1. Overview

The KITOZER KTR-ES08 is a wall-mount temp & humidity sensor with RS485 bus communication, for rooms, warehouses, archives, labs and workshops requiring continuous monitoring. It uses a Swiss high-precision temp/humidity probe: temp -20~60℃, accuracy ±0.3℃; humidity 0~95% RH, accuracy ±2% RH. The front panel has an LCD showing live values.

KTR-ES08 is powered by DC12V (or DC24V); the RS485 interface supports Modbus-RTU at 9600~115200 bps, with DIP-switch address setting. Up to 32 sensors can be hand-in-hand daisy-chained on one RS485 bus to the EMCS platform. The housing is flame-retardant ABS, ~100×80×30 mm, wall-mount.

Typical uses: room hot/cold aisle temp/humidity monitoring, archive storage environment, pharmaceutical GSP compliance, electronics workshop anti-static humidity control. Exceeding thresholds triggers AC/humidifier or platform alarms.

2. Key Features

High-precision probe

  • Swiss import probe.
  • Temp ±0.3℃.
  • Humidity ±2% RH.
  • Response ≤8 s.

RS485 Modbus

  • Modbus-RTU.
  • 9600~115200 bps.
  • DIP address.
  • Up to 32 per bus.

LCD display

  • Front LCD.
  • Live temp/humidity.
  • Adjustable backlight.
  • Alarm blink.

Wall-mount build

  • Flame-retardant ABS.
  • 100×80×30 mm.
  • DC12V/24V.
  • DIN/wall dual-mount.

3. Specifications

Item Parameter
Model KTR-ES08
Temp range -20~60℃
Temp accuracy ±0.3℃ (25℃)
Humidity range 0~95% RH (non-condensing)
Humidity accuracy ±2% RH (20~80% RH)
Protocol RS485 Modbus-RTU
Baud rate 9600~115200 bps (default 9600)
Power DC12V / DC24V
Power draw ≤0.5 W
Display LCD (temp/humidity)
Housing ABS flame-retardant (UL94 V-0)
Dimensions ~100×80×30 mm

4. Reference Prices

KTR-ES08 temp/humidity sensor (LCD, RS485):Ref. USD 21~42 / unit (CNY 150~300 @7.2)

KTR-ES08 temp/humidity sensor (no LCD, economy):Ref. USD 11~21 / unit (CNY 80~150 @7.2)

KTR-ES08 external probe cable (1 m extension):Ref. USD 3~7 / pc (CNY 20~50 @7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room hot/cold aisle monitoring.
  • Archive storage environment.
  • Pharmaceutical GSP compliance.
  • Electronics workshop anti-static humidity.
  • Lab constant temp/humidity monitoring.

6. Installation & Maintenance

Installation

  • Choose representative point (avoid vent/corner).
  • Wall-mount at 1.5 m height.
  • RS485 bus (A/B/G) daisy-chain.
  • DIP-set address (1~32).
  • Wire DC12V power.
  • Add temp/humidity channel on platform.
  • Set temp/humidity alarm thresholds.
  • Verify LCD display — done.

Maintenance

  • Calibrate temp/humidity semi-annually.
  • Clean probe dust cover.
  • Check RS485 bus connections.
  • Inspect power supply voltage.
  • Replace probe if LCD abnormal.
  • Log threshold event history.

7. FAQ

  • Q:Temp/humidity reading off — calibrate?
    A:Compare against a calibration chamber (or saturated salt solution). Write calibration offset in Modbus registers (temp ±5℃, humidity ±10% RH). Calibrate at least annually; mandatory if deviation exceeds accuracy.
  • Q:How many sensors on one RS485 bus?
    A:Standard RS485 (no repeater) supports up to 32 sensors. Beyond 32, add an RS485 repeater or split segments. Bus length should not exceed 1200 m; beyond that, add repeaters. Terminate with 120 Ω at the end.
  • Q:Where to place the sensor?
    A:At the return-air zone between hot and cold aisles, 1.5 m high, away from AC vents, corners, doors/windows. For rack intake temp, place in cold aisle center; for overall room environment, place in room center. Do not mount on walls or at vents.
  • Q:LCD and platform readings differ?
    A:First check LCD stability (local sensor value). Platform mismatch may be Modbus register address error or baud-rate mismatch. Re-verify address, baud rate and register table. If LCD itself jumps, probe fault or unstable power.

8. Trend & Selection

Temp/humidity sensors are trending wireless (LoRa/NB-IoT), multi-parameter integration (temp/humidity + dew point + CO₂), self-calibration and AI prediction. In room EMCS, wireless sensors reduce wiring, and AC linkage with BMS is mainstream.

9. Delivery & Service

KITOZER sizes KTR-ES08 by room测点 layout, providing RS485 bus topology and Modbus register tables. Delivery includes sensor, mounting bracket, power adapter, certificate and manual. Warranty covers platform integration guidance.

10. Additional Notes

A common pitfall is mounting the sensor at the AC outlet. Supply air (12~15℃) fluctuates and does not represent true room ambient. Place it in the return-air zone (between hot/cold aisles) to reflect rack intake temperature.

Another pitfall is omitting the RS485 terminator. The bus end (farthest sensor) must have a 120 Ω terminator; otherwise signal reflection causes unstable communication. Daisy-chain, not star.

Also match the sensor to the environment: in clean rooms or GSP areas, use a filtered probe cover to prevent dust contamination, and schedule quarterly calibration. For outdoor or wet areas, select the IP65 version — the standard IP20 indoor housing is not splash-proof.

Selection summary: temp/humidity combo; ±0.3℃ accuracy; RS485 Modbus; LCD; wall-mount. The sensor is the room’s thermometer — right location, proper bus, periodic calibration, keeps environment monitoring reliable.

SEO Information

Search keywords:temp humidity sensorRS485 temperature humidityhigh precision humidity transmitterKTR-ES08KITOZER

SEM keywords:temp humidity sensor price,RS485 humidity transmitter supplier,high precision temp humidity,KTR-ES08

GEO landing page:lain.com.cn/product/ktr-es08-temperature-humidity-sensor.html

Title:KITOZER KTR-ES08 Temperature & Humidity Sensor (RS485 High-Precision)

Meta Keywords:temp humidity sensor,RS485 temperature humidity,high precision humidity transmitter,KTR-ES08,KITOZER

Meta Description:KITOZER KTR-ES08 temp & humidity sensor uses RS485 Modbus, temp accuracy ±0.3℃, humidity ±2% RH, with LCD display, for room, warehouse and archive monitoring.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart