Brand: KITOZERãSeries: KTR-ODS72ãCategory: Optical Communication / Fiber Distribution Frame
72-port LCfull-load ODF19-inch racksplice trayKTR-ODS72
Table of Contents
Toggle1. Overview
The KITOZER KTR-ODS72 is a 19-inch rack-mount fiber distribution frame (ODF) fully loaded with 72 LC duplex adapters (144 fibers), installed in standard 19-inch racks. The ODF is the patch hub between backbone and horizontal cabling: incoming outdoor/backbone cable is spliced to pigtails inside splice trays; the pigtail LC connector plugs into the adapter panel; patch cords then link to switch optical ports or horizontal cable.
KTR-ODS72 is 3U (133 mm) high, 19-inch (482 mm) wide, 250 mm deep. It holds 6 splice trays (12 fibers each), each with splice sleeves and excess-fiber storage. The front panel is detachable; 72 LC adapters in 3 rows (24 per row), LC duplex = 144 fibers. It includes cable management rings and fiber clamps, with patch cords exiting through the side. Slide-out design eases splicing and maintenance.
Typical uses: data center backbone patching, building telecom room cable termination, base station ODF, FTTH aggregation points. Full-load ODF ships with adapters and trays pre-installed â on site, only splice the cable, no field assembly needed.
2. Key Features
72-port full load
- 72 LC duplex adapters.
- 144 fibers.
- 3 rows à 24 ports.
- High LC density.
6 splice trays
- 12 fibers per tray.
- Splice sleeves.
- Excess-fiber storage.
- Slide-out trays.
19-inch 3U
- 482Ã250Ã133 mm.
- Cold-rolled steel powder coat.
- Detachable front panel.
- Slide-out maintenance.
Cable management
- Side management rings.
- Cable clamps.
- Ground lead.
- Label strip.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-ODS72 |
| Connector | LC duplex |
| Port count | 72 (144 fibers) |
| Splice trays | 6 Ã 12 fibers |
| Form factor | 19-inch rack 3U |
| Dimensions | 482Ã250Ã133 mm (WÃDÃH) |
| Adapter | LC MM/SM (option) |
| Panel material | Cold-rolled steel powder coat |
| Slide-out | manual slide |
| Mounting | 19-inch rack square holes |
| Operating temp | -10~60â |
| Excess storage | â¥1 m coil |
4. Reference Prices
KTR-ODS72 72-port LC ODF (full-load, SM adapters):Ref. USD 83~167 / unit (CNY 600~1200 @7.2)
KTR-ODS72 72-port LC ODF (MM adapters):Ref. USD 69~139 / unit (CNY 500~1000 @7.2)
KTR-ODS72 empty chassis (no adapters/trays):Ref. USD 42~69 / unit (CNY 300~500 @7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center backbone fiber patching.
- Building telecom room cable termination.
- Base station room ODF.
- FTTH aggregation point.
- Industrial fiber network patching.
6. Installation & Maintenance
Installation
- Mount ODF in 19-inch rack U-position.
- Secure front panel to square holes.
- Feed backbone cable from rear.
- Clamp cable, strip outer jacket.
- Splice fibers in trays.
- Coil excess fiber in tray storage.
- Plug pigtail LC into front adapters.
- Label port numbers on strip.
Maintenance
- Check port labels monthly.
- Clean patch cord end-faces quarterly.
- Inspect splice tray excess storage.
- Tighten cable clamps.
- Test patch link loss.
- Recap unused ports.
7. FAQ
- Q:Full-load vs empty chassis?
A:New projects choose full-load (pre-installed adapters + trays) â only splice on site, saves labor. Expansion or existing setups choose empty chassis and buy adapters/pigtails separately. Full-load costs slightly more but installs fast. - Q:LC vs SC adapters?
A:LC is half the size of SC, higher density â suits data center high-density cabling (72 LC = 144 fibers). SC suits FTTH/building cabling (lower density). New data centers recommend LC. - Q:Splice vs mechanical (fast) connection?
A:Splicing has low loss (â¤0.1 dB), long-term stable â suits backbone cable long-term. Mechanical (cold) connects fast but higher loss (â¤0.5 dB), ages faster â suits temporary cabling. Backbone in ODF: splice. - Q:Does 72-port ODF support MM or SM?
A:Both â determined by adapter type. MM adapters (aqua) for OM3/OM4 short reach (â¤300 m); SM adapters (blue) for long reach (>10 km). Specify fiber type when ordering.
8. Trend & Selection
Fiber ODFs are trending high-density (MTP/MPO pre-terminated), modular (replaceable adapter modules), and smart patching (RFID labels). In 40G/100G/400G cabling, MTP-LC conversion modules are common in ODFs, supporting fast pre-terminated cable deployment.
9. Delivery & Service
KITOZER sizes KTR-ODS72 by cable fiber count and connector type, providing port distribution diagrams and splice tray allocation. Delivery includes full-load ODF (adapters + trays + pigtails), mounting screws, certificate and manual. Warranty covers splice loss test guidance.
10. Additional Notes
A common pitfall is too-small bend radius. Fiber bend radius must be â¥30 mm (below 20 mm increases loss or breaks). Coil excess fiber in trays with proper curvature â do not kink.
Another pitfall is pulling patch cords hard. Insert/remove patch cords gently; fiber pull strength â¤5 N. Route excess cords through management rings â avoid hanging under tension.
Also verify pigtail length matches tray depth â too-long pigtails won’t fit, too-short ones won’t reach the adapter. Standard pigtails are 1.5 m; KTR-ODS72 trays accept up to 2 m excess comfortably.
Selection summary: 72-port LC full-load; 6 splice trays; 3U 19-inch; cold-rolled steel; slide-out. The ODF is the fiber network’s patching hub â clean splices, neat routing, clear labels keep the fiber link maintainable.