loss coaxial + SMA.

8.6 Signal Monitoring and Control

Power control module: -30~+10dBm output, 0-120dB attenuation, 0.5dB steps, +-0.2dB accuracy, 2.4-2.5GHz, max input +20dBm, VSWR <=1.3, touch/RS485 control, <=10ms, DC24V, shielded enclosure. SAW filter: 2450MHz center, 1MHz passband, ripple <=1dB, out-of-band >=100dB, loss <=3dB, 50 ohm, metal shielded SMA. Displays: 7″ industrial touch (1024×600, capacitive 5-point, HDMI+USB, front IP65) showing power/attenuation/status/alarms/settings; 21.5″ 1080P monitor (HDMI/VGA); 7″ power display (RS232/485); 10.1″ multi-view switcher. Alarm: abnormal signal/leakage sound/light alarm.

8.7 Power Distribution and Safety

Distribution host (1U): AC110-240V, 200W, 4xDC24V + 4xDC12V outputs with independent fuses; overcurrent/overvoltage/short/leakage (30mA <=0.1s)/surge protection; >=85%; metal shielded with earth terminal. AC input filter: 220V 20A, CM >=100dB / DM >=60dB @2.4GHz. Grounding module: <=4 ohm, M6 brass terminal.

8.8 Imaging System

Camera: 1/2.7″ CMOS 1080P 30fps, 120° wide angle, 8-LED adjustable fill light, USB, metal housing, ceiling-mounted top view. Filters: camera signal filter (>=60dB @2.4G) + PCL control-signal filter (>=60dB). Control panel: integrated image switch and fill-light adjustment.

8.9 Remote PCB + Structure Shielding Kit (per unit)

0.2mm nickel-silver/nickel-plated brass shield can (phi1.8mm staggered holes, bridge >=0.5mm); 8 x BeCu gold ground fingers (compression >=0.3mm, contact <=5m ohm, 4 edges + 4 corners); 12 solder pins (reflow compatible); 48 x phi0.3mm metallized ground vias at 2.5mm pitch around the shield boundary; Cu-Ni conductive foam gasket (<=0.05 ohm-cm, 1.0mm) for structural seams; 4 x M1.6 plated screws with ground washers; 6 x conductive rubber keyhole gaskets (>=20dB @2.4G). Design rules: openings < lambda/20, multi-point low-resistance earthing, full-perimeter sealing.

9. Recommended Configuration and Preliminary Budget

9.1 Configuration Summary

Body: lower box with liner, flip lid, support columns, seal strip, adjustable feet. Pneumatic: lid cylinder, 10 pressing cylinders, 15-position valve island, FRL, tubing. Electrical: two-hand start, E-stop, 200W supply, signal interface module. Fixture: 8-station bakelite/POM fixture set with pogopin probes. RF: absorber, directional antenna, matching module, coaxial + SMA, antenna mount, USB/DC EMI filters, air feed-through + base. Monitoring: power control module, SAW filter, alarm module, 7″ touch, 21.5″ monitor, power display, multi-view switcher. Power/safety: 1U distribution host, AC input filter, grounding module, output distribution. Imaging: camera, camera/PCL filters, control panel. Fixture (remote-specific): custom contour fixture with pressing mechanism. Remote shielding kit: shield can, fingers, pins, vias (PCB process), gaskets, screws, keyhole gaskets. Services: design, production, assembly, factory test (incl. shielding measurement), packing/transport, site installation/commissioning, training.

9.2 Budget Notes

Ex-works price excl. tax/freight (freight ~3% collect; VAT invoice 13% on total+freight); customization (stations, size, bands, MES) quoted separately; tax-inclusive in RMB (CNY) only; ~25 working days standard; 1-year warranty; 7×24 support; 24h Pearl River Delta / 48h national on-site; lifetime maintenance.

