1. Cover / Document Information

– Document Title: Automatic Production Line Electrical Cabinet Technical Design Solution

– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Date: August 2026

– Version: V1.0

– Project Type: Technical design solution for Automatic Production Line Electrical Cabinet

2. Table of Contents Structure

1. Company Introduction

2. Project Overview

3. User Requirement Analysis

4. Overall Design Description

5. Detailed System Design and Product Technical Parameters

6. Project Quotation and Configuration List

7. Core Solution Advantages

8. Technical Q&A

9. Construction Schedule Plan

10. Construction Organization Plan

11. After-Sales Service System

12. Operation and Maintenance Training Plan

13. Typical Project Cases

14. SEO Optimization System and Website Backend Configuration

15. Contact Information

3. Company Introduction

3.1 Company Development Overview

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.

After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.

3.2 Core Business System

The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:

– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;

– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;

– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;

– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.

3.3 Brand and Qualification Honors

The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.

3.4 Core Competitive Advantages

1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;

2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;

3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;

4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.

4. Project Background and Objectives

4.1 Project Background

This project designs and produces electrical control cabinets for two automated surface-treatment production lines (PTH line and pattern-plating tin-nickel line) at Zhuhai Lingyi. The electrical control systems are centrally housed in dedicated industrial cabinets providing component protection, neat wiring, operational safety and convenient O&M. Design strictly follows the two supplied cabinet drawings; both systems use identical specifications — three single cabinets joined side by side (total width 2,400mm) with dedicated bases, internal mounting systems and full functional accessories.

4.2 Project Scope

Two lines x 3 standard single cabinets = 6 cabinets: cabinet structure design, internal mounting system, base system, functional accessories, earthing protection and cabinet-joining hardware; drawings J26003-HF202602007-DXT (PTH) and J26004-HF202602006-DXT (pattern plating); 3-cabinet joined form, 2,400mm total width.

4.3 Design Objectives

Structural safety: sufficient strength and load capacity for long-term industrial workshop operation at industry-standard protection. Complete functions: lighting, switches, document storage, earthing and joining accessories for on-site electrical assembly and daily O&M. Easy transfer: removable base panels compatible with standard forklifts. Uniform appearance: even coating, flat surfaces, uniform seams. Compliance: electrical-control-cabinet industry standards and drawing requirements.

4.4 Compilation Basis

Supplier drawings J26003/J26004; GB 7251.1-2013 (low-voltage assemblies), GB/T 19668.1-2014, GB 50054-2011 (distribution), JB/T 10328-2002 (fixed panel assemblies), GB 4208-2017 (IP), general sheet-metal cabinet process codes.

5. User Requirement Analysis

5.1 Structure and Size

Single cabinet 1800x800x500mm; 3-cabinet join total 2,400mm with tight uniform seams; front single door + removable rear back panel (rear wiring/maintenance); only the two outer side panels (2 pieces) for the joined set.

5.2 Internal Mounting

Hot-dip galvanized mounting plate per cabinet with modular holes; join-gap filler plates for appearance and ingress protection; depth-adjustable mounting.

5.3 Base and Transfer

Integrated base 2400x500x260mm carrying all three cabinets, black finish, removable panels for forklift access without lifting equipment.

5.4 Accessories

Internal LED lighting with control switch, A4 steel document pocket, heavy hinges, locks, sealing, earthing and joining hardware — complete for immediate electrical assembly.

5.5 Environment

Surface-treatment workshops are hot, humid and corrosive — high-adhesion coating, elevated base against ground moisture, IP54 sealing, complete earthing.

6. Design Principles and Applicable Standards

6.1 Design Principles

Customization: full in-house sheet-metal/coating/assembly — precise per drawing at controlled cost and lead time. Professional structure: workshop-environment optimized (corrosion resistance, elevated base, sealing, earthing); multi-point joining for flat uniform seams; modular internal mounting. Quality control: three-level inspection (incoming/process/final) with 99.8%+ pass rate and third-party reports on request. Complete configuration: all accessories included — no extra procurement; optional fans, thermostats, heaters, windows, meters, sockets. Service: 7×24 consultation, free warranty repair, on-site guidance, lifetime maintenance.

