KITOZER
KITOZER

KITOZER Screw Chiller 200RT Water Cooled For Commercial Cooling

The KITOZER 200RT water cooled screw chiller is engineered to deliver stable, efficient chilled water for commercial office buildings, industrial process cooling, hotels, hospital HVAC systems, and medium sized data center secondary loops. Built around twin screw semi hermetic compressors with 6:6 asymmetric rotor profiles, the unit provides reliable year round operation with low vibration and low noise. The condenser and evaporator are high efficiency shell and tube heat exchangers with enhanced internally grooved copper tubes, maximizing heat transfer while minimizing pressure drop. A microprocessor based controller with touch screen HMI monitors suction and discharge pressures, oil temperature, water flow, and alarm history in real time, and supports Modbus RTU or Modbus TCP integration with building management systems.

Product Overview

KITOZER 200RT screw chillers use R134a or R513A low GWP refrigerant and are available with fixed speed or inverter driven compressor options. The evaporator produces 7 C chilled water return and 12 C supply under standard design conditions, and the condenser rejects heat at 30 C inlet and 37 C outlet. The complete unit includes refrigerant side safety valves, refrigerant sight glasses, oil return system, crankcase heater, water side pressure relief valves, and stainless steel water connection flanges. The frame is powder coated carbon steel with anti corrosive epoxy coating suitable for indoor chiller plant rooms.

Technical Specifications

Cooling capacity 200 RT (703 kW), COP up to 5.8 kW per kW under AHRI standard conditions, EER up to 4.2. Compressor twin screw semi hermetic, two stage capacity control from 25 percent to 100 percent. Evaporator water flow 120 m3 per h, pressure drop 60 kPa, water side volume 85 L. Condenser water flow 145 m3 per h, pressure drop 65 kPa. Power supply 3 phase 380 V 50 Hz, rated input power 121 kW, full load current 210 A. Refrigerant charge R134a 45 kg. Operating ambient up to 45 C. Sound pressure level 72 dB(A) at 1 m. Net weight 3800 kg. CE, ISO 9001 certified, 3 year compressor warranty.

Application Scenarios

This chiller is widely used in central HVAC systems for shopping malls, office towers, airport terminals, and hospital central plants. It also serves process cooling applications such as plastic injection molding, laser cutting machine cooling, chemical reaction vessel cooling, and food and beverage production lines. The stable outlet water temperature within plus or minus 0.5 C makes it suitable for precision manufacturing environments where tight process temperature control is required. It can be paired with KITOZER cooling towers, chilled water pumps, and water side chemical treatment systems to form a complete central plant package.

Advantages and Features

The twin screw rotor profile reduces part load energy consumption by up to 30 percent compared with old piston type chillers. The slide valve stepless capacity control matches cooling load exactly, avoiding frequent on off cycling. Built in anti freeze protection, high pressure and low pressure switches, overload relays, and phase sequence protection ensure safe operation. The economizer circuit improves sub cooling and increases cooling capacity by 8 to 12 percent. Optional partial heat recovery module can capture condenser waste heat to preheat domestic hot water, reducing boiler load. The compact footprint simplifies installation in limited plant room space.

Installation and Maintenance

Install the chiller on a reinforced concrete foundation with vibration isolation pads. Connect chilled water and condenser water pipes with flexible connectors to avoid stress transfer. Provide adequate clearance of at least 1.5 m around the unit for compressor and tube bundle servicing. Flush the water loop thoroughly before startup to remove welding slag and debris. Commissioning must be performed by trained technicians who verify refrigerant charge, water flow direction, sensor calibration, and protection settings. Monthly maintenance includes checking refrigerant sight glass, oil level, water filter differential pressure, and electrical terminal torque. Annually inspect tube bundle condition, clean condenser tubes if scaling is observed, and calibrate temperature and pressure sensors.

Price

From $18,500 per unit. Contact KITOZER sales for project based quotation, factory lead time, and CIF delivery to your nearest port.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com