10. Technical Specifications

10.1 System Specification Summary

Item Specification
Body 800x600x500mm (custom); 2.0mm cold-rolled steel (3.0mm reinforced); white powder 60-80um (salt spray >=48h); composite shielding liner >=60dB @2.4GHz; 4 adjustable feet (+-20mm) + fork slots; static >=500kg; flip lid 2.0mm with 304 edge trim, pneumatic >=90°, full-perimeter conductive seal (3-5mm); overall shielding >=80dB @2.4GHz closed; 304 support columns >=100kg; seal strip BeCu+foam <=0.05 ohm-cm >=100dB >=10,000 cycles
Pneumatic SC40x50 lid cylinder (628N @0.5MPa, >=5M cycles); 10 x SC32x50 guide-rod pressing cylinders (402N, repeatability +-0.05mm, >=3M cycles); 15-position 5/2 valve island (DC24V, <=10ms, >=50M cycles, IP65); FRL 40um G1/4
Electrical/safety Two-hand start (2 x illuminated, simultaneous) + red mushroom E-stop (2NC, force-break); 200W supply (AC110-240V -> DC24V, >=88%, full protections); RJ45 + 2USB + RS485 + 2SMA + WiFi/BT; EMI-filtered sealed interfaces
Fixture 8-station bakelite base (>=10^12 ohm) + POM contour fixture (+-0.1mm, quick-release) + pogopin probes (<=20m ohm, 1A, >=100k presses)
RF Ferrite absorber 300x300x20mm (<=-20dB @2.4GHz, UL94 V-0, 6 faces); directional antenna >=8dBi VSWR<=1.2 beam<=30° F/B>=20dB delay<=100ns; USB filter >=100dB; DC filter CM>=100/DM>=60dB; phi8 shielded air feed IP65
Monitoring Power control -30~+10dBm, 0-120dB, 0.5dB steps, +-0.2dB, <=10ms; SAW 2450MHz 1MHz passband out-of-band >=100dB; 7″ touch + 21.5″ monitor + 7″ power display + 10.1″ multi-view; sound/light alarm
Power/safety 1U distribution host AC110-240V 200W (4x24V + 4x12V, RCD 30mA <=0.1s, surge); AC input filter 20A (CM/DM >=100/60dB); grounding <=4 ohm
Imaging 1080P 30fps 120° camera with 8-LED light + camera/PCL filters >=60dB; control panel
Remote shielding kit 0.2mm nickel-silver can (phi1.8 holes, bridge >=0.5mm); 8 BeCu fingers (<=5m ohm); 12 pins; 48 vias 2.5mm pitch; conductive gaskets; 4 ground screws; 6 keyhole gaskets >=20dB — opening <lambda/20, multi-point earthing, full sealing
Performance Shielding >=80dB @2.4GHz; 8 stations (expandable); power step 0.5dB +-0.5dB; MTBF >=10,000h; lid >=1M cycles; throughput ~1,440 units/h (5-8x manual)
Delivery ~25 working days (3+7+10+5+3+2+1+1); 1-year warranty; 7×24 support; 24h/48h on-site; annual free inspection; lifetime maintenance

10.2 Standards Compliance

GB/T 12190 (shielding measurement with factory data report), GB 4208, GB/T 17626, UL94 V-0, GB/T 9286, IEC 60297; per-unit shielding test and 24h aging before shipment.

11. Key Advantages and Customer Value

11.1 Source-Factory Customization

20 years of shielding/test-equipment expertise — stations, size, modules and fixtures customized per product/capacity; free design.

11.2 2.4G-Dedicated Precision

Opening < lambda/20, multi-point low-resistance earthing, full-perimeter conductive sealing, absorber + directional antenna + multi-level EMI filtering — controlled semi-shielded environment with reliable data.

11.3 Automated Batch Efficiency

8 stations with pneumatic pressing and automatic capture — 5-8x manual efficiency, fewer errors, consistent results; two-hand start + interlock + E-stop for safety.

11.4 Integrated One-Stop Delivery

Shielding, pneumatic, electrical, RF, monitoring, imaging and fixtures factory-integrated and debugged — site power/air only.

11.5 Industrial-Grade Durability

Cold-rolled steel + stainless structure, long-life seals/probes, high MTBF — continuous production-line operation.

11.6 Complete After-Sales

1-year warranty, 7×24 hotline, 24h/48h on-site, annual inspection, lifetime support and cost-price spares.

12. Technical Q&A (50+ Items)

12.1 Principles

Q1: Semi-shielded vs full shield box?

A: Full shield completely isolates inside/outside (EMI/sensitivity tests); semi-shielded uses a directional antenna inside the shielded cavity — only the specified direction/strength signal enters, simulating real use for function and range tests (ideal for 2.4G remotes).

Q2: Why does poor shielding grounding radiate?

A: An ungrounded/high-resistance shield becomes a conductor with induced currents — monopole-antenna effect amplifying specific bands and failing RE margins; shielding requires low-resistance, multi-point, reliable earthing.

Q3: Why openings <=2mm?

A: Leakage scales with opening/wavelength; < lambda/20 gives >=30dB attenuation; at 2.4GHz lambda ~12.5cm, lambda/20 ~6.25mm — 1.5-2mm design margin ensures effectiveness with ventilation.

Q4: What does 80dB mean?

A: Field attenuated ~10,000x (1/10^4) — external interference practically eliminated; verified per GB/T 12190 with factory and site reports.

12.2 Performance

Q5: Shielding effectiveness and verification?

A: >=80dB @2.4GHz closed (>=100dB at key seals); factory signal-source + spectrum test per GB/T 12190 with data report; site re-test on acceptance.

Q6: How many units and throughput?

A: 8 stations standard; cycle 10-30s (e.g. 20s -> ~1,440 units/h) — 5-8x manual; stations expandable.

Q7: Power control precision?

A: -30~+10dBm range, 0-120dB attenuation, 0.5dB steps, +-0.2dB accuracy — meets various sensitivity grades.

Q8: Test stability?

A: Absorber-lined cavity eliminates standing waves; SAW filter selects the band; case: fluctuation from +-5dB to +-0.5dB.

Q9: How are different distances simulated?

A: Digital attenuation simulates equivalent distance (0-50m per case) — car-key tests matched real-vehicle results 95%+.

12.3 Installation and Use

Q10: Site conditions?

A: Level floor, AC220V >=10A, 0.5-0.7MPa clean air (phi8), earthing <=4 ohm.

Q11: Operator qualification?

A: None special — 1-2h training; Chinese touch interface with permissions (operator start/stop only).

Q12: Daily maintenance and consumables?

A: Wipe seal strip, drain FRL, check probe wear; consumables: seal strip (~1yr), probes (>=100k presses), cylinder seals — stocked at cost.

Q13: Changeover to other models?

A: Quick-release fixtures — swap contour fixture + probe board; body unchanged; custom fixtures per new product.

Q14: Multi-band expansion?

A: Reserved slots — add antenna/filter/absorber for Bluetooth/5G etc. and upgrade software — no replacement.

Q15: MES integration?

A: Ethernet/RS485 with Modbus/TCP/IP — custom data upload, defect statistics and traceability.

Q16: E-stop behavior?

A: Cuts all power instantly; twist-reset; interlock prevents restart until clear.

Q17: Air supply failure?

A: Pressure monitoring and alarms; lid/press cylinders default safe positions; no false test results.

Q18: Camera view?

A: 120° top-down covers all 8 stations; LED fill for dark environments; recording via host.

12.4 Remote Shielding Design

Q19: How should the PCB shield can be designed?

A: 0.2mm nickel-silver/nickel-plated brass, phi1.8mm staggered openings (bridge >=0.5mm), full-perimeter ground via row (2.5mm pitch), 4 edges + 4 corners BeCu fingers, solder pins to ground.

Q20: Why ground vias around the boundary?

A: They ensure low-impedance connection of the can to the PCB ground plane — preventing the can from acting as an antenna; 48 x phi0.3mm vias standard.

Q21: Structural seam shielding?

A: Cu-Ni conductive foam at seams (<=0.05 ohm-cm) plus M1.6 plated ground screws with washers; keyhole openings reinforced with conductive rubber gaskets (>=20dB).

Q22: How is the effect verified?

A: The test system compares radiated levels with/without the shield design; RE margins verified per standards.

12.5 Service

Q23: Warranty?

A: 1 year whole unit; consumables (seals, probes, silencers) at cost; from acceptance.

Q24: Response?

A: 7×24 hotline; 2h solution for general issues; 24h Pearl River Delta / 48h national on-site; major issues escalated with PM follow-up.

Q25: Inspections?

A: Annual free on-site inspection in warranty (cleaning, performance check, hidden risks); annual maintenance agreements after.

Q26: Spares?

A: Stocked wear parts and cores; emergency 48h dispatch; lifetime cost-price original parts.

Q27: Training?

A: 1-day on-site (theory, operation, parameters, maintenance, troubleshooting, safety) with assessment and free retraining; manuals and courseware.

Q28: What documentation is delivered?

A: Shielding test report, operation/maintenance manuals, wiring/pneumatic diagrams, certificates, training records.

Q29: Why choose KITOZER/Lain?

A: Source factory, 2.4G-dedicated engineering, proven appliance/WiFi/automotive cases, full customization and lifecycle service.

Q30: What makes it cost-effective?

A: 5-8x efficiency, 70% staff reduction, 99.5% defect capture (case payback 6 months), reliable shielding and low maintenance.

Q31: What alarms does the system provide?

A: Abnormal signal level, leakage and equipment faults trigger sound/light alarms via the integrated module; parameters visible on the touchscreen with fault codes.

Q32: How is test data recorded and exported?

A: Results (power, pass/fail, timestamps, station ID) are stored and exportable; MES integration uploads automatically for traceability.

Q33: Can the pressing force be adjusted?

A: Yes — regulator adjusts cylinder pressure; silicone heads (Shore 50) prevent product damage; guide-rod cylinders keep repeatability +-0.05mm.

Q34: What if a probe wears out?

A: Replace the pogopin (>=100k presses) — stock available; pin board swap takes minutes; contact resistance verified after replacement.

Q35: Is the system safe around operators?

A: Two-hand start (both buttons within the window), safety interlock cuts power on lid open, E-stop kills all outputs; pneumatic circuits at safe DC24V control.

Q36: How is the lid seal maintained?

A: Full-perimeter BeCu + conductive foam strip with 3-5mm compression; wipe dust/oil regularly; replace after ~10,000 cycles or visible wear.

Q37: Does the absorber need replacement?

A: No — ferrite-loaded PU is durable; check adhesion yearly; re-affix if peeled.

Q38: Can it test products without probes (wireless-only)?

A: Yes — fixtures can hold products without probe contact; the directional antenna path tests RF only; probe stations optional.

Q39: What air quality is required?

A: Clean dry compressed air 0.5-0.7MPa with the FRL (40um filter + regulator + lubricator); optional precision oil-water separator.

Q40: How is the directional antenna aligned?

A: 3D adjustable mount with angle scales — aligned to the product’s antenna position per fixture; verified by max-signal calibration.

Q41: What is the fixture changeover time?

A: Quick-release POM contour fixture + FR-4 probe board — typically under 5 minutes per station set; recipes switch in software.

Q42: Can the system run unmanned?

A: It is operator-loaded (8 stations) but fully automatic per cycle; integration with loaders/robots is customizable for full automation.

Q43: What about ESD protection?

A: Bakelite fixture base (>=10^12 ohm, anti-static), grounding module <=4 ohm, ESD-safe materials — protects sensitive electronics.

Q44: How is the shielding liner installed?

A: Composite conductive foam + tinned copper mesh lining all six inner faces (>=0.8kg/m2, >=60dB) with adhesive backing.

Q45: Can the system be used for EMI pre-testing?

A: Yes — the shielded cavity with filtered interfaces supports radiated/conducted pre-scans before formal certification.

Q46: What are the environmental ratings?

A: Industrial workshop operation; components wide-temperature; housing IP40 with sealed interfaces; -10~+60 degC typical.

Q47: Is remote monitoring available?

A: Yes — WiFi/Bluetooth and Ethernet allow remote viewing, parameter setting and firmware updates; optional MES push.

Q48: What is the power consumption?

A: ~200W total (distribution host rated 200W) — low running cost for continuous production.

Q49: How is acceptance performed?

A: Joint function tests, shielding re-test per GB/T 12190, trial production with customer products, documentation handover, signed acceptance.

Q50: What makes this system future-proof?

A: Modular stations/bands/interfaces, remote firmware upgrades, MES-ready data and fixture changeover support new products and requirements without replacement.

13. Construction Schedule

13.1 Schedule (Standard, ~25 Working Days)

Stage Work Days Responsible Deliverable
1 Scheme confirmation Requirements, design, quote, contract 3 PM Final drawings, quote, contract
2 Procurement Core components, standards, materials with incoming QC 7 Procurement engineer Qualified materials
3 Production Box sheet-metal, coating, fixture CNC, RF components 10 Production engineer Structural parts
4 Assembly/wiring Mechanical assembly, air circuits, electrical wiring, RF routing 5 Assembly engineer Semi-finished machine
5 Factory debug Function debug, shielding test, continuous aging, calibration 3 Debug engineer Inspection report, qualified unit
6 Packing/transport Shock-proof packing, logistics 2-3 Logistics Packed unit
7 Site installation Positioning, power/air, site debug, shielding re-test 1 Field engineer Installed/commissioned
8 Acceptance/training Customer acceptance, operation/maintenance training, documentation 1 Field engineer Acceptance report, training records, docs
9 After-sales Follow-up, support, warranty In warranty After-sales Service records

Custom models extend per complexity.

14. Construction Organization and Quality/Safety Measures

14.1 Organization

PM (1): overall progress/quality/customer coordination. Technical lead (1): design, technical gate, field problem solving. Production/assembly team (3-5): manufacturing, assembly, wiring. Debug/QC team (2): function tests, performance tests, factory inspection. Field team (2): installation, commissioning, training.

14.2 Preparation

Technical: drawings, process documents and inspection standards compiled and disclosed. Materials: pre-procured with incoming QC; redundancy on key parts. Site: power/air/earthing conditions confirmed before shipping.

14.3 Field Process

Joint unpack and check; position and level; connect air to the FRL with leak check and pressure set; connect power and earthing; power-on tests; system integration (lid/press/signal/display/alarm functions); on-site shielding re-test; trial production with customer products; cleanup and tidy wiring.

14.4 Quality Control

Three-inspection (self/mutual/special) per process; 100% check of shielding effectiveness and electrical safety with retained data; standard torque with thread-lock on key fasteners; >=24h continuous aging before shipment.

14.5 Safety

PPE and customer site rules; electrical work with power off and warning signs; never point cylinders at personnel during pneumatic debug; no smoking with fire equipment; power/air off after daily work.

15. After-Sales Service

15.1 Warranty

1-year whole-unit warranty from acceptance; free repair/parts for non-human faults; consumables (seal strips, probes, silencers) at cost; lifetime maintenance.

15.2 Response

7×24 hotline; general issues 2h solution; on-site 24h Pearl River Delta / 48h national; major issues with PM escalation until resolved.

15.3 On-Site Services

Free installation, commissioning and training; annual free inspection in warranty (cleaning, performance check, hidden risks); annual maintenance agreements after warranty.

15.4 Spares

Stocked consumables and core parts; emergency 48h dispatch; lifetime cost-price original spares.

15.5 Lifetime Support

Free technical consultation and software upgrades; retrofit solutions for product/process changes; customer device archives with service history.

16. Training Plan

16.1 Training Objectives and Audience

Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.

Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.

16.2 Tiered Training Content System

Level 1: Basic operation training (1 day)

– Basic principles: system concepts, structure composition, performance indicators;

– Daily operation standards: correct operation of equipment, control and safety systems;

– Daily inspection contents: daily/weekly/monthly check items;

– Safety precautions: usage prohibitions and emergency handling procedures.

Level 2: Maintenance training (1 day)

– Detailed structure of each subsystem and working principles;

– Daily maintenance methods: cleaning, fastening checks, routine care;

– Common fault identification and simple handling;

– Emergency handling procedures for power failure, fire and equipment faults.

Level 3: Advanced management training (as needed)

– Performance influencing factors and how to avoid degradation;

– Upgrade and expansion knowledge and specification requirements;

– Relevant national standards interpretation.

16.3 Training Methods and Schedule

– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;

– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.

16.4 Training Assessment and Documentation Delivery

– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;

– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.

17. Anonymous Typical Project Scenarios

All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.

17.1 Leading Home-Appliance Company Yuba Remote 2.4G Test Project

Background. A top sanitary/home-appliance company mass-produced yuba remotes; manual testing was slow, inconsistent and allowed defects to slip.

Solution. Custom 10-station automated semi-shielded system with contour fixtures, integrating signal power testing, key function testing and LED check.

Results. Hourly throughput x6; test staff -70%; data consistency greatly improved; defect capture raised to 99.5%; equipment cost recovered in six months; follow-up orders for more lines.

17.2 Smart-Hardware Vendor WiFi Module Performance Test Project

Background. A smart-home solution provider’s 2.4G WiFi module mass testing suffered external EMI causing unstable data and ungradable performance.

Solution. High-effectiveness shield box with internal pyramidal absorber, signal source, power meter and multi-channel switching.

Results. Test-environment interference reduced 45dB; data fluctuation from +-5dB to +-0.5dB; accurate grading for mass production.

17.3 Automotive Electronics Remote-Key RF Test Project

Background. A car parts supplier needed to simulate different distances and angles of remote-key reception — full shield boxes could not simulate real scenarios.

Solution. Semi-shielded system with 3D adjustable directional antenna, multi-step power attenuation and multi-station rotating fixture.

Results. Precisely simulated 0-50m equivalent distances at multiple angles; results matched real-vehicle testing 95%+; far fewer vehicle tests, shorter R&D cycles.

18. SEO Optimization Section

All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.

18.1 Keyword System

– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;

– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;

– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;

– Brand keywords: KITOZER, Guangzhou Lain.

18.2 SEO Tag System

– Title tag: the article title — Guangzhou Lain KITOZER;

– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;

– H1 tag: the article title;

– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.

18.3 Internal Link Anchor Text

– Core anchor text: technical design solution, system construction;

– Long-tail anchor text: configuration list, technical parameters, construction plan;

– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.

19. Official Contact Information

– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Official Website: https://gdlain.com

– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)

– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.

Scroll to Top