6.2 Applicable Standards

Per section 4.4 (GB 7251.1, GB 50054, JB/T 10328, GB 4208, GB/T 9286, GB/T 12970.2 for grounding braids).

7. System Architecture and Working Principle

7.1 Cabinet Configuration

Each line: 3 single cabinets (1800x800x500mm) joined horizontally (total 2,400mm) sharing interior frames — only 2 outer side panels; front single doors for operation/maintenance, removable rear back panels for wiring; 2 join-gap filler plates (front + rear); integrated base 2400x500x260mm with removable panels for forklift transfer; internal mounting plates with modular holes; lighting, document pocket, earthing and joining hardware.

7.2 Working Principle

Components mount on the hot-dip galvanized plate (conductively bonded to the frame — no separate earthing); power enters via bottom glanded openings; cabinets joined with high-strength connectors; all metal bonded to the earthing terminal (<=0.1 ohm continuity) with 25mm2 braided earth straps to the site bus; the sealed IP54 body with polyurethane gaskets protects components in the humid/corrosive workshop.

8. Detailed Technical Design

8.1 Cabinet Body

Single cabinet 1800x800x500mm; frame 2.0mm cold-rolled steel (columns/top/base), doors/sides/back 1.2-1.5mm; static load >=800kg, mounting plate single-point >=50kg, top uniform 100kg; IP54 (GB 4208); pretreatment (degrease/acid/phosphating/passivation) + electrostatic epoxy powder 60-80um, gloss 30+-5, adhesion 0 (GB/T 9286), salt spray >=48h; RAL7035 (custom RAL available); modular mounting holes 25mm pitch phi5.3mm; bottom entry zone with glands. Front door: 1720x740mm (+-0.5), 1.5mm with horizontal/vertical ribs; 2 heavy detachable hinges (zinc body + stainless pin, >=60kg each, >=120°, quick door removal); flat cabinet lock (zinc body, galvanized latch, master key, anti-pry, >=10,000 cycles); full-perimeter polyurethane foam gasket (compression >=30%, aging resistant); default right-opening (left optional); flush handle. Back panel: 1720x740mm, 1.2mm, M6 bolts <=300mm pitch, 2 horizontal ribs, rust-inhibiting primer inside / body-color topcoat outside, uniform seams. Outer side panels: 1800x500mm, 1.2mm, clip + bolt dual fixing (no exposed screws), internal pressing reinforcement, 2 per joined set.

8.2 Internal Mounting System

Galvanized mounting plate: 1600x700x2.5mm (+-0.5, flatness <=0.5mm/m2); Q235B hot-dip galvanized (zinc >=8um, no defects); surface resistance <=0.1 ohm; modular holes phi5.2mm, 50x50mm matrix, +-0.2mm, M4/M5; depth adjustable 0-50mm via galvanized brackets; uniform load >=100kg/m2, single point 50kg; galvanic life >=10 years; conductively bonded to the frame. Filler plates: 1800mm high, 1.2mm, body-color coating, slot mounting flush — cover join gaps, prevent ingress; 2 per set (front + rear).

8.3 Base System

Fixed base: 2400x500x260mm (+-2); 40x40x2.5mm carbon-steel square tube welded frame with 2.0mm steel bottom; full welding ground smooth with rust primer; uniform static load >=2,000kg; black electrostatic coating RAL9005 70-90um (scratch/oil/acid resistant); top locating pins and bolt holes (+-1mm alignment); anti-slip rubber pads; forklift slots (entry height >=150mm, width >=200mm, 3t standard). Removable panels: 4 pieces (front/back long + 2 side short), 1.2mm folded steel, M5 inner bolts (no exposed fasteners), ordinary Phillips screwdriver, <=1min per panel — closed for aesthetics, removed for forklift transfer.

8.4 Functional Accessories

LED lighting: AC220V +-10% 8W, 6500K, Ra>=80, >=800lm, 600x30x20mm, clip mount top inside, plug-in terminals, IP20, >=50,000h, >=300lux mid-cabinet. Switch: AC220V 10A single-pole rocker (or door-operated travel switch), silver contacts, mechanical >=100,000 / electrical >=50,000 cycles, embedded in door/column, IP20. A4 document pocket: 0.8mm steel folded, 230x310x20mm, top opening, screw mount on the door inside, body-color coating. Heavy hinges: detachable, zinc body + stainless pin, >=60kg, 120°, nickel plated, >=30,000 cycles.

8.5 Cabinet-Joining System

Joining kit: 4 connector plates (2.0mm galvanized folded) + 8 x M6x20 bolts + 8 flat + 8 spring washers + 8 nuts per set; connectors on upper/lower columns of adjacent cabinets (2 per joint); lateral pull strength >=500kg; 3 sets per 3-cabinet join; galvanized passivated, hidden inside; adjustment margin for alignment.

8.6 Earthing System

Grounding braid: tinned copper wire braid (0.15mm strands), 25mm2, 500mm standard (custom lengths), OT-type tinned lugs phi8, DC resistance <=0.007 ohm/m, working <=150 degC, per GB/T 12970.2 — cabinet to site bus and inter-cabinet equipotential. Continuity: all metal bonded; terminal-to-any-part <=0.1 ohm tested at factory.

8.7 Electrical Performance

Rated AC380V/220V; insulation 660V; withstand 2500V/1min; continuity <=0.1 ohm; IP54; -10~+40 degC working, -25~+55 degC storage; <=90% RH; <=2000m (derated above); pollution degree 3.

9. Recommended Configuration and Preliminary Budget

9.1 Configuration Summary (Per Joined System of 3 Cabinets)

3 x single cabinets (front door, back panel, 2 outer side panels, flat lock + keys, gaskets, hinges); 3 x galvanized mounting plates + adjustable brackets; 2 x filler plates; 1 x integrated base 2400x500x260 with 4 removable panels; 3 x LED lights + 3 switches; 3 x A4 document pockets; 3 x joining kits; 3 x 25mm2 braided earth straps; packaging and delivery.

9.2 Budget Notes

Quoted per confirmed drawings and configuration; optional accessories (fans, thermostats, heaters, windows, meters, sockets) itemized; tax-inclusive in RMB (CNY) only; 7-10 working days standard (10-15 custom); 12-month warranty with 7×24 support; lifetime maintenance.

10. Technical Specifications

10.1 System Specification Summary

Item Specification
Cabinet Single 1800x800x500mm; frame 2.0mm steel, doors/sides/back 1.2-1.5mm; 3-cabinet join = 2400mm (seams <=1mm); front single door (1720×740, >=120°, detachable, flat lock >=10,000 cycles); removable back panel (M6, 2 ribs); 2 outer side panels (clip+bolt); IP54; coating 60-80um RAL7035 (adhesion 0, salt spray >=48h); static >=800kg, top 100kg
Mounting 1600x700x2.5mm hot-dip galvanized plate (zinc >=8um, <=0.1 ohm, modular phi5.2 holes 50x50mm, depth 0-50mm, >=100kg/m2, single point 50kg); 2 filler plates per set
Base 2400x500x260mm; 40x40x2.5 square-tube welded frame + 2.0mm bottom; static >=2,000kg; RAL9005 70-90um; locating pins +-1mm; rubber pads; forklift slots (>=150mm height, >=200mm width, 3t); 4 removable panels (M5 inner, <=1min)
Accessories 3 x LED lights (8W 6500K >=800lm >=50,000h, >=300lux) + switches (10A, >=100k cycles); 3 x A4 document pockets; heavy detachable hinges >=60kg >=30,000 cycles
Joining 3 kits (4 plates + 8 bolts/washers/nuts each), connectors on upper/lower columns, pull strength >=500kg, hidden, adjustable
Earthing 3 x 25mm2 tinned copper braids (<=0.007 ohm/m, OT lugs phi8, GB/T 12970.2); continuity <=0.1 ohm; site resistance <=4 ohm
Electrical AC380/220V; insulation 660V; withstand 2500V/1min; pollution 3; -10~+40 degC; <=90% RH; <=2000m
Delivery 7-10 working days standard (10-15 custom); pearl-cotton + wood-frame packing; 12-month warranty; 7×24 support; 1h response, 24h/48h on-site; lifetime maintenance

10.2 Standards Compliance

GB 7251.1-2013, GB 50054-2011, JB/T 10328-2002, GB 4208-2017, GB/T 9286-1998, GB/T 12970.2; ISO9001 quality system; per-unit final inspection with certificates.

11. Key Advantages and Customer Value

11.1 Source-Factory Customization

20+ years; full in-house sheet-metal/coating/assembly with NC punch/bender/laser and automatic coating line; precise non-standard fabrication at controlled cost and lead time; BOM management and traceability.

11.2 Professional Structural Design

Workshop-environment optimized (corrosion, moisture, heat); elevated base against ground moisture; sealed IP54; complete earthing; multi-point joining for flat uniform seams; modular internal mounting for future electrical assembly.

11.3 Strict Quality Control

Three-level inspection with 99.8%+ pass rate; key parameters (bending, welding, coating thickness, earthing resistance) batch-tested; third-party reports on request.

11.4 Complete Configuration

All accessories included — assemble and use; optional fans/thermostats/heaters/windows/meters/sockets; one-stop supply.

11.5 Convenient Transfer

Removable base panels + forklift slots — standard forklift relocation without lifting equipment; solves workshop cabinet-moving pain.

11.6 Full After-Sales

7×24 consultation, free in-warranty repair/replacement, on-site installation guidance, lifetime maintenance with cost-price original parts.

12. Technical Q&A (50+ Items)

12.1 Cabinet Structure

Q1: Single-cabinet size and joined width?

A: 1800x800x500mm; 3-cabinet join = 2,400mm total with seams <=1mm — neat uniform appearance.

Q2: Door and back panel?

A: Front single door (default right, left optional); rear back panel bolted and removable for rear wiring/maintenance.

Q3: Why only 2 side panels for 3 cabinets?

A: Middle cabinets share side frames — only the two outer ends need panels; saves cost, structurally correct.

Q4: Protection rating for dusty/humid workshops?

A: IP54 (GB 4208) — blocks >1mm dust and splashes; suited to general industrial workshops.

Q5: Material and thickness?

A: Frame 2.0mm cold-rolled steel; doors/sides/back 1.2-1.5mm; static load >=800kg without deformation.

Q6: Color customization?

A: Default RAL7035 (base RAL9005); any RAL color per requirement.

Q7: How is the door sealed?

A: Full-perimeter polyurethane foam gasket, compression >=30%, aging-resistant — maintains IP54.

Q8: Can the door be removed for large components?

A: Yes — detachable heavy hinges allow quick door removal without tools.

12.2 Internal Mounting

Q9: Mounting plate spec?

A: 2.5mm hot-dip galvanized, Q235B, 1600x700mm — mechanical strength plus conductive earthing.

Q10: Pre-drilled holes?

A: Modular phi5.2mm holes at 50x50mm matrix — direct M4/M5 mounting of breakers, contactors, PLCs without field drilling.

Q11: Filler plates purpose?

A: Cover join gaps (front + rear) for appearance and ingress prevention; 2 per set.

Q12: Depth adjustable?

A: 0-50mm via brackets per component thickness and wiring needs.

Q13: Load capacity?

