KITOZER
KITOZER

KITOZER Selector Valve: DN50 Pneumatic for Multi-Zone Gas System

Product Overview

The KITOZER DN50 pneumatic selector valve directs a single bank of gas suppression cylinders to the correct protected zone when multiple rooms share one cylinder group. When the fire alarm panel identifies which zone is on fire, it energizes the corresponding solenoid pilot valve, which opens the selector valve before the main cylinder discharges, ensuring agent flows only to the fire zone rather than flooding all rooms. The valve body is forged brass with a pneumatic piston actuator and manual override, suitable for FM200, IG541, and FK-5-1-12 systems.

Technical Specifications

Nominal diameter DN50, inlet flange PN16, outlet flange PN16, working pressure 6 MPa, opening pressure from pilot air 0.4 to 0.6 MPa, body material forged brass, piston actuator aluminum alloy, pilot solenoid 24V DC 1.5A, manual override lever, visual position indicator open closed, CCCF certified, GB 25972 compliant. Response time under 2 seconds, flow coefficient Kvs 40, operating temperature 0 to 50 degrees Celsius.

Application Scenarios

This selector valve is used in multi-zone gas suppression systems where several protected rooms share one cylinder bank, such as a data center with multiple server rooms, a banking headquarters with several equipment floors, a university campus with multiple electrical substations, or a museum with several display wings. Sharing cylinders reduces hardware cost and floor space compared with independent cylinder groups for each room. Typical installations use one selector valve per zone, piped to a common cylinder manifold via flexible stainless steel hoses.

Key Advantages

The pneumatic piston actuator opens the valve fully within 2 seconds of pilot signal, fast enough to sequence before the main cylinder discharge. The position indicator provides clear visual feedback to the commissioning engineer, confirming which valve is open during each test. The manual override allows local testing without energizing the pilot circuit, simplifying commissioning. KITOZER supplies the selector valve as a complete assembly with pilot solenoid, filter regulator, and tubing, reducing on-site assembly work for the contractor.

Installation and Maintenance Recommendations

Mount the selector valve in a vertical or horizontal position near the cylinder manifold, with the position indicator visible from the maintenance walkway. Pipe the pilot air from the auxiliary nitrogen bottle, and set the regulator to 0.5 MPa. Sequence the test so the selector valve opens at least 3 seconds before the main cylinder discharges, to ensure the route is fully open. Inspect the pilot solenoid and filter quarterly, and verify valve position indicator operation semiannually. Replace piston seal kits every 5 years or after 10 full actuation cycles.

Price

From $480 per valve. Contact +86 13922289957 for selector valve pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com