KITOZER
KITOZER

KITOZER Energy Storage System 2MWh Megapack

Product Overview

The KITOZER 2MWh megapack energy storage system is a large, turnkey AC-coupled storage solution that integrates a 1MW PCS, a 2MWh LiFePO4 battery container, and a master controller into a single 40ft high-cube shipping container. It is designed for utility-scale and grid-connected storage projects, including renewable energy integration, peak shaving, frequency regulation, and backup power. The system ships as a pre-tested container, requiring only grid connection on site. Multiple containers can be clustered to form tens or hundreds of MWh storage plants, sharing a central energy management system.

Technical Specifications

Rated energy is 2MWh LiFePO4 at 1500V DC nominal. Rated power is 1MW continuous, with peak support up to 2MW for 30 seconds. Usable capacity is 1.8MWh at 90 percent depth of discharge. Cycle life exceeds 7,000 cycles at 80 percent depth of discharge. The PCS achieves 99 percent maximum efficiency. The master controller coordinates redundant battery BMS, PCS, and grid protection, communicating via Modbus TCP. Safety features include smoke detection, gas venting, water mist fire suppression, manual DC disconnect, and thermal runaway barriers. The enclosure is IP55 outdoor rated, operating from minus 30 to 55 degrees Celsius with redundant liquid thermal management. The container includes auxiliary power, lighting, CCTV, and a fire-rated service area.

Application Scenarios

This 2MWh megapack is deployed in utility-scale battery energy storage plants for grid stabilization, renewable energy integration, and capacity firming. Solar and wind farms pair the system with generation to store energy for periods of low production or high demand. Independent power producers use it for arbitrage and frequency regulation. Large industrial parks and commercial campuses use clusters for peak shaving and backup power. Microgrid projects on islands, remote mines, and military bases use the system for reliable off-grid power. The container form factor allows rapid deployment and easy relocation as project needs change.

Advantages and Features

The 2MWh capacity in a single 40ft container maximizes energy density and reduces the number of units required for large projects. The integrated PCS and battery eliminate compatibility risk and simplify commissioning. Redundant thermal management and BMS ensure high availability. The comprehensive fire suppression and gas venting system provides robust safety for grid-scale installations. Parallel operation allows flexible scaling from 2MWh to hundreds of MWh. The master controller provides a unified interface for monitoring and control, with remote access via cloud portal. KITOZER provides long-term service contracts and remote monitoring, ensuring reliable operation throughout the project lifecycle.

Installation and Maintenance Recommendations

Installation requires a reinforced concrete pad capable of supporting approximately 45 tons, adequate drainage, and a grid connection. The container must be grounded, and all AC connections torque-checked before energizing. During commissioning, the KITOZER team verifies PCS-BMS communication on both redundant channels, tests grid protection functions, and configures charge and discharge schedules. Routine maintenance includes quarterly visual inspection, semi-annual terminal torque check, annual liquid loop inspection, and BMS firmware updates. The KITOZER monitoring platform tracks cell voltage imbalance, internal resistance, and temperature trends, predicting maintenance needs. For multi-container plants, implement a coordinated maintenance plan so that at least one full redundancy set remains online during service windows.

Reliability and Energy Impact

Every KITOZER unit undergoes extended factory testing including 72 hours of full-load burn-in, efficiency verification, and grid protection function testing before shipment. Critical components are sourced from established industrial brands, and the assembly complies with CE and international grid code standards. KITOZER provides complete as-built documentation including electrical schematics, P&ID drawings, test reports, and spare part lists. The high efficiency of up to 99 percent means minimal energy loss during conversion, reducing operating cost and carbon emissions over the 15-year service life. A five-year warranty covers manufacturing defects, and the cloud monitoring platform tracks efficiency, runtime, and alarm history, enabling predictive maintenance. The open communication protocol integrates easily with third-party energy management and SCADA systems.

Return on Investment

The up to 99 percent efficiency means minimal energy is lost during conversion, reducing operating cost over the system life. Parallel operation allows customers to start with one unit and add capacity as demand grows, matching capital expenditure to revenue. For grid-scale projects, revenue from frequency regulation, peak shaving, and energy arbitrage typically delivers a payback period of five to eight years. The cloud monitoring portal provides detailed performance and revenue reports for investors and auditors. Contact KITOZER for a project-specific financial model based on local tariff and grid service rates. The engineering team will evaluate your battery voltage, grid code, and load profile to recommend the optimal configuration.

Price

From $218,000 per container, including 1MW PCS, 2MWh battery, master controller, and one year of cloud monitoring. Contact KITOZER for multi-container plant design and grid connection.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com