A: >=100kg/m2 uniform, 50kg single point — regular components fine; heavy items add fixing points or reinforcing beams.

Q14: Separate earthing needed?

A: No — galvanized plate bonds through the metal bracket to the frame; complete grounding path via the cabinet earth.

12.3 Base and Transfer

Q15: Base spec?

A: 2400x500x260mm, 40x40x2.5 square-tube welded frame with steel bottom; static >=2,000kg — carries 3 full cabinets.

Q16: Why removable base panels?

A: Aesthetics when closed, forklift access when removed — no lifting equipment needed for relocation.

Q17: Tools for panel removal?

A: Ordinary Phillips screwdriver only; <=1min per panel.

Q18: Base color?

A: RAL9005 black — classic with grey cabinets, dirt-resistant; same-color custom available.

Q19: Shipped assembled or separate?

A: Separate packaging; site placement and bolting is simple with instructions; pre-assembled on request.

Q20: Direct floor placement?

A: Yes — anti-slip rubber pads; optional expansion-bolt fixing for permanent mounting.

12.4 Earthing and Safety

Q21: Grounding braid spec?

A: 25mm2 tinned copper braid, 500mm, OT lugs phi8 — cabinet to site bus and inter-cabinet equipotential.

Q22: Purpose of the earth braid?

A: Protective earthing against leakage shock plus equipotential bonding between joined cabinets.

Q23: Continuity assurance?

A: All metal bonded; factory test terminal-to-any-part <=0.1 ohm per electrical safety standards.

Q24: Site earthing requirement?

A: Per GB 50054, <=4 ohm to the site ground bus.

Q25: Withstand voltage?

A: 2500V/1min no breakdown/flashover; insulation 660V.

12.5 Customization and Delivery

Q26: Size modification?

A: Yes — height/width/depth per space and component count; double doors, glass doors, multi-compartment options.

Q27: Add fans/thermostats?

A: Yes — axial fans, filters, thermostats, heaters per heat load; windows, meters, sockets optional.

Q28: Joining parts shipped together?

A: Yes — separately packed with the packing list.

Q29: Production lead time?

A: 7-10 working days standard; 10-15 custom; schedule confirmed per project.

Q30: Shipping protection?

A: Pearl cotton full wrap + solid wood frame with corner protection; long-term professional carriers.

12.6 Quality and Service

Q31: Standards and certification?

A: GB 7251.1 etc.; ISO9001; per-unit certificate of conformity; third-party reports on request.

Q32: Warranty?

A: 12 months from arrival acceptance; free repair/replacement for non-human quality faults; electrical accessories per their manufacturers.

Q33: On-site issues?

A: 7×24 phone/video guidance; on-site guidance for large projects.

Q34: Response time?

A: 1h response with solution within 24h; common spares within 48h.

Q35: What documentation is delivered?

A: Certificate, packing list, installation/use manual, inspection records, as-built information.

Q36: Training?

A: On-site operation/maintenance training at delivery (structure, operation, maintenance, fault finding) plus manuals.

Q37: Why choose KITOZER/Lain?

A: Source factory with full-process capability, drawing-faithful customization, strict QC and complete service.

Q38: What makes it cost-effective?

A: In-house fabrication (no outsourcing markup), complete accessory set (no extra procurement), long-life galvanic coating and 12-month warranty.

12.7 Project-Specific

Q39: How are the two lines’ cabinets handled?

A: Identical specification per drawing — 3+3 cabinets with the same configuration, shipped as two joined systems.

Q40: Are the drawings followed exactly?

A: Yes — drawing review at order, production BOM per drawing; changes confirmed before production.

Q41: Is the base shared by both lines?

A: Each 3-cabinet system has its own 2400mm base.

Q42: Can the joined cabinets be separated later?

A: Yes — joining connectors removable; each cabinet standalone with its own frame.

Q43: How is the gap tolerance controlled?

A: CNC precision fabrication plus adjustable joining connectors — seams <=1mm.

Q44: What if components are heavier than 50kg?

A: Add fixing points or a reinforcing beam; consult for custom loading.

Q45: Are cable entries pre-cut?

A: Bottom entry zone with knockouts — field or pre-cut per requirement with glands.

Q46: Is the cabinet suitable for washdown areas?

A: IP54 splash protection; keep direct jets away; elevated base protects from floor water.

Q47: Can the lighting be door-linked?

A: Yes — optional door-operated travel switch for auto on/off.

Q48: How are the cabinets earthed together?

A: Inter-cabinet 25mm2 braids plus the common base and site bus — full equipotential.

Q49: What maintenance is required?

A: Periodic door/hinge/lock checks, gasket inspection, coating touch-up if scratched, earthing verification.

Q50: Are spare parts guaranteed?

A: Yes — hinges, locks, gaskets, lights, plates stocked; lifetime cost-price supply.

13. Construction Schedule

13.1 Schedule (Standard, 7-10 Working Days Production + Transport)

No. Work Days Department Deliverable
1 Order confirmation and drawing review 1 Technical, sales Final scheme, drawings, BOM
2 Material procurement/stocking 2 Procurement, warehouse Qualified steel/hardware in stock
3 NC cutting and folding 2 Sheet-metal shop All parts cut/folded, first-piece OK
4 Welding/assembly and grinding 1 Sheet-metal shop Frames and bases welded, smoothed
5 Pretreatment and electrostatic coating 2 Coating shop All parts coated, coating checked
6 Accessory pre-assembly and join trial 1 Assembly shop Hinges/locks/lighting/plates fitted, trial join
7 Final inspection and labeling 1 QC Dimensions/appearance/electrical checked, certificates
8 Packing and shipping preparation 1 Warehouse, logistics Pearl-cotton + wood-frame packed, list complete
9 Transport 2-3 Logistics Delivered to site
10 Arrival acceptance and handover 1 Sales, customer Signed arrival acceptance, technical disclosure

Non-standard/custom orders and peak periods negotiated; optimized scheduling per urgency.

14. Construction Organization and Quality/Safety Measures

14.1 Organization

Project lead (1): overall progress, coordination, single customer contact. Technical designer (1): drawing deepening, process conversion, technical problem solving. Production lead (1): workshop scheduling and process quality. QC engineer (1): process and final inspection with records. After-sales contact (1): shipping follow-up, site interface, service response.

14.2 Production Process

Drawing deepening: process conversion per drawings — part/assembly drawings, materials, tolerances, surface treatment, BOM confirmed by the customer before production. Sheet metal: NC punch/bender for precision; gas-shielded welding, grinding smooth. Surface: degrease/acid/phosphating/passivation then electrostatic powder, high-temperature curing — uniform color and adhesion. Assembly: hinges/locks/gaskets/lighting/switches/brackets pre-installed; join trial verifying alignment and opening. Inspection/packing: full inspection; pearl-cotton wrap + wood-frame; accessories boxed with list, certificate and manual.

14.3 Quality Control

Incoming material control (reputable steel with certificates, brand-name fasteners with sampling); first-piece inspection per process before batch production, key dimensions 100% checked; key control points (bending, welding strength, coating thickness, earthing resistance) batch-tested with records; full final inspection per cabinet (dimensions, appearance, door/lock function, earthing, IP sampling) — unqualified never ships.

14.4 Safety and Civilized Production

Certified operators with PPE; welding/spraying special posts certified; tidy materials with clear passages and effective fire equipment; daily hazard inspection; finished products protected from damage; careful handling and secured transport.

14.5 Site Delivery

Assist arrival count and appearance acceptance; provide installation/use manual guiding base assembly, cabinet fixing and joining; on-site operation/maintenance training; periodic follow-up.

15. After-Sales Service

15.1 Warranty

12-month free warranty from arrival acceptance; free repair/replacement for quality faults (structure deformation, coating peeling, hardware damage); human/force-majeure/misuse paid at cost; electrical accessories per their manufacturers with our coordination.

15.2 Response

7×24 technical hotline; general faults 1h response with solution within 24h (phone/video guidance); major on-site: 24h Pearl River Delta / 48h nationwide (remote negotiated); common spares within 48h, custom per agreement.

15.3 Lifetime Maintenance

Lifetime service with cost-price original parts; periodic follow-up and maintenance advice; preferential support for expansion/retrofit/relocation; customer product archives for precise service.

15.4 Supervision

Service supervision hotline; complaints verified within 24h; continuous service improvement.

16. Training Plan

16.1 Training Objectives and Audience

Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.

Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.

16.2 Tiered Training Content System

Level 1: Basic operation training (1 day)

– Basic principles: system concepts, structure composition, performance indicators;

– Daily operation standards: correct operation of equipment, control and safety systems;

– Daily inspection contents: daily/weekly/monthly check items;

– Safety precautions: usage prohibitions and emergency handling procedures.

Level 2: Maintenance training (1 day)

– Detailed structure of each subsystem and working principles;

– Daily maintenance methods: cleaning, fastening checks, routine care;

– Common fault identification and simple handling;

– Emergency handling procedures for power failure, fire and equipment faults.

Level 3: Advanced management training (as needed)

– Performance influencing factors and how to avoid degradation;

– Upgrade and expansion knowledge and specification requirements;

– Relevant national standards interpretation.

16.3 Training Methods and Schedule

– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;

– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.

16.4 Training Assessment and Documentation Delivery

– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;

– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.

17. Anonymous Typical Project Scenarios

All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.

17.1 Surface-Treatment Line Control Cabinet Supply (Zhuhai Lingyi PTH / Pattern-Plating Tin-Nickel Lines)

Background. Two automated surface-treatment lines required centralized electrical control cabinets protecting components in hot, humid, mildly corrosive workshops, with neat wiring, safe operation and convenient maintenance.

Solution. Two joined systems (3 x 1800x800x500mm cabinets each, 2,400mm total), IP54 RAL7035 bodies with removable back panels, hot-dip galvanized mounting plates, integrated black bases with removable panels for forklift transfer, LED lighting, document pockets, joining kits and 25mm2 earth braids — exactly per the supplied drawings.

Results. Drawing-faithful delivery with uniform seams; complete accessory set enabled immediate electrical assembly; removable base panels simplified workshop relocation; stable long-term operation in the humid environment — praised by the customer.

17.2 Industrial Automation Cabinet Batch Project

Background. An automation equipment maker needed standardized control cabinets for its production machines with reliable protection and quick delivery.

Solution. Batch-supplied joined cabinets with galvanized mounting plates, IP54 sealing, complete accessories and factory-inspected quality per unified drawings.

Results. Consistent quality with certificates; 7-10 day delivery; reduced field assembly time; strong after-sales with stocked spares.

17.3 Machine-Room / Equipment-Cabinet Customization Project

Background. A facility required custom-size cabinets with added temperature control and metering for sensitive equipment.

Solution. Custom sizes with fans, thermostats, observation windows and meters integrated into the standard body/accessory architecture.

Results. Tailored fit to the space; stable internal temperature; clear status visibility; easy future expansion without cabinet replacement.

18. SEO Optimization Section

All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.

18.1 Keyword System

– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;

– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;

– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;

– Brand keywords: KITOZER, Guangzhou Lain.

18.2 SEO Tag System

– Title tag: the article title — Guangzhou Lain KITOZER;

– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;

– H1 tag: the article title;

– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.

18.3 Internal Link Anchor Text

– Core anchor text: technical design solution, system construction;

– Long-tail anchor text: configuration list, technical parameters, construction plan;

– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.

19. Official Contact Information

– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Official Website: https://gdlain.com

– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)

– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.

Shopping Cart